961 resultados para Williams, Otis


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To determine likely errors in estimating retinal shape using partial coherence interferometric instruments when no allowance is made for optical distortion. Method: Errors were estimated using Gullstrand’s No. 1 schematic eye and variants which included a 10 D axial myopic eye, an emmetropic eye with a gradient-index lens, and a 10.9 D accommodating eye with a gradient-index lens. Performance was simulated for two commercial instruments, the IOLMaster (Carl Zeiss Meditec) and the Lenstar LS 900 (Haag-Streit AG). The incident beam was directed towards either the centre of curvature of the anterior cornea (corneal-direction method) or the centre of the entrance pupil (pupil-direction method). Simple trigonometry was used with the corneal intercept and the incident beam angle to estimate retinal contour. Conics were fitted to the estimated contours. Results: The pupil-direction method gave estimates of retinal contour that were much too flat. The cornea-direction method gave similar results for IOLMaster and Lenstar approaches. The steepness of the retinal contour was slightly overestimated, the exact effects varying with the refractive error, gradient index and accommodation. Conclusion: These theoretical results suggest that, for field angles ≤30º, partial coherence interferometric instruments are of use in estimating retinal shape by the corneal-direction method with the assumptions of a regular retinal shape and no optical distortion. It may be possible to improve on these estimates out to larger field angles by using optical modeling to correct for distortion.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Abstract Purpose: To determine how high and low contrast visual acuities are affected by blur caused by crossed-cylinder lenses. Method: Crossed-cylinder lenses of power zero (no added lens), +0.12 DS/-0.25 DC, +0.25 DS/-0.50 DC and +0.37/-0.75 DC were placed over the correcting lenses of the right eyes of eight subjects. Negative cylinder axes used were 15-180 degrees in 15 degree step for the two higher crossed-cylinders and 30-180 degrees in 30 degree steps for the lowest crossed cylinder. Targets were single lines of letters based on the Bailey-Lovie chart. Successively smaller lines were read until the subject could not read any of the letters correctly. Two contrasts were used: high (100%) and low (10%). The screen luminance of 100 cd/m2, together with the room lighting, gave pupil sizes of 4.5 to 6 mm. Results: High contrast visual acuities were better than low contrast visual acuities by 0.1 to 0.2 log unit (1 to 2 chart lines) for the no added lens condition. Based on comparing the average of visual acuities for the 0.75 D crossed-cylinder with the best visual acuity for a given contrast and subject, the rates of change of visual acuity per unit blur strength were similar for high contrast (0.34± 0.05 logMAR/D) and low contrast (0.37± 0.09 logMAR/D). There were considerable asymmetry effects, with the average loss in visual acuity across the two contrasts and the 0.50D/0.75 D crossed-cylinders doubling between the 165± and 60± negative cylinder axes. The loss of visual acuity with 0.75 D crossed-cylinders was approximately twice times that occurring for defocus of the same blur strength. Conclusion: Small levels of crossed-cylinder blur (≤0.75D) produce losses in visual acuity that are dependent on the cylinder axis. 0.75 D crossed-cylinders produce losses in visual acuity that are twice those produced by defocus of the same blur strength.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose. The Useful Field of View (UFOV(R)) test has been shown to be highly effective in predicting crash risk among older adults. An important question which we examined in this study is whether this association is due to the ability of the UFOV to predict difficulties in attention-demanding driving situations that involve either visual or auditory distracters. Methods. Participants included 92 community-living adults (mean age 73.6 +/- 5.4 years; range 65-88 years) who completed all three subtests of the UFOV involving assessment of visual processing speed (subtest 1), divided attention (subtest 2), and selective attention (subtest 3); driving safety risk was also classified using the UFOV scoring system. Driving performance was assessed separately on a closed-road circuit while driving under three conditions: no distracters, visual distracters, and auditory distracters. Driving outcome measures included road sign recognition, hazard detection, gap perception, time to complete the course, and performance on the distracter tasks. Results. Those rated as safe on the UFOV (safety rating categories 1 and 2), as well as those responding faster than the recommended cut-off on the selective attention subtest (350 msec), performed significantly better in terms of overall driving performance and also experienced less interference from distracters. Of the three UFOV subtests, the selective attention subtest best predicted overall driving performance in the presence of distracters. Conclusions. Older adults who were rated as higher risk on the UFOV, particularly on the selective attention subtest, demonstrated poorest driving performance in the presence of distracters. This finding suggests that the selective attention subtest of the UFOV may be differentially more effective in predicting driving difficulties in situations of divided attention which are commonly associated with crashes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

To compare measurements of retinal thickness (RT) and choroidal thickness (ChT) obtained with an optical low coherence reflectometry (OLCR) biometer (Lenstar LS 900) with those obtained with a spectral domain optical coherence tomographer (SD OCT) (Copernicus SOCT HR) in young normal subjects.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose. To investigate how temporal processing is altered in myopia and during myopic progression. Methods. In backward visual masking, a target's visibility is reduced by a mask presented quickly after the target. Thirty emmetropes, 40 low myopes, and 22 high myopes aged 18 to 26 years completed location and resolution masking tasks. The location task examined the ability to detect letters with low contrast and large stimulus size. The resolution task involved identifying a small letter and tested resolution and color discrimination. Target and mask stimuli were presented at nine short interstimulus intervals (12 to 259 ms) and at 1000 ms (long interstimulus interval condition). Results. In comparison with emmetropes, myopes had reduced ability in both locating and identifying briefly presented stimuli but were more affected by backward masking for a low contrast location task than for a resolution task. Performances of low and high myopes, as well as stable and progressing myopes, were similar for both masking tasks. Task performance was not correlated with myopia magnitude. Conclusions. Myopes were more affected than emmetropes by masking stimuli for the location task. This was not affected by magnitude or progression rate of myopia, suggesting that myopes have the propensity for poor performance in locating briefly presented low contrast objects at an early stage of myopia development.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

AMERICAN playwright Tennessee Williams is renowned for family dramas that deal with sex, desire, infidelity and secrets, topics still taboo when Williams was writing in the 1940s and 50s...

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Study Design. A sheep study designed to compare the accuracy of static radiographs, dynamic radiographs, and computed tomographic (CT) scans for the assessment of thoracolumbar facet joint fusion as determined by micro-CT scanning. Objective. To determine the accuracy and reliability of conventional imaging techniques in identifying the status of thoracolumbar (T13-L1) facet joint fusion in a sheep model. Summary of Background Data. Plain radiographs are commonly used to determine the integrity of surgical arthrodesis of the thoracolumbar spine. Many previous studies of fusion success have relied solely on postoperative assessment of plain radiographs, a technique lacking sensitivity for pseudarthrosis. CT may be a more reliable technique, but is less well characterized. Methods. Eleven adult sheep were randomized to either attempted arthrodesis using autogenous bone graft and internal fixation (n = 3) or intentional pseudarthrosis (IP) using oxidized cellulose and internal fixation (n = 8). After 6 months, facet joint fusion was assessed by independent observers, using (1) plain static radiography alone, (2) additional dynamic radiographs, and (3) additional reconstructed spiral CT imaging. These assessments were correlated with high-resolution micro-CT imaging to predict the utility of the conventional imaging techniques in the estimation of fusion success. Results. The capacity of plain radiography alone to correctly predict fusion or pseudarthrosis was 43% and was not improved using plain radiography and dynamic radiography with also a 43% accuracy. Adding assessment by reformatted CT imaging to the plain radiography techniques increased the capacity to predict fusion outcome to 86% correctly. The sensitivity, specificity, and accuracy of static radiography were 0.33, 0.55, and 0.43, respectively, those of dynamic radiography were 0.46, 0.40, and 0.43, respectively, and those of radiography plus CT were 0.88, 0.85, and 0.86, respectively. Conclusion. CT-based evaluation correlated most closely with high-resolution micro-CT imaging. Neither plain static nor dynamic radiographs were able to predict fusion outcome accurately. © 2012 Lippincott Williams & Wilkins.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: To measure tear film surface quality (TFSQ) using dynamic high-speed videokeratoscopy during short-term (8 hours) use of rigid and soft contact lenses. Methods: A group of fourteen subjects wore 3 different types of contact lenses on 3 different non-consecutive days (order randomized) in one eye only. Subjects were screened to exclude those with dry eye. The lenses included a PMMA hard, an RGP (Boston XO) and a soft silicone hydrogel lens. Three 30 second long high speed videokeratoscopy recordings were taken with contact lenses in-situ, in the morning and again after 8 hours of contact lens wear, both in normal and suppressed blinking conditions. Recordings were also made on a baseline day with no contact lens wear. Results: The presence of a contact lens in the eye had a significant effect on the mean TFSQ in both natural and suppressed blinking conditions (p=0.001 and p=0.01 respectively, repeated measures ANOVA). TFSQ was worse with all the lenses compared to no lens in the eye (in the afternoon during both normal and suppressed blinking conditions (all p<0.05). In natural blinking conditions, the mean TFSQ for the PMMA and RGP lenses was significantly worse than the baseline day (no lens) for both morning and afternoon measures (p<0.05). Conclusions: This study shows that both rigid and soft contact lenses adversely affect the TFSQ in both natural and suppressed blinking conditions. No significant differences were found between the lens types and materials. Keywords: Tear film surface quality, rigid contact lens, soft contact lens, dynamic high-speed videokeratoscopy

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose. To investigate whether diurnal variation occurs in retinal thickness measures derived from spectral domain optical coherence tomography (SD-OCT). Methods. Twelve healthy adult subjects had retinal thickness measured with SD-OCT every 2 h over a 10 h period. At each measurement session, three average B-scan images were derived from a series of multiple B-scans (each from a 5 mm horizontal raster scan along the fovea, containing 1500 A-scans/B-scan) and analyzed to determine the thickness of the total retina, as well as the thickness of the outer retinal layers. Average thickness values were calculated at the foveal center, at the 0.5 mm diameter foveal region, and for the temporal parafovea (1.5 mm from foveal center) and nasal parafovea (1.5 mm from foveal center). Results. Total retinal thickness did not exhibit significant diurnal variation in any of the considered retinal regions (p > 0.05). Evidence of significant diurnal variation was found in the thickness of the outer retinal layers (p < 0.05), with the most prominent changes observed in the photoreceptor layers at the foveal center. The photoreceptor inner and outer segment layer thickness exhibited mean amplitude (peak to trough) of daily change of 7 ± 3 μm at the foveal center. The peak in thickness was typically observed at the third measurement session (mean measurement time, 13:06). Conclusions. The total retinal thickness measured with SD-OCT does not exhibit evidence of significant variation over the course of the day. However, small but significant diurnal variation occurs in the thickness of the foveal outer retinal layers.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The ubiquitin (Ub)-proteasome pathway is the major nonlysosomal pathway of proteolysis in human cells and accounts for the degradation of most short-lived, misfolded or damaged proteins. This pathway is important in the regulation of a number of key biological regulatory mechanisms. Proteins are usually targeted for proteasome-mediated degradation by polyubiquitinylation, the covalent addition of multiple units of the 76 amino acid protein Ub, which are ligated to 1-amino groups of lysine residues in the substrate. Polyubiquitinylated proteins are degraded by the 26S proteasome, a large, ATP-dependent multicatalytic protease complex, which also regenerates monomeric Ub. The targets of this pathway include key regulators of cell proliferation and cell death. An alternative form of the proteasome, termed the immunoproteasome, also has important functions in the generation of peptides for presentation by MHC class I molecules. In recent years there has been a great deal of interest in the possibility that proteasome inhibitors, through elevation of the levels of proteasome targets, might prove useful as a novel class of anti-cancer drugs. Here we review the progress made to date in this area and highlight the potential advantages and weaknesses of this approach.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: The effect of extreme temperature has become an increasing public health concern. Evaluating the impact of ambient temperature on morbidity has received less attention than its impact on mortality. METHODS: We performed a systematic literature review and extracted quantitative estimates of the effects of hot temperatures on cardiorespiratory morbidity. There were too few studies on effects of cold temperatures to warrant a summary. Pooled estimates of effects of heat were calculated using a Bayesian hierarchical approach that allowed multiple results to be included from the same study, particularly results at different latitudes and with varying lagged effects. RESULTS: Twenty-one studies were included in the final meta-analysis. The pooled results suggest an increase of 3.2% (95% posterior interval = -3.2% to 10.1%) in respiratory morbidity with 1°C increase on hot days. No apparent association was observed for cardiovascular morbidity (-0.5% [-3.0% to 2.1%]). The length of lags had inconsistent effects on the risk of respiratory and cardiovascular morbidity, whereas latitude had little effect on either. CONCLUSIONS: The effects of temperature on cardiorespiratory morbidity seemed to be smaller and more variable than previous findings related to mortality.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The National Morbidity, Mortality, and Air Pollution Study (NMMAPS) was designed to examine the health effects of air pollution in the United States. The primary question was whether particulate matter was responsible for the associations between air pollution and daily mortality. Secondary questions concerned measurement error in air pollution and mortality displacement.1 Since then, NMMAPS has been used to answer many important questions in environmental epidemiology...

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The past decade has seen increasing numbers of government programs funded to support vulnerable families with young children. Supported playgroups are one important strategy in Australia’s current family policies that are provided in all states and territories (ARTD, 2008). National policies have increasingly invested in family support programs, such as supported playgroups. Despite known challenges in engaging vulnerable families in support programs, little is known about the capacity of supported playgroups to effectively engage families to achieve desired outcomes. This project explores family patterns of attendance in supported playgroups and examines the extent to which parental characteristics and experiences of the playgroup explain variations in engagement. The findings can inform the delivery of other family support programs...

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background Improving timely access to reperfusion is a major goal of ST-segment–elevation myocardial infarction care. We sought to compare the population impact of interventions proposed to improve timely access to reperfusion therapy in Australia. Methods and Results Australian hospitals, population, and road network data were integrated using Geographical Information Systems. Hospitals were classified into those that provided primary percutaneous coronary intervention (PPCI) or fibrinolysis. Population impact of interventions proposed to improve timely access to reperfusion (PPCI, fibrinolysis, or both) were modeled and compared. Timely access to reperfusion was defined as the proportion of the population capable of reaching a fibrinolysis facility ≤60 minutes or a PPCI facility ≤120 minutes from emergency medical services activation. The majority (93.2%) of the Australian population has timely access to reperfusion, mainly (53%) through fibrinolysis. Only 40.2% of the population had timely access to PPCI, and access to PPCI services is particularly limited in regional and nonexistent in remote areas. Optimizing the emergency medical services’ response or increasing PPCI services resulted in marginal improvement in timely access (1.8% and 3.7%, respectively). Direct transport to PPCI facilities and interhospital transfer for PPCI improves timely access to PPCI for 19.4% and 23.5% of the population, respectively. Prehospital fibrinolysis markedly improved access to timely reperfusion in regional and remote Australia. Conclusions Significant gaps in timely provision of reperfusion remain in Australia. Systematic implementation of changes in service delivery has potential to improve timely access to PPCI for a majority of the population and improve access to fibrinolysis to those living in regional and remote areas.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The structure of the 1:1 brucinium salt of cis-cyclohexane-1,2-dicarboxylic acid, 2,3-dimethoxy-10-oxostrychnidinium (1R,2S)-2-carboxycyclohexane-1-carboxylate dihydrate, has revealed the resolved (1R,2S) enantiomer of the acid. Crystals of the compound are orthorhombic, space group P212121, with unit cell dimensions a = 8.1955(3), b = 12.4034(3), c = 29.9073(9)Å, and Z = 4. The asymmetric unit comprises the brucinium cation, the hydrogen cis-cyclohexane-1,2-dicarboxylate cation, in which the carboxylate group is disordered over two sites (58, 42%), and two water molecules of solvation, one of which is occupies two 50% occupancy sites. The classic undulating brucinium cation substructures are present with the anion and the water molecules occupying the interstitial cavities and are hydrogen-bonded to them in a two-dimensional network structure.