975 resultados para Evanescent wave fibre optic sensors


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work proposes a fully-digital interface circuit for the measurement of inductive sensors using a low-cost microcontroller (µC) and without any intermediate active circuit. Apart from the µC and the sensor, the circuit just requires an external resistor and a reference inductance so that two RL circuits with a high-pass filter (HPF) topology are formed. The µC appropriately excites such RL circuits in order to measure the discharging time of the voltage across each inductance (i.e. sensing and reference) and then it uses such discharging times to estimate the sensor inductance. Experimental tests using a commercial µC show a non-linearity error (NLE) lower than 0.5%FSS (Full-Scale Span) when measuring inductances from 1 mH to 10 mH, and from 10 mH to 100 mH.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The development of load-bearing osseous implant with desired mechanical and surface properties in order to promote incorporation with bone and to eliminate risk of bone resorption and implant failure is a very challenging task. Bone formation and resoption processes depend on the mechanical environment. Certain stress/strain conditions are required to promote new bone growth and to prevent bone mass loss. Conventional metallic implants with high stiffness carry most of the load and the surrounding bone becomes virtually unloaded and inactive. Fibre-reinforced composites offer an interesting alternative to metallic implants, because their mechanical properties can be tailored to be equal to those of bone, by the careful selection of matrix polymer, type of fibres, fibre volume fraction, orientation and length. Successful load transfer at bone-implant interface requires proper fixation between the bone and implant. One promising method to promote fixation is to prepare implants with porous surface. Bone ingrowth into porous surface structure stabilises the system and improves clinical success of the implant. The experimental part of this work was focused on polymethyl methacrylate (PMMA) -based composites with dense load-bearing core and porous surface. Three-dimensionally randomly orientated chopped glass fibres were used to reinforce the composite. A method to fabricate those composites was developed by a solvent treatment technique and some characterisations concerning the functionality of the surface structure were made in vitro and in vivo. Scanning electron microscope observations revealed that the pore size and interconnective porous architecture of the surface layer of the fibre-reinforced composite (FRC) could be optimal for bone ingrowth. Microhardness measurements showed that the solvent treatment did not have an effect on the mechanical properties of the load-bearing core. A push-out test, using dental stone as a bone model material, revealed that short glass fibre-reinforced porous surface layer is strong enough to carry load. Unreacted monomers can cause the chemical necrosis of the tissue, but the levels of leachable resisidual monomers were considerably lower than those found in chemically cured fibre-reinforced dentures and in modified acrylic bone cements. Animal experiments proved that surface porous FRC implant can enhance fixation between bone and FRC. New bone ingrowth into the pores was detected and strong interlocking between bone and the implant was achieved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this project is to accomplish an application software based on Matlab to calculate the radioelectrical coverage by surface wave of broadcast radiostations in the band of Medium Wave (WM) all around the world. Also, given the location of a transmitting and a receiving station, the software should be able to calculate the electric field that the receiver should receive at that specific site. In case of several transmitters, the program should search for the existence of Inter-Symbol Interference, and calculate the field strenght accordingly. The application should ask for the configuration parameters of the transmitter radiostation within a Graphical User Interface (GUI), and bring back the resulting coverage above a map of the area under study. For the development of this project, it has been used several conductivity databases of different countries, and a high-resolution elevation database (GLOBE). Also, to calculate the field strenght due to groundwave propagation, it has been used ITU GRWAVE program, which must be integrated into a Matlab interface to be used by the application developed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

L’Slot, conegut per tots amb el nom d’Scalextric, s’ha implantat com a una forma d’oci habitual, la pràctica del qual no queda restringida als més petits, sinó que cada vegada crea més afició entre els grans. El fet que l’Slot s’hagi extès entre els adults n’ha revolucionat la pràctica. L’entrada al mercat de l’Slot de gent adulta, i amb poder adquisitiu molt superior als adolescents, ha provocat que les marques especialitzades vagin evolucionant els seus productes cada vegada més. Totes les marques s’han vist obligades a desenvolupar vehicles més competitius i alhora treure al mercat accessoris que augmentin la realitat del joc. Una de les necessitats que s’ha creat és la de competir entre jugadors. Aquesta competició tan pot ser en forma de carrera entre diversos participants, com de forma individual, cronometrant el temps de cada participant en un circuit. L’objectiu principal del projecte és crear un sistema capaç de realitzar cronometratges en temps real mitjançant sensors digitals ja existents en el mercat de l’Slot i poder controlar i visualitzar la informació des d’un PC. Per a poder captar els senyals dels sensors s’ha utilitzat un sistema microcontrolat, que garanteix gran velocitat d’adquisició, processament de dades i transmissió. La comunicació del Microcontrolador amb el PC s’ha realizat mitjançant el bus USB. El PC serà el controlador del sistema i donarà les ordres al Microcontrolador, podent així tenir control total sobre el funcionament del programa. També serà el PC el que tractarà els crocometratges enregistrats i els mostrarà per pantalla

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An analytical method for the determination of the anti-inflammatory drug 5-aminosalicylic acid (5-ASA) in pharmaceutical formulations using square wave voltammetry at pencil graphite electrodes was developed. After the optimization of the experimental conditions, calibration curves were obtained in the linear concentration range from 9.78 × 10-7 to 7.25 × 10-5 mol L-1 resulting in a limit of detection of 2.12 ± 0.05 x 10-8 mol L-1. Statistical tests showed that the concentrations of 5-ASA in commercial tablets and enemas obtained with the proposed voltammetric method agreed with HPLC values at a 95% confidence level.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple procedure is described for the determination of scopolamine by square-wave voltammetry using a cathodically pretreated boron-doped diamond electrode. Cyclic voltammetry studies indicate that the oxidation of scopolamine is irreversible at a peak potential of 1.59 V (vs. Ag/AgCl (3.0 mol L-1 KCl)) in a 0.50 mol L-1 sulfuric acid solution. Under optimized conditions, the analytical curve obtained was linear (r = 0.9996) for the scopolamine concentration range of 1.0 to 110 µmol L-1, with a detection limit of 0.84 µmol L-1. The method was successfully applied to the determination of scopolamine in pharmaceutical formulations with minimum sample preparation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work is directed to the study and evaluation of gas diffusion electrodes as detectors in hydrogen sensors. Electrochemical experiments were carried out with rotating disk electrodes with a thin porous coating of the catalyst as a previous step to select useful parameters for the sensor. An experimental arrangement made in the laboratory that simulates the sensor was found appropriate to detect volumetric hydrogen percentages above 0.25% in mixtures H2:N2. The system shows a linear response for volumetric percentages of hydrogen between 0.25 and 2 %.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work presents an electroanalytical method for the determination of moxifloxacin (MOXI) in tablets by its interaction with Cu(II) ion and subsequent electrochemical reduction at hanging mercury drop electrode (HMDE). A well-defined reduction peak at -0.21 V vs. Ag/AgCl in Phosphate buffer 0.04 mol L-1 pH 8.0 was observed for the complex reduction MOXI-Cu(II), using square-wave voltammetry (SWV). Using a 10 s of accumulation time at -0.40 V was found a limit detection of 3.60x10-8 mol l-1. The obtained results have shown good agreement with those obtained by spectrophotometric method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In order to a better characterization of a graphite-polyurethane composite intended to be used as a voltammetric sensor, the performance in a square wave voltammetric procedure was investigated. Using hydroquinone (HQ) as a probe, the electrode showed to be useful in square wave voltammetry with limit of detection of 0.28 µmol L-1, with recoveries between 99.1 and 101.5%. The results of the proposed method agreed with HPLC ones within 95% confidence level.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cutting of thick section stainless steel and mild steel, and medium section aluminium using the high power ytterbium fibre laser has been experimentally investigated in this study. Theoretical models of the laser power requirement for cutting of a metal workpiece and the melt removal rate were also developed. The calculated laser power requirement was correlated to the laser power used for the cutting of 10 mm stainless steel workpiece and 15 mm mild steel workpiece using the ytterbium fibre laser and the CO2 laser. Nitrogen assist gas was used for cutting of stainless steel and oxygen was used for mild steel cutting. It was found that the incident laser power required for cutting at a given cutting speed was lower for fibre laser cutting than for CO2 laser cutting indicating a higher absorptivity of the fibre laser beam by the workpiece and higher melting efficiency for the fibre laser beam than for the CO2 laser beam. The difficulty in achieving an efficient melt removal during high speed cutting of the 15 mmmild steel workpiece with oxygen assist gas using the ytterbium fibre laser can be attributed to the high melting efficiency of the ytterbium fibre laser. The calculated melt flow velocity and melt film thickness correlated well with the location of the boundary layer separation point on the 10 mm stainless steel cut edges. An increase in the melt film thickness caused by deceleration of the melt particles in the boundary layer by the viscous shear forces results in the flow separation. The melt flow velocity increases with an increase in assist gas pressure and cut kerf width resulting in a reduction in the melt film thickness and the boundary layer separation point moves closer to the bottom cut edge. The cut edge quality was examined by visual inspection of the cut samples and measurement of the cut kerf width, boundary layer separation point, cut edge squareness (perpendicularity) deviation, and cut edge surface roughness as output quality factors. Different regions of cut edge quality in 10 mm stainless steel and 4 mm aluminium workpieces were defined for different combinations of cutting speed and laserpower.Optimization of processing parameters for a high cut edge quality in 10 mmstainless steel was demonstrated

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the work eddy current sensors are described and evaluated. Theoretical part includes physical basics of the eddy currents, overview of available commercial products and technologies. Industrial sensors operation was assessed based on several working modes. Apart from this, the model was created in Matlab Simulink with Xilinx Blockset and then translated into a Xilinx ISE Design Suite compatible project. The performance of the resulting implementation was compared to the existing implementation in the Xilinx Spartan 3 FPGA board with the custom made sensor. Additionally, an introduction to FPGAs and VHDL is presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

As vigas estruturais de madeira são formas racionais do emprego da madeira na construção de estruturas, sendo obtidas pela associação de peças serradas e permitindo a utilização de tábuas com seções e comprimentos variados, além de combinações com madeira de qualidade diferenciada. Para atingir a resistência máxima de uma viga de madeira laminada colada, pode-se utilizar a classificação mecânica das peças por meio dinâmico. O objetivo deste estudo foi estabelecer correlação entre os métodos estático e dinâmico de classificação de vigas de madeira laminada. O trabalho foi desenvolvido com o emprego de peças de madeira serrada de Pinus taeda e adesivo resorcina fenolformaldeído. O processo de fabricação das vigas envolveu a classificação das peças, usinagem de emendas, formação das lamelas, montagem e prensagem das vigas. Já os ensaios envolveram a determinação do módulo de elasticidade por meio do ''stress wave method'' e de uma máquina universal de ensaios. Os resultados foram analisados pela análise de regressão do estabelecimento da equação de ajuste de correlação. O sistema de classificação visual utilizado na seleção de peças foi insuficiente para se atingirem os valores máximos de módulo de elasticidade; o posicionamento correto das lamelas por meio do método dinâmico de classificação teve como consequência direta o aumento do módulo de elasticidade da viga, e houve baixa correlação entre as formas de obtenção do módulo de elasticidade das vigas, não sendo possível a elaboração de equação adequada entre os métodos testados.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Foram avaliadas as propriedades físicas e mecânicas de compósitos LVL produzidos com a madeira de paricá (Schizolobium amazonicum Huber ex. Ducke), por meio de Stress Wave Timer. Os compósitos foram confeccionados em laboratório, dos quais foram retiradas amostras, que foram inicialmente destinadas à realização dos ensaios não destrutivos. Todas as amostras, com dimensões de 2,2 × 2,2 × 40 cm, foram ensaiadas, não destrutivamente, com a propagação de ondas nos sentidos flatwise e edgewise. Em sequência, as mesmas amostras foram destinadas à confecção de subamostras, para realização dos ensaios destrutivos, físicos (absorção de água, inchamento em espessura e inchamento residual) e mecânicos (resistência e rigidez à flexão estática flatwise; resistência e rigidez à flexão estática edgewise; resistência à compressão paralela e resistência ao cisalhamento paralelo e perpendicular). A velocidade de propagação das ondas (V0) e o módulo de elasticidade dinâmico (Emd), obtidos com o auxílio do Stress Wave, foram utilizados para elaboração de modelos de predição das propriedades avaliadas. Os resultados indicaram que o Stress Wave Timer apresenta resultados satisfatórios para predição das propriedades mecânicas de compósitos LVL. Com relação às propriedades físicas, embora tenham sido verificados modelos com ajustes significativos, constatou-se limitação dessa ferramenta para predição desses parâmetros. Contudo, considerando ambas as propriedades, físicas e mecânicas, os melhores ajustes foram observados em amostras ensaiadas com a propagação de ondas no sentido edgewise e com o uso da variável independente Emd.