929 resultados para computed tomography scanner


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Background: To establish the best methodology for diagnosis and management of patients with solid and complex renal masses by comparing the costs and benefits of different imaging methods and to improve differential diagnosis of these benign and malignant lesions, particularly by investigating tumour calcifications. Methods: We performed a prospective study on 31 patients with solid or complex masses by submitting them to Abdominal Ultrasonography (US), Doppler Ultrasonography of the renal mass (US Dop), Computed Tomography (CT), and Magnetic Resonance Imaging (MRI). Results: We found 28 patients with malignant and three with benign masses. Of the 28 malignant, 17 showed calcifications at CT; 16 central and one was of the pure peripheral curvilinear type (egg shell). Excretory Urography (IVP) had a significantly lower detection rate for central calcifications than both US and CT. Benign and malignant masses appeared as described in literature, with US, CT and MRI showing high sensitivity and specificity in renal tumor diagnosis. The exception was US Dop where we obtained lower sensitivity for the characterization of malignant tumor flow. Conclusions: In this series we were surprised to find that CT revealed central calcifications in 51.6% of patients, all with malignant lesions, while, literature reports a frequency of calcification in renal cell carcinoma between 8 and 22%, in studies using abdominal films and EU (IVP). This finding is of great importance when we consider that these calcifications occur particularly in malignant neoplasms. As a result of comparing these different imaging methods we have developed a better methodology for renal tumor investigation.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

To investigate the ability of BioRoot RCS, a tricalcium silicate-based root canal sealer and AH Plus to effectively fill the root canals of contralateral teeth using three evaluation methods, and to investigate also the correlation between the methods. The prepared root canals of ten pairs of contralateral mandibular premolar teeth were filled with gutta-percha and sealer using lateral compaction. The percentage of voids within the root canal was assessed by micro-computed tomography, whilst sealing ability was investigated by fluid transport and leakage of fluorescent microspheres. The interaction of sealer with dentine, and sealer penetration were assessed by confocal microscopy. The void volume, fluid flow, microsphere leakage and sealer interaction with dentine for both materials were compared. Nonparametric (Mann-Whitney) tests were used to compare the % void and fluid transport of the two sealers. Spearman correlation was used to assess the pairwise relationships between the techniques. The level of significance was set to 0.05. BioRoot RCS exhibited significantly more percentage of voids than AH Plus. There was no difference in fluid flow and microsphere penetration. BioRoot RCS exhibited a different pattern of sealer penetration and interaction with the dentine walls compared to AH Plus. For both materials, the pairwise correlations between the three techniques were close to zero, indicating weak relationships. MicroCT analysis revealed a higher void volume for BioRoot RCS. The other techniques did not show a difference between the sealing ability of the sealers. The correlation between the three ex vivo methods of assessment was weak demonstrating their complementarity rather than their concordance.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Introduction: The request of three-dimensional images (3D) of the dentomaxillofacial complex has increased. Hence, new possibilities for assessment, treatment as well as follow-up after treatment have increased their importance with the use of cone beam computed tomography (CBCT). The images in two dimensions (2D) have inherent problems that can be solved with treedimensional images assessment. Objectives: To clarify the main doubts about the operational mechanism of complementary diagnostic method; to explain the advantages and disadvantages, to discuss the effective radiation dose and possible applications in orthodontia. Conclusion: The information generated by 2D images from the CBCT does not show differences that may endanger the orthodontic planning when compared with the images of 2D conventional radiographs. The effective radiation dose received by the patient should not be considered as a limiting factor of the tomography exam request.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Research on the micro-structural characterization of metal-matrix composites uses X-ray computed tomography to collect information about the interior features of the samples, in order to elucidate their exhibited properties. The tomographic raw data needs several steps of computational processing in order to eliminate noise and interference. Our experience with a program (Tritom) that handles these questions has shown that in some cases the processing steps take a very long time and that it is not easy for a Materials Science specialist to interact with Tritom in order to define the most adequate parameter values and the proper sequence of the available processing steps. For easing the use of Tritom, a system was built which addresses the aspects described before and that is based on the OpenDX visualization system. OpenDX visualization facilities constitute a great benefit to Tritom. The visual programming environment of OpenDX allows an easy definition of a sequence of processing steps thus fulfilling the requirement of an easy use by non-specialists on Computer Science. Also the possibility of incorporating external modules in a visual OpenDX program allows the researchers to tackle the aspect of reducing the long execution time of some processing steps. The longer processing steps of Tritom have been parallelized in two different types of hardware architectures (message-passing and shared-memory); the corresponding parallel programs can be easily incorporated in a sequence of processing steps defined in an OpenDX program. The benefits of our system are illustrated through an example where the tool is applied in the study of the sensitivity to crushing – and the implications thereof – of the reinforcements used in a functionally graded syntactic metallic foam.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Pulmonary artery sarcomas (PAS) are rare and probably incurable tumours. The clinical manifestations are non-specific and very similar to that of patients with thromboembolic disease, resulting in delay of the correct diagnosis and proper treatment. We report the case of a 66-year-old woman with PAS diagnosed by computed tomography guided biopsy. Chemotherapy treatment was initiated but the patient died 11 months after diagnosis.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Antibiotics are potentially a cause of neurotoxicity in dialysis patients, the most common are thebeta-lactams as ceftazidime and cefepime, and few cases have been reported after piperacillin/tazobactam use. This report presents a case of a hypertensive and diabetic 67-year-old woman inregular hemodialysis, which previously had a stroke. She was hospitalized presenting pneumonia,which was initially treated with cefepime. Two days after treatment, she presented dysarthria, lefthemiparesis, ataxia, and IX and X cranial nerves paresis. Computed tomography showed no acutelesions and cefepime neurotoxicity was hypothesized, and the antibiotic was replaced bypiperacillin/tazobactam. The neurologic signs disappeared; however, 4 days after with piperacillin/tazobactam treatment, the neurological manifestations returned. A new computed tomographyshowed no new lesions, and the second antibiotic regimen withdrawn. After two hemodialysissessions, the patient completely recovered from neurological manifestations. The patient presentedsequentially neurotoxicity caused by two beta-lactams antibiotics. This report meant to alertclinicians that these antibiotics have dangerous neurological effects in chronic kidney diseasepatients.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Considered rare tumors, gangliogliomas account for 0.4% - 0.9% of intracranial neoplasms. The peak of its incidence occurs between 10 and 20 years of age. These tumors are composed of glial and ganglion cells and they are relatively low-grade neoplasms associated with good prognoses. We report a case of an atypical calcified ganglioglioma in an 18-year-old woman with history of four months of stabbing right-sided parietal headache, paroxysmal. On image studies were noted the presence of thick wall calcification in gangliogliomas. Although rare, this atypical ganglioglioma should be included in the differential diagnosis of lesions occurring in this area of the brain.