979 resultados para Repeated Load Triaxial (RLT) test
Resumo:
This paper extends the standard industrial organization models of repeated interaction between firms by incorporating preferences for reciprocity. A reciprocal firm responds to unkind behavior of rivals with unkind actions (destructive reciprocity), while at the same time, it responds to kind behavior of rivals with kind actions (constructive reciprocity). The main finding of the paper is that, for plausible perceptions of fairness, preferences for reciprocity facilitate collusion in infinitely repeated market games, that is, the critical discount rate at wish collusion can be sustained tends to be lower when firms have preferences for reciprocity than when firms are selfish. The paper also finds that the best collusive outcome that can be sustained in the infinitely repeated Cournot game with reciprocal firms is worse for consumers than the best collusive outcome that can be sustained in the infinitely repeated Cournot game with selfish firms.
Resumo:
The present open pilot study was conducted to assess the efficacy of azithromycin for the treatment of patients with cutaneous leishmaniasis in Araçuaí and Varzelândia, MG. Twenty-four patients with less of six months of disease evolution were treated after clinical examination, Montenegro test and a biopsy. The treatment schemes consisted of oral doses of 500 mg per day for 3, 5 and 10 days and of 1000 mg for two days. A clinical control was performed monthly and treatment cycles were repeated when necessary until full reepithelialization of the lesions. On the occasion of the final evaluation, 20 patients had completed the study and 17 of them (85%) were cured. The time to obtain a cure was 60 days ifor 6 (30%) patients, 90 days for 7 (35%), and 120 for 4 (20%). The three patients with treatment failure received a pentavalent antimonial for 20 days. No adverse reactions to the medication were observed and a 14 month follow-up did not show recurrence in any patient. These results suggest that azithromycin can be a good therapeutic option for the treatment of cutaneous leishmaniasis caused by Leishmania Viannia brasiliensis.
Resumo:
Forty voluntary blood donors from two different blood banks in Havana, Cuba, who were repeatedly reactive on the routine screening of antibodies to hepatitis C virus, by Umelisa HCV test, were analyzed for the presence of HCV RNA using a nested PCR assay of the HCV 5' untranslated region, Umelosa HCV qualitative. Sera from 45 patients of a specialized gastroenterology consultation, positive to Umelisa HCV, were also assayed with the Umelosa HCV qualitative, to establish their condition related to the presence of HCV RNA previously to the indication of a treatment or after three, six or twelve months of antiviral therapy. Serum HCV-RNA was detected in 21/40 (52.5%) donors who had repeatedly positive ELISA results, confirming the HCV infection for them. In specialized consultation HCV-RNA was detected by PCR analysis in 30/45 (66%) analyzed sera.
Resumo:
Multiple exposures to parasitic agents are considered an important factor in the genesis of the most severe forms of the diseases they cause. Capillaria hepatica-induced septal fibrosis of the liver in rats usually runs without signs of portal hypertension or hepatic failure. After determining the hepatic profile of 15 animals during the course of a single infection, we submitted 20 rats to multiple Capillaria hepatica infections to determine whether repeated exposures would augment fibrosis production, transforming septal hepatic fibrosis into a true cirrhosis. Ten single-infection rats served as controls. A total of 5 exposures, with 45-day intervals, were made. Histological changes were followed by means of surgical liver biopsies, collected prior to infection and to each re-infection. Functional changes were minimal and transient. Although a slight recrudescence of fibrosis was observed after the first two re-infections and when the single-infected control group was re-infected at the end of the experiment, subsequent re-infections failed to increase the amount of fibrosis. On the contrary, there occurred quantitative and qualitative evidence of collagen degradation and suppression of parasite development. These paradoxical results are in keeping with the hypothesis that a complex immunological modulation participates in the mechanism of hepatic fibrosis induced by Capillaria hepatica infection in rats.
Resumo:
The purpose of this work was to test a cytomegalovirus qualitative PCR and a semi-quantitative PCR on the determination of CMV load in leukocytes of bone marrow and kidney transplanted (RT) patients. Thirty three BMT and 35 RT patients participated of the study. The DNA was subjected to a qualitative PCR using primers that amplify part of CMV gB gene. CMV load of positive samples was determined by a semi-quantitative PCR using quantified plasmids inserted with part of the gB gene of CMV as controls. The sensitivity of the test was determined to be 867 plasmid copies/µg DNA. CMV loads between 2,118 and 72,443 copies/µg DNA were observed in 12.1% BMT recipients and between 1,246 and 58,613 copies/µg DNA in 22.9% RT recipients. Further studies are necessary to confirm the usefulness of this CMV semi-quantitative PCR in transplanted patients.
Resumo:
A ligase chain reaction DNA amplification method for direct detection of Mycobacterium tuberculosis (Abbott LCx MTB) in respiratory specimens was evaluated. Results from LCx MTB Assay were compared with those from acid fast bacilli smear, culture, and final clinical diagnosis for each patient. A total of 297 respiratory specimens (sputum and bronchial lavage) from 193 patients were tested. The sensitivity, specificity, positive predictive value and negative predictive value of LCx vs culture were 92.7%, 93%, 67.8% and 98.7%, respectively. When compared to the clinical final diagnosis, the sensitivity, specificity, PPV and NPV for LCx were 88.9%, 96.8%, 86.5% and 97.4%, respectively. The sensitivity of LCx MTB assay was 75% for smear-negative, culture positive samples. The results indicate that LCx MTB assay is a rapid, simple and valuable technique as a complementary tool for the diagnosis of tuberculosis.
Resumo:
This study aimed to evaluate the second-generation OptiMal test for malaria diagnosis under various storage conditions. It detected all the positive samples, except for two Plasmodium malariae samples. Further research evaluating diverse environmental conditions are important for ICT test applicability in Brazilian malaria areas.
Resumo:
Mycobaterium leprae infection was investigated in armadillos from the State of Espírito Santo, Brazil. The ML Flow test was performed on 37 nine-banded armadillos and positive results were found in 11 (29.7%). The ML Flow test may be used to identify possible sources of Mycobaterium leprae among wild armadillos.
Resumo:
The work presented in this thesis was developed in collaboration with a Portuguese company, BeyonDevices, devoted to pharmaceutical packaging, medical technology and device industry. Specifically, the composition impact and surface modification of two polymeric medical devices from the company were studied: inhalers and vaginal applicators. The polyethylene-based vaginal applicator was modified using supercritical fluid technology to acquire self-cleaning properties and prevent the transport of bacteria and yeasts to vaginal flora. For that, in-situ polymerization of 2-substituted oxazolines was performed within the polyethylene matrix using supercritical carbon dioxide. The cationic ring-opening polymerization process was followed by end-capping with N,N-dimethyldodecylamine. Furthermore, for the same propose, the polyethylene matrix was impregnated with lavender oil in supercritical medium. The obtained materials were characterized physical and morphologically and the antimicrobial activity against bacteria and yeasts was accessed. Materials modified using 2-substituted oxazolines showed an effective killing ability for all the tested microorganisms, while the materials modified with lavender oil did not show antimicrobial activity. Only materials modified with oligo(2-ethyl-2-oxazoline) maintain the activity during the long term stability. Furthermore, the cytotoxicity of the materials was tested, confirming their biocompatibilty. Regarding the inhaler, its surface was modified in order to improve powder flowability and consequently, to reduce powder retention in the inhaler´s nozzle. New dry powder inhalers (DPIs), with different needle’s diameters, were evaluated in terms of internal resistance and uniformity of the emitted dose. It was observed that they present a mean resistance of 0.06 cmH2O0.5/(L/min) and the maximum emitted dose obtained was 68.9% for the inhaler with higher needle´s diameter (2 mm). Thus, this inhaler was used as a test and modified by the coating with a commonly-used force control agent, magnesium stearate, dried with supercritical carbon dioxide (scCO2) and the uniformity of delivered dose tests were repeated. The modified inhaler showed an increase in emitted dose from 68.9% to 71.3% for lactose and from 30.0% to 33.7% for Foradil.
Resumo:
To assess the performance of the immunochromatographic test for filariasis, adult Wuchereria bancrofti worms were incubated under different conditions. The tests were strongly positive with incubation fluids from both living and mechanically damaged females. Negative results were observed with incubation fluids from all male worms and from intact dead females.
Resumo:
Latent tuberculosis was studied in a research laboratory. A prevalence of positive tuberculin skin test results (> 15mm) of 20% was found and the main predictors were place of birth in a foreign country with high prevalence of tuberculosis and a history of contact with patients with untreated active tuberculosis.
Resumo:
It is important to have better evaluation and understanding of the motor neuron physiology, with the goal to early and objectively diagnose and treat patients with neurodegenerative pathologies. The Compound Muscle Action Potential (CMAP) scan is a non-invasive diagnosis technique for neurodegenerative pathologies, such as ALS, and enables a quick analysis of the muscle action potentials in response to motor nerve stimulation. This work aims to study the influence of different pulse modulated waveforms in peripheral nerve excitability by CMAP scan technique on healthy subjects. A total of 13 healthy subjects were submitted to the same test. The stimuli were applied in the medium nerve on the right wrist and electromyography signal collected on the Abductor Pollicis Brevis (APB) muscle surface on the right thumb. Stimulation was performed with an increasing intensities range from 4 to 30 mA, with varying steps, 3 stimuli per step. The procedure was repeated 4 times per subject, each repetition using a different single pulse stimulation waveform: monophasic square, monophasic triangular, monophasic quadratic and biphasic square. Results were retrieved from the averaging of the stimuli on each current intensity step. The square pulse needs less current intensity to generate the same response amplitude regarding the other waves and presents a more steep curve slope and this effect is gradually decreasing for the triangular and quadratic pulse,respectively, being the difference even more evident regarding the biphasic pulse. The control of the waveform stimulation pulse allows varying the stimulusresponse curve slope.
Resumo:
INTRODUCTION: HTLV-1/2 screening among blood donors commonly utilizes an enzyme-linked immunosorbent assay (EIA), followed by a confirmatory method such as Western blot (WB) if the EIA is positive. However, this algorithm yields a high rate of inconclusive results, and is expensive. METHODS: Two qualitative real-time PCR assays were developed to detect HTLV-1 and 2, and a total of 318 samples were tested (152 blood donors, 108 asymptomatic carriers, 26 HAM/TSP patients and 30 seronegative individuals). RESULTS: The sensitivity and specificity of PCR in comparison with WB results were 99.4% and 98.5%, respectively. PCR tests were more efficient for identifying the virus type, detecting HTLV-2 infection and defining inconclusive cases. CONCLUSIONS: Because real-time PCR is sensitive and practical and costs much less than WB, this technique can be used as a confirmatory test for HTLV in blood banks, as a replacement for WB.
Resumo:
Fundação para a Ciência e a Tecnologia (FCT) - PhD grant (SFRH/BD/62568/2009)
Resumo:
INTRODUCTION: Arenavirus hemorrhagic fever is a severe emerging disease. METHODS: Considering that the levels of antibodies against arenavirus in the Brazilian population are completely unknown, we have standardized an ELISA test for detecting IgG antibodies using a recombinant nucleoprotein from the Junin virus as the antigen. This protein was obtained by inserting the gene of the Junin virus nucleoprotein into the genome of Autographa californica nucleopolyhedrovirus, using the Bac-to-Bac baculovirus expression system. This recombinant baculovirus was used to infect S. frugiperda cells (SF9). RESULTS: The infection resulted in synthesis of high concentrations of recombinant protein. This protein was detected on 12.5% polyacrylamide gel and by means of Western blot. Using the standardized ELISA test, 343 samples from the population of Nova Xavantina were analyzed. We observed that 1.4% of the serum samples (five samples) presented antibody titers against arenavirus. CONCLUSIONS: These results show the population studied may present exposure to arenavirus infection.