871 resultados para alternative


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: The aim of this literature review, performed within the framework of the Swiss governmental Program of Evaluation of Complementary Medicine (PEK), was to investigate costs of complementary and alternative medicine (CAM). Materials and Methods: A systematic literature search was conducted in 11 electronic databases. All retrieved titles and reference lists were also hand-searched. Results: 38 publications were found: 23 on CAM of various definitions (medical and non-medical practitioners, over-the-counter products), 13 on homeopathy, 2 on phytotherapy. Studies investigated different kinds of costs (direct or indirect) and used different methods (prospective or retrospective questionnaires, data analyses, cost-effectiveness models). Most studies report 'out of pocket' costs, because CAM is usually not covered by health insurance. Costs per CAM-treatment / patient / month were AUD 7-66, CAD 250 and GBP 13.62 +/- 1.61. Costs per treatment were EUR 205 (range: 15-1,278), USD 414 +/- 269 and USD 1,127. In two analyses phytotherapy proved to be cost-effective. One study revealed a reduction of 1.5 days of absenteeism from work in the CAM group compared to conventionally treated patients. Another study, performed by a health insurance company reported a slight increase in direct costs for CAM. Costs for CAM covered by insurance companies amounted to approximately 0.2-0.5% of the total healthcare budget (Switzerland, 2003). Publications had several limitations, e.g. efficacy of therapies was rarely reported. As compared to conventional patients, CAM patients tend to cause lower costs. Conclusion: Results suggest lower costs for CAM than for conventional patients, but the limited methodological quality lowers the significance of the available data. Further well-designed studies and models are required.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: The objective was to study the effects of a novel lung volume optimization procedure (LVOP) using high-frequency oscillatory ventilation (HFOV) upon gas exchange, the transpulmonary pressure (TPP), and hemodynamics in a porcine model of surfactant depletion. METHODS: With institutional review board approval, the hemodynamics, blood gas analysis, TPP, and pulmonary shunt fraction were obtained in six anesthetized pigs before and after saline lung lavage. Measurements were acquired during pressure-controlled ventilation (PCV) prior to and after lung damage, and during a LVOP with HFOV. The LVOP comprised a recruitment maneuver with a continuous distending pressure (CDP) of 45 mbar for 2.5 minutes, and a stepwise decrease of the CDP (5 mbar every 5 minute) from 45 to 20 mbar. The TPP level was identified during the decrease in CDP, which assured a change of the PaO2/FIO2 ratio < 25% compared with maximum lung recruitment at CDP of 45 mbar (CDP45). Data are presented as the median (25th-75th percentile); differences between measurements are determined by Friedman repeated-measures analysis on ranks and multiple comparisons (Tukey's test). The level of significance was set at P < 0.05. RESULTS: The PaO2/FiO2 ratio increased from 99.1 (56.2-128) Torr at PCV post-lavage to 621 (619.4-660.3) Torr at CDP45 (CDP45) (P < 0.031). The pulmonary shunt fraction decreased from 51.8% (49-55%) at PCV post-lavage to 1.03% (0.4-3%) at CDP45 (P < 0.05). The cardiac output and stroke volume decreased at CDP45 (P < 0.05) compared with PCV, whereas the heart rate, mean arterial pressure, and intrathoracic blood volume remained unchanged. A TPP of 25.5 (17-32) mbar was required to preserve a difference in PaO2/FIO2 ratio < 25% related to CDP45; this TPP was achieved at a CDP of 35 (25-40) mbar. CONCLUSION: This HFOV protocol is easy to perform, and allows a fast determination of an adequate TPP level that preserves oxygenation. Systemic hemodynamics, as a measure of safety, showed no relevant deterioration throughout the procedure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: The evaluation of hepatic size is a daily question in abdominal ultrasound, especially to determine the presence of hepatomegaly. In the literature, different methods of measurement are described, mostly as a subcostal measured organ diameter in one direction. This method has its limits in patients with obesity, accumulation of abdominal gas or in uncooperative patients (lack of coordinative respiration) so that alternative measurements are necessary. METHODS: In 241 patients hepatic size was first measured in two conventional sections: midclavicular line (MCL) and anterior axillary line (AAL). Additionally, we measured the organs in midaxillary line craniocaudal (MAL) by determination of the cranio-caudal diameter. In 58 patients additional computed tomography was performed due to special diagnostical reasons so that liver size in MCL could be revealed and compared with ultrasonographical values. RESULTS: The mean value in MCL was 10.7 +/- 2.1 cm measured by ultrasound, 11.4 +/- 3.7 cm measured by computed tomography, 14.0 +/- 1.9 cm in AAL and 14.9 +/- 2.0 cm in MAL. In 5% of the cases the liver could not be measured in the conventional subcostal sections due to obesity or masking by gas, but this was possible in MAL. CONCLUSIONS: We revealed a good correlation of liver size in MCL between ultrasound and computed tomography, as well as in the measurement of AAL and MAL diameters. However, even in cases with difficult subcostal approach intercostal diameters allow for an accurate determination of hepatic size.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: The purpose of this study was to review the diagnosis on MRI and radiography of 24 renal transplant recipients with hip pain suspicious for avascular necrosis and to investigate whether there is an association between kidney transplant patients with end-stage renal disease and symptomatic gluteus minimus and medius tendon abnormality. CONCLUSION: Symptomatic gluteus minimus and medius tendon lesions and abnormalities can occur in renal allograft recipients. The MRI findings of this entity allow an alternative diagnosis in this patient population.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An optimal multiple testing procedure is identified for linear hypotheses under the general linear model, maximizing the expected number of false null hypotheses rejected at any significance level. The optimal procedure depends on the unknown data-generating distribution, but can be consistently estimated. Drawing information together across many hypotheses, the estimated optimal procedure provides an empirical alternative hypothesis by adapting to underlying patterns of departure from the null. Proposed multiple testing procedures based on the empirical alternative are evaluated through simulations and an application to gene expression microarray data. Compared to a standard multiple testing procedure, it is not unusual for use of an empirical alternative hypothesis to increase by 50% or more the number of true positives identified at a given significance level.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Acute thrombotic arterial occlusion is the leading cause of morbidity and mortality in the Western world. Von Willebrand factor is thought to be the only indispensable adhesive substrate to promote thrombus formation in high shear environments. We found that thrombospondin-1, a glycoprotein enriched in arteriosclerotic plaques, might function as an alternative substrate for thrombus formation. Platelets adhered to thrombospondin-1 in a shear dependent manner with an optimum shear as found in stenosed arteries. Adhesion is extremely firm, with no detachment of platelets up to a shear rate of 4000 s(-1). Experiments using platelets from a patient completely lacking von Willebrand factor showed that von Willebrand factor is not involved in platelet binding to thrombospondin-1. Platelet adhesion to thrombospondin-1 is not mediated via beta3-integrins or GPIa. CD36 partially mediates the adhesion of pre-activated platelets. We identified GPIb as high shear adhesion-receptor for thrombospondin-1. Soluble GPIb, as well as antibodies against the GPIb, blocked platelet adhesion almost completely. The new discovered thrombospondin-1-GPIb adhesion axis under arterial shear conditions might be important, not only during thrombus formation but also for pathological processes where other cells bind to the endothelium or subendothelium, including arteriosclerosis, inflammation and tumor metastasis, and a promising therapeutic target.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

REASON FOR PERFORMING STUDY: In Europe the incidence of botulism in horses has increased in the last decade due to the growing popularity of haylage feeding. Recombinant vaccines are safer and less expensive to produce and are generally better tolerated than toxoids. OBJECTIVES: To investigate whether the recombinant C-terminal half of the heavy chain of the botulinum neurotoxin C (Hc BoNT/C) in combination with an immunstimulatory adjuvant is an appropriate vaccine candidate for horses by testing its efficacy to induce neutralising antibodies and by comparing its immunogenic properties and adverse reactions to a commercial toxoid vaccine. Formation of oedema and local pain reactions were assessed. ELISA and Western blot assay against Hc BoNT/C and testing of neutralising antibody induction in a mouse protection assay were used to evaluate the immune response. RESULTS: With the recombinant vaccine, only minor local swelling with full recovery after 5 days was noted after brisket injections. The toxoid vaccine produced local, painful reactions with longer recovery periods of up to 2 weeks. Horses vaccinated with either vaccine induced neutralising antibodies after the second booster vaccination, while seroconversion on ELISA and Western blot to Hc BoNT/C was apparent after the first recombinant vaccination, and at various time points in the vaccination schedule in horses that received commercial toxoid vaccine. CONCLUSION: The recombinant vaccine showed fewer adverse reactions compared to the only commercially available vaccine but induced similar concentrations of neutralising antibodies. There was no correlation between the serological response to Hc BoNT/C and the neutralising capacity of serum. POTENTIAL RELEVANCE: Recombinant Hc BoNT/C is an appropriate vaccine candidate to stimulate production of neutralising antibodies against botulinum neurotoxin C in horses and creates only minor local reactions at the injection site.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Bacterial virulence can only be assessed by confronting bacteria with a host. Here, we present a new simple assay to evaluate Aeromonas virulence, making use of Dictyostelium amoebae as an alternative host model. This assay can be modulated to assess virulence of very different Aeromonas species.