Influence of Different Base Thicknesses on Maxillary Complete Denture Processing: Linear and Angular Graphic Analysis on the Movement of Artificial Teeth


Autoria(s): Mazaro, José Vitor Quinelli; Gennari Filho, Humberto; Vedovatto, Eduardo; Amoroso, Andressa Paschoal; Pellizzer, Eduardo Piza; Zavanelli, Adriana Cristina
Contribuinte(s)

Universidade Estadual Paulista (UNESP)

Data(s)

30/09/2013

20/05/2014

30/09/2013

20/05/2014

01/09/2011

Resumo

Objective: The purpose of this study was to compare the dental movement that occurs during the processing of maxillary complete dentures with 3 different base thicknesses, using 2 investment methods, and microwave polymerization.Methods: A sample of 42 denture models was randomly divided into 6 groups (n = 7), with base thicknesses of 1.25, 2.50, and 3.75 mm and gypsum or silicone flask investment. Points were demarcated on the distal surface of the second molars and on the back of the gypsum cast at the alveolar ridge level to allow linear and angular measurement using AutoCAD software. The data were subjected to analysis of variance with double factor, Tukey test and Fisher (post hoc).Results: Angular analysis of the varying methods and their interactions generated a statistical difference (P = 0.023) when the magnitudes of molar inclination were compared. Tooth movement was greater for thin-based prostheses, 1.25 mm (-0.234), versus thick 3.75 mm (0.2395), with antagonistic behavior. Prosthesis investment with silicone (0.053) showed greater vertical change compared with the gypsum investment (0.032). There was a difference between the point of analysis, demonstrating that the changes were not symmetric.Conclusions: All groups evaluated showed change in the position of artificial teeth after processing. The complete denture with a thin base (1.25 mm) and silicone investment showed the worst results, whereas intermediate thickness (2.50 mm) was demonstrated to be ideal for the denture base.

Formato

1661-1665

Identificador

http://dx.doi.org/10.1097/SCS.0b013e31822e5d8c

Journal of Craniofacial Surgery. Philadelphia: Lippincott Williams & Wilkins, v. 22, n. 5, p. 1661-1665, 2011.

1049-2275

http://hdl.handle.net/11449/15295

10.1097/SCS.0b013e31822e5d8c

WOS:000295398700026

Idioma(s)

eng

Publicador

Lippincott Williams & Wilkins

Relação

Journal of Craniofacial Surgery

Direitos

closedAccess

Palavras-Chave #Maxillary complete denture #acrylic resins #microwave #silicone #artificial tooth
Tipo

info:eu-repo/semantics/article