900 resultados para Forces de compression


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Mecânica - FEG

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Root resorption is a variable to be considered in induced tooth movement (ITM). It is related to root morphology and alveolar bone crest, and also to the types of forces exerted by mechanotherapy. This histometric study evaluated the predominance of root resorption among roots of different dimensions, following ITM with different types of forces and at different time intervals. The study was conducted on 54 rats divided into three groups, according to the type of force: continuous (CF), continuous interrupted (CIF) and intermittent (IF), at periods of 5, 7 and 9 days. The percentage of resorption between mesiobuccal roots of larger dimension and intermediate roots of smaller dimension was assessed. The evaluations were performed on the AxioVision software, and the non-parametric analysis of variance for repeated measures in independent groups was further applied, consisting of a scheme of two factors, and complemented by the Dunn test at a significance level of 5%. The intermediate roots presented a higher percentage of resorption, which was gradual at the periods evaluated for the three types of forces, but mainly for CF. Comparing the intermediate roots with the mesiobuccal roots, there was a statistically significant difference (p < 0.05) in the CF group at day 7 and day 9, and in the FI group, at day 9. The intragroup analysis evidenced a statistically significant difference (p < 0.05) between the 5th and the 9th day for the intermediate root in the CF group. The intergroup analysis did not reveal any statistically significant difference (p > 0.05) in individually analyzed roots.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of the present article is to assess and compare the performance of electricity generation systems integrated with downdraft biomass gasifiers for distributed power generation. A model for estimating the electric power generation of internal combustion engines and gas turbines powered by syngas was developed. First, the model determines the syngas composition and the lower heating value; and second, these data are used to evaluate power generation in Otto, Diesel, and Brayton cycles. Four synthesis gas compositions were tested for gasification with: air; pure oxygen; 60% oxygen with 40% steam; and 60% air with 40% steam. The results show a maximum power ratio of 0.567 kWh/Nm(3) for the gas turbine system, 0.647 kWh/Nm(3) for the compression ignition engine, and 0.775 kWh/Nm(3) for the spark-ignition engine while running on synthesis gas which was produced using pure oxygen as gasification agent. When these three systems run on synthesis gas produced using atmospheric air as gasification agent, the maximum power ratios were 0.274 kWh/Nm(3) for the gas turbine system, 0.302 kWh/Nm(3) for CIE, and 0.282 kWh/Nm(3) for SIE. The relationship between power output and synthesis gas flow variations is presented as is the dependence of efficiency on compression ratios. Since the maximum attainable power ratio of CIE is higher than that of SIE for gasification with air, more research should be performed on utilization of synthesis gas in CIE. (C) 2014 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

SynopsisBackgroundCellulite refers to changes in skin relief on the thighs and buttocks of women, with a prevalence of 80-90%, causing dissatisfaction and search for treatment. Etiopathogenesis is multifactorial, as follows: herniation of the hypodermis towards the dermis, facilitated by perpendicular fibrous septa, changes in the dermal extracellular matrix, decreased adiponectin, genetic polymorphism, microcirculation alterations and inflammatory process. There are numerous therapeutic approaches, with little evidence of effectiveness. The long-wave infrared (LWIR) radiation interacts with water, improves microcirculation and stimulates metabolic processes. To date, the use of tissues with potential reflection of LWIR radiation has not been systematically investigated as adjuvant treatment for cellulite.ObjectiveTo investigate the efficacy and safety of the treatment of cellulite through the use of compression stockings made with thread reflecting LWIR radiation.Patients and methodsClinical study of therapeutic intervention, controlled and double-blind, including 30 women, aging from 25 to 40years, with cellulite of grades II and III on the thighs and buttocks who used compression stockings, pantyhose model, made with reflector thread of LWIR radiation, on only one randomized side. Women under other treatments for cellulite and with venous and/or blood insufficiencies were excluded. Evaluation of efficacy by clinical parameters, photographs, Dermatology Life Quality Index (DLQI), cutometry and high frequency ultrasonography and security by observation of adverse events and venous EcoDoppler recordings.ResultsDLQI scores showed significant reduction; the two-dimensional high-frequency ultrasonography showed an insignificant increase in dermal echogenicity as well as other efficacy parameters demonstrated no or slight improvement, with no differences between the sides exposed or not to LWIR; and there were no severe adverse events.ConclusionCompression stockings, with or without thread reflector of LWIR, showed slight effects in the appearance of cellulite, but the treatment determined a positive impact on women quality of life.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Civil - FEIS

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work, we discuss the procedures adopted for the design of built-up columns (laced and battened columns). Built-up columns are widely used in steel construction generally when the compression forces are relatively low and the column buckling lengths are large. They are commonly used in industrial buildings, for example, as posts for cladding, or as columns supporting a crane girder. Unlike columns with full section, in the case of built-up columns, it is necessary to evaluate the shear stiffness. In fact, the shear strength leads to a significant reduction of the critical load. In the context of this work, the components of the columns (chords, diagonals, posts, etc.) are formed by cold-formed members. In order to systematize and rationalize the verification of the built-up columns, this work aim to develop a computer program based on the standards NBR 14762, NBR 6355 and Eurocode 3, basically the considerations of the part EN 1993-1-1

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work, we discuss the procedures adopted for the design of built-up columns (laced and battened columns). Built-up columns are widely used in steel construction generally when the compression forces are relatively low and the column buckling lengths are large. They are commonly used in industrial buildings, for example, as posts for cladding, or as columns supporting a crane girder. Unlike columns with full section, in the case of built-up columns, it is necessary to evaluate the shear stiffness. In fact, the shear strength leads to a significant reduction of the critical load. In the context of this work, the components of the columns (chords, diagonals, posts, etc.) are formed by cold-formed members. In order to systematize and rationalize the verification of the built-up columns, this work aim to develop a computer program based on the standards NBR 14762, NBR 6355 and Eurocode 3, basically the considerations of the part EN 1993-1-1

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To analyze the shear forces on the vertebral body L4 when submitted to a compression force by means of transmission photoelasticity. Methods: Twelve photoelastic models were divided into three groups, with four models per group, according to the positioning of the sagittal section vertebrae L4-L5 (sections A, B and C). The simulation was performed using a 15N compression force, and the fringe orders were evaluated in the vertebral body L4 by the Tardy compensation method. Results: Photoelastic analysis showed, in general, a homogeneous distribution in the vertebral bodies. The shear forces were higher in section C than B, and higher in B than A. Conclusion: The posterior area of L4, mainly in section C, showed higher shear concentrations, corresponding to a more susceptible area for bone fracture and spondylolisthesis. Economic and Decision Analyses Development of an Economic or Decision Model. Level I

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: This study evaluated the influence of the cavity configuration factor ("C-Factor") and light activation technique on polymerization contraction forces of a Bis-GMA-based composite resin (Charisma, Heraeus Kulzer). Material and Methods: Three different pairs of steel moving bases were connected to a universal testing machine (Emic DL 500): groups A and B - 2x2 mm (CF=0.33), groups C and D - 3x2 mm (CF=0.66), groups E and F - 6x2 mm (CF=1.5). After adjustment of the height between the pair of bases so that the resin had a volume of 12 mm(3) in all groups, the material was inserted and polymerized by two different methods: pulse delay (100 mW/cm(2) for 5 s, 40 s interval, 600 mW/cm(2) for 20 s) and continuous pulse (600 mW/cm(2) for 20 s). Each configuration was light cured with both techniques. Tensions generated during polymerization were recorded by 120 s. The values were expressed in curves (Force(N) x Time(s)) and averages compared by statistical analysis (ANOVA and Tukey's test, p<0.05). Results: For the 2x2 and 3x2 bases, with a reduced C-Factor, significant differences were found between the light curing methods. For 6x2 base, with high C-Factor, the light curing method did not influence the contraction forces of the composite resin. Conclusions: Pulse delay technique can determine less stress on tooth/restoration interface of adhesive restorations only when a reduced C-Factor is present.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Twelve participants ran (9 km . h(-1)) to test two types of running shoes: replica and original shoes. Ground reaction force, plantar pressure and electromyographic activity were recorded. The shoes were tested randomly and on different days. Comparisons between the two experimental conditions were made by analysis of variance (ANOVA) test (P <= 0.05). The time to first peak, loading rate of the first peak and impulse of the first 75 ms of stance were significantly different between the shoes (P <= 0.05), revealing an increase of impact forces for the replica shoes. The peak plantar pressure values were significantly higher (P <= 0.05) when wearing replica shoes. During running, the contact area was significantly smaller (P <= 0.05) for the replica shoe. The electromyographic activity of the analysed muscles did not show changes between the two shoes in running. These findings suggest that the use of replica running shoes can increase the external load applied to the human body, but may not change the muscle activity pattern during locomotion. This new mechanical situation may increase the risk of injuries in these movements.