Length of the annular regime for condensing flows inside a horizontal channel - the experimental determination of its values and its trends


Autoria(s): Gorgitrattanagul, Patcharapol
Data(s)

01/01/2011

Resumo

The experiments observe and measure the length of the annular regime in fully condensing quasi-steady (steady-in-the-mean) flows of pure FC-72 vapor in a horizontal condenser (rectangular cross-section of 2 mm height, 15 mm width, and 1 m length). The sides and top of the duct are made of clear plastic that allows flow visualization. The experimental system in which this condenser is used is able to control and achieve different quasi-steady mass flow rates, inlet pressures, and wall cooling conditions (by adjustment of the temperature and flow rate of the cooling water flowing underneath the condensing-plate). The reported correlations and measurements for the annular length are also vital information for determining the length of the annular regime and proposing extended correlation (covering many vapors and a larger parameter set than the experimentally reported version here) by ongoing independent modeling and computational simulation approach.

Formato

application/pdf

Identificador

http://digitalcommons.mtu.edu/etds/366

http://digitalcommons.mtu.edu/cgi/viewcontent.cgi?article=1365&context=etds

Publicador

Digital Commons @ Michigan Tech

Fonte

Dissertations, Master's Theses and Master's Reports - Open

Palavras-Chave #Engineering #Mechanical Engineering
Tipo

text