970 resultados para Switching circuits
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Pós-graduação em Odontologia - FOA
Resumo:
This work aims at presenting a no-break system for microcomputers using ultracapacitors in replacement of the conventional chemical batteries. We analyzed the most relevant data about average power consumption of microcomputers, electrical and mechanical characteristics of ultracapacitors and operation of no-break power circuits, to propose a configuration capable of working properly with a microcomputer switching mode power supply. Our solution was a sixteen-component ultracapacitor bank, with a total capacitance of 350 F and voltage of 10.8 V, adequate to integrate a low-capacity no-break system, capable of feeding a load of 180 Wh, during 75 s. Our proposed no-break increases the reliability of microcomputers by reducing the probability of user data losses, in case of a power grid failure, offering, so, a high benefit-cost ratio. The replacement of the battery by ultracapacitors allows a quick no-break recharge and low maintenance costs, since these modern components have a lifetime longer than the batteries. Moreover, this solution reduces the environmental impact and eliminates the constant recharge of the energy storage device.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
The objective of this work is to analyze the viability of incorporation in a microcomputer box of a nobreak with an ultracapacitor as energy storage device, substituting the conventional chemical battery. An advantage of this inclusion is cost reduction because a specific metallic or plastic frame won’t be necessary to protect the components of the nobreak; the microcomputer metallic frame offers the necessary protection for both equipments. Moreover, a large quantity of internal space of microcomputers box isn’t used, and is possible to use it to wrap up the nobreak. This work uses data about average power consumption of microcomputers; operation of switching mode power supplies for microcomputers; electrical and mechanical characteristics of ultracapacitors and operation of power circuits of nobreaks, with the purpose of present a study of energy storage capacity that an ultracapacitor should have to allow a safe switching off of a microcomputer in case of electrical network fail. It was noticed that the use of ultracapacitors is feasible to feed an 180 W load for 75 s, using a capacitive bank with sixteen ultracapacitors, with a total capacitance of 350 F and voltage of 10,8 V. The use of the proposed nobreak increases the reliability of the microcomputer by reducing the probability of user data losses in case of an electrical network fail, offering a high cost/benefit product. The substitution of the battery by an ultracapacitor allows a quick nobreak recharge, with low maintenance costs, since ultracapacitors have a lifetime bigger than batteries; beyond reducing the environmental impact, because they don’t use potentially toxic chemical compounds
Resumo:
Due to concerns about rational use of energy, several alternative technologies of power generation appeared, including the conversion of solar energy into electrical energy by photovoltaic panels. In low-income households, the refrigerator represents considerable impact on the electric bill, since it requires constant power given its use in food preservation. It is possible to reduce this share, with the use of an alternative energy source. This work presents a timed switching electronic system, which allows commercial equipment that is not affected by short interruptions in the power supply to use a photovoltaic panel as a source of alternative energy, which usually do not provide energy continuously. Switching is made automatically in case of low incidence of sunlight, and without any form of energy storage. Between each switching, there is a dead time without power supply, therefore preventing the use of synchronizers circuits between the photovoltaic panel and the public power grid. A circuit containing a 80C31 microcontroller is used to control the system’s switching. The photovoltaic panel’s voltage inverter is in H bridge configuration, and is also controlled by the microcontroller through Pulse Width Modulation, which makes use of preprogrammed tables to generate the control signals of the power transistors. Through the use of software simulations, the proposed system was tested, which is capable of supplying intermittent single-phase loads. The simulations indicates that the project developed in this paper can be assembled into a prototype and be tested under real operating conditions, as long as the scaling of components, the characteristics of the photovoltaic panel to be used, and the project involved load are taken into account
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Odontologia - FOA
Resumo:
This in vitro study evaluated the effect of mechanical cycling on the torque of retaining screw in external hexagon implants with platform switching (PS), regular platform (RP) and wide platform (WP). A total of 30 specimens were equally divided into 3 groups: PS, PR and WP. Each specimen was prepared with implants: 3.75 x 10 mm for RP group and 5.0x10 mm for PS and WP groups and its respective abutment with 32 Ncm torque. All groups were subjected to 106 cycles with 100 N (corresponding to about 40 months of chewing). The results were obtained with the reverse torque of each specimen and data were evaluated using ANOVA and Tukey test (p<0.05). The PS group showed statistically significant difference in screw removal torque (30.06±5.42) compared with RP (23.75±2.76) and WP (21.32±3.53) (p<0.05) groups; the RP and WP groups showed no statistically significant difference between them. It was concluded that the PS group showed higher reverse torque value, suggesting lower susceptibility of the abutment screw loosening.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
PURPOSE: In view of reports in the literature on the benefits achieved with the use of platform switching, described as the use of an implant with a larger diameter than the abutment diameter, the goal being to prevent the (previously) normal bone loss down to the first thread that occurs around most implants, thus enhancing soft tissue aesthetics and stability and the need for implant inclination due to bone anatomy in some cases, the aim of this study was to evaluate bone stress distribution on peri-implant bone, by using three-dimensional finite element analysis to simulate the influence of implants with different abutment angulations (0 and 15 degrees) in platform switching. METHODS: Four mathematical models of an implant-supported central incisor were created with varying abutment angulations: straight abutment (S1 and S2) and angulated abutment at 15 degrees (A1 and A2), submitted to 2 loading conditions (100 N): S1 and A1-oblique loading (45 degrees) and S2 and A2-axial loading, parallel to the long axis of the implant. Maximum (σmax) and minimum (σmin) principal stress values were obtained for cortical and trabecular bone. RESULTS: Models S1 and A1 showed higher σmax in cortical and trabecular bone when compared with S2 and A2. The highest σmax values (in MPa) in the cortical bone were found in S1 (28.5), followed by A1 (25.7), S2 (11.6), and A2 (5.15). For the trabecular bone, the highest σmax values were found in S1 (7.53), followed by A1 (2.87), S2 (2.85), and A2 (1.47). CONCLUSIONS: Implants with straight abutments generated the highest stress values in bone. In addition, this effect was potentiated when the load was applied obliquely.
Resumo:
The concept of switching platform is the use of an implant by platform wider than the abutment. Recently, researches have shown that this type of dental implant design tends to offer a higher preservation of crestal bone when compared to the traditional pattern of bone loss. The present study aims to perform a critical review on the switching platform concept establishing possible advantages of the technique. A search was performed on Medline/Pubmed about the topic “dental implant” and “platform switching”, and after applying inclusion criteria 40 studies were selected. The literature on longevity present prospective studies that show less bone loss, studies in biomechanics exhibit better or similar stress distribution around the bone crest, however, is not yet defined the role of the biological width. Thus, studies of longevity, and randomized prospective studies are of a great relevance to be performed in order to confirm the benefits of this technique and to establish a protocol indication. It is possible, based on this literature review, to conclude that longitudinal and randomized studies show that the platform switching implants have longevity and less bone loss. Biomechanically, the technique is possible.
Resumo:
This paper considers the problem of dedicated path-protection in wavelength-division multiplexed (WDM) mesh networks with waveband switching functionality under shared risk link group (SRLG) constraints. Two dedicated path protection schemes are proposed, namely the PBABL scheme and the MPABWL scheme. The PBABL scheme protects each working waveband-path through a backup waveband-path. The MPABWL scheme protects each working waveband-path by either a backup waveband-path or multiple backup lightpaths. Heuristic algorithms adopting random optimization technique are proposed for both the schemes. The performance of the two protection schemes is studied and compared. Simulation results show that both the heuristics can obtain optimum solutions and the MPABWL scheme leads to less switching and transmission costs than the PBABL scheme.
Resumo:
We investigate waveband switching (WBS) with different grouping strategies in wavelength-division multiplexing (WDM) mesh networks. End-to-end waveband switching (ETEWBS) and same-destination-intermediate waveband switching (SD-IT-WBS) are analyzed and compared in terms of blocking probability and cost savings. First, an analytical model for ETEWBS is proposed to determine the network blocking probability in a mesh network. For SD-IT-WBS, a simple waveband switching algorithm is presented. An analytical model to determine the network blocking probability is proposed for SD-IT-WBS based on the algorithm. The analytical results are validated by comparing with simulation results. Both results match well and show that ETE-WBS slightly outperforms SD-IT-WBS in terms of blocking probability. On the other hand, simulation results show that SD-IT-WBS outperforms ETE-WBS in terms of cost savings.