991 resultados para déficit de pressão de vapor


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Topics of research related to energy and environment have significantly grown in recent years, with the need of its own energy as hydrogen. More particularly, numerous researches have been focused on hydrogen as energy vector. The main portion of hydrogen is presently obtained by reforming of methane or light hydrocarbons (steam, oxy, dry or auto reforming). During the methane steam reforming process the formation of CO2 undesirable (the main contributor to the greenhouse effect) is observed. Thus, an oxide material (sorbent) can be used to capture the CO2 generated during the process and simultaneously shifting the equilibrium of water gas shift towards thermodynamically more favorable production of pure hydrogen. The aim of this study is to develop a material with dual function (catalyst/sorbent) in the reaction of steam reforming of methane. CaO is well known as CO2 sorbent due to its high efficiency in reactions of carbonation and easy regeneration through calcination. However the kinetic of carbonation decreases quickly with time and carbonation/calcination cycles. A calcium aluminate (Ca12Al14O33) should be used to avoid sintering and increase the stability of CaO sorbents for several cycles. Nickel, the industrial catalyst choice for steam reforming has been added to the support from different manners. These bi-functional materials (sorbent/catalyst) in different molar ratios CaO.Ca12Al14O33 (48:52, 65:35, 75:25, 90:10) were prepared by different synthesis methodologies, among them, especially the method of microwave assisted self-combustion. Synthesis, structure and catalytic performances of Ni- CaO.Ca12Al14O33 synthesized by the novel method (microwave assisted selfcombustion) proposed in this work has not being reported yet in literature. The results indicate that CO2 capture time depends both on the CaO excess and on operating conditions (eg., temperature and H2O/CH4 ratio). To be efficient for CO2 sorption, temperature of steam reforming needs to be lower than 700 °C. An optimized percentage corresponding to 75% of CaO and a ratio H2O/CH4 = 1 provides the most promising results since a smaller amount of water avoids competition between water and CO2 to form carbonate and hydroxide. If this competition is most effective (H2O/CH4 = 3) and would have a smaller amount of CaO available for absorption possibly due to the formation of Ca(OH)2. Therefore, the capture time was higher (16h) for the ratio H2O/CH4 = 1 than H2O/CH4 = 3 (7h) using as catalyst one prepared by impregnating the support obtained by microwave assisted self-combustion. Therefore, it was demonstrated that, with these catalysts, the CO2 sorption on CaO modifies the balance of the water gas-shift reaction. Consequently, steam reforming of CH4 is optimized, producing pure H2, complete conversion of methane and negligible concentration of CO2 and CO during the time of capture even at low temperature (650 °C). This validates the concept of the sorption of CO2 together with methane steam reforming

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVO: Caracterizar e comparar as funções motoras fina, sensorial e perceptiva de escolares com Transtorno do Déficit de Atenção com Hiperatividade (TDAH) e escolares com bom desempenho escolar sem alterações de comportamento. MÉTODOS: Participaram 22 escolares do ensino fundamental, de gênero masculino, distribuídos em: GI - 11 escolares com Transtorno do Déficit de Atenção com Hiperatividade; e GII - 11 escolares com bom desempenho acadêmico e sem alterações de comportamento. Os escolares foram submetidos à aplicação do Protocolo de Avaliação da Função Motora Fina, Sensorial e Perceptiva e da Escala de Disgrafia. RESULTADOS: Houve diferença nas tarefas de função motora fina, função sensorial e função perceptiva entre o GI e o GII, com desempenho inferior do GI. Todos os escolares de GI apresentaram disgrafia. CONCLUSÃO: Escolares com Transtorno do Déficit de Atenção com Hiperatividade apresentam desempenho inferior aos escolares com bom desempenho acadêmico em relação às funções motoras fina, sensorial e perceptiva. Tais dificuldades podem causar impacto significativo sobre o desempenho acadêmico, uma vez que comprometem o desenvolvimento da linguagem escrita, ocasionando disgrafia nesses escolares.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

JUSTIFICATIVA E OBJETIVOS: Estudos introduziram novo método para avaliação da pré-carga, baseado na análise da variação da pressão sistólica (VPS) durante ventilação artificial. O objetivo desta pesquisa é avaliar se a VPS e sua derivada delta down (ddown) são indicadoras precoces de hipovolemia e guias de reposição volêmica com solução hiperosmótica e hiperoncótica. MÉTODO: Doze cães foram submetidos a sangramentos parciais de 5% da volemia até se atingir 20% da volemia (14 ml.kg-1). Antes (controle) e após cada sangramento foram realizadas análises hemodinâmicas, respiratórias e sangüíneas. Após, os cães foram submetidos à reposição com solução de NaCl a 7,5% em dextran 70 a 3,75% (SHD) (4 ml.kg-1) e novas análises dos atributos estudados foram realizadas aos 5 e 30 minutos após a reposição. RESULTADOS: A pressão arterial média diminuiu durante o sangramento e aumentou após a reposição, sem retornar aos valores do controle. As pressões da artéria pulmonar e do átrio direito (PAD) diminuíram antes e aumentaram após a reposição para valores semelhantes aos do controle. A pressão da artéria pulmonar ocluída (PAPO) diminuiu após o primeiro sangramento e manteve-se em valores abaixo aos do controle, mesmo após a reposição. O índice cardíaco não se alterou, mas aumentou após a reposição, para valores superiores aos do controle. O índice sistólico (IS) diminuiu antes e aumentou após a reposição, em níveis superiores aos do controle. Os índices de resistência vascular sistêmica (IRVS) e pulmonar (IRVP) não se alteraram antes, mas diminuíram após a reposição, com o IRVS em níveis inferiores aos do controle, e o IRVP em níveis semelhantes aos do controle. Os índices de trabalho sistólico dos ventrículos direito (ITSVD) e esquerdo (ITSVE) diminuíram durante o sangramento, mas aumentaram após a reposição, com o ITSVD em níveis superiores aos do controle e o ITSVE em níveis semelhantes aos do controle. A VPS e ddown aumentaram progressivamente durante o sangramento e diminuíram após a reposição, mas mantendo-se em valores superiores aos do controle. As maiores correlações de VPS e ddown foram com IS, PAPO, PAD e ITSVE. CONCLUSÕES: No cão, nas condições empregadas, a VPS e sua derivada ddown são indicadoras precoces de hipovolemia e guias sensíveis de reposição volêmica com SHD.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

JUSTIFICATIVA E OBJETIVOS: As lesões da mucosa traqueal em contato com o balonete do tubo traqueal são proporcionais à pressão exercida pelo balonete e ao tempo de exposição. O objetivo foi estudar as eventuais lesões da mucosa do segmento traqueal em contato com o balonete do tubo traqueal insuflado com volume de ar suficiente para se obter pressão de "selo" ou com a pressão limite de 25 cmH2O, abaixo da pressão crítica de 30 cm de água para produção de lesão da mucosa traqueal. MÉTODO: Dezesseis cães foram submetidos à anestesia venosa e ventilação artificial. Os cães foram distribuídos aleatoriamente em dois grupos de acordo com a pressão no balonete do tubo traqueal (Portex Blue-Line, Inglaterra): Gselo (n = 8) balonete com pressão mínima de "selo" para impedir vazamento de ar durante a respiração artificial; G25 (n = 8) balonete insuflado até obtenção da pressão de 25 cmH2O. A medida da pressão do balonete foi realizada por meio de manômetro digital no início (controle) e após 60, 120 e 180 minutos. Após o sacrifício dos cães, foram feitas biópsias nas áreas da mucosa traqueal adjacentes ao balonete e ao tubo traqueal para análise à microscopia eletrônica de varredura (MEV). RESULTADOS: A pressão média do balonete em G25 manteve-se entre 24,8 e 25 cmH2O e em Gselo entre 11,9 e 12,5 cmH2O durante o experimento. As alterações à MEV foram pequenas e não significantemente diferentes nos grupos (p > 0,30), mas ocorreram lesões mais intensas nas áreas de contato da mucosa traqueal com o balonete do tubo traqueal, nos dois grupos, em relação às áreas da mucosa adjacentes ou não ao tubo traqueal (p < 0,05). CONCLUSÕES: No cão, nas condições experimentais empregadas, a insuflação do balonete de tubo traqueal em volume de ar suficiente para determinar pressão limite de 25 cmH2O ou de "selo" para impedir vazamento de ar determina lesões mínimas da mucosa traqueal em contato com o balonete e sem diferença significante entre elas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

JUSTIFICATIVA E OBJETIVOS: Não existem estudos que associem os efeitos determinados pelas modalidades ventilatórias às repercussões hemodinâmicas durante o pneumoperitônio. O objetivo deste estudo foi avaliar as alterações na hemodinâmica determinadas pelo pneumoperitônio em cães com ventilação por volume e pressão controlados. MÉTODO: Dezesseis cães anestesiados com tiopental sódico e fentanil foram divididos em grupo 1, volume controlado, e grupo 2, pressão controlada, e submetidos ao pneumoperitônio de 10 e 15 mmHg. Foram estudados freqüência cardíaca, pressão arterial média, pressão de átrio direito, pressão de artéria pulmonar ocluída, índice cardíaco, índice de resistência vascular sistêmica e vasopressina plasmática. Os dados foram coletados em 4 momentos. M1 - antes do pneumoperitônio, M2 - 30 minutos após pneumoperitônio com 10 mmHg, M3 - 30 minutos após pneumoperitônio com 15 mmHg, M4 - 30 minutos após a deflação do pneumoperitônio. RESULTADOS: Os resultados mostraram aumento no índice cardíaco, nas pressões de átrio direito e de artéria pulmonar ocluída em M2 e M3, em ambos os grupos. A vasopressina não variou durante o procedimento e o índice de resistência vascular sistêmica não aumentou, proporcionando estabilidade da pressão arterial média em ambos os grupos. CONCLUSÕES: As modalidades ventilatórias não determinaram diferenças na resposta hemodinâmica entre os grupos estudados. A técnica anestésica utilizada e as pressões intra-abdominais alcançadas determinaram estabilidade da pressão arterial média, provavelmente decorrente da ausência do aumento no índice da resistência vascular sistêmica.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In February 2011, the National Agency of Petroleum, Natural Gas and Biofuels (ANP) has published a new Technical Rules for Handling Land Pipeline Petroleum and Natural Gas Derivatives (RTDT). Among other things, the RTDT made compulsory the use of monitoring systems and leak detection in all onshore pipelines in the country. This document provides a study on the method for detection of transient pressure. The study was conducted on a industrial duct 16" diameter and 9.8 km long. The pipeline is fully pressurized and carries a multiphase mixture of crude oil, water and natural gas. For the study, was built an infrastructure for data acquisition and validation of detection algorithms. The system was designed with SCADA architecture. Piezoresistive sensors were installed at the ends of the duct and Digital Signal Processors (DSPs) were used for sampling, storage and processing of data. The study was based on simulations of leaks through valves and search for patterns that characterize the occurrence of such phenomena

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVO: analisar os valores da pressão arterial e da freqüência cardíaca durante o trabalho de parto e puerpério imediato de primigestas normais. MÉTODOS: foram incluídas no estudo 60 parturientes, às quais foi aplicada a monitorização ambulatorial da pressão arterial (MAPA) com uso do aparelho modelo SpaceLabs 90207, durante o trabalho de parto e nas primeiras 12 horas após o mesmo. A pressão arterial e a freqüência cardíaca foram registradas a cada 15 minutos durante o trabalho de parto e na primeira hora após o parto, e a cada 30 minutos até a 12ª hora após o parto. Esses parâmetros foram avaliados em três momentos do trabalho de parto (com dilatação cervical até 7 cm, entre 8 cm e dilatação total e durante o período expulsivo) e em dois momentos do puerpério (na primeira e décima segunda hora). Primeiramente os resultados foram analisados sem levar em consideração o tipo de procedimento anestésico, e depois, dividindo-os em grupos conforme o tipo de procedimento realizado: anestesia local, analgesia peridural lombar e anestesia subaracnóidea. Para comparação dentro de cada grupo foram realizados análise de variância (ANOVA) e teste t de Student pareado e, entre os grupos, o teste t não-pareado. Foi considerado o limite de significância estatística de 5%. RESULTADOS: quando os resultados foram avaliados sem levar em consideração o procedimento anestésico, os valores médios da pressão arterial sistólica, registrados durante o trabalho de parto, foram significativamente mais elevados que no puerpério. Durante o trabalho de parto esses valores foram significativamente mais elevados nos períodos de dilatação final e expulsivo que no período de dilatação inicial e, na 12ª hora, inferiores ao da primeira hora após o parto. Os valores médios da pressão arterial diastólica registrados durante o trabalho de parto foram significativamente mais altos que no puerpério. Estes valores não apresentaram alteração durante os diferentes períodos do trabalho de parto ou durante as primeiras doze horas do puerpério. A freqüência cardíaca aumentou progressivamente durante o trabalho de parto, diminuindo nas primeiras 12 horas após o parto. Quando a pressão arterial e a freqüência cardíaca foram avaliadas conforme o tipo de procedimento anestésico empregado, ambas mostraram-se com mesmo comportamento na anestesia local e peridural, embora naquelas submetidas à anestesia subaracnóidea, tanto a pressão arterial sistólica como a diastólica não apresentaram alteração durante o trabalho de parto. CONCLUSÕES: o trabalho de parto determinou aumento da pressão arterial sistólica e da freqüência cardíaca. Durante o trabalho de parto os valores das pressões arteriais sistólica e diastólica foram mais altos que nas primeiras 12 horas do puerpério, havendo queda significativa entre a primeira e a décima segunda hora do mesmo. Diferentes procedimentos anestésicos não interferiram nos valores das pressões arteriais sistólica e diastólica ou da freqüência cardíaca, durante o trabalho de parto e nas primeiras doze horas após o parto.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Estudou-se retrospectivamente a evolução clínica de dois pacientes, até sua falência cardíaca irreversível (FCI), submetidos à monitorização contínua da pressão intracraniana (PIC). O estudo detalhado desses traçados mostrou que, nos dois casos a PIC atingiu valores máximos 5 e 12 h antes de ocorrer diminuição na amplitude das ondas, observada 47 e 60 h pré-FCI. Essa diminução foi progressiva e tornou-se linear cerca de 30 h antes da FCI, em ambos os casos. O diagnóstico clínico de morte encefálica (ME) foi obtido 3 e 28 hs após a linearidade do traçado. Os autores sugerem que o diagnóstico de ME pode ser definido mais precocemente com o uso da monitorização da PIC desde que o paciente não esteja sob sedação, e salientam a necessidade de mais observações, em número maior de pacientes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUÇÃO: A pressão intra-ocular (Po) é o fator de risco isolado mais importante para o desenvolvimento do glaucoma primário de ângulo aberto (GPAA). O controle da Po é o objetivo principal da terapia antiglaucomatosa até o momento. A curva tensional diária (CTD) é de grande importância para o diagnóstico e seguimento do glaucoma primário de ângulo aberto. Métodos simplificados como a minicurva têm sido utilizados em seu lugar por serem mais práticos. OBJETIVO: Comparar curva tensional diária, minicurva e medida isolada às 6 horas quanto à detecção de picos pressóricos e verificar a influência da variação postural na medida das 6 horas da manhã. MÉTODOS: Sessenta e quatro pacientes (126 olhos) com glaucoma primário de ângulo aberto ou suspeita de glaucoma foram submetidos à curva tensional diária. A minicurva considerou as medidas das 9, 12, 15 e 18 horas da mesma curva tensional diária. A medida das 6 horas foi realizada no escuro, com o paciente deitado, utilizando o tonômetro de Perkins. Logo após, foi feita nova medida, com o paciente sentado, usando o tonômetro de Goldmann. A Po média e a ocorrência de picos (Po > 21 mmHg) da curva tensional diária e minicurva foram comparados, assim como o horário de ocorrência dos picos. RESULTADOS: A Po média foi maior no glaucoma primário de ângulo aberto do que nos suspeitos tanto na minicurva como na curva tensional diária Quando comparadas, a curva tensional diária apresentou médias de Po maiores que a minicurva. A medida das 6 horas foi maior quando feita com o paciente deitado. A minicurva não detectou 60,42% dos picos nos pacientes com glaucoma primário de ângulo aberto e 88,24% dos picos nos suspeitos. CONCLUSÃO: 1. A curva tensional diária detectou mais picos pressóricos do que a minicurva; 2. A média de Po das 6 horas foi maior com o paciente deitado; 3. A Po das 6 horas com o paciente deitado foi maior do que a Po média da curva tensional diária e da minicurva.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUÇÃO: O grupo das doenças cardiovasculares tem sido apontado como a principal causa de óbito no Brasil desde os anos 70, sendo a hipertensão arterial sistêmica (HAS) o fator de risco mais importante para esse grupo. Entre os trabalhadores observa-se correlação negativa entre o status ocupacional e a pressão arterial. Tais fatos ressaltam a importância do conhecimento da distribuição da pressão arterial sistêmica entre os distintos grupos profissionais. Assim, foi realizado estudo para descrever o status pressórico de uma população homogênea e estável de trabalhadores do setor secundário da economia, pouco especializados e que ganham baixos salários, estabelecendo a prevalência da HAS nesse grupo específico, relacionando-a com algumas covariáveis biológicas e socioeconômicas, e comparando-a com a prevalência de HAS em outros grupos profissionais no Brasil. MÉTODO: Foram estudados 73 trabalhadores regularmente empregados em julho de 1993 em um curtume situado no Município de Botucatu, cidade de médio porte da região Centro-Oeste do Estado de São Paulo, os quais foram submetidos a exame antropométrico, aferição de pressão arterial, anamnese e exame clínico. Os resultados foram comparados com os obtidos em estudos semelhantes, controlando-se o confundimento da idade por intermédio de diferentes técnicas. RESULTADOS: A prevalência bruta da HAS encontrada foi de 56,1%, sendo 15,8% a prevalência de hipertensão sistólica isolada. Ambas se associaram ao etilismo e ao tabagismo na população estudada. DISCUSSÃO: A prevalência da hipertensão foi consideravelmente alta e significativamente maior do que a encontrada em outros grupos de trabalhadores estudados no Brasil. Tal achado ressalta a necessidade da continuidade da investigação, objetivando o isolamento dos fatores implicados na elevação pressórica do grupo estudado.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pela técnica de regressão linear múltipla, estudou-se a relação existente entre pressão arterial diastólica e as variáveis tempo total acumulado de trabalho como condutor de veículos coletivos urbanos e idade, em uma população de 839 motoristas e cobradores, usuários de um serviço de saúde ocupacional da cidade de Campinas, Estado de São Paulo (Brasil). Os principais resultados encontrados foram associação positiva entre a pressão arterial diastólica e o tempo acumulado de trabalho, bem como existência de uma interação entre esta variável e a idade dos condutores.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Avaliaram-se as células endoteliais, a espessura corneana e a pressão intraocular (PIO) de cães portadores de catarata madura, empregando-se viscoelástico à base de hialuronato de sódio 3% e sulfato de condroitina 4% e hidroxipropilmetilcelulose 2%, utilizando-se 20 cães, distribuídos entre os dois grupos dos viscoelásticos. A técnica cirúrgica adotada foi a da facoemulsificação bimanual. As avaliações tonométricas foram efetuadas antes e após o ato cirúrgico, aos 1, 7, 14, 21, 28 e 60 dias de pós-operatório, e a microscopia especular, antes e após 7, 28 e 60 dias. Não houve diferença estatística entre os grupos quanto à PIO, com exceção aos 14 dias, em que se observou maior PIO com o uso de hialuronato de sódio 3% e sulfato de condroitina 4%. Não houve diferença entre os grupos quanto aos parâmetros relacionados ao endotélio, com diminuição discreta da densidade celular endotelial e aumento da área celular com a utilização de hidroxipropilmetilcelulose 2%. A utilização de ambos os dispositivos viscoelásticos analisados é recomendada para o procedimento de facoemulsificação em cães.