999 resultados para Ressonância Magnética
Resumo:
Medical Physics has been reaching an important role among several lines in Science, providing means for the improvement of several theories and procedures. Currently, its main application is related with the use of ionizing radiations, specially, in treatment procedures such as Radiotherapy. Radiosurgery is a Radiotherapy technique which consists in administering a single tumoricidal dose of radiation exclusively to the tumorous lesion. It becomes then an interesting alternative to surgical treatment, mainly in cerebral metastases, which are the most frequent cerebral tumors in the central nervous system. The radio neurosurgical team works out a planning for the Radiosurgery treatment, aiming for obtaining an appropriate ideal treatment for each case. For the working out of this treatment planning, Computed Tomography images of the region to be treated are obtained, digitalized and later, fused with nuclear magnetic resonance images. Through these images, critical structures, organs at risk and lesions are localized. After this, calculations are made to determine three-dimensional positions of isocenters, isodose curves, prescribed dose, collimators sizes, position, numbers and respective weight of isocentric conformal fields, and others. The treatment planning is commonly based in desired levels of dose for specific types of tumors and organs at risk concerning the irradiated region. Theses levels of dose are chosen in a way that a high probability of cure may be achieved and meanwhile, that the probability of complications, in whichever organ at risk, may be minimal. Thus, many researches have been carried out, showing that mathematical techniques may help to obtain an optimal planning for the treatment of cerebral metastases. Among the methods of optimization in the study...(Complete abstract click electronic access below)
Resumo:
The Hyperadrenocorticism is a disease that occur in dogs between mead to old age, is associated with the higher level of glucocorticoid that result in a corporal reaction. To make a diagnostic of this disease is necessary have a good history and physical examination, the principals complains of the proprietary are polyuria, polydipsia and polyphagia, in some times abdominal enlargement and lethargy. In the physical examination is observed this abdominal enlargement, hepatomegaly, alopecia, in some cases pyoderma and difficult respiratory. From this documents is possible determinate the differential diagnostics and with the tests find the diagnostic of the disease that the animal have. The base methods are hemogram, biochemical, urinalysis, radiographs and ultrasonography it’s possible do tomography and magnetic resonance too. There are confirmation methods too, they are very important, because the others not have documents necessary for the final diagnostic. Those are Urine cortisol to creatinine ratio, dexamethasone suppression test with high dose or low dose and ACTH stimulation test. Despite those tests have high sensibility and specificity, they can result in false positive or false negative, this is one of the causes to do the base methods and together make the veterinary doctor find the solution of the diagnostic and do the adequate treatment
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Pós-graduação em Química - IQ
Resumo:
Pós-graduação em Química - IQ
Resumo:
The technology, through the advent of new equipments that allow imaging exams, has helped very much in the diagnosis and prognosis of diseases in Dentistry. The use of informatics, in general, in the manufacture of clinical reports is increasingly present in the dental offices. The legal validity of these systems is questioned, and is matter of discussion. This work makes considerations about Imageology or Diagnostic by image, a new area that is appearing on Dentistry. Among other exams, there are: digital radiography, tomography, computed tomography, artomography, magnetic resonance, computed cefalometry and ultra-sonography. It permits the professional to obtain a better diagnostic, and to the patient, the visualization of his problem and treatment. A survey on the possibilities of using informatics in Dentistry, particularly in Radiology, was also carried out, as well as the legal aspects, which are in accordance with the Law 8.935/94, what guarantees its practicability. Digital Certification is a mechanism that provides legal validity to documents and, as such, to radiographic images and others. It is a procedure that the dentist should take to ensure that he/she has safeguarded the judicial proofs that may be necessary in an eventual demand.
Resumo:
Pós-graduação em Ciência dos Materiais - FEIS
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Ciência dos Materiais - FEIS
Resumo:
Background: To establish the best methodology for diagnosis and management of patients with solid and complex renal masses by comparing the costs and benefits of different imaging methods and to improve differential diagnosis of these benign and malignant lesions, particularly by investigating tumour calcifications. Methods: We performed a prospective study on 31 patients with solid or complex masses by submitting them to Abdominal Ultrasonography (US), Doppler Ultrasonography of the renal mass (US Dop), Computed Tomography (CT), and Magnetic Resonance Imaging (MRI). Results: We found 28 patients with malignant and three with benign masses. Of the 28 malignant, 17 showed calcifications at CT; 16 central and one was of the pure peripheral curvilinear type (egg shell). Excretory Urography (IVP) had a significantly lower detection rate for central calcifications than both US and CT. Benign and malignant masses appeared as described in literature, with US, CT and MRI showing high sensitivity and specificity in renal tumor diagnosis. The exception was US Dop where we obtained lower sensitivity for the characterization of malignant tumor flow. Conclusions: In this series we were surprised to find that CT revealed central calcifications in 51.6% of patients, all with malignant lesions, while, literature reports a frequency of calcification in renal cell carcinoma between 8 and 22%, in studies using abdominal films and EU (IVP). This finding is of great importance when we consider that these calcifications occur particularly in malignant neoplasms. As a result of comparing these different imaging methods we have developed a better methodology for renal tumor investigation.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Bases Gerais da Cirurgia - FMB
Resumo:
Using the sol-gel process, organic-inorganic hybrid coatings were synthesized by incorporation of different concentrations of functionalized carbon nanotubes, to improve their mechanical strength and thermal resistance without changing its passivation character. The siloxane-PMMA hybrids were prepared by radical polymerization of methyl methacrylate (MMA) with 3-methacryloxipropiltrimethoxisilane (MPTS) using the thermal initiator benzoyl peroxide (BPO), followed by acid catalyzed hydrolysis and condensation of tetraethoxysilane (TEOS). The analysis of pristine and functionalized carbon nanotubes was carried out using Scanning Electron Microscopy, X-ray Photoelectron Spectroscopy and Raman Spectroscopy. Structural analysis of hybrids was performed by Nuclear Magnetic Resonance, Atomic Force Microscopy and Raman Spectroscopy. For analysis of mechanical strength and thermal stability were performed mechanical compression tests and thermogravimetric analysis, respectively. Electrochemical Impedance Spectroscopy was used to evaluate the corrosion resistance in saline environment. The results showed an effective functionalization of carbon nanotubes with carboxyl groups and conservation of its structure. The hybrids showed high siloxane network connectivity and roughness of approximately 0.3 nm. The incorporation of carbon nanotubes in the hybrid matrix did not change significantly their thermal stability. Samples containing carbon nanotubes exhibit good corrosion resistance (on the order of MΩ in saline environment), but the lack of complete dispersion of carbon nanotubes in the hybrid, resulted in a loss of mechanical and corrosion resistance compared to hybrid matrix.