999 resultados para bosonization technique
Resumo:
Rates of rapair of pBR 322 plasmid DNA radicals by thiols of varying net charge (Z) at pH 7 and physiological ionic strength were measured using the oxygen explosion technique. The extent of conversion of supercoiled to relaxed circular plasmid was measured by HPLC as a function of the time of oxygen exposure before or after irradiation, the time-courses being fitted by a pseudo-first-order kinetic expression with k1 = k2[RSH]. Values of k2 (M-1 S-1) were: 2.1 x 10(5) (GSH, Z = -1), 1.4 x 10(6) (2-mercaptoethanol, Z = 0), 1.2 x 10(7) (cysteamine, Z = +1), 6.6 x 10(7) (WR-1065 or N-(2-mercaptoethyl)-1,3-diamino?? propane, Z = +2). The approximately 6-fold increase in rate with each unit increase in Z is attributed to concentration of cationic thiols near DNA as a consequence of counter-ion condensation and reduced levels of anionic thiols near DNA owing to co-ion depletion. The results are quantitatively consistent with chemical repair as a significant mechanism for radioprotection of cells by neutral and cationic thiols under aerobic conditions, but indicate that repair by GSH will compete effectively with oxygen only at low oxygen tension.
Resumo:
This paper presents an investigation of map width enhancement and the performance improvement of a turbocharger compressor using a series of static vanes in the annular cavity of a classical bleed slot system. The investigation has been carried out using both experimental and numerical analysis. The compressor stage used for this study is from a turbocharger unit used in heavy duty diesel engines of approximately 300 kW. Two types of vanes were designed and added to the annular cavity of the baseline classical bleed slot system. The purpose of the annular cavity vane technique is to remove some of the swirl that can be carried through the bleed slot system, which would influence the pressure
ratio. In addition to this, the series of cavity vanes provides a better guidance to the slot recirculating flow before it mixes with the impeller main inlet flow. Better guidance of the flow improves the mixing at the inducer inlet in the circumferential direction. As a consequence, the stability of the compressor is improved at lower flow rates and a wider map can be achieved. The impact of two cavity vane designs on the map width and performance of the compressor was highlighted through a detailed analysis of the impeller flow field. The numerical and experimental study revealed that an effective vane design can improve the map width and pressure ratio characteristic without an efficiency penalty compared to the classical bleed slot system without vanes. The comparison study between the cavity vane and noncavity vane configurations presented in this paper showed that the map width was improved by 14.3% due to a significant reduction in surge flow and the peak pressure ratio was improved by 2.25% with the addition of a series of cavity vanes in the annular cavity of the bleed slot system.
Resumo:
Purpose: The goal of this project was to see if using IMRT to deliver elective pelvic nodal irradiation (EPNI) for prostate cancer reduced acute treatment toxicity.
Methods: Two hundred and thirty patients were enrolled into prospective trials delivering EPNI with a concomitant hypofractionated IMRT boost to the prostate. During accrual, the method of EPNI delivery changed as new literature emerged. Three methods were used (1) 4FB, (2) IMRT with 2 cm CTV margins around the pelvic vessels as suggested by Shih et al. (2005) [7] (IMRT-Shih), and (3) IMRT with nodal volumes suggested by the RTOG (IMRT-RTOG). Initially patients were treated with an empty bladder, with the remainder treated with bladder full.
Results: Patients in the 4FB group had higher rates of grade 2 acute GI toxicities compared to the IMRT-Shih and IMRT-RTOG groups (31.9% vs 20.8% vs 7.2%, p = 0.0009). Patients in the 4FB group had higher rates of grade 3 urinary frequency compared to the two IMRT groups (8.5% vs 0% vs 0%, p = 0.027). However, multivariate analysis suggested the factor that most influenced toxicity was bladder filling followed by IMRT.
Conclusions: Bladder filling appeared to be the dominant factor which predicted for acute toxicity, followed by the use of IMRT.
Resumo:
A modified comb filtering technique is proposed which can be used to reduce framing noise generated when speech signals are transform-coded or vector-quantized. Application of this filter to 9. 6 kbit/s speech in a vector transform coder has been found to improve the perceptual quality of the coded speech.
Resumo:
Design and evaluation of a novel laser-based method for micromoulding of microneedle arrays from polymeric materials under ambient conditions. The aim of this study was to optimise polymeric composition and assess the performance of microneedle devices that possess different geometries.
Resumo:
Analysis and synthesis of the new Class-EF power amplifier (PA) are presented in this paper. The proposed circuit offers means to alleviate some of the major issues faced by existing Class-EF and Class-EF PAs, such as (1) substantial power losses due to parasitic resistance of the large inductor in the Class-EF load network, (2) unpredictable behaviour of practical lumped inductors and capacitors at harmonic frequencies, and (3) deviation from ideal Class-EF operation mode due to detrimental effects of device output inductance at high frequencies. The transmission-line load network of the Class-EF PA topology elaborated in this paper simultaneously satisfies the Class-EF optimum impedance requirements at fundamental frequency, second, and third harmonics as well as simultaneously providing matching to the circuit optimum load resistance for any prescribed system load resistance. Furthermore, an elegant solution using an open and short-circuit stub arrangement is suggested to overcome the problem encountered in the mm-wave IC realizations of the Class-EF PA load network due to lossy quarter-wave line. © 2010 IEICE Institute of Electronics Informati.
Resumo:
Many cardiovascular diseases are characterised by the restriction of blood flow through arteries. Stents can be expanded within arteries to remove such restrictions; however, tissue in-growth into the stent can lead to restenosis. In order to predict the long-term efficacy of stenting, a mechanobiological model of the arterial tissue reaction to stress is required. In this study, a computational model of arterial tissue response to stenting is applied to three clinically relevant stent designs. We ask the question whether such a mechanobiological model can differentiate between stents used clinically, and we compare these predictions to a purely mechanical analysis. In doing so, we are testing the hypothesis that a mechanobiological model of arterial tissue response to injury could predict the long-term outcomes of stent design. Finite element analysis of the expansion of three different stent types was performed in an idealised, 3D artery. Injury was calculated in the arterial tissue using a remaining-life damage mechanics approach. The inflammatory response to this initial injury was modelled using equations governing variables which represented tissue-degrading species and growth factors. Three levels of inflammation response were modelled to account for inter-patient variability. A lattice-based model of smooth muscle cell behaviour was implemented, treating cells as discrete agents governed by local rules. The simulations predicted differences between stent designs similar to those found in vivo. It showed that the volume of neointima produced could be quantified, providing a quantitative comparison of stents. In contrast, the differences between stents based on stress alone were highly dependent on the choice of comparison criteria. These results show that the choice of stress criteria for stent comparisons is critical. This study shows that mechanobiological modelling may provide a valuable tool in stent design, allowing predictions of their long-term efficacy. The level of inflammation was shown to affect the sensitivity of the model to stent design. If this finding was verified in patients, this could suggest that high-inflammation patients may require alternative treatments to stenting.