981 resultados para Inductive method
Resumo:
The properties of thin films depend to a large extent upon their mechanical stability which in turn is dependent on the intrinsic stresses developed during evaporation. This paper describes a simple method for the measurement of stresses in thin films by the use of real-time holographic interferometry.
Resumo:
Radiometric determination methods, such as alpha spectrometry require long counting times when low activities are to be determined. Mass spectrometric techniques as Inductively Coupled Plasma Mass Spectrometry (ICP-MS), Thermal Ionisation Mass Spectrometry (TIMS) and Accelerator Mass Spectrometry (AMS) have shown several advantages compared to traditional methods when measuring long-lived radionuclides. Mass spectrometric methods for determination of very low concentrations of elemental isotopes, and thereby isotopic ratios, have been developed using a variety of ion sources. Although primarily applied to the determination of the lighter stable element isotopes and radioactive isotopes in geological studies, the techniques can equally well be applied to the measurement of activity concentrations of long-lived low-level radionuclides in various samples using “isotope dilution” methods such as those applied in inductively coupled plasma mass spectrometry (ICP-MS). Due to the low specific activity of long-lived radionuclides, many of these are more conveniently detected using mass spectrometric techniques. Mass spectrometry also enables the individual determination of Pu-239 and Pu-240, which cannot be obtained by alpha spectrometry. Inductively Coupled Plasma Mass Spectrometry (ICP-MS) are rapidly growing techniques for the ultra-trace analytical determination of stable and long-lived isotopes and have a wide potential within environmental science, including ecosystem tracers and radio ecological studies. Such instrumentation, of course needs good radiochemical separation, to give best performance. The objectives of the project is to identify current needs and problems within low-level determination of long-lived radioisotopes by ICP-MS, to perform intercalibration and development and improvement of ICP-MS methods for the measurement of radionuclides and isotope ratios and to develop new methods based on modified separation chemistry applied to new auxiliary equipment.
Resumo:
Stability analysis is carried out considering free lateral vibrations of simply supported composite skew plates that are subjected to both direct and shear in-plane forces. An oblique stress component representation is used, consistent with the skew-geometry of the plate. A double series, expressed in Chebyshev polynomials, is used here as the assumed deflection surface and Ritz method of solution is employed. Numerical results for different combinations of side ratios, skew angle, and in-plane loadings that act individually or in combination are obtained. In this method, the in-plane load parameter is varied until the fundamental frequency goes to zero. The value of the in-plane load then corresponds to a critical buckling load. Plots of frequency parameter versus in-plane loading are given for a few typical cases. Details of crossings and quasi degeneracies of these curves are presented.
Resumo:
An algorithm that uses integer arithmetic is suggested. It transforms anm ×n matrix to a diagonal form (of the structure of Smith Normal Form). Then it computes a reflexive generalized inverse of the matrix exactly and hence solves a system of linear equations error-free.
Resumo:
Life cycle assessment (LCA) is used to estimate a product's environmental impact. Using LCA during the earlier stages of design may produce erroneous results since information available on the product's lifecycle is typically incomplete at these stages. The resulting uncertainty must be accounted for in the decision-making process. This paper proposes a method for estimating the environmental impact of a product's life cycle and the associated degree of uncertainty of that impact using information generated during the design process. Total impact is estimated based on aggregation of individual product life cycle processes impacts. Uncertainty estimation is based on assessing the mismatch between the information required and the information available about the product life cycle in each uncertainty category, as well as their integration. The method is evaluated using pre-defined scenarios with varying uncertainty. DOI: 10.1115/1.4002163]
Resumo:
Drug induced liver injury is one of the frequent reasons for the drug removal from the market. During the recent years there has been a pressure to develop more cost efficient, faster and easier ways to investigate drug-induced toxicity in order to recognize hepatotoxic drugs in the earlier phases of drug development. High Content Screening (HCS) instrument is an automated microscope equipped with image analysis software. It makes the image analysis faster and decreases the risk for an error caused by a person by analyzing the images always in the same way. Because the amount of drug and time needed in the analysis are smaller and multiple parameters can be analyzed from the same cells, the method should be more sensitive, effective and cheaper than the conventional assays in cytotoxicity testing. Liver cells are rich in mitochondria and many drugs target their toxicity to hepatocyte mitochondria. Mitochondria produce the majority of the ATP in the cell through oxidative phosphorylation. They maintain biochemical homeostasis in the cell and participate in cell death. Mitochondria is divided into two compartments by inner and outer mitochondrial membranes. The oxidative phosphorylation happens in the inner mitochondrial membrane. A part of the respiratory chain, a protein called cytochrome c, activates caspase cascades when released. This leads to apoptosis. The aim of this study was to implement, optimize and compare mitochondrial toxicity HCS assays in live cells and fixed cells in two cellular models: human HepG2 hepatoma cell line and rat primary hepatocytes. Three different hepato- and mitochondriatoxic drugs (staurosporine, rotenone and tolcapone) were used. Cells were treated with the drugs, incubated with the fluorescent probes and then the images were analyzed using Cellomics ArrayScan VTI reader. Finally the results obtained after optimizing methods were compared to each other and to the results of the conventional cytotoxicity assays, ATP and LDH measurements. After optimization the live cell method and rat primary hepatocytes were selected to be used in the experiments. Staurosporine was the most toxic of the three drugs and caused most damage to the cells most quickly. Rotenone was not that toxic, but the results were more reproducible and thus it would serve as a good positive control in the screening. Tolcapone was the least toxic. So far the conventional analysis of cytotoxicity worked better than the HCS methods. More optimization needs to be done to get the HCS method more sensitive. This was not possible in this study due to time limit.
Resumo:
A novel geodesic constant method has been developed for the hitherto unsolved problem of surface-ray tracing over a class of surface, namely the general hyperboloid of revolution (GHOR). All the ray-geometric parameters are obtained analytically in a one-parameter form. The ray parameters derived here for the first time can be readily used in the UTD formulation for computing the mutual coupling between the antennas located on the GHOR.
Resumo:
A method has been suggested to accurately determine the DBTT of diffusion aluminide bond coats. Micro-tensile testing of free-standing coating samples has been carried out. The DBTT was determined based on the variation of plastic strain-to-fracture with temperature. The positive features of this method over the previously reported techniques are highlighted. (C) 2010 Elsevier B.V. All rights reserved.
Resumo:
"In rats, sucking milk reduces anxiety and promotes non-rapid eye movement (NREM) sleep, and in calves it induces resting but the effect on sleep is unknown. Here, we investigated how calves' sleep was affected by colostrum feeding methods. Forty-one calves were blocked by birth date and randomly allotted within blocks to the experimental treatments. Calves were housed for four days either with their dam (DAM) or individually with warm colostrum feeding (2 L four times a day) from either a teat bucket (TEAT) or an open bucket (BUCKET). DAM calves suckled their dam freely. Calves' sleeping and sucking behaviour was filmed continuously for 48 h at the ages of two and three days. Behavioural sleep (BS) was defined as calves resting at least 30 s with their head still and raised (non-rapid eye movement) or with their head against their body or the ground (rapid eye movement, REM). Latency from the end of colostrum feeding to the start of BS was recorded. We compared behaviour of TEAT calves with that of DAM and BUCKET calves using mixed models. Milk meal duration was significantly longer for TEAT calves than for BUCKET calves (mean +/- S.E.M.; 8.3 +/- 0.6 min vs. 5.2 +/- 0.6 min), but equal to that of DAM calves. We found no effect of feeding method on the duration of daily BS (12 h 59 min I h 38 min) but we found a tendency for the daily amount of NREM sleep; BUCKET calves had less NREM sleep per day than TEAT calves (6 h 18 min vs. 7 h 48 min, S.E.M. = 45 min) and also longer latencies from milk ingestion to BS (21.9 +/- 2.0 min vs. 16.2 +/- 2.0 min). DAM calves slept longer bouts than TEAT calves (10.8 +/- 1.0 min vs. 8.3 +/- 1.0 min) and less often (78 +/- 4 vs. 92 +/- 4). Sucking colostrum from a teat bucket compared with drinking from an open"