992 resultados para pulsed laser deposition
Resumo:
Objectives: A study was made to determine the temperature increment at the dental root surface following Er,Cr:YSGG laser irradiation of the root canal. Design. Human canines and incisors previously instrumented to K file number ISO 30 were used. Irradiation was carried out with glass fiber endodontic tips measuring 200 μm in diameter and especially designed for insertion in the root canal. The teeth were irradiated at 1 and 2 W for 30 seconds, without water spraying or air, and applying a continuous circular movement (approximately 2 mm/sec.) in the apico-coronal direction. Results: At the 1 W power setting, the mean temperature increment was 3.84ºC versus 5.01ºC at 2 W. In all cases the difference in mean value obtained after irradiation versus the mean baseline temperature proved statistically significant (p< 0.05). Conclusions: Application of the Er,Cr:YSGG laser gives rise to a statistically significant temperature increment at the external root surface, though this increment is probably clinically irrelevant, since it would appear to damage the tissues (periodontal ligament and alveolar bone) in proximity to the treated tooth
Resumo:
Tässä työssä raportoidaan hybridihitsauksesta otettujen suurnopeuskuvasarjojen automaattisen analyysijärjestelmän kehittäminen.Järjestelmän tarkoitus oli tuottaa tietoa, joka avustaisi analysoijaa arvioimaan kuvatun hitsausprosessin laatua. Tutkimus keskittyi valokaaren taajuuden säännöllisyyden ja lisäainepisaroiden lentosuuntien mittaamiseen. Valokaaria havaittiin kuvasarjoista sumean c-means-klusterointimenetelmän avullaja perättäisten valokaarien välistä aikaväliä käytettiin valokaaren taajuuden säännöllisyyden mittarina. Pisaroita paikannettiin menetelmällä, jossa yhdistyi pääkomponenttianalyysi ja tukivektoriluokitin. Kalman-suodinta käytettiin tuottamaan arvioita pisaroiden lentosuunnista ja nopeuksista. Lentosuunnanmääritysmenetelmä luokitteli pisarat niiden arvioitujen lentosuuntien perusteella. Järjestelmän kehittämiseen käytettävissä olleet kuvasarjat poikkesivat merkittävästi toisistaan kuvanlaadun ja pisaroiden ulkomuodon osalta, johtuen eroista kuvaus- ja hitsausprosesseissa. Analyysijärjestelmä kehitettiin toimimaan pienellä osajoukolla kuvasarjoja, joissa oli tietynlainen kuvaus- ja hitsausprosessi ja joiden kuvanlaatu ja pisaroiden ulkomuoto olivat samankaltaisia, mutta järjestelmää testattiin myös osajoukon ulkopuolisilla kuvasarjoilla. Testitulokset osoittivat, että lentosuunnanmääritystarkkuus oli kohtuullisen suuri osajoukonsisällä ja pieni muissa kuvasarjoissa. Valokaaren taajuuden säännöllisyyden määritys oli tarkka useammassa kuvasarjassa.
Resumo:
BACKGROUND: Both nutritional and genetic factors are involved in the pathogenesis of nonalcoholic fatty liver disease and insulin resistance. OBJECTIVE: The aim was to assess the effects of fructose, a potent stimulator of hepatic de novo lipogenesis, on intrahepatocellular lipids (IHCLs) and insulin sensitivity in healthy offspring of patients with type 2 diabetes (OffT2D)--a subgroup of individuals prone to metabolic disorders. DESIGN: Sixteen male OffT2D and 8 control subjects were studied in a crossover design after either a 7-d isocaloric diet or a hypercaloric high-fructose diet (3.5 g x kg FFM(-1) x d(-1), +35% energy intake). Hepatic and whole-body insulin sensitivity were assessed with a 2-step hyperinsulinemic euglycemic clamp (0.3 and 1.0 mU x kg(-1) x min(-1)), together with 6,6-[2H2]glucose. IHCLs and intramyocellular lipids (IMCLs) were measured by 1H-magnetic resonance spectroscopy. RESULTS: The OffT2D group had significantly (P < 0.05) higher IHCLs (+94%), total triacylglycerols (+35%), and lower whole-body insulin sensitivity (-27%) than did the control group. The high-fructose diet significantly increased IHCLs (control: +76%; OffT2D: +79%), IMCLs (control: +47%; OffT2D: +24%), VLDL-triacylglycerols (control: +51%; OffT2D: +110%), and fasting hepatic glucose output (control: +4%; OffT2D: +5%). Furthermore, the effects of fructose on VLDL-triacylglycerols were higher in the OffT2D group (group x diet interaction: P < 0.05). CONCLUSIONS: A 7-d high-fructose diet increased ectopic lipid deposition in liver and muscle and fasting VLDL-triacylglycerols and decreased hepatic insulin sensitivity. Fructose-induced alterations in VLDL-triacylglycerols appeared to be of greater magnitude in the OffT2D group, which suggests that these individuals may be more prone to developing dyslipidemia when challenged by high fructose intakes. This trial was registered at clinicaltrials.gov as NCT00523562.
Resumo:
Fiber laser for materials processing have undergone a rapid development in the pastseveral years. As fiber laser provides a combination of high beam quality and awavelength that is easily absorbed by metal surfaces, the named future laser isexpected to challenge the CO2 and Nd:YAG lasers in the area of metal cutting. This thesis studied the performance of fiber laser cutting mild steel. In the literature review part, it introduced the laser cutting principle and the principle of fiber laser including the newest development of fiber laser cuttingtechnology. Because the fiber laser cutting mild steel is a very young technology, a preliminary test was made in order to investigate effect of the cutting parameters on cut quality. Then the formal fiber laser cutting experiment was madeby using 3 mm thickness S355 steel with oxygen as assistant gas. The experimentwas focused on the cut quality with maximum cutting speed and minimum oxygen gas pressure. And the cut quality is mainly decided by the kerf width, perpendicularity tolerance, surface roughness and striation patterns. After analysis the cutting result, several conclusions were made. Although the best result got in the experiment is not perfect as predicted, the whole result of the test can be accepted. Compared with CO2 laser, a higher cutting speed was achieved by fiber laser with very low oxygen gas pressure. A further improvement about the cutting quality might be possible by proper selection of process parameters. And in order to investigate the cutting performance more clearly, a future study about cutting different thickness mild steel and different shape was recommended.
Resumo:
Steep mountain catchments typically experience large sediment pulses from hillslopes which are stored in headwater channels and remobilized by debris-flows or bedload transport. Event-based sediment budget monitoring in the active Manival debris-flow torrent in the French Alps during a two-year period gave insights into the catchment-scale sediment routing during moderate rainfall intensities which occur several times each year. The monitoring was based on intensive topographic resurveys of low- and high-order channels using different techniques (cross-section surveys with total station and high-resolution channel surveys with terrestrial and airborne laser scanning). Data on sediment output volumes from the main channel were obtained by a sediment trap. Two debris-flows were observed, as well as several bedload transport flow events. Sediment budget analysis of the two debris-flows revealed that most of the debris-flow volumes were supplied by channel scouring (more than 92%). Bedload transport during autumn contributed to the sediment recharge of high-order channels by the deposition of large gravel wedges. This process is recognized as being fundamental for debris-flow occurrence during the subsequent spring and summer. A time shift of scour-and-fill sequences was observed between low- and high-order channels, revealing the discontinuous sediment transfer in the catchment during common flow events. A conceptual model of sediment routing for different event magnitude is proposed.
Resumo:
This research has been focused at the development of a tuned systematic design methodology, which gives the best performance in a computer aided environment and utilises a cross-technological approach, specially tested with and for laser processed microwave mechanics. A tuned design process scheme is also presented. Because of the currently large production volumes of microwave and radio frequency mechanics even slight improvements of design methodologies or manufacturing technologies would give reasonable possibilities for cost reduction. The typical number of required iteration cycles could be reduced to one fifth of normal. The research area dealing with the methodologies is divided firstly into a function-oriented, a performance-oriented or a manufacturability-oriented product design. Alternatively various approaches can be developed for a customer-oriented, a quality-oriented, a cost-oriented or an organisation-oriented design. However, the real need for improvements is between these two extremes. This means that the effective methodology for the designers should not be too limited (like in the performance-oriented design) or too general (like in the organisation-oriented design), but it should, include the context of the design environment. This is the area where the current research is focused. To test the developed tuned design methodology for laser processing (TDMLP) and the tuned optimising algorithm for laser processing (TOLP), seven different industrial product applications for microwave mechanics have been designed, CAD-modelled and manufactured by using laser in small production series. To verify that the performance of these products meets the required level and to ensure the objectiveness ofthe results extensive laboratory tests were used for all designed prototypes. As an example a Ku-band horn antenna can be laser processed from steel in 2 minutes at the same time obtaining a comparable electrical performance of classical aluminium units or the residual resistance of a laser joint in steel could be limited to 72 milliohmia.
Resumo:
This paper describes a mesurement system designed to register the displacement of the legs using a two-dimensional laser range sensor with a scanning plane parallel to the ground and extract gait parameters. In the proposed methodology, the position of the legs is estimated by fitting two circles with the laser points that define their contour and the gait parameters are extracted applying a step-line model to the estimated displacement of the legs to reduce uncertainty in the determination of the stand and swing phase of the gait. Results obtained in a range up to 8 m shows that the systematic error in the location of one static leg is lower than 10 mm with and standard deviation lower than 8 mm; this deviation increases to 11 mm in the case of a moving leg. The proposed measurement system has been applied to estimate the gait parameters of six volunteers in a preliminary walking experiment.
Resumo:
The optimization of most pesticide and fertilizer applications is based on overall grove conditions. In this work we measurements. Recently, Wei [9, 10] used a terrestrial propose a measurement system based on a ground laser scanner to LIDAR to measure tree height, width and volume developing estimate the volume of the trees and then extrapolate their foliage a set of experiments to evaluate the repeatability and surface in real-time. Tests with pear trees demonstrated that the accuracy of the measurements, obtaining a coefficient of relation between the volume and the foliage can be interpreted as variation of 5.4% and a relative error of 4.4% in the linear with a coefficient of correlation (R) of 0.81 and the foliar estimation of the volume but without real-time capabilities. surface can be estimated with an average error less than 5 %.
Resumo:
Background: Proliferative retinopathy is an important cause of vision loss in diabetic patients. Incomplete panretinal photocoagulation (PRP) can lead to recurrent proliferation of new vessels. Patients and Methods: We retrospectively analysed the outcome of patients with high risk proliferative diabetic retinopathy (PDR) previously treated with slit lamp PRP who underwent indirect fill in argon laser treatment with scleral indentation under anesthesia for persistent neovascular proliferation. Results: Seventeen eyes of ten patients were included. The mean age at diabetes onset was 17.3 years SD 16.2 (range 2-44). All patients reported long standing poor glycemic control (mean HbA1c: 8.5 % SD 1.3 range 5.9-10.2). The area of retinal ischemia decreased significantly from 15 ± 7.5 disk areas (DA) before fill-in laser to 3.2 ± 4.2 DA after fill-in laser (p = 0.001). The new vessels also regressed significantly after laser treatment 8.6 ± 6.1 DA before treatment versus 6.5 ± 6.4 DA after laser treatment, (p = 0.044). Quiescent PDR was reached in 10 eyes (58.8 %) at the last visit. Conclusions: Fill-in indirect argon laser under general anesthesia should be considered to achieve further new vessels regression in high risk PDR patients. Scleral indentation and absence of pain may allow for more extensive laser application.
Resumo:
ZnO nanorods grown by both high temperature vapour phase transport and low temperature chemical bath deposition are very promising sources for UV third harmonic generation. Material grown by both methods show comparable efficiencies, in both cases an order of magnitude higher than surface third harmonic generation at the quartz-air interface of a bare quartz substrate. This result is in stark contrast to the linear optical properties of ZnO nanorods grown by these two methods, which show vastly different PL efficiencies. The third harmonic generated signal is analysed using intensity dependent measurements and interferometric frequency resolved optical gating, allowing extraction of the laser pulse parameters. The comparable levels of efficiency of ZnO grown by these very different methods as sources for third harmonic UV generation provides a broad suite of possible growth methods to suit various substrates, coverage and scalability requirements. Potential application areas range from interferometric frequency resolved optical gating characterization of few cycle fs pulses to single cell UV irradiation for biophysical studies.
Resumo:
Diplomityön tavoitteena oli selvittää tandem-MAG-hitsausmenetelmän soveltuvuus isojen levylakanoiden valmistamiseen. Päätavoitteena oli selvittää suurimmat saavutettavat hitsausnopeudet sekä railonvalmistukselle asetettavat vaatimukset kahdella laivanrakennusteräksellä. Tutkimuksessa käytettiin omia hitsauskokeita ja liitokset testattiin luokitusseurojen vaatimusten mukaisesti. Selvitettiin myös syntyvät hitsausmuodonmuutokset sekä edut ja rajoitukset verrattuna laserhitsaukseen. Lisäksi laadittiin ei-synergiselle pulssihitsauslaitteistolle suuntaa-antava synergiakäyrä tätä sovellusta varten hitsauskokeiden perusteella. Tandem-MAG-hitsaus osoittautui erittäin kilpailukykyiseksi hitsausmenetelmäksi sovelluksessa. Magneettisen puhalluksen havaittiin olevan merkittävä häiriötekijä tällä menetelmällä hitsattaessa.
APP processing and b-amyloid deposition in sporadic Creutzfeldt-Jakob patients is dependent on Dab1.
Resumo:
Alzheimer"s disease and prion pathologies (e.g., Creutzfeldt-Jakob disease (CJD)) display profound neural lesions associated with aberrant protein processing and extracellular amyloid deposits. Dab1 has been implicated in the regulation of Amyloid Precursor Protein (APP), but a direct link between human prion diseases and Dab1/APP interactions has not been published. Here we examined this putative relationship in seventeen cases of sporadic CJD (sCJD) post mortem. Biochemical analyses of brain tissue revealed two groups, which also correlated with PrPsc types 1 and 2. One group, with PrPsc type 1 showed increased Dab1 phosphorylation, and lower CTF production with an absence of A deposition. The second sCJD group, which carried PrPsc type 2, showed lower levels of Dab1 phosphorylation and CTF production, and A deposition. Thus, the present observations suggest a correlation between Dab1-phosphorylation, A deposition and PrPsc type in sCJD.
Resumo:
Raaka-aineen hiukkaskoko on lääkekehityksessä keskeinen materiaaliparametri. Lääkeaineen partikkelikoko vaikuttaa moneen lääketuotteen tärkeään ominaisuuteen, esimerkiksi lääkkeen biologiseen hyväksikäytettävyyteen. Tässä diplomityössä keskityttiin jauhemaisten lääkeaineiden hiukkaskoon määrittämiseen laserdiffraktiomenetelmällä. Menetelmä perustuu siihen, että partikkeleista sironneen valon intensiteetin sirontakulmajakauma on riippuvainen partikkelien kokojakaumasta. Työn kirjallisuusosassa esiteltiin laserdiffraktiomenetelmän teoriaa. PIDS (Polarization Intensity Differential Scattering) tekniikka, jota voidaan käyttää laserdiffraktion yhteydessä, on myös kuvattu kirjallisuusosassa. Muihin menetelmiin perustuvista analyysimenetelmistä tutustuttiin mikroskopiaan sekä aerodynaamisen lentoajan määrittämiseen perustuvaan menetelmään. Kirjallisuusosassa esiteltiin myös partikkelikoon yleisimpiä esitystapoja. Työn kokeellisen osan tarkoituksena oli kehittää ja validoida laserdiffraktioon perustuva partikkelikoon määritysmenetelmä tietylle lääkeaineelle. Menetelmäkehitys tehtiin käyttäen Beckman Coulter LS 13 320 laserdiffraktoria. Laite mahdollistaa PIDS-tekniikan käytön laserdiffraktiotekniikan ohella. Menetelmäkehitys aloitettiin arvioimalla, että kyseinen lääkeaine soveltuu parhaiten määritettäväksi nesteeseen dispergoituna. Liukoisuuden perusteella väliaineeksi valittiin tällä lääkeaineella kyllästetty vesiliuos. Dispergointiaineen sekä ultraäänihauteen käyttö havaittiin tarpeelliseksi dispergoidessa kyseistä lääkeainetta kylläiseen vesiliuokseen. Lopuksi sekoitusnopeus näytteensyöttöyksikössä säädettiin sopivaksi. Validointivaiheessa kehitetyn menetelmän todettiin soveltuvan hyvin kyseiselle lääkeaineelle ja tulosten todettiin olevan oikeellisia sekä toistettavia. Menetelmä ei myöskään ollut herkkä pienille häiriöille.