967 resultados para Power efficiency
Resumo:
First IFAC Workshop on Fractional Differentiation and Its Application - 19-21 July 2004, Enseirb, Bordeaux, France - FDA'04
Resumo:
This paper reports investigation on the estimation of the short circuit impedance of power transformers, using fractional order calculus to analytically study the influence of the diffusion phenomena in the windings. The aim is to better characterize the medium frequency range behavior of leakage inductances of power transformer models, which include terms to represent the magnetic field diffusion process in the windings. Comparisons between calculated and measured values are shown and discussed.
Resumo:
Dissertação para obtenção do Grau de Mestre em Energias Renováveis – Conversão Eléctrica e Utilização Sustentáveis
Resumo:
Atualmente a situação económica do país é delicada, como tal, a redução dos consumos energéticos é uma mais-valia tanto para os consumidores como para o meio ambiente. A evolução tecnológica nos últimos anos possibilita a realização de soluções para resolver esse problema. A monitorização constante dos consumos de energia elétrica pode fazer com que esta redução seja concretizada. Relativamente ao caso concreto do edificado, o consumo de energia nos edifícios Europeus é muito significativo, quer ao nível das soluções construtivas, dos sistemas e dos equipamentos. Como tal, podem ser tomadas medidas que podem ter um impacto significativo para a redução dos consumos. O presente trabalho passa pelo estudo do potencial para a eficiência energética de três lares de idosos situados no Porto. A auditoria efetuada revelou um enorme potencial de poupança energética, nomeadamente de energia elétrica e gás natural. As medidas a adotar para reduzir os consumos energéticos do edifício passam pela substituição da iluminação existente por uma mais eficiente e de menor potência, a instalação de painéis solares para reduzir o consumo destinado às águas quentes sanitárias (nos dois lares que ainda não possuem este tipo de sistema), a substituição das caldeiras a gás natural por biomassa, a instalação de equipamentos para monitorização de consumos, entre outros. Através da recolha e tratamento de dados com um analisador de energia foi possível verificar que a implementação de uma solução de monitorização de consumos energéticos nos lares poderá permitir baixar os custos da fatura energética.
Resumo:
A presente tese tem como principal objectivo abordar o tema da eficiência energética em edifícios, no que se refere aos sistemas de climatização. O desenvolvimento deste projecto realizou-se em torno dos consumos energéticos dos diferentes sistemas de climatização estudados (e por conseguinte da envolvente do edifício), focando o cumprimento dos requisitos térmico e energéticos das normas vigentes (RCCTE e RSECE) em Portugal, tendo como objectivo identificar os parâmetros com maior impacto e a relação tendencial entre as soluções construtivas e tecnológicas adoptadas, sempre com o horizonte de maximizar a eficiência energética e diminuir a dependência face à energia primária e consequentemente a emissão de gases que provocam o efeito de estufa. É âmbito desta tese comparar diferentes tipos de sistemas de climatização a nível energético e torná-los os mais eficientes possíveis, para que também se possam tornar monetariamente aliciantes e aumentar o rácio entre benefício/custo. Para tal, numa primeira fase foi feito um estudo térmico da envolvente do edifício, tendo sido utilizado um software de simulação energética de edifícios acreditado pela norma ASHRAE 140-2004 para se poder compreender como o edifício se comportava ao longo do ano, e introduzir algumas correcções na respectiva envolvente, para baixar as potências térmicas/eléctricas dos equipamentos do sistema de AVAC. De seguida foram estudados três sistemas possíveis de climatização para o edifício, de modo a identificar o mais eficiente numa base anual, bem como a possibilidade de combinar o uso de fontes de energia renováveis com o intuito de satisfazer ao máximo as necessidades térmicas do edifício e, ainda, de minimizar o consumo de energia de origem não renovável. Por fim, para avaliar as diferentes potencialidades de cada sistema de climatização estudado, fez-se o respectivo estudo à sua viabilidade económica. Nas considerações finais da presente tese é realizado um estudo aos benefícios que uma possível alteração da arquitectura do edifício pode trazer no aumento da iluminação natural do mesmo integrado com um controlo da iluminação artificial necessária para os diferentes espaços climatizados. Os resultados obtidos foram comparados entre si e corrigir a envolvente exterior reduz os consumos energéticos do edifício em cerca de 11%. As medidas correctivas propostas no sistema de climatização base originam uma redução energética igual a 43%. A nível ambiental, é possível a redução do número de emissões de CO2 em cerca de 72.1%.
Resumo:
Nos tempos atuais as empresas que atuam no ramo dos sistemas elétricos de energias enfrentam desafios cada vez mais exigentes, dado o enquadramento normativo a que estão sujeitas por parte da entidade reguladora dos serviços energéticos. No caso do Arquipélago dos Açores, o normativo relativo ao regulamento da qualidade de serviço entrou em vigor em 2006, trazendo à EDA,S.A. (Eletricidade dos Açores), entidade responsável pelo transporte e distribuição de energia na região, novas exigências para adequados níveis de eficiência e de garantias aos clientes, no que respeita à qualidade de serviço que lhes é prestado. No âmbito deste trabalho, é efetuado o estudo do trânsito de potência sobre a rede distribuição 15 kV da ilha Graciosa. Para tal, é realizada a modelização da rede no software de rede elétricas porwerworld 8.0. e são idealizados um conjunto de cenários de exploração da rede, que visam simular situações reais que ocorrem na exploração diária da rede de distribuição da ilha. Nas simulações a efetuar consideram-se dois cenários com perfil de carga distintos, um referente à ponta máxima, e outro referente ao vazio mínimo, verificados no ano de 2014. Quanto ao modo de exploração da rede nos cenários a simular, é contemplado o modo de exploração normalmente operado pela empresa gestora, bem como diversas reconfigurações sobre o modo de exploração normalmente operado, realizadas através da abertura e fecho dos aparelhos de corte constituintes da rede. Em todos os cenários simulados, é realizado um estudo relativamente à potência de perdas do sistema, ao perfil da tensão nos diversos postos de transformação, e ao congestionamento de energia verificado nas linhas de distribuição da rede.
Resumo:
INTRODUCTION: A growing body of evidence shows the prognostic value of oxygen uptake efficiency slope (OUES), a cardiopulmonary exercise test (CPET) parameter derived from the logarithmic relationship between O(2) consumption (VO(2)) and minute ventilation (VE) in patients with chronic heart failure (CHF). OBJECTIVE: To evaluate the prognostic value of a new CPET parameter - peak oxygen uptake efficiency (POUE) - and to compare it with OUES in patients with CHF. METHODS: We prospectively studied 206 consecutive patients with stable CHF due to dilated cardiomyopathy - 153 male, aged 53.3±13.0 years, 35.4% of ischemic etiology, left ventricular ejection fraction 27.7±8.0%, 81.1% in sinus rhythm, 97.1% receiving ACE-Is or ARBs, 78.2% beta-blockers and 60.2% spironolactone - who performed a first maximal symptom-limited treadmill CPET, using the modified Bruce protocol. In 33% of patients an cardioverter-defibrillator (ICD) or cardiac resynchronization therapy device (CRT-D) was implanted during follow-up. Peak VO(2), percentage of predicted peak VO(2), VE/VCO(2) slope, OUES and POUE were analyzed. OUES was calculated using the formula VO(2) (l/min) = OUES (log(10)VE) + b. POUE was calculated as pVO(2) (l/min) / log(10)peakVE (l/min). Correlation coefficients between the studied parameters were obtained. The prognosis of each variable adjusted for age was evaluated through Cox proportional hazard models and R2 percent (R2%) and V index (V6) were used as measures of the predictive accuracy of events of each of these variables. Receiver operating characteristic (ROC) curves from logistic regression models were used to determine the cut-offs for OUES and POUE. RESULTS: pVO(2): 20.5±5.9; percentage of predicted peak VO(2): 68.6±18.2; VE/VCO(2) slope: 30.6±8.3; OUES: 1.85±0.61; POUE: 0.88±0.27. During a mean follow-up of 33.1±14.8 months, 45 (21.8%) patients died, 10 (4.9%) underwent urgent heart transplantation and in three patients (1.5%) a left ventricular assist device was implanted. All variables proved to be independent predictors of this combined event; however, VE/VCO2 slope was most strongly associated with events (HR 11.14). In this population, POUE was associated with a higher risk of events than OUES (HR 9.61 vs. 7.01), and was also a better predictor of events (R2: 28.91 vs. 22.37). CONCLUSION: POUE was more strongly associated with death, urgent heart transplantation and implantation of a left ventricular assist device and proved to be a better predictor of events than OUES. These results suggest that this new parameter can increase the prognostic value of CPET in patients with CHF.
Resumo:
A very important part of the globally produced energy is consumed in buildings, being an important share frequently used in the HVAC systems. These ones are increasing both in performance and in complexity, taking advantage from the use of the recent advances in mechanical and power electronic devices, particularly in the speed variation field. However the improved efficiency only occurs while the HVAC unit is working in the conditions specified by the manufacturer, otherwise the energy consumption raises to values considerably higher than the nominal ones. The adequate maintenance enforces the system to run on its nominal performance and the contrary has undesirable impact both in the performance and in the system expected life time. Therefore, HVAC field maintenance assumes a very important role in the global building sustainability concept. This work presents some results of an incorrect use of HVAC and the associated electric energy overconsumption that can assume values 50% higher than those that occur when the installation is operated according to the adequate maintenance plan.
Resumo:
In this paper, we apply the following four power indices to the Portuguese Parliament: Shapley–Shubik index, Banzhaf index, Deegan–Packel index and Public Good Index. We also present the main notions related with simple games and discuss the features of each power index by means of their axiomatic characterizations.
Resumo:
Smart Grids (SGs) have emerged as the new paradigm for power system operation and management, being designed to include large amounts of distributed energy resources. This new paradigm requires new Energy Resource Management (ERM) methodologies considering different operation strategies and the existence of new management players such as several types of aggregators. This paper proposes a methodology to facilitate the coalition between distributed generation units originating Virtual Power Players (VPP) considering a game theory approach. The proposed approach consists in the analysis of the classifications that were attributed by each VPP to the distributed generation units, as well as in the analysis of the previous established contracts by each player. The proposed classification model is based in fourteen parameters including technical, economical and behavioural ones. Depending of the VPP strategies, size and goals, each parameter has different importance. VPP can also manage other type of energy resources, like storage units, electric vehicles, demand response programs or even parts of the MV and LV distribution network. A case study with twelve VPPs with different characteristics and one hundred and fifty real distributed generation units is included in the paper.
Multi-criteria optimisation approach to increase the delivered power in radial distribution networks
Resumo:
This study proposes a new methodology to increase the power delivered to any load point in a radial distribution network, through the identification of new investments in order to improve the repair time. This research work is innovative and consists in proposing a full optimisation model based on mixed-integer non-linear programming considering the Pareto front technique. The goal is to achieve a reduction in repair times of the distribution networks components, while minimising the costs of that reduction as well as non-supplied energy costs. The optimisation model considers the distribution network technical constraints, the substation transformer taps, and it is able to choose the capacitor banks size. A case study based on a 33-bus distribution network is presented in order to illustrate in detail the application of the proposed methodology.
Resumo:
Proceedings of the 13th International UFZ-Deltares Conference on Sustainable Use and Management of Soil, Sediment and Water Resources - 9–12 June 2015 • Copenhagen, Denmark
Resumo:
The Internet of Things (IoT) has emerged as a paradigm over the last few years as a result of the tight integration of the computing and the physical world. The requirement of remote sensing makes low-power wireless sensor networks one of the key enabling technologies of IoT. These networks encompass several challenges, especially in communication and networking, due to their inherent constraints of low-power features, deployment in harsh and lossy environments, and limited computing and storage resources. The IPv6 Routing Protocol for Low Power and Lossy Networks (RPL) [1] was proposed by the IETF ROLL (Routing Over Low-power Lossy links) working group and is currently adopted as an IETF standard in the RFC 6550 since March 2012. Although RPL greatly satisfied the requirements of low-power and lossy sensor networks, several issues remain open for improvement and specification, in particular with respect to Quality of Service (QoS) guarantees and support for mobility. In this paper, we focus mainly on the RPL routing protocol. We propose some enhancements to the standard specification in order to provide QoS guarantees for static as well as mobile LLNs. For this purpose, we propose OF-FL (Objective Function based on Fuzzy Logic), a new objective function that overcomes the limitations of the standardized objective functions that were designed for RPL by considering important link and node metrics, namely end-to-end delay, number of hops, ETX (Expected transmission count) and LQL (Link Quality Level). In addition, we present the design of Co-RPL, an extension to RPL based on the corona mechanism that supports mobility in order to overcome the problem of slow reactivity to frequent topology changes and thus providing a better quality of service mainly in dynamic networks application. Performance evaluation results show that both OF-FL and Co-RPL allow a great improvement when compared to the standard specification, mainly in terms of packet loss ratio and average network latency. 2015 Elsevier B.V. Al
Resumo:
Transformers may be classified according to dielectric insulation material as follows: • Oil-filled transformers • Dry type transformers
Resumo:
Cada vez mais a indústria tem vindo a sofrer algumas mudanças no seu processo produtivo. Hoje, mais que nunca, é preciso garantir que as instalações produtivas sejam as mais eficientes possíveis, procurando a racionalização da energia com um decrescimento dos custos. Deste modo o objectivo desta dissertação é o diagnóstico energético na fábrica de pneus e sugestões de melhoria na empresa CNB/CAMAC. A realização de um diagnóstico energético, para a detecção de desperdícios de energia tem sido amplamente utilizada. A optimização irá prospectar potenciais de mudanças e aplicação de tecnologias de eficiência energética. Pretende-se deste modo travar o consumo energético sem que seja afectada a produção, já que a empresa é considerada consumidora intensiva de energia. Na empresa CNB/CAMAC há consumo de fuelóleo, gasóleo, vapor e energia eléctrica, sendo o vapor a forma de energia mais consumida (36,1%) seguido da energia eléctrica (33,8%), fuelóleo (29,9) e gasóleo (0,3%). O levantamento energético permitiu estudar a influência de algumas variáveis, nos consumos anuais da energia, e assim apresentar propostas de melhoria. Uma das propostas analisadas foi a possibilidade de efectuar um isolamento térmico a algumas válvulas no equipamento de produção e distribuição de vapor. Este isolamento conduziria a uma poupança de 33.540 kWh/ano. Também se propôs o isolamento dos tubos de transporte de vapor no sector da vulcanização o que geraria uma poupança de 549.826 kWh/ano. Sugere-se a implementação de um economizador na caldeira nº1 uma vez que a temperatura média dos gases de chaminé se situa á volta dos 311ºC. Uma vez que existe a pré instalação de um sistema de cogeração, sugere-se que este seja finalizado. Propôs-se a implementação de balastros electrónicos, que conduziria a uma diminuição em energia eléctrica de 33.5877 kWh/ano. Também se propõe a eliminação das fugas de ar na rede de distribuição do ar comprimido poupando assim 12,96kW/h.