841 resultados para implementation of organizational values


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The experiments observe and measure the length of the annular regime in fully condensing quasi-steady (steady-in-the-mean) flows of pure FC-72 vapor in a horizontal condenser (rectangular cross-section of 2 mm height, 15 mm width, and 1 m length). The sides and top of the duct are made of clear plastic that allows flow visualization. The experimental system in which this condenser is used is able to control and achieve different quasi-steady mass flow rates, inlet pressures, and wall cooling conditions (by adjustment of the temperature and flow rate of the cooling water flowing underneath the condensing-plate). The reported correlations and measurements for the annular length are also vital information for determining the length of the annular regime and proposing extended correlation (covering many vapors and a larger parameter set than the experimentally reported version here) by ongoing independent modeling and computational simulation approach.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Determining how an exhaust system will perform acoustically before a prototype muffler is built can save the designer both a substantial amount of time and resources. In order to effectively use the simulation tools available it is important to understand what is the most effective tool for the intended purpose of analysis as well as how typical elements in an exhaust system affect muffler performance. An in-depth look at the available tools and their most beneficial uses are presented in this thesis. A full parametric study was conducted using the FEM method for typical muffler elements which was also correlated to experimental results. This thesis lays out the overall ground work on how to accurately predict sound pressure levels in the free field for an exhaust system with the engine properties included. The accuracy of the model is heavily dependent on the correct temperature profile of the model in addition to the accuracy of the source properties. These factors will be discussed in detail and methods for determining them will be presented. The secondary effects of mean flow, which affects both the acoustical wave propagation and the flow noise generation, will be discussed. Effective ways for predicting these secondary effects will be described. Experimental models will be tested on a flow rig that showcases these phenomena.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Ever since the invention of the internal combustion engine, generating more power and achieving better efficiency has been a major goal for the designers. Variable compression ratio technology is way to achieve those goals. This paper will discuss the method of varying the compression ratio of an inline 4-cylinder engine through the use of a 4-bar linkage and gear mechanism. This mechanism was proven to easily vary the compression ratio of the engine and shows promise of becoming a technology used for future engine designer.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

KIVA is a FORTRAN code developed by Los Alamos national lab to simulate complete engine cycle. KIVA is a flow solver code which is used to perform calculation of properties in a fluid flow field. It involves using various numerical schemes and methods to solve the Navier-Stokes equation. This project involves improving the accuracy of one such scheme by upgrading it to a higher order scheme. The numerical scheme to be modified is used in the critical final stage calculation called as rezoning phase. The primitive objective of this project is to implement a higher order numerical scheme, to validate and verify that the new scheme is better than the existing scheme. The latest version of the KIVA family (KIVA 4) is used for implementing the higher order scheme to support handling the unstructured mesh. The code is validated using the traditional shock tube problem and the results are verified to be more accurate than the existing schemes in reference with the analytical result. The convection test is performed to compare the computational accuracy on convective transfer; it is found that the new scheme has less numerical diffusion compared to the existing schemes. A four valve pentroof engine, an example case of KIVA package is used as application to ensure the stability of the scheme in practical application. The results are compared for the temperature profile. In spite of all the positive results, the numerical scheme implemented has a downside of consuming more CPU time for the computational analysis. The detailed comparison is provided. However, in an overview, the implementation of the higher order scheme in the latest code KIVA 4 is verified to be successful and it gives better results than the existing scheme which satisfies the objective of this project.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The current climate of increasing performance expectations and diminishing resources, along with innovations in evidence-based practices (EBPs), creates new dilemmas for substance abuse treatment providers, policymakers, funders, and the service delivery system. This paper describes findings from baseline interviews with representatives from 49 state substance abuse authorities (SSAs). Interviews assessed efforts aimed at facilitating EBP adoption in each state and the District of Columbia. Results suggested that SSAs are concentrating more effort on EBP implementation strategies such as education, training, and infrastructure development, and less effort on financial mechanisms, regulations, and accreditation. The majority of SSAs use EBPs as a criterion in their contracts with providers, and just over half reported that EBP use is tied to state funding. To date, Oregon remains the only state with legislation that mandates treatment expenditures for EBPs; North Carolina follows suit with legislation that requires EBP promotion within current resources.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Implementation of effective substance abuse treatment programs in community settings is a high priority. The selection of a proven cost-effective model is a first step; however, difficulty arises when the model is imported into a community setting. The Center on Substance Abuse Treatment selected a brief substance abuse treatment program for adolescents, the MET/CBT-5 program, determined to be the most cost-effective protocol in the Cannabis Youth Treatment trial, for implementation in two cohorts of Effective Adolescent Treatment grantees. A qualitative investigation of the protocol implementation with nine sites in the second cohort chronicled adaptations made by grantees and prospects for sustainability. The study found that agencies introduced adaptations without seeming to be aware of potential effects on validity. In most sites, sessions were lengthened or added to accommodate individual client needs, address barriers to client participation, and provide consistency with current norms of treatment. Implications for fidelity of future implementation projects are addressed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The widespread of low cost embedded electronics makes it easier to implement the smart devices that can understand either the environment or the user behaviors. The main object of this project is to design and implement home use portable smart electronics, including the portable monitoring device for home and office security and the portable 3D mouse for convenient use. Both devices in this project use the MPU6050 which contains a 3 axis accelerometer and a 3 axis gyroscope to sense the inertial motion of the door or the human hands movement. For the portable monitoring device for home and office security, MPU6050 is used to sense the door (either home front door or cabinet door) movement through the gyroscope, and Raspberry Pi is then used to process the data it receives from MPU6050, if the data value exceeds the preset threshold, Raspberry Pi would control the USB Webcam to take a picture and then send out an alert email with the picture to the user. The advantage of this device is that it is a small size portable stand-alone device with its own power source, it is easy to implement, really cheap for residential use, and energy efficient with instantaneous alert. For the 3D mouse, the MPU6050 would use both the accelerometer and gyroscope to sense user hands movement, the data are processed by MSP430G2553 through a digital smooth filter and a complementary filter, and then the filtered data will pass to the personal computer through the serial COM port. By applying the cursor movement equation in the PC driver, this device can work great as a mouse with acceptable accuracy. Compared to the normal optical mouse we are using, this mouse does not need any working surface, with the use of the smooth and complementary filter, it has certain accuracy for normal use, and it is easy to be extended to a portable mouse as small as a finger ring.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

STUDY AIM: A pilot study was conducted to implement and evaluate a routine gradual psycho-diagnostic programme to improve diagnostics and treatment of mental disorders in somatic rehabilitation centres. First of all, implementation strategies were acquired in trainings together with psychologists and physicians. The psycho-diagnostic programme consists of a screening instrument (PHQ-9) designed to permit time-effective detection of comorbid mental disorders. Besides evaluation of the training, the aim of the study was to analyze the extent to which it is possible to implement the routine gradual psycho-diagnostic programme in practice. Additionally, it was intended to identify beneficial and obstructive conditions for implementation. METHODOLOGY: The pilot study was conducted in two orthopaedic and one cardiological rehabilitation centre. The training was evaluated directly after its completion using a questionnaire. Three months after its implementation, the introduction of the psycho-diagnostic programme was evaluated using interviews with n=11 physicians and psychologists. RESULTS: The training was rated positively by the participants . Implementation of the entire gradual psycho-diagnostic programme was possible in one centre and to some degree in the other two. Beneficial for implementation were a frank organisational climate, sufficient time resources, and physicians' biopsychosocial understanding of disease. A dismissive attitude towards psycho-diagnostics, little communication between staff members, little perceived advantage for one's own work and fear to stigmatise patients by psychiatric diagnoses were obstructive. CONCLUSION: Essential for a successful implementation are sufficient time and personal resources, a motivation for change in staff and centre management, and a positive attitude regarding psycho-diagnostics in clinic staff. Furthermore, flexibility in implementation strategies and the opportunity to participate in the implementation process are important.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To determine how the ADC value of parotid glands is influenced by the choice of b-values. MATERIALS AND METHODS: In eight healthy volunteers, diffusion-weighted echo-planar imaging (DW-EPI) was performed on a 1.5 T system, with b-values (in seconds/mm2) of 0, 50, 100, 150, 200, 250, 300, 500, 750, and 1000. ADC values were calculated by two alternative methods (exponential vs. logarithmic fit) from five different sets of b-values: (A) all b-values; (B) b=0, 50, and 100; (C) b=0 and 750; (D) b=0, 500, and 1000; and (E) b=500, 750, and 1000. RESULTS: The mean ADC values for the different settings were (in 10(-3) mm2/second, exponential fit): (A) 0.732+/-0.019, (B) 2.074+/-0.084, (C) 0.947+/-0.020, (D) 0.890+/-0.023, and (E) 0.581+/-0.021. ADC values were significantly (P <0.001) different for all pairwise comparisons of settings (A-E) of b-values, except for A vs. D (P=0.172) and C vs. D (P=0.380). The ADC(B) was significantly higher than ADC(C) or ADC(D), which was significantly higher than ADC(E). ADC values from exponential vs. logarithmic fit (P=0.542), as well as left vs. right parotid gland (P=0.962), were indistinguishable. CONCLUSION: The ADC values calculated from low b-value settings were significantly higher than those calculated from high b-value settings. These results suggest that not only true diffusion but also perfusion and saliva flow may contribute to the ADC.

Relevância:

100.00% 100.00%

Publicador: