947 resultados para mHealth Salute Mobile HealthCare Strategia Aziendale
Resumo:
In this letter, a multiantenna system with four printed monopoles is presented. The monopoles that occupy relatively small area are positioned at the four corners of a printed circuit board, so that the four-element antenna system can be equipped on the lid of a folder-type mobile phone, leaving enough space for the circuits and reducing the effect of human hands. Based on simulation, a prototype for the Universal Mobile Telecommunications System (UMTS) operation has been constructed and tested. The measured -10-dB impedance bandwidths of the four elements are larger than 320 MHz with higher than 11.5-dB isolation. Moreover, the proposed antenna can provide spatial and pattern diversity in a diversity/multiple-input-multiple-output (MIMO) system.
Resumo:
To cope with the rapid growth of multimedia applications that requires dynamic levels of quality of service (QoS), cross-layer (CL) design, where multiple protocol layers are jointly combined, has been considered to provide diverse QoS provisions for mobile multimedia networks. However, there is a lack of a general mathematical framework to model such CL scheme in wireless networks with different types of multimedia classes. In this paper, to overcome this shortcoming, we therefore propose a novel CL design for integrated real-time/non-real-time traffic with strict preemptive priority via a finite-state Markov chain. The main strategy of the CL scheme is to design a Markov model by explicitly including adaptive modulation and coding at the physical layer, queuing at the data link layer, and the bursty nature of multimedia traffic classes at the application layer. Utilizing this Markov model, several important performance metrics in terms of packet loss rate, delay, and throughput are examined. In addition, our proposed framework is exploited in various multimedia applications, for example, the end-to-end real-time video streaming and CL optimization, which require the priority-based QoS adaptation for different applications. More importantly, the CL framework reveals important guidelines as to optimize the network performance
Energy-Aware Rate and Description Allocation Optimized Video Streaming for Mobile D2D Communications
Resumo:
The proliferation problem of video streaming applications and mobile devices has prompted wireless network operators to put more efforts into improving quality of experience (QoE) while saving resources that are needed for high transmission rate and large size of video streaming. To deal with this problem, we propose an energy-aware rate and description allocation optimization method for video streaming in cellular network assisted device-to-device (D2D) communications. In particular, we allocate the optimal bit rate to each layer of video segments and packetize the segments into multiple descriptions with embedded forward error correction (FEC) for realtime streaming without retransmission. Simultaneously, the optimal number of descriptions is allocated to each D2D helper for transmission. The two allocation processes are done according to the access rate of segments, channel state information (CSI) of D2D requester, and remaining energy of helpers, to gain the highest optimization performance. Simulation results demonstrate that our proposed method (named OPT) significantly enhances the performance of video streaming in terms of high QoE and energy saving.
Resumo:
BACKGROUND: Ethical issues are increasingly being reported by care-providers; however, little is known about the nature of these issues within the nursing home. Ethical issues are unavoidable in healthcare and can result in opportunities for improving work and care conditions; however, they are also associated with detrimental outcomes including staff burnout and moral distress.
OBJECTIVES: The purpose of this review was to identify prior research which focuses on ethical issues in the nursing home and to explore staffs' experiences of ethical issues.
METHODS: Using a systematic approach based on Aveyard (2014), a literature review was conducted which focused on ethical and moral issues, nurses and nursing assistants, and the nursing home.
FINDINGS: The most salient themes identified in the review included clashing ethical principles, issues related to communication, lack of resources and quality of care provision. The review also identified solutions for overcoming the ethical issues that were identified and revealed the definitional challenges that permeate this area of work.
CONCLUSIONS: The review highlighted a need for improved ethics education for care-providers.
Resumo:
This special issue provides the latest research and development on wireless mobile wearable communications. According to a report by Juniper Research, the market value of connected wearable devices is expected to reach $1.5 billion by 2014, and the shipment of wearable devices may reach 70 million by 2017. Good examples of wearable devices are the prominent Google Glass and Microsoft HoloLens. As wearable technology is rapidly penetrating our daily life, mobile wearable communication is becoming a new communication paradigm. Mobile wearable device communications create new challenges compared to ordinary sensor networks and short-range communication. In mobile wearable communications, devices communicate with each other in a peer-to-peer fashion or client-server fashion and also communicate with aggregation points (e.g., smartphones, tablets, and gateway nodes). Wearable devices are expected to integrate multiple radio technologies for various applications' needs with small power consumption and low transmission delays. These devices can hence collect, interpret, transmit, and exchange data among supporting components, other wearable devices, and the Internet. Such data are not limited to people's personal biomedical information but also include human-centric social and contextual data. The success of mobile wearable technology depends on communication and networking architectures that support efficient and secure end-to-end information flows. A key design consideration of future wearable devices is the ability to ubiquitously connect to smartphones or the Internet with very low energy consumption. Radio propagation and, accordingly, channel models are also different from those in other existing wireless technologies. A huge number of connected wearable devices require novel big data processing algorithms, efficient storage solutions, cloud-assisted infrastructures, and spectrum-efficient communications technologies.
Resumo:
A resazurin (Rz) based photocatalyst activity indicator ink (paii) is used to test the activity of commercial self-cleaning materials. The semiconductor photocatalyst driven colour change of the ink is monitored indoors and outside using a simple mobile phone application that measures the RGB colour components of the digital image of the paii-covered, irradiated sample in real time. The results correlate directly with those generated using a traditional, lab-bound method of analysis (UV–vis spectrophotometry).
Resumo:
The objective of this study was to evaluate the impact of restricting high-risk antibiotics on methicillin-resistant Staphylococcus aureus (MRSA) incidence rates in a hospital setting. A secondary objective was to assess the impact of reducing fluoroquinolone use in the primary-care setting on MRSA incidence in the community. This was an interventional, retrospective, ecological investigation in both hospital and community (January 2006 to June 2010). Segmented regression analysis of interrupted time-series was employed to evaluate the intervention. The restriction of high-risk antibiotics was associated with a significant change in hospital MRSA incidence trend (coefficient=-0·00561, P=0·0057). Analysis showed that the intervention relating to reducing fluoroquinolone use in the community was associated with a significant trend change in MRSA incidence in community (coefficient=-0·00004, P=0·0299). The reduction in high-risk antibiotic use and fluoroquinolone use contributed to both a reduction in incidence rates of MRSA in hospital and community (primary-care) settings.
Resumo:
Objectives: To determine whether adjusting the denominator of the common hospital antibiotic use measurement unit (defined daily doses/100 bed-days) by including age-adjusted comorbidity score (100 bed-days/age-adjusted comorbidity score) would result in more accurate and meaningful assessment of hospital antibiotic use.
Methods: The association between the monthly sum of age-adjusted comorbidity and monthly antibiotic use was measured using time-series analysis (January 2008 to June 2012). For the purposes of conducting internal benchmarking, two antibiotic usage datasets were constructed, i.e. 2004-07 (first study period) and 2008-11 (second study period). Monthly antibiotic use was normalized per 100 bed-days and per 100 bed-days/age-adjusted comorbidity score.
Results: Results showed that antibiotic use had significant positive relationships with the sum of age-adjusted comorbidity score (P = 0.0004). The results also showed that there was a negative relationship between antibiotic use and (i) alcohol-based hand rub use (P = 0.0370) and (ii) clinical pharmacist activity (P = 0.0031). Normalizing antibiotic use per 100 bed-days contributed to a comparative usage rate of 1.31, i.e. the average antibiotic use during the second period was 31% higher than during the first period. However, normalizing antibiotic use per 100 bed-days per age-adjusted comorbidity score resulted in a comparative usage rate of 0.98, i.e. the average antibiotic use was 2% lower in the second study period. Importantly, the latter comparative usage rate is independent of differences in patient density and case mix characteristics between the two studied populations.
Conclusions: The proposed modified antibiotic measure provides an innovative approach to compare variations in antibiotic prescribing while taking account of patient case mix effects.