977 resultados para HIGHLY REACTIVE ORGANOLANTHANIDES
Resumo:
The electron emission induced by highly charged ions Pb-207(q+) (24 <= q <= 36) interacting with Si(110) surface is reported. The result shows that the electron emission yield Y has a strong dependence on the projectile charge state q, incidence angle psi and impact energy E. In fitting the experimental data we found a nearly 1/tan psi dependence of Y. Theoretical analysis shows that these processes are closely related to the process of potential electron emission based on the classical over-the-barrier model.
Resumo:
Spectra for Delta n = 0 transitions of the type 2s(2)2p(k)-2s2p(k+1) or 2s2p(k)-2p(k+1) from highly ionized sulfur produced in beam-foil excitation are investigated and compared to similar spectra measured with other types of light sources. In the experiment, fifty lines have been identified, of which eleven lines are new and accurately measured. Analysis of spectra was based on comparisons with other experimental results and calculated values.
Resumo:
There has been increasing demand to provide higher beam intensity and high enough beam energy for heavy ion accelerator and some other applications, which has driven electron cyclotron resonance (ECR) ion source to produce higher charge state ions with higher beam intensity. One of development trends for highly charged ECR ion source is to build new generation ECR sources by utilization of superconducting magnet technology. SECRAL (superconducting ECR ion source with advanced design in Lanzhou) was successfully built to produce intense beams of highly charged ion for Heavy Ion Research Facility in Lanzhou (HIRFL). The ion source has been optimized to be operated at 28 GHz for its maximum performance. The superconducting magnet confinement configuration of the ion source consists of three axial solenoid coils and six sextupole coils with a cold iron structure as field booster and clamping. An innovative design of SECRAL is that the three axial solenoid coils are located inside of the sextupole bore in order to reduce the interaction forces between the sextupole coils and the solenoid coils. For 28 GHz operation, the magnet assembly can produce peak mirror fields on axis of 3.6 T at injection, 2.2 T at extraction, and a radial sextupole field of 2.0 T at plasma chamber wall. During the commissioning phase at 18 GHz with a stainless steel chamber, tests with various gases and some metals have been conducted with microwave power less than 3.5 kW by two 18 GHz rf generators. It demonstrates the performance is very promising. Some record ion beam intensities have been produced, for instance, 810 e mu A of O7+, 505 e mu A of Xe20+ 306 e mu A of Xe27+, and so on. The effect of the magnetic field configuration on the ion source performance has been studied experimentally. SECRAL has been put into operation to provide highly charged ion beams for HIRFL facility since May 2007.
Resumo:
The electron impact excitation (EIE) cross sections from the ground state to all of the 2s(2)2p(5)3l and 2s2p(6)3l(l=s, p, d) states along the Ne-like isoelectronic sequence of ions (Z = 50-57) have been calculated by using the multiconfiguration Dirac-Fock package GRASP92 and the fully relativistic distorted-wave program REIE06. In the calculations, the relativistic effects and electron correlation effects are considered systematically. Based on those calculations, the EIE cross sections along the Ne-like isoelectronic sequence of ions for different incident electron energies are discussed, and some important conclusions are drawn. We also study the influence of the correlation effects on the values of the 3C/3D line-intensity ratio [3C: (2p(1/2)3d(3/2))(1) -> 2s(2)2p(6) S-1(0), 3D: (2p(3/2)3d(5/2))(1) -> 2s(2)2p(6) S-1(0)] along the Ne-like sequence. A comparison is made between the present results and previous theoretical calculations and experimental results for the EIE cross sections in Ba-46 (+) ions, and a good agreement is obtained.
Resumo:
The electron emission yields from the interaction of slow highly charged ions (SHCI) He2+, O2+ and Ne2+ with clean Si surface are measured separately. It is found that electron emission yield gamma increases proportionally to projectile kinetic energy E-p/M-p, ranging from 0.75 keV/u to 10.5 keV/u (i.e. 3.8 x 10(5) m/s <= v(p) <= 1.42 x 10(6) m/s), and it is higher for heavy ions (O2+ and Ne2+) than for light ion (He2+). For O2+ and Ne2+, gamma increases with Z(p) decreasing in our energy range, and it shows quite different from the result for higher projectile kinetic energy. After calculating the stopping power by using TRIM 2006, it is found that the fraction of secondary electrons induced by recoil atoms increases significantly at lower projectile energy, thereby leads to the differences in gamma for heavy ions O2+ and Ne2+ between lower and higher projectile kinetic energy.
Resumo:
在兰州重离子加速器国家实验室电子回旋共振离子源高电荷态原子物理实验平台上,用低能(0.75keV/u≤EP/MP≤10.5keV/u,即3.8×105m/s≤vP≤1.42×106m/s)He2+,O2+和Ne2+离子束正入射到自清洁Si表面时二次电子发射产额的实验结果.结果表明电子发射产额γ近似正比于入射离子动能EP/MP.在相同动能下,γ(O)>γ(Ne)>γ(He),对于原子序数ZP比较大的O2+和Ne2+离子,ZP大者反而γ小,这与较高入射能量时的结果截然不同.通过计算不同入射能量下入射离子的阻止能损S,发现反冲原子对激发二次电子的作用随入射离子能量的降低显著增大,这正是导致在较低能量范围内二次电子发射产额与较高入射能量时存在差异的主要原因.
Resumo:
为了研究低速高电荷态离子在C60薄膜中引起的势效应,用能量为200keV的高电荷态Xen+(n=3,10,13,15,17,20,22,23)离子辐照了C60薄膜。用原子力显微镜(AFM)和Raman散射技术分析了辐照过程中高电荷态Xen+离子所储存势能在C60薄膜中引起的效应,即势效应。AFM分析结果表明,辐照C60薄膜的表面粗糙度随辐照Xen+离子电荷态(即势能)的增加而减小,揭示了势效应的存在。而Raman分析结果表明,由于Xe离子的动能远大于其所储存的势能,因此,尽管有表面势效应的影响,但在Raman分析的深度范围内,弹性碰撞还是主导了C60薄膜的损伤过程。
Resumo:
We utilize slow highly charged ions of Xeq+ and Pbq+ to irradiate GaN crystal films grown on sapphire substrate, and use X-ray photoelectron spectroscopy to analyze its surface chemical composition and chemical state of the elements. The results show that highly charged ions can etch the sample surface obviously, and the GaN sample irradiated by highly charged ions has N depletion or is Ga rich on its surface. Besides, the relative content of Ga-Ga bond increases as the dose and charge state of the incident ions increase. In addition, the binding energy of Ga 3d(5/2) electrons corresponding to Ga-Ga bond of the irradiated GaN sample is smaller compared with that of the Ga bulk material. This can be attributed to the lattice damage, which shifts the binding energy of inner orbital electrons to the lower end.
Resumo:
利用低速高电荷态Xeq+和Pbq+离子对在蓝宝石衬底上生长的GaN晶体膜样品进行辐照,并利用X射线光电子能谱(XPS)对样品表面化学组成和元素化合态进行了分析.结果表明,高电荷态离子对样品表面有显著的刻蚀作用;经高电荷态离子辐照的GaN样品表面氮元素贫乏而镓元素富集;随着入射离子剂量和所携带电荷数的增大,Ga—Ga键相对含量增大;辐照后,GaN样品中Ga—Ga键对应的Ga3d5/2电子的束缚能偏小,晶格损伤使内层轨道电子束缚能向低端方向偏移.
Resumo:
The sputtered particle yields produced by Pbq+ (q=4-36) with constant kinetic energy bombardment on An surface were measured. The sputtering Could be separated to two parts: no potential sputtering is observed when q<24 (E-pot = 9.6 keV) and the sputtering yield increases with E-pot(1.2) for the higher charge states of q >= 24. The potential sputtering is mainly contributed by the relaxation of electronic excitations on target surface produced by the potential energy transfer from projectile to target atoms.
Resumo:
A study of cooled Au-197 projectile-fragmentation products has been performed with a storage ring. This has enabled metastable nuclear excitations with energies up to 3 MeV, and half-lives extending to minutes or longer, to be identified in the neutron-rich nuclides Hf-183,Hf-184,Hf-186 and Ta-186,Ta-187. The results support the prediction of a strongly favored isomer region near neutron number 116.
Resumo:
A Penning trap system called Lanzhou Penning Trap (LPT) is now being developed for precise mass measurements at the Institute of Modern Physics (IMP). One of the key components is a 7 T actively shielded superconducting magnet with a clear warm bore of 156 mm. The required field homogeneity is 3 x 10(-7) over two 1 cubic centimeter volumes lying 220 mm apart along the magnet axis. We introduce a two-step method which combines linear programming and a nonlinear optimization algorithm for designing the multi-section superconducting magnet. This method is fast and flexible for handling arbitrary shaped homogeneous volumes and coils. With the help of this method an optimal design for the LPT superconducting magnet has been obtained.
Resumo:
Superconducting electron cyclotron resonance ion source with advanced design in Lanzhou (SECRAL) is an all-superconducting-magnet electron cyclotron resonance ion source (ECRIS) for the production of intense highly charged ion beams to meet the requirements of the Heavy Ion Research Facility in Lanzhou (HIRFL). To further enhance the performance of SECRAL, an aluminum chamber has been installed inside a 1.5 mm thick Ta liner used for the reduction of x-ray irradiation at the high voltage insulator. With double-frequency (18+14.5 GHz) heating and at maximum total microwave power of 2.0 kW, SECRAL has successfully produced quite a few very highly charged Xe ion beams, such as 10 e mu A of Xe37+, 1 e mu A of Xe43+, and 0.16 e mu A of Ne-like Xe44+. To further explore the capability of the SECRAL in the production of highly charged heavy metal ion beams, a first test run on bismuth has been carried out recently. The main goal is to produce an intense Bi31+ beam for HIRFL accelerator and to have a feel how well the SECRAL can do in the production of very highly charged Bi beams. During the test, though at microwave power less than 3 kW, more than 150 e mu A of Bi31+, 22 e mu A of Bi41+, and 1.5 e mu A of Bi50+ have been produced. All of these results have again demonstrated the great capability of the SECRAL source. This article will present the detailed results and brief discussions to the production of highly charged ion beams with SECRAL.