829 resultados para aneuploidy screening


Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE: DON, a serious complication of GO, is frequently difficult to diagnose clinically in its early stages because of confounding signs and symptoms of congestive orbitopathy. We evaluated the ability of square area measurements of orbital apex crowding, calculated with MDCT, to detect DON. MATERIALS AND METHODS: Fifty-six patients with GO were studied prospectively with complete neuro-ophthalmologic examination and MDCT scanning. Square measurements were taken from coronal sections 12 mm, 18 mm, and 24 mm from the interzygomatic line. The ratio between the extraocular muscle area and the orbital bone area was used as a Cl. Intracranial fat prolapse through the superior orbital fissure was recorded as present or absent. Severity of optic nerve crowding was also subjectively graded on corona! images. Orbits were divided into 2 groups (with or without clinical evidence of DON) and compared. RESULTS: Ninety-five orbits (36 with and 59 without DON) were studied. The CIs at all 3 levels and the subjective crowding score were significantly greater in orbits with DON (P<.001). No significant difference was observed regarding intracranial fat prolapse (P=.105). The area under the ROC curves was 0.91, 0.93, and 0.87 for CIs at 12, 18, and 24 mm, respectively. The best performance was at 18 mm, where a cutoff value of 57.5% corresponded to 91.7% sensitivity, 89.8% specificity, and an odds ratio of 97.2 for detecting DON. A significant correlation (P<.001) between the CIs and VF defects was observed. CONCLUSIONS: Orbital Cls based on area measurements were found to predict DON more reliably than subjective grading of orbital crowding or intracranial fat prolapse.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Clinical multistage risk assessment associated with electrocardiogram (ECG) and NT-proBNP may be a feasible strategy to screen hypertrophic cardiomyopathy (HCM). We investigated the effectiveness of a screening based on ECG and NT-proBNP in first-degree relatives of patients with HCM. Methods and Results: A total of 106 first-degree relatives were included. All individuals were evaluated by echocardiography, ECG, NT-proBNP, and molecular screening (available for 65 individuals). From the 106 individuals, 36 (34%) had diagnosis confirmed by echocardiography. Using echocardiography as the gold standard, ECG criteria had a sensitivity of 0.71, 0.42, and 0.52 for the Romhilt-Estes, Sokolow-Lyon, and Cornell criteria, respectively. Mean values of NT-ProBNP were higher in affected as compared with nonaffected relatives (26.1 vs. 1290.5, P < .001). The AUC of NT-proBNP was 0.98. Using a cutoff value of 70 pg/mL, we observed a sensitivity of 0.92 and specificity of 0.96. Using molecular genetics as the gold standard, ECG criteria had a sensitivity of 0.67, 0.37, and 0.42 for the Romhilt-Estes, Sokolow-Lyon, and Cornell criteria, respectively. Using a cutoff value of 70 pg/mL, we observed a sensitivity of 0.83 and specificity of 0.98. Conclusion: Values of NT-proBNP above 70 pg/mL can be used to effectively select high-risk first-degree relatives for HCM screening. (J Cardiac Fail 2012;18:564-568)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: The aim of this study was to screen CO2 laser (10.6 mu m) parameters to increase enamel resistance to a continuous-flow erosive challenge. Background data: A new clinical CO2 laser providing pulses of hundreds of microseconds, a range known to increase tooth acid-resistance, has been introduced in the market. Methods: Different laser parameters were tested in 12 groups (n = 20) with varying fluences from 0.1 to 0.9 J/cm(2), pulse durations from 80 to 400 mu s and repetition rates from 180 to 700 Hz. Non-lased samples (n = 30) served as controls. All samples were eroded by exposure to hydrochloric acid (pH 2.6) under continuous acid flow (60 mu L/min). Calcium and phosphate release into acid was monitored colorimetrically at 30 sec intervals up to 5 min and at 1 min intervals up to a total erosion time of 15 min. Scanning electron microscopic (SEM) analysis was performed in lased samples (n = 3). Data were statistically analysed by one-way ANOVA (p < 0.05) and Dunnett's post-hoc tests. Results: Calcium and phosphate release were significantly reduced by a maximum of 20% over time in samples irradiated with 0.4 J/cm(2) (200 mu s) at 450 Hz. Short-time reduction of calcium loss (<= 1.5 min) could be also achieved by irradiation with 0.7 J/cm(2) (300 mu s) at 200 and 300 Hz. Both parameters revealed surface modification. Conclusions: A set of CO2 laser parameters was found that could significantly reduce enamel mineral loss (20%) under in vitro erosive conditions. However, as all parameters also caused surface cracking, they are not recommended for clinical use.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this manuscript, an automatic setup for screening of microcystins in surface waters by employing photometric detection is described. Microcystins are toxins delivered by cyanobacteria within an aquatic environment, which have been considered strongly poisonous for humans. For that reason, the World Health Organization (WHO) has proposed a provisional guideline value for drinking water of 1 mu g L-1. In this work, we developed an automated equipment setup, which allows the screening of water for concentration of microcystins below 0.1 mu g V. The photometric method was based on the enzyme-linked immunosorbent assay (ELISA) and the analytical signal was monitored at 458 nm using a homemade LED-based photometer. The proposed system was employed for the detection of microcystins in rivers and lakes waters. Accuracy was assessed by processing samples using a reference method and applying the paired t-test between results. No significant difference at the 95% confidence level was observed. Other useful features including a linear response ranging from 0.05 up to 2.00 mu g L-1 (R-2 =0.999) and a detection limit of 0.03 mu g L-1 microcystins were achieved. (C) 2011 Elsevier B.V. All rights reserved.