881 resultados para Installation septique
Resumo:
This study presents a comparative analysis of methodologies about weighted factors considered in the selection of areas for deployment of Sanitary Landfills, applying the methodologies of classification criteria with scoring bands Gomes, Coelho, Erba & Veronez (2000); Waquil et al, 2000. That means, we have the Scoring System used by Union of Municipalities of Bahia and the Quality Index Landfill Waste (IQR) which are applyed for this study in Massaranduba Sanitary Landfill located in the municipality of Ceará Mirim /RN, northeastern of Brazil. The study was conducted in order to classify the methodologies and to give support for future studies on environmental management segment, with main goal to propose suited methodologies which allow safety and rigor during the selection, deployment and management of sanitary landfill, in the Brazilian municipalities, in order to help them in the process to extinction of their dumps, in according of Brazilian Nacional Plan of Solid Waste. During this investigation we have studied the characteristics of the site as morphological, hydrogeological, environmental and socio-economic to permit the installation. We consider important to mention the need of deployment from Rio Grande do Norte State Secretary of Environment and Water (SEMARH), Institute of Sustainable Development and Environment of RN (IDEMA), as well, from Federal and Municipal Governments a public policies for the integrated management of urban solid waste that address environmental preservation and improvement of health conditions of the population of the Rio Grande do Norte
Resumo:
Public investments in the development of innovation in the country, either through the rigging of public universities, either through public announcements of the promotion, increased dramatically in recent years. To analyze the efficiency and effectiveness of the use of public resources is especially in times of austerity, essential for the development of a country. In this context, this research aims to identify the influence of public investments to promote innovation in the degree of maturity of innovative companies in the state of the RN. Another goal is to identify the regional influence from the installation site - capital or countryside, in the performance of the companies studied in the degree of innovation. The theoretical basis of the understanding of the scope of the concept of innovation and its determination for the purposes of this study. Typology, degree of innovation, evaluation methodologies and mechanisms to support innovation : Still on the theme of innovation additional concepts that help the reader to a greater understanding, such as are presented. Following is approached conceptualization of the triple helix, highlighting the concepts advocated by Etzkowitz and Leydesdorff, Salomon and Silva and Ipiranga, Freitas and Paiva, among others. With regard to methodological aspects, we propose a descriptive, exploratory and explanatory research quantitative and qualitative approach with the target audience group of companies served by INOVA PRO- NAGI design - multi-institutional action from a public resource called FINEP promotes the development of innovative companies in the State of Rio Grande do Norte - in 2013. The research should provide reflection and understanding of the influence of public investment in innovation, which by means of qualitative predictive variables associated with quantitative method to explain which variables are significant variations in the degree of maturity of enterprises studied
Resumo:
The usual programs for load flow calculation were in general developped aiming the simulation of electric energy transmission, subtransmission and distribution systems. However, the mathematical methods and algorithms used by the formulations were based, in majority, just on the characteristics of the transmittion systems, which were the main concern focus of engineers and researchers. Though, the physical characteristics of these systems are quite different from the distribution ones. In the transmission systems, the voltage levels are high and the lines are generally very long. These aspects contribute the capacitive and inductive effects that appear in the system to have a considerable influence in the values of the interest quantities, reason why they should be taken into consideration. Still in the transmission systems, the loads have a macro nature, as for example, cities, neiborhoods, or big industries. These loads are, generally, practically balanced, what reduces the necessity of utilization of three-phase methodology for the load flow calculation. Distribution systems, on the other hand, present different characteristics: the voltage levels are small in comparison to the transmission ones. This almost annul the capacitive effects of the lines. The loads are, in this case, transformers, in whose secondaries are connected small consumers, in a sort of times, mono-phase ones, so that the probability of finding an unbalanced circuit is high. This way, the utilization of three-phase methodologies assumes an important dimension. Besides, equipments like voltage regulators, that use simultaneously the concepts of phase and line voltage in their functioning, need a three-phase methodology, in order to allow the simulation of their real behavior. For the exposed reasons, initially was developped, in the scope of this work, a method for three-phase load flow calculation in order to simulate the steady-state behaviour of distribution systems. Aiming to achieve this goal, the Power Summation Algorithm was used, as a base for developing the three phase method. This algorithm was already widely tested and approved by researchers and engineers in the simulation of radial electric energy distribution systems, mainly for single-phase representation. By our formulation, lines are modeled in three-phase circuits, considering the magnetic coupling between the phases; but the earth effect is considered through the Carson reduction. It s important to point out that, in spite of the loads being normally connected to the transformer s secondaries, was considered the hypothesis of existence of star or delta loads connected to the primary circuit. To perform the simulation of voltage regulators, a new model was utilized, allowing the simulation of various types of configurations, according to their real functioning. Finally, was considered the possibility of representation of switches with current measuring in various points of the feeder. The loads are adjusted during the iteractive process, in order to match the current in each switch, converging to the measured value specified by the input data. In a second stage of the work, sensibility parameters were derived taking as base the described load flow, with the objective of suporting further optimization processes. This parameters are found by calculating of the partial derivatives of a variable in respect to another, in general, voltages, losses and reactive powers. After describing the calculation of the sensibility parameters, the Gradient Method was presented, using these parameters to optimize an objective function, that will be defined for each type of study. The first one refers to the reduction of technical losses in a medium voltage feeder, through the installation of capacitor banks; the second one refers to the problem of correction of voltage profile, through the instalation of capacitor banks or voltage regulators. In case of the losses reduction will be considered, as objective function, the sum of the losses in all the parts of the system. To the correction of the voltage profile, the objective function will be the sum of the square voltage deviations in each node, in respect to the rated voltage. In the end of the work, results of application of the described methods in some feeders are presented, aiming to give insight about their performance and acuity
Resumo:
Foram conduzidos três ensaios para avaliar os níveis de energia metabolizável (EM) e a melhor relação energia:proteína (E:P) para aves de corte machos de crescimento lento criadas em semiconfinamento nas fases inicial (1 a 21), de crescimento (22 a 49) e de terminação (50 a 70 dias de idade). em cada ensaio, 400 machos da linhagem ISA Label na fase de criação foram alojados em instalação experimental constituída de 20 piquetes com área coberta de 3,13 m²para alimentação e recolhimento das aves e uma área de pastejo de 72,87 m². O delineamento experimental foi o inteiramente casualizado com cinco tratamentos e quatro repetições de 20 aves. Os níveis de energia metabolizável fornecidos na ração na fase inicial variaram de 2.600 a 3.200 kcal/kg; na fase de crescimento de 2.700 a 3.300 kcal/kg; e na fase final de 2.800 a 3.400 kcal/kg. A proteína bruta e os demais nutrientes foram mantidos constantes em todas as rações, de acordo com recomendações do NRC (1994) para cada fase. A relação energia:proteína e o nível de energia metabolizável que melhoraram o desempenho e as características da carcaça de frangos de corte ISA Label machos criados em sistema semiconfinado em cada fase estudada foram 128 e 2.750; 147 e 2.850 e 172 e 3.100 kcal de EM/kg nas fases inicial, de crescimento e de terminação, respectivamente.
Resumo:
The usual programs for load flow calculation were in general developped aiming the simulation of electric energy transmission, subtransmission and distribution systems. However, the mathematical methods and algorithms used by the formulations were based, in majority, just on the characteristics of the transmittion systems, which were the main concern focus of engineers and researchers. Though, the physical characteristics of these systems are quite different from the distribution ones. In the transmission systems, the voltage levels are high and the lines are generally very long. These aspects contribute the capacitive and inductive effects that appear in the system to have a considerable influence in the values of the interest quantities, reason why they should be taken into consideration. Still in the transmission systems, the loads have a macro nature, as for example, cities, neiborhoods, or big industries. These loads are, generally, practically balanced, what reduces the necessity of utilization of three-phase methodology for the load flow calculation. Distribution systems, on the other hand, present different characteristics: the voltage levels are small in comparison to the transmission ones. This almost annul the capacitive effects of the lines. The loads are, in this case, transformers, in whose secondaries are connected small consumers, in a sort of times, mono-phase ones, so that the probability of finding an unbalanced circuit is high. This way, the utilization of three-phase methodologies assumes an important dimension. Besides, equipments like voltage regulators, that use simultaneously the concepts of phase and line voltage in their functioning, need a three-phase methodology, in order to allow the simulation of their real behavior. For the exposed reasons, initially was developped, in the scope of this work, a method for three-phase load flow calculation in order to simulate the steady-state behaviour of distribution systems. Aiming to achieve this goal, the Power Summation Algorithm was used, as a base for developping the three phase method. This algorithm was already widely tested and approved by researchers and engineers in the simulation of radial electric energy distribution systems, mainly for single-phase representation. By our formulation, lines are modeled in three-phase circuits, considering the magnetic coupling between the phases; but the earth effect is considered through the Carson reduction. Its important to point out that, in spite of the loads being normally connected to the transformers secondaries, was considered the hypothesis of existence of star or delta loads connected to the primary circuit. To perform the simulation of voltage regulators, a new model was utilized, allowing the simulation of various types of configurations, according to their real functioning. Finally, was considered the possibility of representation of switches with current measuring in various points of the feeder. The loads are adjusted during the iteractive process, in order to match the current in each switch, converging to the measured value specified by the input data. In a second stage of the work, sensibility parameters were derived taking as base the described load flow, with the objective of suporting further optimization processes. This parameters are found by calculating of the partial derivatives of a variable in respect to another, in general, voltages, losses and reactive powers. After describing the calculation of the sensibility parameters, the Gradient Method was presented, using these parameters to optimize an objective function, that will be defined for each type of study. The first one refers to the reduction of technical losses in a medium voltage feeder, through the installation of capacitor banks; the second one refers to the problem of correction of voltage profile, through the instalation of capacitor banks or voltage regulators. In case of the losses reduction will be considered, as objective function, the sum of the losses in all the parts of the system. To the correction of the voltage profile, the objective function will be the sum of the square voltage deviations in each node, in respect to the rated voltage. In the end of the work, results of application of the described methods in some feeders are presented, aiming to give insight about their performance and acuity
Resumo:
At present, the electricity generation through wind energy has an importance growing in the world, with the existence of very large plans for future wind power installation worldwide. Thus, the increasing the electricity generation through wind power requires, more and more, analysis of studies of interaction between wind parks and electric power systems. This paper has as purposes to implement equivalent models for synchronous wind generators to represent a wind park in ATP program and to check behavior of the models through simulations. Simulations with applications of faults were achieved to evaluate the behavior of voltages of system for each equivalent model, through comparisons between the results of models proposed, to verify if the differences obtained allows the adoption of the simplest model
Resumo:
A produção de biogás por meio de biodigestão anaeróbia representa um avanço para equacionar o problema dos dejetos produzidos pela suinocultura e disponibilidade de energia no meio rural. Este trabalho teve como objetivo estimar a viabilidade econômica de um sistema biointegrado para geração de eletricidade a partir do aproveitamento de dejetos de suínos. Os dados para este estudo foram coletados em uma agroindústria, onde são realizadas diversas atividades agrícolas; entretanto, a suinocultura foi selecionada para o processo de análise de biodigestão anaeróbia, pelo fato de gerar uma grande quantidade de dejetos, com dificuldade de disposição no meio ambiente, configurando um estudo de caso. O biodigestor analisado é um modelo tubular contínuo, com calha de água em alvenaria e com uma manta plástica como gasômetro, onde são depositados diariamente os dejetos de 2.300 suínos em fase de terminação. O investimento inicial para implantação foi estimado em R$ 51.537,17, e os custos anuais do sistema foram de R$ 5.708,20 com manutenção, R$ 4.390,40 com depreciação e R$ 1.366,77 com juros. Concluiu-se que o sistema de produção de biogás é viável do ponto de vista econômico, se o consumo de energia elétrica for de 35 kWh por dia, em média, onde o valor presente líquido (VLP) é de R$ 9.494,90, e a taxa interna de retorno (TIR) é de 9,34% ao ano.
Resumo:
O presente trabalho objetivou-se na caracterização físico-química de mangas cv. Tommy Atkins e Haden, submetidas ao controle da ação do etileno, através da exposição dos frutos à ação de adsorvedores de etileno. Os frutos colhidos em estádio de fisiologicamente maturos foram embalados em filmes de polietileno de baixa densidade (PEBD) de 0,006 mm de espessura, com ou sem o sachê de adsorção de etileno, e acondicionados em embalagens de papelão (0,65 x 0,52 m), sem o controle da temperatura e da umidade relativa (30 ± 3 ºC e 70 ± 5 % de U.R.). Os tratamentos ficaram constituídos dessa maneira: T1 - mangas cv. Tommy Atkins, com o sachê de adsorção; T2 - mangas cv. Tommy Atkins, sem o sachê de adsorção; T3- mangas cv. Haden com o sachê de adsorção, e T4 - mangas cv Haden sem o sachê de adsorção. As análises de firmeza de polpa, sólidos solúveis (SS), acidez titulável (AT), pH, ácido ascórbico e concentração de etileno foram realizadas na instalação do experimento (dia 0), e aos 7; 14; 21; 28 e 35 dias; e aos 35 dias foi realizado um teste de preferência. Ao final do experimento, observou-se que, em ambas as cultivares, a menor concentração de etileno nas embalagens, a maior firmeza de polpa, a maior contenção no avanço e na diminuição do SS e AT, respectivamente, bem como a melhor manutenção do conteúdo de ácido ascórbico foram detectadas nos frutos acondicionados em embalagens contendo o sachê de adsorção de etileno. Não foram detectadas variações significativas nos valores de pH. No teste de preferência, houve variação significativa, onde os frutos acondicionados sob ação do adsorvedor de etileno foram preferidos por parte dos julgadores.
Resumo:
The castor bean crop (Ricinus communis L.) has acquired prestige due to industries interest in the oil quality and recently for new sources of energy demand. The experiment that served as basis for the data used in this study was conducted at the Lageado Experimental Farm, in Botucatu - SP, 2008. This study aimed to avaluate the crop viability through energy balance and energy efficiency since the implantation until biodiesel production using parameters of consumption in operational management for installation and maintenance of culture harvest and oil production. The soil management operations, sow and harvest consumed the total of 266.20 MJ ha(-1), gathering with the fertilizers, pesticides, fuels, lubricants, labor, seed and industrial processing totaled 56,808 MJ ha(-1) of energy inputs. The energy production was 72,814.00 MJ ha(-1). The industry still lacks studies thal would contribution data collection and more specific energy coefficients. The castor beans cultivation was considered efficient allowing again of 15983.44 MJ ha(-1) equivalent to about 415 liters of diesel oil.
Resumo:
The evolution of automation in recent years made possible the continuous monitoring of the processes of industrial plants. With this advance, the amount of information that automation systems are subjected to increased significantly. The alarms generated by the monitoring equipment are a major contributor to this increase, and the equipments are usually deployed in industrial plants without a formal methodology, which entails an increase in the number of alarms generated, thus overloading the alarm system and therefore the operators of such plants. In this context, the works of alarm management comes up with the objective of defining a formal methodology for installation of new equipment and detect problems in existing settings. This thesis aims to propose a set of metrics for the evaluation of alarm systems already deployed, so that you can identify the health of this system by analyzing the proposed indices and comparing them with parameters defined in the technical norms of alarm management. In addition, the metrics will track the work of alarm management, verifying if it is improving the quality of the alarm system. To validate the proposed metrics, data from actual process plants of the petrochemical industry were used
Resumo:
The generation of electricity in Brazil is predominantly renewable, with internal hydraulic generation being more than 70% of its energy matrix. The electricity rationing occurred in 2001 due to lack of rain, led the country to increase the participation of alternative energy sources. This need for new sources of energy makes the regional potential to be exploited, which configures the change of generation model from centralized generation to distributed generation. Among the alternative sources of energy, the solar energy is presented as very promising for Brazil, given that most of its territory is located near to the equator line, which implies days with greater number of hours of solar radiation. The state of Rio Grande do Norte (RN) has one of the highest levels of solar irradiation of the Brazilian territory, making it eligible to receive investments for the installation of photovoltaic solar plants. This thesis will present the state-of-the-art in solar photovoltaic power generation and will examine the potential for generation of solar photovoltaic power in Brazil and RN, based on solarimetrics measurements conducted by various institutions and also measurements performed in Natal, the state capital
Resumo:
The use of solar energy for electricity generation has shown a growing interest in recent years. Generally, the conversion of solar energy into electricity is made by PV modules installed on fixed structures, with slope determined by the latitude of the installation site. In this sense, the use of mobile structures with solar tracking, has enabled increased production of the generated energy. However, the performance of these structures depends on the type of tracker and the position control used. In this work, it is proposed position control a strategy applied for a solar tracker, which will be installed in Laboratory of Power Electronics and Renewable Energy (LEPER), located in the Federal University of Rio Grande do Norte (UFRN). The tracker system is of polar type with daily positioning east-west and tilt angle manual adjustment in the seasonal periods, from north to south
Resumo:
The objective of this work, the performance of three varieties of soybean on "Tabuleiros Costeiros" State of Alagoas. The installation of the experiment occurred on March 20, 2006, picking up the parcels on 26 August 2006. The experimental design was a randomized blocks with seven repetitions. The experimental plots consisted of ten rows of 4.0 m in length, spaced 0.50 m. In ten plants per plot were marked certain height of the plant in full bloom stage R2 and point of harvest stage R9 considering the distance between the soil surface and apical end of the main stem, the body weight of 100 seeds, grain production and dry weight in (kg ha(-1)) which are calculated from the production harvested per plot. The soybean plants of three varieties showed height below the minimum required for mechanical harvesting. The three varieties yield or more of the traditionally producing. The average of dry matter accumulation obtained show the variety BRS Tracaja as a good option for the production of forage.
Resumo:
This paper presents an analysis of technical and financial feasibility of the use of a solar system for water heating in a fictitious hotel located in the Northeast region. Thereunto it is used techniques of solar collectors´ sizing and methods of financial mathematics, such as Net Present Value (NPV), Internal Rate of Return (IRR) and Payback. It will also be presented a sensitivity analysis to verify which are the factors that impact the viability of the solar heating. Comparative analysis will be used concerning three cities of distinct regions of Brazil: Curitiba, Belém and João Pessoa. The viability of using a solar heating system will be demonstrated to the whole Brazil, especially to the northeast region as it is the most viable for such an application of solar power because of its high levels of solar radiation. Among the cities examined for a future installation of solar heating systems for water heating in the hotel chain, João Pessoa was the one that has proved more viable.
Resumo:
O presente trabalho objetivou avaliar a distribuição do sistema radicular da figueira 'Roxo de Valinhos' em função da aplicação de níveis de adubação orgânica durante quatro anos. A cultura foi conduzida em Botucatu-SP, no espaçamento de 3 x 2 m, num solo classificado como Nitossolo Vermelho. Os tratamentos corresponderam a níveis crescentes de adubação orgânica com esterco de curral, conforme a recomendação de N para a cultura: testemunha (sem adubação), 25 %; 50 %; 75 %; 100 %; 125 % e 150 % da dose recomendada. A avaliação da distribuição do sistema radicular foi realizada 4 anos após a instalação da cultura, sendo que, de cada planta, foram retiradas quatro amostras a 0-40 cm de distância do tronco, na profundidade de 0-40 cm. As amostras foram submetidas à lavagem e secagem em estufa (65 ºC), para posteriormente avaliar a massa seca das raízes. O sistema radicular mostrou-se mais desenvolvido horizontalmente do que na vertical. O menor peso de raízes foi obtido sem esterco (43,3 g), e o maior, com 150 % da dose de N recomendada (177,7 g).