971 resultados para Air Services Network
Resumo:
Mestrado em Engenharia Electrotécnica e de Computadores
Resumo:
The Bologna Process aimed to build a European Higher Education Area promoting student's mobility. The adoption of Bologna Declaration directives requires a self management distributed approach to deal with student's mobility, allowing frequent updates in institutions rules or legislation. This paper suggests a computational system architecture, which follows a social network design. A set of structured annotations is proposed in order to organize the user's information. For instance, when the user is a student its annotations are organized into an academic record. The academic record data is used to discover interests, namely mobility interests, among students that belongs the academic network. These ideas have been applied into a demonstrator that includes a mobility simulator to compare and show the student's academic evolution.
Resumo:
Mestrado em Engenharia Electrotécnica e de Computadores
Resumo:
This paper presents the foundations of an Academic Social Network (ASN) focusing the Bologna Declaration and the Bologna Process (BP) mobility issues using ontological support. An ASN will permit students to share commons academic interests, preferences and mobility paths in the European Higher Education Space (EHES). The description of the conceptual support is ontology based allowing knowledge sharing and reuse. An approach is presented by merging Academic Ontology to Support the Bologna Mobility Process with Friend of a Friend ontology. The resulting ontology supports the student mobility profile in the ASN. The strategies to make available, in the network, knowledge about mobility issues, are presented including knowledge discovery and simulation approaches to cover student's mobility scenarios for BP.
Resumo:
This study evaluates the dosimetric impact caused by an air cavity located at 2 mm depth from the top surface in a PMMA phantom irradiated by electron beams produced by a Siemens Primus linear accelerator. A systematic evaluation of the effect related to the cavity area and thickness as well as to the electron beam energy was performed by using Monte Carlo simulations (EGSnrc code), Pencil Beam algorithm and Gafchromic EBT2 films. A home-PMMA phantom with the same geometry as the simulated one was specifically constructed for the measurements. Our results indicate that the presence of the cavity causes an increase (up to 70%) of the dose maximum value as well as a shift forward of the position of the depthedose curve, compared to the homogeneous one. Pronounced dose discontinuities in the regions close to the lateral cavity edges are observed. The shape and magnitude of these discontinuities change with the dimension of the cavity. It is also found that the cavity effect is more pronounced (6%) for the 12 MeV electron beam and the presence of cavities with large thickness and small area introduces more significant variations (up to 70%) on the depthedose curves. Overall, the Gafchromic EBT2 film measurements were found in agreement within 3% with Monte Carlo calculations and predict well the fine details of the dosimetric change near the cavity interface. The Pencil Beam calculations underestimate the dose up to 40% compared to Monte Carlo simulations; in particular for the largest cavity thickness (2.8 cm).
Resumo:
Throughout the world, epidemiological studies were established to examine the relationship between air pollution and mortality rates and adverse respiratory health effects. However, despite the years of discussion the correlation between adverse health effects and atmospheric pollution remains controversial, partly because these studies are frequently restricted to small and well-monitored areas. Monitoring air pollution is complex due to the large spatial and temporal variations of pollution phenomena, the high costs of recording instruments, and the low sampling density of a purely instrumental approach. Therefore, together with the traditional instrumental monitoring, bioindication techniques allow for the mapping of pollution effects over wide areas with a high sampling density. In this study, instrumental and biomonitoring techniques were integrated to support an epidemiological study that will be developed in an industrial area located in Gijon in the coastal of central Asturias, Spain. Three main objectives were proposed to (i) analyze temporal patterns of PM10 concentrations in order to apportion emissions sources, (ii) investigate spatial patterns of lichen conductivity to identify the impact of the studied industrial area in air quality, and (iii) establish relationships amongst lichen conductivity with some site-specific characteristics. Samples of the epiphytic lichen Parmelia sulcata were transplanted in a grid of 18 by 20 km with an industrial area in the center. Lichens were exposed for a 5-mo period starting in April 2010. After exposure, lichen samples were soaked in 18-MΩ water aimed at determination of water electrical conductivity and, consequently, lichen vitality and cell damage. A marked decreasing gradient of lichens conductivity relative to distance from the emitting sources was observed. Transplants from a sampling site proximal to the industrial area reached values 10-fold higher than levels far from it. This finding showed that lichens reacted physiologically in the polluted industrial area as evidenced by increased conductivity correlated to contamination level. The integration of temporal PM10 measurements and analysis of wind direction corroborated the importance of this industrialized region for air quality measurements and identified the relevance of traffic for the urban area.
Resumo:
This paper is part of the results from the project "Implementation Strategies and Development of an Open and Distance Education System for the University of the Azores" funded by the European Social Fund. http://hdl.handle.net/10400.3/2327
Resumo:
Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Mecânica com especialização em Energia, Climatização e Refrigeração
Resumo:
OBJECTIVE: To evaluate knowledge, attitude and practice related to mammography among women users of local health services, identifying barriers to its performance. METHODS: A total of 663 women were interviewed at 13 local health centers in a city of Southeastern Brazil, in 2001. Interviewees were randomly selected at each center and they were representative from different socioeconomic conditions. The number of interviewees at each center was proportional to monthly mean appointments. For data analysis, answers were described as knowledge, attitude, practice and their respective adequacies and then they were correlated with control variables through the chi-square test. RESULTS: Only 7.4% of the interviewees had adequate knowledge on mammography, while 97.1% of women had an adequate attitude. The same was seen for the practice of mammography that was adequate in 35.7% of the cases. The main barrier to mammography was lack of referral by physicians working at the health center (81.8%). There was an association between adequacy of attitude and five years or more of education and being married. There was also an association between adequacy of mammography practice and being employed and family income up to four minimum wages. CONCLUSIONS: Women users of local health services had no adequate knowledge and practice related to mammography despite having an adequate attitude about this exam.
Resumo:
Mestrado em Engenharia Química. Ramo Tecnologias de Protecção Ambiental.
Resumo:
Dissertação de Mestrado em Ciências Económicas e Empresariais.
Resumo:
O presente trabalho insere-se no âmbito do Mestrado de Engenharia Química, ramo Optimização Energética na Indústria Química e pretende-se efectuar a avaliação energética do Complexo Municipal de Piscinas de Folgosa, localizado no Concelho da Maia, tendo como principais bases os Decretos-Lei 78, 79 e 80 de 04 de Abril 2006. Uma vez que a área útil de pavimento do presente edifício é superior a 1000 m2, encontra-se englobado no conceito de Grande Edifício de Serviços (GES). A escolha do Complexo Municipal de Piscinas de Folgosa para a realização do presente estudo prendeu-se com o facto de ser um objectivo da Câmara Municipal, mais concretamente do Departamento de Conservação e Manutenção de Estruturas Municipais, dar inicio aos procedimentos necessários para a certificação energética dos diversos edifícios Municipais, aliado ao facto das piscinas serem um tipo de edifício desportivo de elevada complexidade em termos de gestão, um grande consumidor de energia e possuidor de uma elevada diversidade de equipamentos. O objectivo principal será o de caracterizar energeticamente o edifício e optimizar os consumos do mesmo, de forma a reduzir, não só os consumos energéticos e respectiva factura, mas também nas emissões dos gases de efeito de estufa (CO2), pelo que a ordem de trabalhos inclui a realização de: - Avaliação Energética de acordo com o n.º1 do artigo 2º e artigo 34º do D. L. 79/2006; - Verificação dos Requisitos de Condução e manutenção das instalações de Aquecimento, Ventilação e Ar Condicionado (AVAC); - Caracterização Energética do Edifício – Índice de Eficiência Energética. A metodologia seguida baseou-se na utilizada para a realização de uma auditoria energética, sendo que foram contempladas as seguintes etapas: estudo pormenorizado da legislação referente à certificação de edifícios; realização de um levantamento de consumos energéticos reais da instalação (com base nas facturas energéticas); das suas características funcionais e levantamento dos vários equipamentos consumidores de energia. O Complexo Municipal de Piscinas de Folgosa é uma instalação cuja média de consumo de energia eléctrica nos últimos três anos foi de 445969 kWh/ano e de 87300 m3 de gás natural, representando um consumo global de energia primária de 174,85 tep/ano. De acordo com o Sistema de Certificação Energética o Índice de Eficiência Energética determinado é de 54,50 kgep/m2 .ano. Uma vez que o IEE determinado é superior ao valor de IEEReferência existentes, o edifício estará obrigado ao cumprimento de um Plano de Racionalização Energética (PRE). É apresentado um conjunto de medidas que visam uma redução do consumo de energia do edifício e consequentemente uma melhoria no Índice de Eficiência Energética.
Resumo:
Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia de Electrónica e Telecomunicações
Resumo:
Este trabalho surgiu no âmbito da Tese de Mestrado em Engenharia Química - Ramo Optimização Energética na Indústria Química, aliando a necessidade da Empresa Monteiro Ribas – Indústrias, S.A. em resolver alguns problemas relacionados com as estufas da unidade J da fábrica de revestimentos. Outro dos objectivos era propor melhorias de eficiência energética neste sector da empresa. Para tal, foi necessário fazer um levantamento energético de toda a unidade, o que permitiu verificar que as estufas de secagem (Recobrimento 1 e 2) seriam o principal objecto de estudo. O levantamento energético da empresa permitiu conhecer o seu consumo anual de energia de 697,9 tep, o que a classifica, segundo o Decreto-lei nº 71 de 15 de Abril de 2008, como Consumidora Intensiva de Energia (CIE). Além disso, as situações que devem ser alvo de melhoria são: a rede de termofluido, que apresenta válvulas sem isolamento, o sistema de iluminação, que não é o mais eficiente e a rede de distribuição de ar comprimido, que não tem a estrutura mais adequada. Desta forma sugere-se que a rede de distribuição de termofluido passe a ter válvulas isoladas com lã de rocha, o investimento total é de 2.481,56 €, mas a poupança pode ser de 21.145,14 €/ano, com o período de retorno de 0,12 anos. No sistema de iluminação propõe-se a substituição dos balastros normais por electrónicos, o investimento total é de 13.873,74 €, mas a poupança é de 2.620,26 €/ano, com período de retorno de 5 anos. No processo de secagem das linhas de recobrimento mediram-se temperaturas de todos os seus componentes, velocidades de ar o que permitiu conhecer a distribuição do calor fornecido pelo termofluido. No Recobrimento 1, o ar recebe entre 39 a 51% do calor total, a tela recebe cerca de 25% e na terceira estufa este é apenas de 6%. Nesta linha as perdas de calor por radiação oscilam entre 6 e 11% enquanto as perdas por convecção representam cerca de 17 a 44%. Como o calor que a tela recebe é muito inferior ao calor recebido pelo ar no Recobrimento 1, propõe-se uma redução do caudal de ar que entra na estufa, o que conduzirá certamente à poupança de energia térmica. No Recobrimento 2 o calor fornecido ao ar representa cerca de 51 a 77% do calor total e o cedido à tela oscila entre 2 e 3%. As perdas de calor por convecção oscilam entre 12 e 26%, enquanto que as perdas por radiação têm valores entre 4 e 8%. No que diz respeito ao calor necessário para evaporar os solventes este oscila entre os 4 e 13%. Os balanços de massa e energia realizados ao processo de secagem permitiram ainda determinar o rendimento das 3 estufas do Recobrimento 1, com 36, 47 e 24% paras as estufa 1, 2 e 3, respectivamente. No Recobrimento 2 os valores de rendimento foram superiores, tendo-se obtido valores próximos dos 41, 81 e 88%, para as estufas 1, 2 e 3, respectivamente. Face aos resultados obtidos propõem-se a reengenharia do processo introduzindo permutadores compactos para aquecer o ar antes de este entrar nas estufas. O estudo desta alteração foi apenas realizado para a estufa 1 do Recobrimento 1, tendo-se obtido uma área de transferência de calor de 6,80 m2, um investimento associado de 8.867,81 €. e uma poupança de 708,88 €/ano, com um período de retorno do investimento de 13 anos. Outra sugestão consiste na recirculação de parte do ar de saída (5%), que conduz à poupança de 158,02 €/ano. Estes valores, pouco significativos, não estimulam a adopção das referidas sugestões.
Resumo:
Dissertação de natureza científica realizada para obtenção do grau de Mestre em Engenharia de Redes de Computadores e Multimédia