936 resultados para IMPLANT PLACEMENT


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this paper was to evaluate the expression of RANK protein during bone-healing process around machined surface implants. Twenty male Wistar rats, 90 days old, after having had a 2 mm diameter and 6 mm long implant inserted in their right tibias, were evaluated at 7, 14, 21, and 42 days after healing. After obtaining the histological samples, slides were subjected to RANK immunostaining reaction. Results were quantitatively evaluated. Results. Immunolabeling analysis showed expressions of RANK in osteoclast and osteoblast lineage cells. The statistical analysis showed an increase in the expression of RANK in osteoblasts at 7 postoperative days and a gradual decrease during the chronology of the healing process demonstrated by mild cellular activity in the final stage (P < .05). Conclusion. RANK immunolabeling was observed especially in osteoclast and osteoblast cells in primary bone during the initial periods of bone-healing/implant interface.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A white female patient presented to the university clinic to obtain implant retained prostheses. She had an edentulous maxillary jaw and presented three teeth with poor prognosis (33, 34 and 43). The alveolar bone and the surrounding tissues were healthy. The patient did not report any relevant medical history contraindicating routine dental treatment or implant surgery, but self-reported a dental history of asymptomatic nocturnal bruxism. The treatment plan was set and two Branemark protocols supported by six implants in each arch were installed after a 6-month healing period. A soft occlusal splint was made due to the patient's history of bruxism, and the lack of its use by the patient resulted in an acrylic fracture. The prosthesis was repaired and the importance of using the occlusal splint was restated. In the 4-year follow-up no fractures were reported.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This report describes a protocol for managing the accidental swallowing of dental instruments in implant dentistry, illustrated by a patient who accidentally swallowed a hexagonal wrench. The first step was to refer the patient to the medical emergency hospital service for radiographic and clinical evaluation. The hexagonal wrench was located in the stomach and was immediately removed with an endoscopic procedure. The gastric mucosa was sampled via biopsy and the sample submitted to the urease test, which was positive for Helicobacter pylori. Triple treatment was instituted for gastritis caused by H pylori to avoid exposing the patient to unnecessary risk. Removal of a foreign body by means of an endoscopic procedure constitutes a safe and effective treatment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this paper was to present a rehabilitation of a patient with a dynamic universal castable long abutment (UCLA) for a single tilted implant in the anterior maxillary area. A 57-year-old male patient attended the dentistry college clinic complaining of a vertical fracture of a residual root of the dental element 22. The tooth extraction was indicated for the implant installation. Due to the socket buccal wall thickness, the implant was installed with an inclination to the palate. It was done in a two-stage surgical protocol, and an external hexagon implant (3.75×11.5mm) was placed. After a six-month healing period to correct the implant position, a dynamic UCLA was set in place, rectifying the implant emergence profile at 20°. The ceramic structure fitting was performed and, after the patient's consent, the prosthesis was finalized and installed. After a follow-up period of twenty months, no complications were observed. The installation of tilted implants with a dynamic UCLA may be a viable option, faster and less invasive than bone grafts.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To compare peri-implant soft- and hard-tissue integration at implants installed juxta- or sub-crestally. Furthermore, differences in the hard and soft peri-implant tissue dimensions at sites prepared with drills or sonic instruments were to be evaluated. Three months after tooth extraction in six dogs, recipient sites were prepared in both sides of the mandible using conventional drills or a sonic device (Sonosurgery(®) ). Two implants with a 1.7-mm high-polished neck were installed, one with the rough/smooth surface interface placed at the level of the buccal bony crest (control) and the second placed 1.3 mm deeper (test). After 8 weeks of non-submerged healing, biopsies were harvested and ground sections prepared for histological evaluation. The buccal distances between the abutment/fixture junction (AF) and the most coronal level of osseointegration (B) were 1.6 ± 0.6 and 2.4 ± 0.4 mm; between AF and the top of the bony crest (C), they were 1.4 ± 0.4 and 2.2 ± 0.2 mm at the test and control sites, respectively. The top of the peri-implant mucosa (PM) was located more coronally at the test (1.2 ± 0.6 mm) compared to the control sites (0.6 ± 0.5 mm). However, when the original position of the bony crest was taken into account, a higher bone loss and a more apical position of the peri-implant mucosa resulted at the test sites. The placement of implants into a sub-crestal location resulted in a higher vertical buccal bone resorption and a more apical position of the peri-implant mucosa in relation to the level of the bony crest at implant installation. Moreover, peri-implant hard-tissue dimensions were similar at sites prepared with either drills or Sonosurgery(®) .

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Backgroud: The influence of diamond-like-carbon (DLC) films on bacterial leakage through the interface between abutments and dental implants of external hexagon (EH) and internal hexagon (IH) was evaluated. Film deposition was performed by PECVD (Plasma Enhanced Chemical Vapor Deposition). Sets of implants and abutments (N=180, n=30) were divided according to the connection design and the treatment of the abutment base: (1) no treatment (control); (2) DLC film deposition, and (3) Ag-DLC film deposition. Under sterile conditions, 1 µL of Enterococcus faecalis was inoculated inside the implants, and abutments were tightened. The sets were tested for immediate external contamination, suspended in test tubes containing sterile culture broth, and followed-up for five days. Turbidity of the broth indicated bacterial leakage. At the end of the period, the abutments were removed and the internal content of the implants was collected with paper points and plated in Petri dishes. They were incubated for 24 h for bacterial viability assessment and colony-forming unit (CFU) counting. Bacterial leakage was analyzed by Chi-square and Fisher exact tests (α=5%). The percentage of bacterial leakage was 16.09% for EH implants and 80.71% for IH implants (P<0.0001). The bacterial load was higher inside these implants (P=0.000). The type of implant significantly influenced the results (P=0.000), whereas the films did not (P=0.487). We concluded that: (1) IH implants showed a higher frequency of bacterial leakage and (2) the DLC and Ag-DLC films did not significantly reduce the frequency of bacterial leakage and bacteria load inside the implants.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to evaluate the possibility to obtaining guided bone regeneration utilizing a nonporous PTFE barrier in the osseointegrated implants, protruding from the bone level of the rabbit tíbia. The histologic characteristics of the interface between titanium implants, one group titanium-plasma coated, another group with acid-treated surfaces and the regenerated bone were also studied Twenty Screw-Vent implants were placed in tibias of five rabbits, two at the right side and two at the left side, protruding 3 mm from the bone level, to create a horizontal bone defect. ln the experimental side, the implants and adjacent bone were protected with a nonporous PTFE barrier. Histologic analysis after three months showed that all implants were in direct contact with the bane. Histologic measurements showed an average gain in bone height of the 2.15 and 2.42 mm for the barrier group and 1.95 and 0.43 mm for the control defects, in the titanium plasma-spray and acid-treated implant surfaces, respectively. The results suggest that the placement of implants protruding 3 mm from crestal bone defects may result in vertical bone augmentation and the regenerated bone is able to osseointegrate implants. lt seems to be critical the use of the PTFE barrier when acid-treated surface implants are inserted

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This case report is an 8-year follow-up of a malpositioned single implant, which was treated with segmental osteotomy, to confirm the treatment's characteristics, indications, and advantages. Deep buccal positioning of an endosseous implant placed in the maxillary left central incisor area did not permit acceptable prosthetic rehabilitation, despite its favorable bone insertion with no significant marginal bone loss. The surgical procedure included osteotomy and block movement performed toward the lingual and cervical position, fixed with a provisional prosthesis and miniplates and mini-implants. A connective tissue graft was necessary for esthetics optimization and was performed in a second stage. Advantages including the prevention of alveolar ridge damage, the improvement of gingival contour, and the use of an already integrated implant are presented. Clinically satisfactory hard and soft tissue stability permitted us to consider segmental surgery as a reliable alternative for malpositioned osseointegrated implants.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Studies have reported that alcohol may lead to imbalance in bone formation and resorption, however, its effects on osseointegration of titanium implants continues to be an inconclusive subject. In this context, the aim of this study was to make a biomechanical evaluation of the effect of abusive alcohol consumption on the removal torque of osseointegrated titanium implants. Male Wistar rats (n=30) were divided into two experimental groups (15 each) receiving only water (Control) or 36% alcohol solution oral administration. Thirty days later, all animals were submitted to titanium implant (2.2 mm x 4 mm) placement in the right and left tibiae. The surgical alveoli were prepared with a 2 mm drill mounted in a counter-angle hand-piece (20:1 ratio, 35 Ncm torque at 1200 rpm) under abundant cooling. Five animals from each group were euthanized at 15, 30, and 60 days. Tibiae were submitted to reverse torque analysis. Data obtained were submitted to statistical analysis by the non-parametric Kruskal-Wallis and Dunn Tests (p < 0.05). Animals in the alcohol group presented lower removal torque values when compared with control group animals for all periods tested (p < 0.05). It can be concluded that abusive alcohol consumption can reduce the removal torque of titanium implants placed in rat tibiae, suggesting that alcohol may interfere in the osseointegration process of titanium implants.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Studies have reported that alcohol may lead to imbalance in bone formation and resorption, however, its effects on osseointegration of titanium implants continues to be an inconclusive subject. In this context, the aim of this study was to make a biomechanical evaluation of the effect of abusive alcohol consumption on the removal torque of osseointegrated titanium implants. Male Wistar rats (n=30) were divided into two experimental groups (15 each) receiving only water (Control) or 36% alcohol solution oral administration. Thirty days later, all animals were submitted to titanium implant (2.2 mm x 4 mm) placement in the right and left tibiae. The surgical alveoli were prepared with a 2 mm drill mounted in a counter-angle hand-piece (20:1 ratio, 35 Ncm torque at 1200 rpm) under abundant cooling. Five animals from each group were euthanized at 15, 30, and 60 days. Tibiae were submitted to reverse torque analysis. Data obtained were submitted to statistical analysis by the non-parametric Kruskal-Wallis and Dunn Tests (p < 0.05). Animals in the alcohol group presented lower removal torque values when compared with control group animals for all periods tested (p < 0.05). It can be concluded that abusive alcohol consumption can reduce the removal torque of titanium implants placed in rat tibiae, suggesting that alcohol may interfere in the osseointegration process of titanium implants.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The increased prevalence of diabetic individuals has become a public health problem. Diabetes Mellitus is a metabolic disorder characterized by an increase in plasma glucose levels. It impairs the physiological equilibrium in utilization of carbohydrate by tissues. The persistent hyperglycemia can produce deleterious effects on bone formation due the microvascular complication. The present paper reviews the bibliography linking the impact of glycemic control at complications associated at diabetes mellitus on osseointegration. In experimental models of diabetes it was observed a reduced level of bone-implant contact. This failure can be reduced by means of hyperglycemia control. Also, several studies point the beneficial effect of coated implant on osseointegration process. It is necessary to take special care into account for the placement of implants in diabetic patient and improve the percentages of implant survival. A rigorous control of plasma glycaemia, together with other measures, like as absence of chronic complications, good oral hygiene and regular medical follow-up has been related to rising the percentages of successful in diabetic patients.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The aim of this study was to assess the contributions of some prosthetic parameters such as crown-to-implant (C/I) ratio, retention system, restorative material, and occlusal loading on stress concentrations within a single posterior crown supported by a short implant. Materials and Methods: Computer-aided design software was used to create 32 finite element models of an atrophic posterior partially edentulous mandible with a single external-hexagon implant (5 mm wide × 7 mm long) in the first molar region. Finite element analysis software with a convergence analysis of 5% to mesh refinement was used to evaluate the effects of C/I ratio (1:1; 1.5:1; 2:1, or 2.5:1), prosthetic retention system (cemented or screwed), and restorative material (metal-ceramic or all ceramic). The crowns were loaded with simulated normal or traumatic occlusal forces. The maximum principal stress (σmax) for cortical and cancellous bone and von Mises stress (σvM) for the implant and abutment screw were computed and analyzed. The percent contribution of each variable to the stress concentration was calculated from the sum of squares analysis. Results: Traumatic occlusion and a high C/I ratio increased stress concentrations. The C/I ratio was responsible for 11.45% of the total stress in the cortical bone, whereas occlusal loading contributed 70.92% to the total stress in the implant. The retention system contributed 0.91% of the total stress in the cortical bone. The restorative material was responsible for only 0.09% of the total stress in the cancellous bone. Conclusion: Occlusal loading was the most important stress concentration factor in the finite element model of a single posterior crown supported by a short implant.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Processo FAPESP: 2012/24545-3