951 resultados para PET CATS
Resumo:
We wish to acknowledge the support of the Brazilian agencies: CNPq, CAPES, and FAPESP (2015/07311-7 and 2011/19296-1).
Resumo:
Purpose: We have reported that the changes in the pupillary shape in response to electrical stimulation of the branches of the ciliary nerves in cats. (Miyagawa et al. PLoS One, 2014). This study investigates the changes in the pupillary shapes in response to electrical stimulations of the sclera of peripheral cornea in cats and porcines. Methods: Two enucleated eyes of two cats and three enucleated porcine eyes were studied. Trains of biphasic pulses (current, 3 mA; duration, 2 ms/phase; frequency, 40 Hz) were applied using a tungsten electrode (0.3mm diameter). The stimulation was performed at every 45 degree over the entire circular region on the sclera near the cornea. The pupillary images were recorded before and 4 s (cat) and 10 s (pig) after the stimulation and the change in the pupil diameter (Δr) was quantified. The pupillary images were obtained with a custom-built compact wavefront aberrometer (Uday et al. J Cataract Refract Surg, 2013). Results: In a cat eye, the pupil was dilated by the electrical stimulation at six out of eight orientations (before stimulation pupil diameter r=10.10±0.49 mm, Δr=0.33±0.12 mm). The pupil dilated only toward the electrode (relative eccentricity of the pupil center to the pupil diameter change amount rdec=1.15±0.28). In the porcine eyes, the pupils were constricted by the electrical stimulations at the temporal and nasal orientations (r=10.04±0.57 mm, Δr=1.52±0.70 mm). The pupils contracted symmetrically (rdec=0.30±0.12). Conclusions: With electrical stimulation in the sclera of the peripheral cornea, asymmetric mydriasis in cat eyes and symmetrical miosis in porcine eyes were observed. Under the assumption that the electrical stimulation stimulated both muscles that contribute to the pupil control, our hypothesis proposed here is that the pupil dilator is stronger than the pupil sphincter in cat, and pupil sphincter is stronger than pupil dilator in porcine.
Resumo:
Purpose: We have reported that the changes in the accommodative response to electrical stimulation of the branches of the ciliary nerves in cats. (Miyagawa et al, PLoS One, 2014). We have also reported that no robust accommodative responses to the electrical stimulations of the sclera of peripheral cornea (SSPC) were observed in enucleated porcine eyes (Mihashi et al, VPOptics, 2014). In this study, accommodative responses to SSPC stimulation in cats and porcines were investigated. Methods: Two eyes of two cats under anesthesia and after they were sacrificed were studied. Three enucleated porcine eyes obtained from a local slaughterhouse were also studied. Trains of biphasic pulses (current, 3 mA; duration, 2 ms/phase; frequency, 40 Hz) were applied using a tungsten electrode (0.3mm diameter) from several orientations. Wavefront sensing with a compact wavefront aberrometer (Uday et al J Cataract Refract Surg, 2013) were performed before and 4 s (cat) and 10 s (pig) after the stimulations and wavefront aberrations including spherical errors were analyzed over a 4-mm pupil area. Results: In the first cat under anesthesia, at three out of seven stimulus positions, 0.2 D hyperopic accommodative responses were observed and in two orientations, myopic responses were observed. For the other cat, weak accommodative responses including astigmatic changes were observed. In the sacrificed condition of the second cat, 0.1 D myopic response was observed for one stimulus orientation and the smaller responses were observed at six out of eight stimulus positions. No accommodative responses were elicited for the enucleated porcine eyes. Conclusions: In the anesthetized cats, electrical stimulation of the SSPC induced accommodative responses; the responses were unstable and weaker than the responses by the ciliary nerve stimulations we observed in our previous study. Small accommodative responses were observed after one of two cats had been sacrificed, but no accommodative responses were detected in the enucleated porcine eyes. Further studies are needed to confirm difference in the accommodation functions in the two species.
Resumo:
Colorectal cancer is the third most commonly diagnosed cancer, accounting for 53,219 deaths in 2007 and an estimated 146,970 new cases in the USA during 2009. The combination of FDG PET and CT has proven to be of great benefit for the assessment of colorectal cancer. This is most evident in the detection of occult metastases, particularly intra- or extrahepatic sites of disease, that would preclude a curative procedure or in the detection of local recurrence. FDG PET is generally not used for the diagnosis of colorectal cancer although there are circumstances where PET-CT may make the initial diagnosis, particularly with its more widespread use. In addition, precancerous adenomatous polyps can also be detected incidentally on whole-body images performed for other indications; sensitivity increases with increasing polyp size. False-negative FDG PET findings have been reported with mucinous adenocarcinoma, and false-positive findings have been reported due to inflammatory conditions such as diverticulitis, colitis, and postoperative scarring. Therefore, detailed evaluation of the CT component of a PET/CT exam, including assessment of the entire colon, is essential.
Resumo:
Head motion during a Positron Emission Tomography (PET) brain scan can considerably degrade image quality. External motion-tracking devices have proven successful in minimizing this effect, but the associated time, maintenance, and workflow changes inhibit their widespread clinical use. List-mode PET acquisition allows for the retroactive analysis of coincidence events on any time scale throughout a scan, and therefore potentially offers a data-driven motion detection and characterization technique. An algorithm was developed to parse list-mode data, divide the full acquisition into short scan intervals, and calculate the line-of-response (LOR) midpoint average for each interval. These LOR midpoint averages, known as “radioactivity centroids,” were presumed to represent the center of the radioactivity distribution in the scanner, and it was thought that changes in this metric over time would correspond to intra-scan motion.
Several scans were taken of the 3D Hoffman brain phantom on a GE Discovery IQ PET/CT scanner to test the ability of the radioactivity to indicate intra-scan motion. Each scan incrementally surveyed motion in a different degree of freedom (2 translational and 2 rotational). The radioactivity centroids calculated from these scans correlated linearly to phantom positions/orientations. Centroid measurements over 1-second intervals performed on scans with ~1mCi of activity in the center of the field of view had standard deviations of 0.026 cm in the x- and y-dimensions and 0.020 cm in the z-dimension, which demonstrates high precision and repeatability in this metric. Radioactivity centroids are thus shown to successfully represent discrete motions on the submillimeter scale. It is also shown that while the radioactivity centroid can precisely indicate the amount of motion during an acquisition, it fails to distinguish what type of motion occurred.
Resumo:
Dynamic positron emission tomography (PET) imaging can be used to track the distribution of injected radio-labelled molecules over time in vivo. This is a powerful technique, which provides researchers and clinicians the opportunity to study the status of healthy and pathological tissue by examining how it processes substances of interest. Widely used tracers include 18F-uorodeoxyglucose, an analog of glucose, which is used as the radiotracer in over ninety percent of PET scans. This radiotracer provides a way of quantifying the distribution of glucose utilisation in vivo. The interpretation of PET time-course data is complicated because the measured signal is a combination of vascular delivery and tissue retention effects. If the arterial time-course is known, the tissue time-course can typically be expressed in terms of a linear convolution between the arterial time-course and the tissue residue function. As the residue represents the amount of tracer remaining in the tissue, this can be thought of as a survival function; these functions been examined in great detail by the statistics community. Kinetic analysis of PET data is concerned with estimation of the residue and associated functionals such as ow, ux and volume of distribution. This thesis presents a Markov chain formulation of blood tissue exchange and explores how this relates to established compartmental forms. A nonparametric approach to the estimation of the residue is examined and the improvement in this model relative to compartmental model is evaluated using simulations and cross-validation techniques. The reference distribution of the test statistics, generated in comparing the models, is also studied. We explore these models further with simulated studies and an FDG-PET dataset from subjects with gliomas, which has previously been analysed with compartmental modelling. We also consider the performance of a recently proposed mixture modelling technique in this study.
Resumo:
BACKGROUND AND PURPOSE: To assess the impact of a standardized delineation protocol and training interventions on PET/CT-based target volume delineation (TVD) in NSCLC in a multicenter setting.
MATERIAL AND METHODS: Over a one-year period, 11 pairs, comprised each of a radiation oncologist and nuclear medicine physician with limited experience in PET/CT-based TVD for NSCLC from nine different countries took part in a training program through an International Atomic Energy Agency (IAEA) study (NCT02247713). Teams delineated gross tumor volume of the primary tumor, during and after training interventions, according to a provided delineation protocol. In-house developed software recorded the performed delineations, to allow visual inspection of strategies and to assess delineation accuracy.
RESULTS: Following the first training, overall concordance indices for 3 repetitive cases increased from 0.57±0.07 to 0.66±0.07. The overall mean surface distance between observer and expert contours decreased from -0.40±0.03 cm to -0.01±0.33 cm. After further training overall concordance indices for another 3 repetitive cases further increased from 0.64±0.06 to 0.80±0.05 (p=0.01). Mean surface distances decreased from -0.34±0.16 cm to -0.05±0.20 cm (p=0.01).
CONCLUSION: Multiple training interventions improve PET/CT-based TVD delineation accuracy in NSCLC and reduces interobserver variation.
Resumo:
La PET/RMN è un ibrido delle tecnologie di imaging che incorpora la risonanza magnetica nucleare (RMN), che fornisce un'imaging di tipo morfologico, e la tomografia ad emissione di positroni (PET), che fornisce un'imaging di tipo funzionale. Questa nuova tecnologia trova applicazioni in campo oncologico, cardiovascolare e nello studio del sistema nervoso centrale (SNC). La realizzazione di questa nuova tecnologia ha comportato diverse sfide tecniche per la combinazione delle due apparecchiature, che sono state risolte con diversi approcci. Lo sviluppo futuro della PET/RMN sarà guidato da molteplici fattori tra i quali l'eliminazione degli eventuali disturbi e la necessità di accordi per i rimborsi dell'esame. Tutt'ora esistono tre diversi produttori al mondo : Simens, Philips e GE (General Electric), i quali hanno diverse tecnologie e diversi metodi di analisi. La prima apparecchiatura PET/RMN in Italia è stata acquistata dall'ospedale di Padova nel gennaio 2015, mentre negli altri paesi aveva già fatto la sua comparsa dal 2011.
Resumo:
Nell'ambito della Diagnostica per Immagini, l'imaging ibrido sta assumendo un ruolo fondamentale in molte applicazioni cliniche, tra cui oncologia, neurologia e cardiologia. La possibilità di integrare informazioni complementari, funzionali e morfologiche, in un'unica immagine, permette di valutare con estrema accuratezza varie tipologie di malattie, diminuendo i tempi di acquisizione e i disagi per i pazienti. La risonanza magnetica, in sostituzione alla TAC nel sistema integrato PET/TC, introduce notevoli vantaggi quali l'acquisizione simultanea dei dati, l'ottimo contrasto dei tessuti molli, l'assenza di radiazioni ionizzanti e la correzione degli artefatti da movimento; ciò migliora l'accuratezza delle immagini e, di conseguenza, il processo diagnostico. Nonostante sia un interessante strumento di diagnostica e l'apice dello sviluppo tecnologico in imaging nucleare, vi sono alcune problematiche che ne impediscono la diffusa adozione, tra cui le interferenze reciproche tra le due modalità, i costi elevati e ancora una ridotta pubblicazione di articoli al riguardo.
Resumo:
[ES]Este proyecto trata de desarrollar una aplicación web en Ruby on Rails, donde el usuario pueda visualizar en “tiempo real” la ubicación de su animal haciendo uso de su identificador con GPS (microchip con GPS), si existiera tal dispositivo, o un dispositivo de geolocalización GPS incrustado en el collar del perro, para hacer un seguimiento del mismo cuando otra persona que ha sido contratada lo pasea. Al no disponer de microchips o collares con GPS, así como los respectivos animales para hacer el estudio y, por tanto, su posterior seguimiento, se realizará una simulación del mismo, de ahí que el tiempo real esté puesto entre comillas.
Resumo:
Thesis (Ph.D.)--University of Washington, 2016-08
Resumo:
La maladie d’Alzheimer (MA) se caractérise pathologiquement par l’accumulation de plaques amyloïde dans le cerveau. La tomographie par émission de positrons (TEP) permet d’imager les plaques amyloïde in vivo. Le but de ce projet est d’évaluer le rôle de la TEP amyloïde dans le processus diagnostique de la MA dans des cas de démences atypiques. Le deuxième but de ce projet est de déterminer l’impact de la révélation d’un diagnostic plus certain chez les proches aidants. 28 patients sans diagnostic malgré une investigation exhaustive ont été sélectionnées et imagées avec le traceur amyloïde 18F-NAV4694 (âge 59,3 ans, é-t. 5,8; MMSE 21.4, é-t 6.0). Les neurologues référents documentaient par la suite tout changement de niveau de certitude, de diagnostic, de traitement et/ou de prise en charge. Les proches aidants consentants ont été rencontrés subséquemment, et un questionnaire avec une échelle de Likert a été utilisé afin de documenter l’impact de l’imagerie leur perception de la maladie. Notre cohorte a été également divisée entre amyloïde positifs (14/28) et négatifs (14/28). Un changement de diagnostic a lieu dans 9/28 cas (32,1% :17.8% ont changé de MA à non-MA, 14,3% de non-MA à MA). Il y avait une augmentation significative (p<0,05) de 44% dans la certitude du neurologue suite à cet examen. Un changement de prise en charge a été obtenu dans 20/28 (71,4%) des cas. Bien que non significatifs statistiquement, un impact favorable sur les proches-aidants a été noté. Cette étude suggère que l’imagerie amyloïde a un rôle bénéfique dans les cas de démences atypiques n’ayant pu être élucidés avec les techniques d’investigations actuellement recommandées. De plus, le processus a été perçu positivement par les proches aidants, notamment en encourageant du temps de qualité avec leurs personnes chères. Ceci illustre un rôle prometteur des biomarqueurs, qui sont de plus en plus explorés.
Resumo:
BACKGROUND: Several analysis software packages for myocardial blood flow (MBF) quantification from cardiac PET studies exist, but they have not been compared using concordance analysis, which can characterize precision and bias separately. Reproducible measurements are needed for quantification to fully develop its clinical potential. METHODS: Fifty-one patients underwent dynamic Rb-82 PET at rest and during adenosine stress. Data were processed with PMOD and FlowQuant (Lortie model). MBF and myocardial flow reserve (MFR) polar maps were quantified and analyzed using a 17-segment model. Comparisons used Pearson's correlation ρ (measuring precision), Bland and Altman limit-of-agreement and Lin's concordance correlation ρc = ρ·C b (C b measuring systematic bias). RESULTS: Lin's concordance and Pearson's correlation values were very similar, suggesting no systematic bias between software packages with an excellent precision ρ for MBF (ρ = 0.97, ρc = 0.96, C b = 0.99) and good precision for MFR (ρ = 0.83, ρc = 0.76, C b = 0.92). On a per-segment basis, no mean bias was observed on Bland-Altman plots, although PMOD provided slightly higher values than FlowQuant at higher MBF and MFR values (P < .0001). CONCLUSIONS: Concordance between software packages was excellent for MBF and MFR, despite higher values by PMOD at higher MBF values. Both software packages can be used interchangeably for quantification in daily practice of Rb-82 cardiac PET.
Resumo:
The purpose of this study was to investigate the subjective perception of anxiety pre- and post-procedure, and explore the relationship between demographic, clinical variables and cancer patients' anxiety during a positron emission tomography/computed tomography (PET/CT) scan. Two hundred and thirty-two oncological out patients, with clinical indication for performing an (18)F-2-fluoro-2-deoxy-D-glucose ((18)F-FDG) PET/CT scan and attending a nuclear medicine (NM) department, participated in the study. Patients' anxiety and subjective experience of PET/CT were examined using two self-report questionnaires. The pre-procedure questionnaire focused on demographic information, level of knowledge regarding the scan and subjective perception of anxiety before the procedure. The post-procedure questionnaire included the subjective perception anxiety after the procedure, information adequacy and satisfaction with the NM department. The self-reported data indicate that patients were anxious during PET/CT. Furthermore, our data revealed a significant difference between the anxiety pre-procedure and post-procedure (z = -3909, p < 0.05), in which the anxiety pre-procedure has significantly higher values. No significant correlation was found between anxiety and age of the patients, education levels, adequacy of information or satisfaction with the NM Department. Perception of anxiety post-procedure differs between gender (U = 5641, p = 0.033). In conclusion, PET/CT generated anxiety levels in oncological patients, especially before the procedure. Although patients seemed to be satisfied with information delivered by staff and with the NM Department, attention has to be focused on effective interventions strategies that help patients to reduce anxiety.
Resumo:
Mestrado em Medicina Nuclear - Área de especialização: Tomografia por Emissão de Positrões