904 resultados para WIRE
Resumo:
The aim of this study was to evaluate the tensile strength of orthodontic wires bonded onto the enamel with cyanoacrylate ester. To obtain the specimens, 120 human premolars (extracted for orthodontic or periodontal reasons) were included in acrylic blocks of rapid polymerization with three teeth each. Four groups were formed with ten specimens each. In the specimens, a dental splint model was made with cyanoacrylate ester and round stainless steel wire. In groups I, II and III, cyanoacrylate ester was used with round steel wires, with variation in diameter: 0.014 inches; 0.016 inches and 0.018 inches, respectively. In group IV, round steel wire 0.018 inches was used with photo polymerizing resin composite with previous acid etching. The adhesive force of the materials was measured in two points under the action of the tensiometer (ETM-USA). The number of loose wires was counted along with those that remained fixed according to the different levels of force applied because of the direction of the tensile force (vertical or horizontal) and the diameter of the wire used. The data obtained were first submitted to a descriptive analysis and then submitted to a statistical analysis (Friedman's Test and Dunn's Test of Multiple Comparison - Epi-info 3.2). Within the limitations of the experimental conditions presented, the cyanoacrylate ester or 'Super Bonder (R)' maintained bonded to enamel and steel wires (0.016 and 0.018 inches) during the tensile strength tests under different levels of applied forces.
Resumo:
This paper reports a case of tooth replantation in which the splinting was performed with stainless steel orthodontic wire and a widely marketed brand of quick-setting cyanoacrylate ester adhesive (Super Bonder((R))). The long-term clinical and radiographic success of the case reported in this paper indicates that the splinting technique using a quick-setting cyanoacrylate ester adhesive may be a feasible option for making a rapid, simple and efficient contention of replanted teeth in situations where the routinely used materials are not readily available.
Resumo:
OBJETIVO: a reabsorção radicular apical é uma condição comumente observada durante e após o tratamento ortodôntico e fatores como tipo de aparelhagem ortodôntica utilizada, magnitude das forças aplicadas e duração do tratamento podem estar relacionados ao processo de arredondamento do ápice radicular. Buscou-se avaliar, por meio de imagens radiográficas computadorizadas, a quantidade de reabsorção no ápice radicular, quando da utilização de duas diferentes técnicas de mecânica ortodôntica fixa: Edgewise com acessórios padrão e Edgewise com acessórios totalmente programados. METODOLOGIA: a amostra constituiu-se de 20 pacientes tratados pelo mesmo profissional na Clínica de Ortodontia da Faculdade de Odontologia de Araçatuba - UNESP. Os pacientes foram divididos em dois grupos: grupo 1 (Tratados com Edgewise com acessórios padrão e fios de aço) e grupo 2 (Tratados com Edgewise com acessórios totalmente programados e fios de níquel-titânio). A avaliação radiográfica digital foi realizada por um único operador por meio de exposições radiográficas digitais feitas no início do tratamento ortodôntico, após retração de caninos e final de tratamento, utilizando o sistema de escores proposto por Levander e Malmgren (1988). RESULTADOS E CONCLUSÕES: a análise dos escores permitiu concluir que o tratamento ortodôntico empregando a técnica Edgewise com acessórios totalmente programados e fios de níquel-titânio apresentou menores graus de reabsorção radicular apical, em comparação à técnica Edgewise com acessórios padrão e fios de aço. Observou-se que, independentemente da técnica empregada, o tratamento ortodôntico como um todo apresentou um grau moderado de reabsorção radicular apical.
Resumo:
OBJETIVO: avaliar o sistema de forças gerado pela mola T centralizada no espaço interbraquete, com pré-ativação preconizada por Burstone. MÉTODOS: utilizando-se modelos fotoelásticos, a mola T com pré-ativações preconizadas por Burstone, confeccionada com fio retangular de titânio-molibdênio (TMA) de secção 0,017x 0,025, centralizada e com ativação de 6mm, 3mm e em posição neutra. Para melhor confiabilidade dos resultados, os testes foram repetidos em três modelos igualmente duplicados e confeccionados pelo mesmo operador. Utilizou-se uma distância interbraquetes de 27mm. Para compreensão dos resultados, as franjas foram visualizadas através do polariscópio, fotografadas e analisadas qualitativamente. RESULTADOS: por meio da análise qualitativa da ordem de franjas no modelo fotoelástico, notou-se que, nas extremidades de retração e ancoragem, ambas apresentaram simetria no sistema de força, em toda extensão radicular.
Resumo:
The purpose of this study was to evaluate histologically, in dogs, the periodontal healing of 1-walled intraosseous defects in teeth that were subjected to orthodontic movement toward the defects. The defects were surgically created bilaterally at the mesial aspects of the maxillary second premolars and distal aspects of the mandibular second premolars of 4 mongrel dogs. One week after creating the defects, an orthodontic appliance was installed, and the teeth were randomly assigned to 1 of 2 treatment groups: those in the test group received a titanium-molybdenum alloy rectangular wire spring that performed a controlled tipping root movement, and those in the control group received a passive stainless steel wire. Active orthodontic movement of the test teeth lasted 2 months and was followed by a stabilization period of another 2 months, after which the animals were killed. Throughout the study, routine daily plaque control was performed on the dogs with a topical application of a 2% chlorhexicline gel. The results showed no difference between the groups, with some regularization of the defects and periodontal regeneration limited to the apical portion of the defects. Histometric analysis showed a significant difference in bone height; on average, it was 0.53 mm smaller in the test group. It was concluded that orthodontic movement does not interfere with the healing of 1-walled intraosseous defects, with the exception of the linear extent of new bone apposition.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Coupled intersubband plasmon-phonon modes are studied in a multisubband parabolic quantum wire at room temperatures. These modes are found by calculating the spectral weight function which is related to the inelastic Raman spectra. We use a 13 subband model. The plasmon-phonon coupling strongly modifies the dispersion relation of the intersubband modes in the vicinity of the optical phonon frequency omega(LO). Extra modes show up as a result of the electron-phonon interaction. We carefully study the density and temperature dependence of these extra modes. We also show that coupled intersubband plasmon-phonon modes should be observed for temperatures as high as 300 K.
Resumo:
We consider the Euclidean D-dimensional -lambda vertical bar phi vertical bar(4)+eta vertical bar rho vertical bar(6) (lambda,eta > 0) model with d (d <= D) compactified dimensions. Introducing temperature by means of the Ginzburg-Landau prescription in the mass term of the Hamiltonian, this model can be interpreted as describing a first-order phase transition for a system in a region of the D-dimensional space, limited by d pairs of parallel planes, orthogonal to the coordinates axis x(1), x(2),..., x(d). The planes in each pair are separated by distances L-1, L-2, ... , L-d. We obtain an expression for the transition temperature as a function of the size of the system, T-c({L-i}), i = 1, 2, ..., d. For D = 3 we particularize this formula, taking L-1 = L-2 = ... = L-d = L for the physically interesting cases d = 1 (a film), d = 2 (an infinitely long wire having a square cross-section), and for d = 3 (a cube). For completeness, the corresponding formulas for second-order transitions are also presented. Comparison with experimental data for superconducting films and wires shows qualitative agreement with our theoretical expressions.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
A fast, low-cost, convenient, and especially sensitive voltammetric screening approach for the study of the antioxidant properties of isoquercitrin and pedalitin from Pterogyne nitens is suggested in this work. These flavonoids were investigated for their redox properties using cyclic voltammetry in nonaqueous media using N,N-dimethylformamide and tetrabutylammonium tetrafluorborate as the supporting electrolyte, a glassy carbon working electrode, AglAgCl reference electrode, and Pt bare wire counter electrode. The comparative analysis of the activity of rutin has also been carried out. Moreover, combining HPLC with an electrochemical detector allowed qualitative and quantitative detection of micromolecules (e.g., isoquercitrin and pedalitin) that showed antioxidant activities. These results were then correlated to the inhibition of p-carotene bleaching determined by TLC autographic assay and to structural features of the flavonoids.
Resumo:
OBJETIVO: o presente estudo teve como objetivo comparar dois tipos de contenções ortodônticas fixas, em relação a parâmetros periodontais estabelecidos. A contenção com fio trançado é a mais comumente utilizada e a contenção modificada apresenta dobras que têm a finalidade de permitir o livre acesso do fio dental às áreas interproximais. MÉTODOS: para esse estudo cruzado, foram selecionados 12 voluntários que utilizaram, por 6 meses, A) Contenção com fio trançado e B) Contenção modificada - sendo essas fixadas em todos os dentes do segmento anterior. Após esse período experimental, foram feitas as seguintes avaliações: Índice de Placa Dentária, Índice Gengival, Índice de Cálculo Dentário e Índice de Cálculo ao longo do fio de contenção. Os voluntários também responderam a um questionário com relação à utilização, conforto e higienização das contenções. RESULTADOS: foi observado que o índice de placa e o índice gengival foram maiores nas faces linguais (p<0,05) para a contenção modificada. Além disso, o índice de cálculo foi estatisticamente maior (p<0,05) considerando-se as faces linguais e proximais na utilização da contenção modificada. O índice de cálculo ao longo do fio também apresentou valores significativamente maiores (p<0,05) na contenção modificada. em relação ao questionário, 58% dos voluntários consideraram que a contenção modificada é mais desconfortável; e 54% deles preferiram a contenção com fio trançado. CONCLUSÃO: a partir dos resultados obtidos, pode-se concluir que a contenção com fio trançado apresentou melhores resultados do que a contenção modificada, de acordo com os parâmetros periodontais avaliados, além de apresentar maior conforto e preferência na sua utilização.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
O trauma do seio frontal não é raro, correspondendo a 8% das fraturas faciais. Pode afetar a lâmina anterior e/ou posterior, com ou sem envolvimento do ducto nasofrontal. Tem alto potencial para complicações e seu manejo ainda é controvertido em algumas situações. OBJETIVO: Apresentar a epidemiologia, o diagnóstico e tratamento clínico e cirúrgico de 24 pacientes com fratura do seio frontal. MATERIAL E MÉTODOS: Estudo retrospectivo, não randomizado, de 24 pacientes com fratura de seio frontal operados no Hospital das Clínicas da Faculdade de Medicina de Botucatu, São Paulo, Brasil. RESULTADOS: Dos 24 pacientes, 16 tinham fraturas da lâmina externa e 8, da lâmina interna e externa. em 2 casos havia lesão do ducto nasofrontal. Vinte (83,4%) pacientes tiveram fraturas faciais associadas e em 13 (54,2%) foram observadas complicações intracranianas. A incisão em asa de borboleta, abaixo da sobrancelha, foi empregada na maioria dos casos cirúrgicos com bom resultado estético. Fixação dos fragmentos ósseos com diferentes materiais (fio de aço, mononylon, miniplacas de titânio) e, se necessário, reconstrução da tábua anterior com material aloplástico ou osso parietal. CONCLUSÃO: A causa principal das fraturas do seio frontal é acidente com veículos. O tratamento depende de sua complexidade, pois comumente há lesões cranioencefálicas associadas. As técnicas cirúrgicas utilizadas são as incisões, retalho bicoronal ou na sobrancelha, infra-orbital (em asa de borboleta), associadas à cirurgia endoscópica em casos de infecção fístula liquórica e complicações orbitárias.