992 resultados para Quantitative oogram technique


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Superior vena cava (SVC) clamping can be required during thoracic surgery for SVC replacement or repair. In such cases, bypass techniques can be necessary to avoid hemodynamic instability, cerebral venous hypertension and hypoperfusion. Here, we report a novel and simple SVC bypass technique which does not require full systemic heparinization, specialized cannulation techniques or pumping devices and which can be applied percutaneously in the preoperative phase or intraoperatively. The preoperative shunt consisted in two Swan-Ganz catheters inserted in the jugular and femoral veins and connected by perfusion tubing with a three way stopcock. The intraoperative shunt consisted of a Pruitt(®)-catheter inserted in the left innominate vein and connected to a femoral Swan-Ganz catheter by perfusion tubing. We validated our system in seven patients undergoing SVC reconstruction. We monitored the systemic arterial blood pressures, the heart rate and vasoactive peptide requirements throughout the procedure. We also determined the neurological status and the in-hospital morbidity and mortality for each patient. Using this bypass, SVC clamping caused no hemodynamic instability, no neurological impairments and no in-hospital complications or deaths. This simple temporary SVC bypass procedure is safe and avoids hemodynamic instability and cerebral venous hypertension.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To develop and compare two new technologies for diagnosing a contiguous gene syndrome, the Williams-Beuren syndrome (WBS). METHODS: The first proposed method, named paralogous sequence quantification (PSQ), is based on the use of paralogous sequences located on different chromosomes and quantification of specific mismatches present at these loci using pyrosequencing technology. The second exploits quantitative real time polymerase chain reaction (QPCR) to assess the relative quantity of an analysed locus. RESULTS: A correct and unambiguous diagnosis was obtained for 100% of the analysed samples with either technique (n = 165 and n = 155, respectively). These methods allowed the identification of two patients with atypical deletions in a cohort of 182 WBS patients. Both patients presented with mild facial anomalies, mild mental retardation with impaired visuospatial cognition, supravalvar aortic stenosis, and normal growth indices. These observations are consistent with the involvement of GTF2IRD1 or GTF2I in some of the WBS facial features. CONCLUSIONS: Both PSQ and QPCR are robust, easy to interpret, and simple to set up. They represent a competitive alternative for the diagnosis of segmental aneuploidies in clinical laboratories. They have advantages over fluorescence in situ hybridisation or microsatellites/SNP genotyping for detecting short segmental aneuploidies as the former is costly and labour intensive while the latter depends on the informativeness of the polymorphisms.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To derive a prediction rule by using prospectively obtained clinical and bone ultrasonographic (US) data to identify elderly women at risk for osteoporotic fractures. MATERIALS AND METHODS: The study was approved by the Swiss Ethics Committee. A prediction rule was computed by using data from a 3-year prospective multicenter study to assess the predictive value of heel-bone quantitative US in 6174 Swiss women aged 70-85 years. A quantitative US device to calculate the stiffness index at the heel was used. Baseline characteristics, known risk factors for osteoporosis and fall, and the quantitative US stiffness index were used to elaborate a predictive rule for osteoporotic fracture. Predictive values were determined by using a univariate Cox model and were adjusted with multivariate analysis. RESULTS: There were five risk factors for the incidence of osteoporotic fracture: older age (>75 years) (P < .001), low heel quantitative US stiffness index (<78%) (P < .001), history of fracture (P = .001), recent fall (P = .001), and a failed chair test (P = .029). The score points assigned to these risk factors were as follows: age, 2 (3 if age > 80 years); low quantitative US stiffness index, 5 (7.5 if stiffness index < 60%); history of fracture, 1; recent fall, 1.5; and failed chair test, 1. The cutoff value to obtain a high sensitivity (90%) was 4.5. With this cutoff, 1464 women were at lower risk (score, <4.5) and 4710 were at higher risk (score, >or=4.5) for fracture. Among the higher-risk women, 6.1% had an osteoporotic fracture, versus 1.8% of women at lower risk. Among the women who had a hip fracture, 90% were in the higher-risk group. CONCLUSION: A prediction rule obtained by using quantitative US stiffness index and four clinical risk factors helped discriminate, with high sensitivity, women at higher versus those at lower risk for osteoporotic fracture.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Previous studies of the visual outcome in bilateral non-arteritic anterior ischemic optic neuropathy (NAION) have yielded conflicting results, specifically regarding congruity between fellow eyes. Prior studies have used measures of acuity and computerized perimetry but none has compared Goldmann visual field outcomes between fellow eyes. In order to better define the concordance of visual loss in this condition, we reviewed our cases of bilateral sequential NAION, including measures of visual acuity, pupillary function and both pattern and severity of visual field loss.Methods: We performed a retrospective chart review of 102 patients with a diagnosis of bilateral sequential NAION. Of the 102 patients, 86 were included in the study for analysis of final visual outcome between the affected eyes. Visual function was assessed using visual acuity, Goldmann visual fields, color vision and RAPD. A quantitative total visual field score and score per quadrant was analyzed for each eye using the numerical Goldmann visual field scoring method previously described by Esterman and colleagues. Based upon these scores, we calculated the total deviation and pattern deviation between fellow eyes and between eyes of different patients. Statistical significance was determined using nonparametric tests.Results: A statistically significant correlation was found between fellow eyes for multiple parameters, including logMAR visual acuity (P = 0.0101), global visual field (P = 0.0001), superior visual field (P = 0.0001), and inferior visual field (P = 0.0001). In addition, the mean deviation of both total (P = 0.0000000007) and pattern (P = 0.000000004) deviation analyses was significantly less between fellow eyes ("intra"-eyes) than between eyes of different patients ("inter"-eyes).Conclusions: Visual function between fellow eyes showed a fair to moderate correlation that was statistically significant. The pattern of vision loss was also more similar in fellow eyes than between eyes of different patients. These results may help allow better prediction of visual outcome for the second eye in patients with NAION. These findings may also be useful for evaluating efficacy of therapeutic interventions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose To investigate the differences in viscoelastic properties between normal and pathologic Achilles tendons ( AT Achilles tendon s) by using real-time shear-wave elastography ( SWE shear-wave elastography ). Materials and Methods The institutional review board approved this study, and written informed consent was obtained from 25 symptomatic patients and 80 volunteers. One hundred eighty ultrasonographic (US) and SWE shear-wave elastography studies of AT Achilles tendon s without tendonopathy and 30 studies of the middle portion of the AT Achilles tendon in patients with tendonopathy were assessed prospectively. Each study included data sets acquired at B-mode US (tendon morphology and cross-sectional area) and SWE shear-wave elastography (axial and sagittal mean velocity and relative anisotropic coefficient) for two passively mobilized ankle positions. The presence of AT Achilles tendon tears at B-mode US and signal-void areas at SWE shear-wave elastography were noted. Results Significantly lower mean velocity was shown in tendons with tendonopathy than in normal tendons in the relaxed position at axial SWE shear-wave elastography (P < .001) and in the stretched position at sagittal (P < .001) and axial (P = .0026) SWE shear-wave elastography . Tendon softening was a sign of tendonopathy in relaxed AT Achilles tendon s when the mean velocity was less than or equal to 4.06 m · sec(-1) at axial SWE shear-wave elastography (sensitivity, 54.2%; 95% confidence interval [ CI confidence interval ]: 32.8, 74.4; specificity, 91.5%; 95% CI confidence interval : 86.3, 95.1) and less than or equal to 5.70 m · sec(-1) at sagittal SWE shear-wave elastography (sensitivity, 41.7%; 95% CI confidence interval : 22.1, 63.3; specificity, 81.8%; 95% CI confidence interval : 75.3, 87.2) and in stretched AT Achilles tendon s, when the mean velocity was less than or equal to 4.86 m · sec(-1) at axial SWE shear-wave elastography (sensitivity, 66.7%; 95% CI confidence interval : 44.7, 84.3; specificity, 75.6%; 95% CI confidence interval : 68.5, 81.7) and less than or equal to 14.58 m · sec(-1) at sagittal SWE shear-wave elastography (sensitivity, 58.3%; 95% CI confidence interval : 36.7, 77.9; specificity, 83.5%; 95% CI confidence interval : 77.2, 88.7). Anisotropic results were not significantly different between normal and pathologic AT Achilles tendon s. Six of six (100%) partial-thickness tears appeared as signal-void areas at SWE shear-wave elastography . Conclusion Whether the AT Achilles tendon was relaxed or stretched, SWE shear-wave elastography helped to confirm and quantify pathologic tendon softening in patients with tendonopathy in the midportion of the AT Achilles tendon and did not reveal modifications of viscoelastic anisotropy in the tendon. Tendon softening assessed by using SWE shear-wave elastography appeared to be highly specific, but sensitivity was relatively low. © RSNA, 2014.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this study was to assess the applicability of posterior wall repair with a synthetic absorbable mesh. Between January and September 1996, five posterior repairs using absorbable synthetic meshes were performed. Five posterior wall repairs in patients matched for age, parity, and rectocele degree were performed according to usual procedures during the same period, and were used as controls. No febrile morbidity, cuff or posterior vaginal wall infections, thrombophlebitis, rectal injury, or hemorrhagic complications were observed in the 10 women who entered the study. In summary, posterior wall repair can be easily performed with an absorbable soft tissue patch, theoretically preserving sexual activity, and probably offers better functional results with longer experience, thus providing a safe and useful procedure in sexually active women.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Quantitative knowledge of the turnover of different leukocyte populations is a key to our understanding of immune function in health and disease. Much progress has been made thanks to the introduction of stable isotope labeling, the state-of-the-art technique for in vivo quantification of cellular life spans. Yet, even leukocyte life span estimates on the basis of stable isotope labeling can vary up to 10-fold among laboratories. We investigated whether these differences could be the result of variances in the length of the labeling period among studies. To this end, we performed deuterated water-labeling experiments in mice, in which only the length of label administration was varied. The resulting life span estimates were indeed dependent on the length of the labeling period when the data were analyzed using a commonly used single-exponential model. We show that multiexponential models provide the necessary tool to obtain life span estimates that are independent of the length of the labeling period. Use of a multiexponential model enabled us to reduce the gap between human T-cell life span estimates from 2 previously published labeling studies. This provides an important step toward unambiguous understanding of leukocyte turnover in health and disease.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A Knudsen flow reactor has been used to quantify surface functional groups on aerosols collected in the field. This technique is based on a heterogeneous titration reaction between a probe gas and a specific functional group on the particle surface. In the first part of this work, the reactivity of different probe gases on laboratory-generated aerosols (limonene SOA, Pb(NO3)2, Cd(NO3)2) and diesel reference soot (SRM 2975) has been studied. Five probe gases have been selected for the quantitative determination of important functional groups: N(CH3)3 (for the titration of acidic sites), NH2OH (for carbonyl functions), CF3COOH and HCl (for basic sites of different strength), and O3 (for oxidizable groups). The second part describes a field campaign that has been undertaken in several bus depots in Switzerland, where ambient fine and ultrafine particles were collected on suitable filters and quantitatively investigated using the Knudsen flow reactor. Results point to important differences in the surface reactivity of ambient particles, depending on the sampling site and season. The particle surface appears to be multi-functional, with the simultaneous presence of antagonistic functional groups which do not undergo internal chemical reactions, such as acid-base neutralization. Results also indicate that the surface of ambient particles was characterized by a high density of carbonyl functions (reactivity towards NH2OH probe in the range 0.26-6 formal molecular monolayers) and a low density of acidic sites (reactivity towards N(CH3)3 probe in the range 0.01-0.20 formal molecular monolayer). Kinetic parameters point to fast redox reactions (uptake coefficient ?0>10-3 for O3 probe) and slow acid-base reactions (?0<10-4 for N(CH3)3 probe) on the particle surface. [Authors]

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Any transportation infrastructure system is inherently concerned with durability and performance issues. The proportioning and uniformity control of concrete mixtures are critical factors that directly affect the longevity and performance of the portland cement concrete pavement systems. At present, the only means available to monitor mix proportions of any given batch are to track batch tickets created at the batch plant. However, this does not take into account potential errors in loading materials into storage silos, calibration errors, and addition of water after dispatch. Therefore, there is a need for a rapid, cost-effective, and reliable field test that estimates the proportions of as-delivered concrete mixtures. In addition, performance based specifications will be more easily implemented if there is a way to readily demonstrate whether any given batch is similar to the proportions already accepted based on laboratory performance testing. The goal of the present research project is to investigate the potential use of a portable x-ray fluorescence (XRF) technique to assess the proportions of concrete mixtures as they are delivered. Tests were conducted on the raw materials, paste and mortar samples using a portable XRF device. There is a reasonable correlation between the actual and calculated mix proportions of the paste samples, but data on mortar samples was less reliable.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: The purpose of this article is to assess the effect of the adaptive statistical iterative reconstruction (ASIR) technique on image quality in hip MDCT arthrography and to evaluate its potential for reducing radiation dose. SUBJECTS AND METHODS: Thirty-seven patients examined with hip MDCT arthrography were prospectively randomized into three different protocols: one with a regular dose (volume CT dose index [CTDIvol], 38.4 mGy) and two with a reduced dose (CTDIvol, 24.6 or 15.4 mGy). Images were reconstructed using filtered back projection (FBP) and four increasing percentages of ASIR (30%, 50%, 70%, and 90%). Image noise and contrast-to-noise ratio (CNR) were measured. Two musculoskeletal radiologists independently evaluated several anatomic structures and image quality parameters using a 4-point scale. They also jointly assessed acetabular labrum tears and articular cartilage lesions. RESULTS: With decreasing radiation dose level, image noise statistically significantly increased (p=0.0009) and CNR statistically significantly decreased (p=0.001). We also found a statistically significant reduction in noise (p=0.0001) and increase in CNR (p≤0.003) with increasing percentage of ASIR; in addition, we noted statistically significant increases in image quality scores for the labrum and cartilage, subchondral bone, overall diagnostic quality (up to 50% ASIR), and subjective noise (p≤0.04), and statistically significant reductions for the trabecular bone and muscles (p≤0.03). Regardless of the radiation dose level, there were no statistically significant differences in the detection and characterization of labral tears (n=24; p=1) and cartilage lesions (n=40; p≥0.89) depending on the ASIR percentage. CONCLUSION: The use of up to 50% ASIR in hip MDCT arthrography helps to reduce radiation dose by approximately 35-60%, while maintaining diagnostic image quality comparable to that of a regular-dose protocol using FBP.