958 resultados para Tomografia computadorizada de feixe cônico


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Exercise, in general have the ability to promote health, reduce loss of physical fitness, reduce declines in body composition and prevent disease, and promote improvements in athletic performance, and that's consensual today. Through analysis of body composition and physical fitness, you can diagnose the possible individuals at risk of developing diseases, and fractures caused by falls in the elderly. The DXA tests were used (densitometry by dual beam X-ray) to assess body composition and regional, 1 RM test to evaluate the maximum strength and girth measurements, diameters and skin folds in order to analyze the balance of power muscle with both body composition as regional. The results showed that the variance in bone mass between older content related to the change in the maximum muscular strength of the upper and lower limbs, but the force values are not related to increased muscle mass. The development of muscle strength fulfills a dual function in aging which is to maintain or reduce the rate of loss of lean body mass, and also so the body bone health

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The X-ray fluorescence analysis (XRF) is an important technique for the qualitative and quantitative determination of chemical components in a sample. It is based on measurement of the intensity of the emitted characteristic radiation by the elements of the sample, after being properly excited. One of the modalities of this technique is the total reflection x-ray fluorescence (TXRF). In TXRF, the angle of refraction of the incident beam tends to zero and the refracted beam is tangent to the sample-support interface. Thus, there is a minimum angle of incidence that there is no refracted beam and all the incident radiation undergoes total reflection. As it is implemented in very small samples, in a film format, self-absorption effects should not very relevant. In this study, we evaluated the feasibility of using code MCNPX (Monte Carlo N - Particle eXtended), to simulate a measure implemented by the TXRF technique. In this way, it was verified the quality of response of a system by TXRF spectroscopy using synchrotron radiation as excitation beam for a simple setup, by retrieving the characteristic energies and the concentrations of the elements in the sample. The steps of data processing, after obtaining the excitation spectra, were the same as in a real experiment and included the obtaining of the sensitivity curve for the simulated system. The agreement between the theoretical and simulated values of Ka characteristic energies for different elements was lower than 1 % .The obtained concentration of the elements of the sample had high relatively errors ( between 6 and 60 % ) due mainly to lack of knowing about some realistic physical parameters of the sample , such as density . In this way, this result does not preclude the use of MCNPX code for this type of application

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Class II malocclusion features a high prevalence in Brazil, being considered as a routine in orthodontic clinics. A number of appliances are shown in the literature in order to correct Class II malocclusion with mandibular retrusion. Herbst´s fixed functional appliance, idealized by Emil Herbst (1905) and reintroduced, in the 1980´s, by Hans Pancherz is highlighted for maintaining the mandible continuously advanced, showing a shorter active treament time, an immediate esthetic impact on the facial profile, as well as requiring no patient´s commitment. Recent researches indicate the use of this appliance in individuals after pubertal growth surge. The aim of the present study is to show the orthodontics practitioner the option to use this appliance so as to treat Class II in individuals after the growth surge, obtaining satisfactory outcomes and further Class II correction.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico(CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In view of the low loading values commonly employed in dentistry, a load-application device (LAD) was developed as option to the universal testing machine (UTM), using strain gauge analysis. The aim of this study was to develop a load-application device (LAD) and compare the LAD with the UTM apparatus under axial and non-axial loads. An external hexagonal implant was inserted into a polyurethane block and one EsthetiCone abutment was connected to the implant. A plastic prosthetic cylinder was screwed onto the abutment and a conical pattern crown was fabricated using acrylic resin. An impression was made and ten identical standard acrylic resin patterns were obtained from the crown impression, which were cast in nickel-chromium alloy (n=10). Four strain gauges were bonded diametrically around the implant. The specimens were subjected to central (C) and lateral (L) axial loads of 30 kgf, on both devices: G1: LAD/C; G2: LAD/L; G3: UTM/C; G4: UTM/L. The data (με) were statistically analyzed by repeated measures ANOVA and Tukey's test (p<0.05). No statistically significant difference was found between the UTM and LAD devices, regardless of the type of load. It was concluded that the LAD is a reliable alternative, which induces microstrains to implants similar to those obtained with the UTM.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Ciências Cartográficas - FCT

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The contamination of the physical environment occurs as a result of the lack of planning and inadequate management of hazardous products. Due to the difficulty of the characterization and study of soil and groundwater, the contamination has been long neglected. The characterization of these areas by research techniques through direct methods such as physical and chemical analysis, are widely used in the diagnosis and monitoring. However, despite presenting quantitative results, this method is not representative in spatial terms. The purpose of this work is to bring geophysical complementation with the diagnosis, bringing the spatial element for the detection of the contamination plume. In the study area, there was a railway accident in 1999 in which three wagons fell and spilled 240,000 L of diesel onto the soil. The main objective is to assess the presence of contaminants in the residual phase and dissolved in the subsurface, using the technique of Electrical Tomography (ETR), understand the effects of natural attenuation process in the degradation of hydrocarbons and changes in electrical properties in soil and groundwater. The results allowed the definition of three distinct patterns of resistivity region with presence of dissolved phase, set in a historical chemical analyzes: low values (> 60Ω.m) associated with the presence of hydrocarbons in an advanced stage of degradation, intermediate values (260Ω.me 511Ω .m) indicative of coexistence of residual hydrocarbons and dissolved phase, and high values (> 1000Ω.m), which reveal the prevalence of residual phase with incipient degradation, possibly in high toxicity concentrations for effective action of biodegradation processes. The diagnostic of areas with potential accumulation of residual phase can subsidize the planning of remediation techniques and promote the complete decontamination of the area

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Alimentos e Nutrição - FCFAR

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The dentist has been suggested as a professional vulnerable to labor risks mainly related to working posture. This study examined the application of ergonomics principles during the dental attendances made by university student of the last period of the Araçatuba Dental University. Twenty-four attendants were photographed and the images were digitally analyzed for the verification of 10 requirements that determine a healthy labor posture, defined by the project ISO Standard / TC 106/SC 6 N 411. It was observed that 50% of items from the check list obtained higher percentages of negative replies. The students had greater difficulties as to the correct position of the angle between the upper and lower leg when sitting, the ideal adjustment of the light focus reflector in the field of work and the patient positioning. It was concluded that the dental attendances were held without compliance with the ergonomic requirements. The greatest difficulties regarding the work posture were the sitting posture, the light beam and the patient positioning. Students need better guidance about ergonomic principles and requirements, which should occur at any time of life, but earliest they are installed, greater the benefits, assimilation and incorporation of adequate working postures will be. We need a reform that addresses all sectors of the dental system, so that learning and application of ergonomics in dentistry become effective, efficient and effective.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: the granular cell odontogenic tumors are an uncommon neoplasm with benign clinical behavior. The lesion occurs over a wide age range with a typically predilection for the mandibular canine and molar regions. Aim: present a granular cell odontogenic tumor literature review. Conclusions: the tumor don’t present an aggressive biological behavior although recurrences can occur. The lesion is treated by conservative surgery with curettage and enucleation as election procedures.