999 resultados para Aproveitamento da água pluvial


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple and inexpensive device to automate a water distilling apparatus is shown. It is composed by a magnetic floater placed in the water reservoir and a level control unit, which acts over the heating element circuit. In order to provide water saving, an electromagnetic valve is inserted in the water supply inlet. Some suggestions for the adaptation to other types of equipment are also offered.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Solid-phase microextraction (SPME) has been applied to direct extraction of 11 organophosphorus pesticides in water using a 100 mm fiber polydimethylsiloxane. The method was evaluated with respect time of exposure, detection limits (LODs), linearity and precision. The detection limits (S/N = 3) depend of each pesticide and varie about ng/L levels. The linearity was satisfactory with coefficients of correlation usually greater than 0.993. The precision of the method was determined by extraction from 4.0 mg/L aqueous standard with coefficients of variation between 5.7 to 17.2%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Selenium is both essential and toxic to man and animals, depending on the concentration and the ingested form. Most fruits and vegetables are poor sources of selenium, but coconut can be a good selenium source. Samples were suspended (1 + 4 v/v) in a mixture of tertiary amines soluble in water (10% v/v CFA-C). This simple sample treatment avoided contamination and decreased the analysis time. The standard additions method was adopted for quantification. The action of the autosampler was improved by the presence of the amines mixture in the suspension. A Varian model AA-800 atomic absorption spectrometer equipped with a graphite furnace and a GTA 100 autosampler was used for selenium determination in coconut water and coconut milk. Background correction was performed by means of the Zeeman effect. Pyrolytically coated graphite tubes were employed. Using Pd as chemical modifier, the pyrolysis and the atomization temperatures were set at 1400 and 2200ºC, respectively. For six samples, the selenium concentration in coconut water varied from 6.5 to 21.0 mug L-1 and in coconut milk from 24.2 to 25.1 mug L-1. The accuracy of the proposed method was evaluated by an addition-recovery experiment and all recovered values are in the 99.5-102.3% range. The main advantage of the proposed method is that it can be directly applied without sample decomposition.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Water Quality Index (WQI) was used during summer and winter of 1994 and 1995 in the final section of Onça and Feijão streams, downstream Broa Reservoir (São Carlos/SP) to evaluate agricultural and catlleman effects. In Onça stream water quality was "acceptable" in winter and "inappropriate to conventional treatment" in the summer. In Feijão stream the water had an "excellent" quality in winter and "good" in the summer. A MANOVA (Multivariate Analysis of Variance) has used to discriminate seasons and streams. Correlation (p<0,05) among the variables was tested. Water temperature, turbidity, pH and fecal bacteria are highly correlated and can be one of the factors that cause WQI change by seasons.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The pyrethroids bifenthrin, permethrin, cypermethrin and deltamethrin were extracted by solid phase extraction (SPE) and solid phase microextraction (SPME). The analysis were performed on a gas chromatograph with electron capture detection (GC-ECD). Octadecil Silano-C18, Florisil and Silica stationary phases were studied for SPE. Better results were obtained for Florisil which gave recoveries from 80% to 108%. Pyrethroids extraction by SPME showed a linear response and a detection limit of 10 pg ml-1. Although the data showed that the two extraction methods were able to isolate the pesticide residues from water samples, the best results were obtained by using SPME which is more sensitive, faster, cheeper, being a more useful technique for the analysis of pyrethroids in drinking water.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The analysis of water samples containing volatile organic compounds has become an important task in analytical chemistry. Gas chromatography has been widely used for the analysis of volatile organic compounds in water. The headspace analysis shows as a principal characteristic the possibility of determination of the volatile components in drinking water. Benzene, Toluene and Xylene (BTX) are important compounds usually present in drinking water, from contamination by petroleum derivatives. Since they are toxic compounds even when present in low concentration levels, their determination is important in order to define the quality of the water. The sampling technique using headspace, coupled with gas chromatography as the separation method, showed to be suitable for BTX analysis in several samples at the mug/L (ppb) level.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Simultaneous electrolytic deposition is proposed for minimization of Cu2+ and Pb2+ interferences on automated determination of Cd2+ by the Malachite Green-iodide reaction. During electrolysis of sample in a cell with two Pt electrodes and a medium adjusted to 5% (v/v) HNO3 + 0.1% (v/v) H2SO4 + 0.5 mol L-1 NaCl, Cu2+ is deposited as Cu on the cathode, Pb2+ is deposited as PbO2 on the anode while Cd2+ is kept in solution. With 60 s electrolysis time and 0.25 A current, Pb2+ and Cu2+ levels up to 50 and 250 mg L-1 respectively, can be tolerated without interference. With on-line extraction of Cd2+ in anionic resin minicolumn, calibration graph in the 5.00 - 50.0 µg Cd L-1 range is obtained, corresponding to twenty measurements per hour, 0.7 mg Malachite Green and 500 mg KI and 5 mL sample consumed per determination. Results of the determination of Cd in certified reference materials, vegetables and tap water were in agreement with certified values and with those obtained by GFAAS at 95% confidence level. The detection limit is 0.23 µg Cd L-1 and the RSD for typical samples containing 13.0 µg Cd L-1 was 3.85 % (n= 12).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Values of repeatability (r) and reproducibility (R) are parameters of an analytical method. They are related to the maximum difference between two results of analysis (permissible range) and can be obtained by interlaboratorial comparisons. They represent great importance for the quality control of the results and decisions about the fitness-for-purpose of the method. Water determination in fuel oil samples were performed by 16 laboratories, using the Karl Fischer reaction, during the period from June 1997 to December 1999. Values of r and R were presented. Discussion is made in terms of the main factors that would be contribution to analytical method variabilities and uncertainties of final results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coal ashes produced in coal-fired power plant could be converted into zeolites and can be used as low-cost adsorbents for the treatment of effluents contaminated with high levels of toxic metals. The capacity of synthetic zeolites for the removal of cadmium, zinc and copper ions from aqueous solutions has been investigated under different operating conditions. Zeolite from bottom chimney showed higher removal efficiency for metals ions than zeolite from feed hopper and mixing mill. The results indicated that the treated bottom ash could be applied in environmental technology as an immobilizer of pollutants.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A model based on chemical structure was developed for the accurate prediction of octanol/water partition coefficient (K OW) of polychlorinated biphenyls (PCBs), which are molecules of environmental interest. Partial least squares (PLS) was used to build the regression model. Topological indices were used as molecular descriptors. Variable selection was performed by Hierarchical Cluster Analysis (HCA). In the modeling process, the experimental K OW measured for 30 PCBs by thin-layer chromatography - retention time (TLC-RT) has been used. The developed model (Q² = 0,990 and r² = 0,994) was used to estimate the log K OW values for the 179 PCB congeners whose K OW data have not yet been measured by TLC-RT method. The results showed that topological indices can be very useful to predict the K OW.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this study the factors that affect the extraction of pesticide residues from water samples for their determination by solid-phase micro-extraction (SPME) and GC/MS were optimized. The fiber polymer, the extraction mode, the ionic strength, the stirring rate, the pH and the extraction time were the most significant parameters evaluated. The recovery obtained with the proposed method ranged from 94 to 110% and the sensitivity of the method, determined by calculating the detection limit (DL), ranged from 0.004 to 0.1 mug l-1. The results obtained with spiked real samples, at the 0.1 mug l-1 level, showed acceptable conformity with the expected values.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper evaluates the presence of organochlorinated pesticides in the water supply system of the city of Bauru, State of São Paulo, Brazil. Soil samples were collected in agricultural areas and water samples at several points of the water source (river) and the distribution net. The results of the analyses of the water from the source were compared with the Brazilian classification system for inland waters (CONAMA/86) and the results of analyses of treated water were compared with Brazilian standards for finished drinking water.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work presents an alternative method for determination of the herbicides tebuthiuron and hexazinone in ground water. The extraction was made with dichloromethane and the analyses by high performance liquid chromatography (HPLC), using reversed-phase column, C-18, mobile phase methanol/water 50:50, v/v, detection and quantification at 247 nm. The following validation parameters were obtained: limit of detection of method 0.02 and 0.03 µg L-1, limit of quantification of method 0.07 and 0.09 µg L-1; linear range limit of quantification of instrument - 300 µg L-1 (r² > 0.998); recoveries from 90.3 to 108.2% and 90.3 to 101.6%; intermediary precision (%RSD) < 8 and < 6%, for hexazinone and tebuthiuron, respectively. The method showed to be efficient and reliable for determination of the herbicides in ground water.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The identification and characterization of the hydrochemistry of the groundwaters has been done for seven wells. The sampling occurred during three bimonthly campaigns. The results classified the waters as of the calcium bicarbonated type for the majority of the samples, except for one well, whose composition is of the sodium bicarbonated type. The major ions found and how they determine the quality parameters are consistent with the reactions of mineral dissolution of the majority of volcanic rocks and the reactions with intrusion of alkaline rock in only one well. Anomalous values of nitrate in some wells alert to the impact of especially polluting sources at the time the reservoirs of the hydroeletric plant were formed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

El estudio se ha llevado a cabo de acuerdo con el Contrato de prestación de serviciosfirmado entre la Fundación ONCE y la Fundació Bosch i Gimpera (Universidadde Barcelona) con fecha 23 de julio de 2012. Este Contrato se enmarca en el ProgramaOperativo de “Lucha contra la Discriminación 2007-2013”, cofinanciado por elFondo Social Europeo (FSE).