968 resultados para Zero current switching (ZCS) converters


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ruthenium dioxide is deposited on stainless steel (SS) substrate by galvanostatic oxidation of Ru3+. At high current densities employed for this purpose, there is oxidation of water to oxygen, which occurs in parallel with Ru3+ oxidation. The oxygen evolution consumes a major portion of the charge. The oxygen evolution generates a high porosity to RuO2 films, which is evident from scanning electron microscopy studies. RuO2 is identified by X-ray photoelectron spectroscopy. Cyclic voltammetry and galvanostatic charge–discharge cycling studies indicate that RuO2/SS electrodes possess good capacitance properties. Specific capacitance of 276 F g−1 is obtained at current densities as high as 20 mA cm−2 (13.33 A g−1). Porous nature of RuO2 facilitates passing of high currents during charge–discharge cycling. RuO2/SS electrodes are thus useful for high power supercapacitor applications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In 1974, the Russian physicist Vitaly Ginzburg wrote a book entitled `Key Problems of Physics and Astrophysics' in which he presented a selection of important and challenging problems along with speculations on what the future holds. The selection had a broad range, was highly personalized, and was aimed at the general scientist, for whom it made very interesting reading

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Though silicon tunnel field effect transistor (TFET) has attracted attention for sub-60 mV/decade subthreshold swing and very small OFF current (IOFF), its practical application is questionable due to low ON current (ION) and complicated fabrication process steps. In this paper, a new n-type classical-MOSFET-alike tunnel FET architecture is proposed, which offers sub-60 mV/decade subthreshold swing along with a significant improvement in ION. The enhancement in ION is achieved by introducing a thin strained SiGe layer on top of the silicon source. Through 2D simulations it is observed that the device is nearly free from short channel effect (SCE) and its immunity towards drain induced barrier lowering (DIBL) increases with increasing germanium mole fraction. It is also found that the body bias does not change the drive current but after body current gets affected. An ION of View the MathML source and a minimum average subthreshold swing of 13 mV/decade is achieved for 100 nm channel length device with 1.2 V supply voltage and 0.7 Ge mole fraction, while maintaining the IOFF in fA range.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Little is known about the neural mechanisms by which transcranial direct current stimulation (tDCS) impacts on language processing in post-stroke aphasia. This was addressed in a proof-of-principle study that explored the effects of tDCS application in aphasia during simultaneous functional magnetic resonance imaging (fMRI). We employed a single subject, cross-over, sham-tDCS controlled design, and the stimulation was administered to an individualized perilesional stimulation site that was identified by a baseline fMRI scan and a picture naming task. Peak activity during the baseline scan was located in the spared left inferior frontal gyrus and this area was stimulated during a subsequent cross-over phase. tDCS was successfully administered to the target region and anodal- vs. sham-tDCS resulted in selectively increased activity at the stimulation site. Our results thus demonstrate that it is feasible to precisely target an individualized stimulation site in aphasia patients during simultaneous fMRI, which allows assessing the neural mechanisms underlying tDCS application. The functional imaging results of this case report highlight one possible mechanism that may have contributed to beneficial behavioral stimulation effects in previous clinical tDCS trials in aphasia. In the future, this approach will allow identifying distinct patterns of stimulation effects on neural processing in larger cohorts of patients. This may ultimately yield information about the variability of tDCS effects on brain functions in aphasia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Investigations on the electrical switching behavior and thermal studies using Alternating Differential Scanning Calorimetry have been undertaken on bulk, melt-quenched Ge22Te78-,Is (3 <= x <= 10) chalcohalide glasses. All the glasses studied have been found to exhibit memory-type electrical switching. The threshold voltages of Ge22Te78-I-x(x) glasses have been found to increase with the addition of iodine and the composition dependence of threshold voltages of Ge22Te78-xIx glasses exhibits a cusp at 5 at.% of iodine. Also, the variation with composition of the glass transition temperature (Tg) of Ge22Te78-I-x(x) glasses, exhibits a broad hump around this composition. Based on the present results, the composition x = 5 has been identified as the inverse rigidity percolation threshold at which Ge22Te78-I-x(x) glassy system exhibits a change from a stressed rigid amorphous solid to a flexible polymeric glass. Further, a sharp minimum is seen in the composition dependence of non-reversing enthalpy (Delta H-nr) of Ge22Te78-I-x(x) glasses at x = 5, which is suggestive of a thermally reversing window at this composition. (C) 2007 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Zero entries in complex orthogonal designs (CODs) impede their practical implementation. In this paper, a method of obtaining a no zero entry (NZE) code for 2(k+1) antennas whenever a NZE code exists for 2(k) antennas is presented. This is achieved with slight increase in the ML decoding complexity for regular QAM constellations and no increase for other complex constellations. Since NZE CODs have been constructed recently for 8 antennas our method leads to NZE codes for 16 antennas. Simulation results show good performance of our new codes compared to the well known constructions for 16 and 32 antennas under peak power constraints.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, we report a systematic study of low frequency 1∕fα resistance fluctuation in thin metal films (Ag on Si) at different stages of damage process when the film is subjected to high current stressing. The resistance fluctuation (noise) measurement was carried out in situ using a small ac bias that has been mixed with the dc stressing current. The experiment has been carried out as a function of temperature in the range of 150–350 K. The experiment establishes that the current stressed film, as it undergoes damage due to various migration forces, develops an additional low-frequency noise spectral power that does not have the usual 1∕f spectral shape. The magnitude of extra term has an activated temperature dependence (activation energy of ≈0.1 eV) and has a 1∕f1.5 spectral dependence. The activation energy is the same as seen from the temperature dependence of the lifetime of the film. The extra 1∕f1.5 spectral power changes the spectral shape of the noise power as the damage process progress. The extra term likely arising from diffusion starts in the early stage of the migration process during current stressing and is noticeable much before any change can be detected in simultaneous resistance measurements. The experiment carried out over a large temperature range establish a strong correlation between the evolution of the migration process in a current stressed film and the low-frequency noise component that is not a 1∕f noise.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Studies on the electrical switching behavior of melt quenched bulk Si15Te85-xSbx glasses have been undertaken in the composition range (1 <= x <= 10), in order to understand the effect of Sb addition on the electrical switching behavior of Si15Te85-x base glass. It has been observed that all the Si15Te85-xSbx glasses studied exhibit a smooth memory type switching. Further, the switching voltages are found to decrease almost linearly with Sb content, which indicates that the metallicity of the dopant plays a dominant role in this system compared to network connectivity/rigidity. The thickness dependence of switching voltage (V-th) indicates a clear thermal origin for the switching mechanism. The temperature variation of switching voltages reveals that the Si15Te85-xSbx glasses studied have a moderate thermal stability. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Elevated depressive and anxiety symptoms during childhood and adolescence have been associated with greater risk of later ecstasy use. Ecstasy users have reported using ecstasy to reduce depression or worry, or to escape. While these findings suggest that some people use ecstasy as a form of self-medication, limited research has been conducted examining the relationship between affective symptoms, coping styles and drug use motives in ecstasy users. This cross-sectional study aimed to determine if coping style and/or ecstasy use motives are associated with current mood symptoms in ecstasy users. Methods A community sample (n = 184) of 18–35 year olds who had taken ecstasy at least once in the past 12 months completed self-report measures of depression, anxiety, ecstasy use motives and coping styles. Timeline followback methods were used to collect information on lifetime ecstasy, recent drug use and life stress. Trauma exposure was measured using the Composite International Diagnostic Interview—Trauma List. Results Coping motives for ecstasy use and an emotion-focused coping style were significantly associated with current depressive and anxiety symptoms. Emotion-focused coping mediated the relationship between a history of trauma and current anxiety symptoms and moderated the relationship between recent stressful life events and current depressive symptoms. Conclusions These findings highlight the importance of interventions targeting motives for ecstasy use, and providing coping skills training for managing stressful life events among people with co-occurring depressive/anxiety symptoms and ecstasy use.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A three-level space phasor generation scheme with common mode elimination and with reduced power device count is proposed for an open end winding induction motor in this paper. The open end winding induction motor is fed by the three-level inverters from both sides. Each two level inverter is formed by cascading two two-level inverters. By sharing the bottom inverter for the two three-level inverters on either side, the power device count is reduced. The switching states with zero common mode voltage variation are selected for PWM switching so that there is no alternating common mode voltage in the pole voltages as well as in phase voltages. Only two isolated DC-links, with half the voltage rating of a conventional three-level neutral point clamped inverter, are needed for the proposed scheme.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple, low-cost, constant frequency, analog controller is proposed for the front-end half-bridge rectifier of a single-phase transformerless UPS system to maintain near unity power factor at the input and zero dc-offset voltage at the output. The controller generates the required gating pulses by comparing the input current with a periodic, bipolar, linear carrier without sensing the input voltage. Two voltage controllers and a single integrator with reset are used to generate the required carrier. All the necessary control operations can be performed without using any PLL, multiplier and/or divider. The controller can be fabricated as a single integrated circuit. The control concept is validated through simulation and also experimentally on an 800W half-bridge rectifier. Experimental results are presented for ac-dc application, and also for ac-dc-ac UPS application with both sinusoidal and nonlinear loads. The simulation and experimental results agree well.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

At the time of restoration transmission line switching is one of the major causes, which creates transient overvoltages. Though detailed Electro Magnetic Transient studies are carried out extensively for the planning and design of transmission systems, such studies are not common in a day-today operation of power systems. However it is important for the operator to ensure during restoration of supply that peak overvoltages resulting from the switching operations are well within safe limits. This paper presents a support vector machine approach to classify the various cases of line energization in the category of safe or unsafe based upon the peak value of overvoltage at the receiving end of line. Operator can define the threshold value of voltage to assign the data pattern in either of the class. For illustration of proposed approach the power system used for switching transient peak overvoltages tests is a 400 kV equivalent system of an Indian southern gri

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The crystal structure of beta-hydroxyacyl acyl carrier protein dehydratase of Plasmodium falciparum (PfFabZ) has been determined at a resolution of 2.4 angstrom. PfFabZ has been found to exist as a homodimer (d-PfFabZ) in the crystals of the present study in contrast to the reported hexameric form (h-PfFabZ) which is a trimer of dimers crystallized in a different condition. The catalytic sites of this enzyme are located in deep narrow tunnel-shaped pockets formed at the dimer interface. A histidine residue from one subunit of the dimer and a glutamate residue from the other subunit lining the tunnel form the catalytic dyad in the reported crystal structures. While the position of glutamate remains unaltered in the crystal structure of d-PffabZ compared to that in b-PfFabZ, the histidine residue takes up an entirely different conformation and moves away from the tunnel leading to a His-Phe cis-trans peptide flip at the histidine residue. In addition, a loop in the vicinity has been observed to undergo a similar flip at a Tyr-Pro peptide bond. These alterations not only prevent the formation of a hexamer but also distort the active site geometry resulting in a dimeric form of FabZ that is incapable of substrate binding. The dimeric state and an altered catalytic site architecture make d-PfFabZ distinctly different from the FabZ structures described so far. Dynamic light scattering and size exclusion chromatographic studies clearly indicate a pH-related switching of the dimers to active hexamers. (c) 2006 Federation of European Biochemical Societies. Published by Elsevier B.V. All rights reserv.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The national resuscitation guidelines were published in Finland in 2002 and are based on international guidelines published in 2000. The main goal of the national guidelines, available on the Internet free of charge, is early defibrillation by nurses in an institutional setting. Aim: To study possible changes in cardiopulmonary resuscitation (CPR) practices, especially concerning early defibrillation, nurses and students attitudes of guideline implementation and nurses and students ability to implement the guideline recommendations in clinical practices after publication of the Current Care (CC) guidelines for CPR 2002. Material and methods: CPR practices in Finnish health centres; especially concerning rapid defibrillation programmes, as well as the implementation of CC guidelines for CPR was studied in a mail survey to chief physicians of every health centre in Finland (Study I). The CPR skills using an automated external defibrillator (AED) were compared in a study including Objective stuctured clinical examination (OSCE) of resuscitation skills of nurses and nursing students in Finnish and Swedish hospital and institution (Studies II, III). Attitudes towards CPR-D and CPR guidelines among medical and nursing students and secondary hospital nurses were studied in surveys (Studies IV, V). The nurses receiving different CPR training were compared in a randomized trial including OSCE of CPR skills of nurses in Finnish Hospital (Study VI). Results: Two years after the publication, 40.7% of Finnish health centres used national resuscitation guidelines. The proportion of health centres having at least one AED (66%) and principle of nurse-performed defibrillation without the presence of a physician (42%) had increased. The CPR-D training was estimated to be insufficient regarding basic life support and advanced life support in the majority of health centres (Study I). CPR-D skills of nurses and nursing students in two specific Swedish and Finnish hospitals and institutions (Study II and III) were generally inadequate. The nurses performed better than the students and the Swedish nurses surpassed the Finnish ones. Geriatric nurses receiving traditional CPR-D training performed better than those receiving an Internet-based course but both groups failed to defibrillate within 60 s. Thus, the performance was not satisfactory even two weeks after traditional training (Study VI). Unlike the medical students, the nursing students did not feel competent to perform procedures recommended in the cardiopulmonary resuscitation guidelines including the defibrillation. However, the majority of nursing students felt confident about their ability to perform basic life support. The perceived ability to defibrillate correlated significantly with a positive attitude towards nurse-performed defibrillation and negatively with fear of damaging the patient s heart by defibrillation (Study IV). After the educational intervention, the nurses found their level of CPR-D capability more sufficient than before and felt more confident about their ability to perform defibrillation themselves. A negative attitude toward defibrillation correlated with perceived negative organisational attitudes toward cardiopulmonary resuscitation guidelines. After CPR-D education in the hospital, the majority (64%) of nurses hesitated to perform defibrillation because of anxiety and 27 % hesitated because of fear of injuring the patient. Also a negative personal attitude towards guidelines increased markedly after education (Study V). Conclusions: Although a significant change had occurred in resuscitation practices in primary health care after publication of national cardiopulmonary resuscitation guidelines the participants CPR-D skills were not adequate according to the CPR guidelines. The current way of teaching is unlikely to result in participants being able to perform adequate and rapid CPR-D. More information and more frequent training are needed to diminish anxiety concerning defibrillation. Negative beliefs and attitudes toward defibrillation affect the nursing students and nurses attitudes toward cardiopulmonary resuscitation guidelines. CPR-D education increased the participants self-confidence concerning CPR-D skills but it did not reduce their anxiety. AEDs have replaced the manual defibrillators in most institutions, but in spite of the modern devices the anxiety still exists. Basic education does not provide nursing students with adequate CPR-D skills. Thus, frequent training in the workplace has vital importance. This multi-professional program supported by the administration might provide better CPR-D skills. Distance learning alone cannot substitute for traditional small-group learning, tutored hands-on training is needed to learn practical CPR-D skills. Standardized testing would probably help controlling the quality of learning. Training of group-working skills might improve CPR performance.