916 resultados para Rotarod Performance Test


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Over recent years, it has repeatedly been shown that optimal gaze strategies enhance motor control (e.g., Foulsham, 2015). However, little is known, whether, vice versa, visual performance can be improved by optimized motor control. Consequently, in two studies, we investigated visual performance as a function of motor control strategies and task parameters, respectively. In Experiment 1, 72 participants were tested on visual acuity (Landolt) and contrast sensitivity (Grating), while standing in two different postures (upright vs. squat) on a ZEPTOR-platform that vibrated at four different frequencies (0, 4, 8, 12 Hz). After each test, perceived exertion (Borg) was assessed. Significant interactions were revealed for both tests, Landolt: F(3,213)=13.25, p<.01, ηp2=.16, Grating: F(3,213)=4.27, p<.01, ηp2=.06, elucidating a larger loss of acuity/contrast sensitivity with increasing frequencies for the upright compared with the squat posture. For perceived exertion, however, a diametrical interaction for frequency was found for acuity, F(3,213)=7.45, p<.01, ηp2=.09, and contrast sensitivity, F(3,213)=7.08, p < .01, ηp2=.09, substantiating that the impaired visual performance cannot be attributed to exertion. Consequently, the squat posture could permit better head and, hence, gaze stabilization. In Experiment 2, 64 participants performed the same tests while standing in a squat position on a ski-simulator, which vibrated with two different frequencies (2.4, 3.6 Hz) and amplitudes (50, 100 mm) in a predictable or unpredictable manner. Control strategies were identified by tracking segmental motion, which allows to derive damping characteristics. Considerable main effects were found for frequency, all F’s(1,52)>10.31, all p’s<.01, all ηp2’s>.16, as well as, in the acuity test, for predictability, F(1,52)=10.31, p<.01, ηp2=.17, and by tendency for amplitude, F(1,52)=3.53, p=.06, ηp2=.06. A significant correlation between the damping amplitude in the knee joint and the performance drop in visual acuity, r=-.97, p<.001, again points towards the importance of motor control strategies to maintain optimal visual performance.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE To test whether sleep-deprived, healthy subjects who do not always signal spontaneously perceived sleepiness (SPS) before falling asleep during the Maintenance of Wakefulness Test (MWT) would do so in a driving simulator. METHODS Twenty-four healthy subjects (20-26 years old) underwent a MWT for 40 min and a driving simulator test for 1 h, before and after one night of sleep deprivation. Standard electroencephalography, electrooculography, submental electromyography, and face videography were recorded simultaneously to score wakefulness and sleep. Subjects were instructed to signal SPS as soon as they subjectively felt sleepy and to try to stay awake for as long as possible in every test. They were rewarded for both "appropriate" perception of SPS and staying awake for as long as possible. RESULTS After sleep deprivation, seven subjects (29%) did not signal SPS before falling asleep in the MWT, but all subjects signalled SPS before falling asleep in the driving simulator (p <0.004). CONCLUSIONS The previous results of an "inaccurate" SPS in the MWT were confirmed, and a perfect SPS was shown in the driving simulator. It was hypothesised that SPS is more accurate for tasks involving continuous feedback of performance, such as driving, compared to the less active situation of the MWT. Spontaneously perceived sleepiness in the MWT cannot be used to judge sleepiness perception while driving. Further studies are needed to define the accuracy of SPS in working tasks or occupations with minimal or no performance feedback.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This work applies higher order auxiliary excitation techniques to two types of quadrupole mass spectrometers (QMSs): commercial systems and spaceborne instruments. The operational settings of a circular rod geometry commercial system and an engineering test-bed for a hyperbolic rod geometry spaceborne instrument were matched, with the relative performance of each sensor characterized with and without applied excitation using isotopic measurements of Kr+. Each instrument was operated at the limit of the test electronics to determine the effect of auxiliary excitation on extending instrument capabilities. For the circular rod sensor, with applied excitation, a doubling of the mass resolution at 1% of peak transmission resulted from the elimination of the low-mass side peak tail typical of such rod geometries. The mass peak stability and ion rejection efficiency were also increased by factors of 2 and 10, respectively, with voltage scan lines passing through the center of stability islands formed from auxiliary excitation. Auxiliary excitation also resulted in factors of 6 and 2 in peak stability and ion rejection efficiency, respectively, for the hyperbolic rod sensor. These results not only have significant implications for the use of circular rod quadrupoles with applied excitation as a suitable replacement for traditional hyperbolic rod sensors, but also for extending the capabilities of existing hyperbolic rod QMSs for the next generation of spaceborne instruments and low-mass commercial systems.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We report on the developments of a neutron tomography setup at the instrument for prompt gamma-ray activation analysis (PGAA) at the Maier-Leibnitz Zentrum(MLZ). The recent developments are driven by the idea of combining the spatial information obtained with neutron tomography with the elemental information determined with PGAA, i.e. to further combine both techniques to an investigative technique called prompt gamma activation imaging (PGAI).At the PGAA instrument, a cold neutron flux of up to 6 x 1010 cm-2 s-1 (thermal equivalent) is available in the focus of an elliptically tapered neutron guide. In the reported experiments, the divergence of the neutron beam was investigated, the resolution of the installed detector system tested, and a proof-of-principle tomography experiment performed. In our study a formerly used camera box was upgraded with a better camera and an optical resolution of 8 line pairs/mm was achieved. The divergence of the neutron beam was measured by a systematic scan along the beam axis. Based on the acquired data, a neutron imaging setup with a L/D ratio of 200 was installed. The resolution of the setup was testedin combination with a gadolinium test target and different scintillator screens. The test target was irradiated at two positions to determine the maximum resolution and the resolution at the actual sample position. The performance of the installed tomography setup was demonstrated bya tomography experiment of an electric amplifier tube.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

AIM This study aimed to evaluate the effect of a digital learning tool on undergraduate dental students' performance in detecting dental caries using ICDAS. METHODS An experimental digital learning tool (DLT) was created using digital photographs of sound and carious teeth. Thirty-nine students were divided into three groups (n = 13) and each assessed 12 randomly allocated patients before and after learning strategies: G1, ICDAS e-learning program; G2, ICDAS e-learning program plus DLT; G3, no learning strategy. Students (n = 32) reassessed patients 2 weeks after training. RESULTS Comparing before and after the learning strategies, any difference in the values of specificity and area under the ROC curve for all groups was found. Sensitivity was statistically significantly higher for G1 and G2. Comparing the groups, G2 showed a significant increase in sensitivity at the D2 and D3 thresholds. Spearman's correlations with the gold standard before and after the learning strategy were 0.60 and 0.61 for G1, 0.57 and 0.63 for G2, and 0.54 and 0.54 for G3, respectively. The Wilcoxon test showed a statistically significant difference between the values obtained before and after learning strategies for G1 and G2. CONCLUSIONS Use of the DLT after the ICDAS e-learning program tended to increase the sensitivity of ICDAS used by undergraduate dental students. The DLT appeared to improve dental students' ability to use ICDAS.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to test a newly developed LED-based fluorescence device for approximal caries detection in vitro. We assembled 120 extracted molars without frank cavitations or fillings pairwise in order to create contact areas. The teeth were independently assessed by two examiners using visual caries detection (International Caries Detection and Assessment System, ICDAS), bitewing radiography (BW), laser fluorescence (LFpen), and LED fluorescence (Midwest Caries I.D., MW). The measurements were repeated at least 1 week later. The diagnostic performance was calculated with Bayesian analyses. Post-test probabilities were calculated in order to judge the diagnostic performance of combined methods. Reliability analyses were performed using kappa statistics for nominal data and intraclass correlation (ICC) for absolute data. Histology served as the gold standard. Sensitivities/specificities at the enamel threshold were 0.33/0.84 for ICDAS, 0.23/0.86 for BW, 0.47/0.78 for LFpen, and 0.32/0.87 for MW. Sensitivities/specificities at the dentine threshold were 0.04/0.89 for ICDAS, 0.27/0.94 for BW, 0.39/0.84 for LFpen, and 0.07/0.96 for MW. Reliability data were fair to moderate for MW and good for BW and LFpen. The combination of ICDAS and radiography yielded the best diagnostic performance (post-test probability of 0.73 at the dentine threshold). The newly developed LED device is not able to be recommended for approximal caries detection. There might be too much signal loss during signal transduction from the occlusal aspect to the proximal lesion site and the reverse.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

entral European grasslands vary widely in productivity and in mowing and grazing regimes. The resulting differences in competition and heterogeneity among grasslands might have direct effects on plants, but might also affect the growth and morphology of their offspring through maternal effects or adaptive evolution. To test for such transgenerational effects, we grew plants of the clonal herb Trifolium repens from seeds collected in 58 grassland sites differing in productivity and mowing and grazing intensities in different treatments: without competition, with homogeneous competition, and with heterogeneous competition. In the competition-free treatment, T. repens from more productive, less frequently mown, and less intensively grazed sites produced more vegetative offspring, but this was not the case in the other treatments. When grown among or in close proximity to competitors, T. repens plants did not show preferential growth towards open spaces (i.e., no horizontal foraging), but did show strong vertical foraging by petiole elongation. In the homogeneous competition treatment, petiole length increased with the productivity of the parental site, but this was not the case in the heterogeneous competition treatment. Moreover, petiole length increased with mowing frequency and grazing intensity of the parental site in all but the homogeneous competition treatment. In summary, although the expression of differences between plants from sites with different productivities and land-use intensities depended on the experimental treatment, our findings imply that there are transgenerational effects of land use on the morphology and performance of T. repens.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND The aim of newborn screening (NBS) for CF is to detect children with 'classic' CF where early treatment is possible and improves prognosis. Children with inconclusive CF diagnosis (CFSPID) should not be detected, as there is no evidence for improvement through early treatment. No algorithm in current NBS guidelines explains what to do when sweat test (ST) fails. This study compares the performance of three different algorithms for further diagnostic evaluations when first ST is unsuccessful, regarding the numbers of children detected with CF and CFSPID, and the time until a definite diagnosis. METHODS In Switzerland, CF-NBS was introduced in January 2011 using an IRT-DNA-IRT algorithm followed by a ST. In children, in whom ST was not possible (no or insufficient sweat), 3 different protocols were applied between 2011 and 2014: in 2011, ST was repeated until it was successful (protocol A), in 2012 we proceeded directly to diagnostic DNA testing (protocol B), and 2013-2014, fecal elastase (FE) was measured in the stool, in order to determine a pancreas insufficiency needing immediate treatment (protocol C). RESULTS The ratio CF:CFSPID was 7:1 (27/4) with protocol A, 2:1 (22/10) with protocol B, and 14:1 (54/4) with protocol C. The mean time to definite diagnosis was significantly shorter with protocol C (33days) compared to protocol A or B (42 and 40days; p=0.014 compared to A, and p=0.036 compared to B). CONCLUSIONS The algorithm for the diagnostic part of the newborn screening used in the CF centers is important and affects the performance of a CF-NBS program with regard to the ratio CF:CFSPID and the time until definite diagnosis. Our results suggest to include FE after initial sweat test failure in the CF-NBS guidelines to keep the proportion of CFSPID low and the time until definite diagnosis short.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The relationships among animal form, function and performance are complex, and vary across environments. Therefore, it can be difficult to identify morphological and/or physiological traits responsible for enhancing performance in a given habitat. In fishes, differences in swimming performance across water flow gradients are related to morphological variation among and within species. However, physiological traits related to performance have been less well studied. We experimentally reared juvenile damselfish, Acanthochromis polyacanthus, under different water flow regimes to test 1) whether aspects of swimming physiology and morphology show plastic responses to water flow, 2) whether trait divergence correlates with swimming performance and 3) whether flow environment relates to performance differences observed in wild fish. We found that maximum metabolic rate, aerobic scope and blood haematocrit were higher in wave-reared fish compared to fish reared in low water flow. However, pectoral fin shape, which tends to correlate with sustained swimming performance, did not differ between rearing treatments or collection sites. Maximum metabolic rate was the best overall predictor of individual swimming performance; fin shape and fish total length were 3.3 and 3.7 times less likely than maximum metabolic rate to explain differences in critical swimming speed. Performance differences induced in fish reared in different flow environments were less pronounced than in wild fish but similar in direction. Our results suggest that exposure to water motion induces plastic physiological changes which enhance swimming performance in A. polyacanthus. Thus, functional relationships between fish morphology and performance across flow habitats should also consider differences in physiology.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to examine whether athletes differ from nonathletes regarding their mental rotation performance. Furthermore, it investigated whether athletes doing sports requiring distinguishable levels of mental rotation (orienteering, gymnastics, running), as well as varying with respect to having an egocentric (gymnastics) or an allocentric perspective (orienteering), differ from each other. Therefore, the Mental Rotations Test (MRT) was carried out with 20 orienteers, 20 gymnasts, 20 runners, and 20 nonathletes. The results indicate large differences in mental rotation performance, with those actively doing sports outperforming the nonathletes. Analyses for the specific groups showed that orienteers and gymnasts differed from the nonathletes, whereas endurance runners did not. Contrary to expectations, the mental rotation performance of gymnasts did not differ from that of orienteers. This study also revealed gender differences in favor of men. Implications regarding a differentiated view of the connection between specific sports and mental rotation performance are discussed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

INTRODUCTION The neural correlates of impaired performance of gestures are currently unclear. Lesion studies showed variable involvement of the ventro-dorsal stream particularly left inferior frontal gyrus (IFG) in gesture performance on command. However, findings cannot be easily generalized as lesions may be biased by the architecture of vascular supply and involve brain areas beyond the critical region. The neuropsychiatric syndrome of schizophrenia shares apraxic-like errors and altered brain structure without macroanatomic lesions. Schizophrenia may therefore qualify as a model disorder to test neural correlates of gesture impairments. METHODS We included 45 schizophrenia patients and 44 healthy controls in the study to investigate the structural brain correlates of defective gesturing in schizophrenia using voxel based morphometry. Gestures were tested in two domains: meaningful gestures (transitive and intransitive) on verbal command and imitation of meaningless gestures. Cut-off scores were used to separate patients with deficits, patients without deficits and controls. Group differences in gray matter (GM) volume were explored in an ANCOVA. RESULTS Patients performed poorer than controls in each gesture category (p < .001). Patients with deficits in producing meaningful gestures on command had reduced GM predominantly in left IFG, with additional involvement of right insula and anterior cingulate cortex. Patients with deficits differed from patients without deficits in right insula, inferior parietal lobe (IPL) and superior temporal gyrus. CONCLUSIONS Impaired performance of meaningful gestures on command was linked to volume loss predominantly in the praxis network in schizophrenia. Thus, the behavioral similarities between apraxia and schizophrenia are paralleled by structural alterations. However, few associations between behavioral impairment and structural brain alterations appear specific to schizophrenia.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The main goal of this study was to relate physical changes in image quality measured by Modulation Transfer Function (MTF) to diagnostic accuracy.^ One Hundred and Fifty Kodak Min-R screen/film combination conventional craniocaudal mammograms obtained with the Pfizer Microfocus Mammographic system were selected from the files of the Department of Radiology, at M.D. Anderson Hospital and Tumor Institute.^ The mammograms included 88 cases with a variety of benign diagnosis and 62 cases with a variety of malignant biopsy diagnosis. The average age of the patient population was 55 years old. 70 cases presented calcifications with 30 cases having calcifications smaller than 0.5mm. 46 cases presented irregular bordered masses larger than 1 cm. 30 cases presented smooth bordered masses with 20 larger than 1 cm.^ Four separated copies of the original images were made each having a different change in the MTF using a defocusing technique whereby copies of the original were obtained by light exposure through different thicknesses (spacing) of transparent film base.^ The mammograms were randomized, and evaluated by three experienced mammographers for the degree of visibility of various anatomical breast structures and pathological lesions (masses and calicifications), subjective image quality, and mammographic interpretation.^ 3,000 separate evaluations were anayzed by several statistical techniques including Receiver Operating Characteristic curve analysis, McNemar test for differences between proportions and the Landis et al. method of agreement weighted kappa for ordinal categorical data.^ Results from the statistical analysis show: (1) There were no statistical significant differences in the diagnostic accuracy of the observers when diagnosing from mammograms with the same MTF. (2) There were no statistically significant differences in diagnostic accuracy for each observer when diagnosing from mammograms with the different MTF's used in the study. (3) There statistical significant differences in detail visibility between the copies and the originals. Detail visibility was better in the originals. (4) Feature interpretations were not significantly different between the originals and the copies. (5) Perception of image quality did not affect image interpretation.^ Continuation and improvement of this research ca be accomplished by: using a case population more sensitive to MTF changes, i.e., asymptomatic women with minimum breast cancer, more observers (including less experienced radiologists and experienced technologists) must collaborate in the study, and using a minimum of 200 benign and 200 malignant cases.^

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Dua and Miller (1996) created leading and coincident employment indexes for the state of Connecticut, following Moore's (1981) work at the national level. The performance of the Dua-Miller indexes following the recession of the early 1990s fell short of expectations. This paper performs two tasks. First, it describes the process of revising the Connecticut Coincident and Leading Employment Indexes. Second, it analyzes the statistical properties and performance of the new indexes by comparing the lead profiles of the new and old indexes as well as their out-of-sample forecasting performance, using the Bayesian Vector Autoregressive (BVAR) method. The new indexes show improved performance in dating employment cycle chronologies. The lead profile test demonstrates that superiority in a rigorous, non-parametric statistic fashion. The mixed evidence on the BVAR forecasting experiments illustrates the truth in the Granger and Newbold (1986) caution that leading indexes properly predict cycle turning points and do not necessarily provide accurate forecasts except at turning points, a view that our results support.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The intensification of consequential testing situations is associated with an increase in anxiety among American students (Casbarro, 2005). Test anxiety can have negative effects on student test performance (Everson, Millsap, & Rodriguez, 1991). If test anxiety has the potential to decrease students’ test scores, it becomes a factor that can threaten the validity of any inferences drawn between test scores and student progress (Cizek & Burg, 2006). There are several factors that relate closely to test anxiety (Cizek & Burg, 2006). Variables of key influence include gender, socioeconomic status, and teacher-manifested anxiety (Hembree, 1988). Another influence upon test anxiety is students’ participation in academic support programs to prepare them for exit examinations. The purpose of this study was to examine the relationship between 10th grade high school student gender, socioeconomic status, perceived teacher anxiety, and student preparedness with levels of the Massachusetts Comprehensive Assessment System (MCAS) test anxiety. It appears that few studies have examined levels of high school test anxiety in regards to this specific high-stakes MCAS exit exam required for high school graduation. A two-phase sequential mixed-methods research design was used to survey (N=156) 10th grade students represented by a sampling of (n=80) students with low socioeconomic status and (n=76) students with high socioeconomic status regarding their levels of test anxiety in relation to upcoming MCAS testing. A multiple regression analysis was used to measure the relationship between the predictor variables (gender, socioeconomic status, perceived teacher anxiety, and student preparedness) with the criterion variable of student test anxiety using the Test Anxiety Inventory (TAI). Personal interviews with (n=20) volunteer students provided rich explanations of students’ academic self-efficacy, their perceptions of their performance on the upcoming MCAS exam, and their use of strategies to reduce their levels of test anxiety. Personal interviews with (n=12) volunteer school administrators and teachers provided descriptions of their perceptions of how test anxiety affected their students’ performance. A major quantitative finding of this study was that the variables of student socioeconomic status and student ratings of teacher anxiety accounted for the variance in students’ levels of surveyed test anxiety (R2 = .06, p = .033, small to medium effect size). These results indicate that different student populations vary in their readiness skills to successfully participate in consequential testing situations. Consequently, high-test anxious students would require emotional preparation as well as academic preparation when confronting high-stakes testing. The results have the potential to re-shape the format of schools’ MCAS test preparation efforts.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The objectives of this research were (1) to study the effect of contact pressure, compression time, and liquid (moisture content of the fabric) on the transfer by sliding contact of non-fixed surface contamination to protective clothing constructed from uncoated, woven fabrics, (2) to study the effect of contact pressure, compression time, and liquid content on the subsequent penetration through the fabric, and (3) to determine if varying the type of contaminant changes the effect of contact pressure, compression time, and liquid content on the transfer by sliding contact and penetration of non-fixed surface contamination. ^ It was found that the combined influence of the liquid (moisture content of the fabric), load (contact pressure), compression time, and their interactions significantly influenced the penetration of all three test agents, sucrose- 14C, triolein-3H, and starch-14C through 100% cotton fabric. The combined influence of the statistically significant main effects and their interactions increased the penetration of triolein- 3H by 32,548%, sucrose-14C by 7,006%, and starch- 14C by 1,900%. ^