934 resultados para Portata cardiaca, Fick, termodiluizione, Cardiac output, Indicatore, Pazienti
Resumo:
It has been argued that the variation in brain activity that occurs when observing another person reflects a representation of actions that is indivisible, and which plays out in full once the intent of the actor can be discerned. We used transcranial magnetic stimulation to probe the excitability of corticospinal projections to 2 intrinsic hand muscles while motions to reach and grasp an object were observed. A symbolic cue either faithfully indicated the required final orientation of the object and thus the nature of the grasp that was required, or was in conflict with the movement subsequently displayed. When the cue was veridical, modulation of excitability was in accordance with the functional role of the muscles in the action observed. If however the cue had indicated that the alternative grasp would be required, modulation of output to first dorsal interosseus was consistent with the action specified, rather than the action observed-until the terminal phase of the motion sequence during which the object was seen lifted. Modulation of corticospinal output during observation is thus segmented-it progresses initially in accordance with the action anticipated, and if discrepancies are revealed by visual input, coincides thereafter with that of the action seen.
Resumo:
Aims
Our aim was to test the prediction and clinical applicability of high-sensitivity assayed troponin I for incident cardiovascular events in a general middle-aged European population.
Methods and results
High-sensitivity assayed troponin I was measured in the Scottish Heart Health Extended Cohort (n = 15 340) with 2171 cardiovascular events (including acute coronary heart disease and probable ischaemic strokes), 714 coronary deaths (25% of all deaths), 1980 myocardial infarctions, and 797 strokes of all kinds during an average of 20 years follow-up. Detection rate above the limit of detection (LoD) was 74.8% in the overall population and 82.6% in men and 67.0% in women. Troponin I assayed by the high-sensitivity method was associated with future cardiovascular risk after full adjustment such as that individuals in the fourth category had 2.5 times the risk compared with those without detectable troponin I (P < 0.0001). These associations remained significant even for those individuals in whom levels of contemporary-sensitivity troponin I measures were not detectable. Addition of troponin I levels to clinical variables led to significant increases in risk prediction with significant improvement of the c-statistic (P < 0.0001) and net reclassification (P < 0.0001). A threshold of 4.7 pg/mL in women and 7.0 pg/mL in men is suggested to detect individuals at high risk for future cardiovascular events.
Conclusion
Troponin I, measured with a high-sensitivity assay, is an independent predictor of cardiovascular events and might support selection of at risk individuals.
Resumo:
Background: There is a need to improve the effectiveness of strategies to help cardiac rehabilitation patients achieve recommended levels of physical activity; the use of pedometers requires further research. We aimed to examine the feasibility of a randomised controlled trial, of an intervention using pedometer step-count goals, to promote physical activity for cardiac rehabilitation patients. Methods: We invited patients who completed a supervised cardiac rehabilitation programme to participate in this community-based study. Consenting participants wore a Yamax CW-701 pedometer for one week, blinded to stepcount readings, before being randomly allocated to groups. Intervention groups were told their step-counts; working with a clinical facilitator (nurse or physiotherapist) individually, they set daily step-count goals and reviewed these weekly. Baseline step-counts were hidden from controls, who were not given pedometers but received ongoing weekly facilitator support. After six weeks both groups wore ‘blinded’ pedometers for outcome assessment and participated in semi-structured interviews which explored their experiences of the study. Outcomes included rates of uptake, adherence and completion of measures, including step-counts, quality of life (EQ-5D) and stage of behaviour change. Results: Four programme groups were recruited; two received the intervention. Of 68 invitees, 45 participated (66%) (19 intervention; 26 control). Forty-two (93%) completed the outcomes. Baseline characteristics were comparable between groups. Mean steps/day increased more for intervention participants (2,742; 95%CI 1,169 to 4,315) than controls (-42; 95%CI -1,102 to 1,017) (p=0.004). The intervention and on-going clinical contact were welcomed; participants considered that step-counts, compared to time-related targets, encouraged them to become more active. Conclusion: These findings suggest that an intervention using individually tailored step-count goals may help increase and sustain physical activity following a cardiac rehabilitation programme. A definitive randomised controlled trial using blinded outcome measurements is feasible and of potential value in determining how best to translate physical activity advice into practice.
Resumo:
This study aims to evaluate the use of Varian radiotherapy dynamic treatment log (DynaLog) files to verify IMRT plan delivery as part of a routine quality assurance procedure. Delivery accuracy in terms of machine performance was quantified by multileaf collimator (MLC) position errors and fluence delivery accuracy for patients receiving intensity modulated radiation therapy (IMRT) treatment. The relationship between machine performance and plan complexity, quantified by the modulation complexity score (MCS) was also investigated. Actual MLC positions and delivered fraction of monitor units (MU), recorded every 50 ms during IMRT delivery, were extracted from the DynaLog files. The planned MLC positions and fractional MU were taken from the record and verify system MLC control file. Planned and delivered beam data were compared to determine leaf position errors with and without the overshoot effect. Analysis was also performed on planned and actual fluence maps reconstructed from the MLC control file and delivered treatment log files respectively. This analysis was performed for all treatment fractions for 5 prostate, 5 prostate and pelvic node (PPN) and 5 head and neck (H&N) IMRT plans, totalling 82 IMRT fields in ∼5500 DynaLog files. The root mean square (RMS) leaf position errors without the overshoot effect were 0.09, 0.26, 0.19 mm for the prostate, PPN and H&N plans respectively, which increased to 0.30, 0.39 and 0.30 mm when the overshoot effect was considered. Average errors were not affected by the overshoot effect and were 0.05, 0.13 and 0.17 mm for prostate, PPN and H&N plans respectively. The percentage of pixels passing fluence map gamma analysis at 3%/3 mm was 99.94 ± 0.25%, which reduced to 91.62 ± 11.39% at 1%/1 mm criterion. Leaf position errors, but not gamma passing rate, were directly related to plan complexity as determined by the MCS. Site specific confidence intervals for average leaf position errors were set at -0.03-0.12 mm for prostate and -0.02-0.28 mm for more complex PPN and H&N plans. For all treatment sites confidence intervals for RMS errors with the overshoot was set at 0-0.50 mm and for the percentage of pixels passing a gamma analysis at 1%/1 mm a confidence interval of 68.83% was set also for all treatment sites. This work demonstrates the successful implementation of treatment log files to validate IMRT deliveries and how dynamic log files can diagnose delivery errors not possible with phantom based QC. Machine performance was found to be directly related to plan complexity but this is not the dominant determinant of delivery accuracy.
Resumo:
This paper investigates the construction of linear-in-the-parameters (LITP) models for multi-output regression problems. Most existing stepwise forward algorithms choose the regressor terms one by one, each time maximizing the model error reduction ratio. The drawback is that such procedures cannot guarantee a sparse model, especially under highly noisy learning conditions. The main objective of this paper is to improve the sparsity and generalization capability of a model for multi-output regression problems, while reducing the computational complexity. This is achieved by proposing a novel multi-output two-stage locally regularized model construction (MTLRMC) method using the extreme learning machine (ELM). In this new algorithm, the nonlinear parameters in each term, such as the width of the Gaussian function and the power of a polynomial term, are firstly determined by the ELM. An initial multi-output LITP model is then generated according to the termination criteria in the first stage. The significance of each selected regressor is checked and the insignificant ones are replaced at the second stage. The proposed method can produce an optimized compact model by using the regularized parameters. Further, to reduce the computational complexity, a proper regression context is used to allow fast implementation of the proposed method. Simulation results confirm the effectiveness of the proposed technique. © 2013 Elsevier B.V.
Resumo:
An algorithm based only on the impedance cardiogram (ICG) recorded through two defibrillation pads, using the strongest frequency component and amplitude, incorporated into a defibrillator could determine circulatory arrest and reduce delays in starting cardiopulmonary resuscitation (CPR). Frequency analysis of the ICG signal is carried out by integer filters on a sample by sample basis. They are simpler, lighter and more versatile when compared to the FFT. This alternative approach, although less accurate, is preferred due to the limited processing capacity of devices that could compromise real time usability of the FFT. These two techniques were compared across a data set comprising 13 cases of cardiac arrest and 6 normal controls. The best filters were refined on this training set and an algorithm for the detection of cardiac arrest was trained on a wider data set. The algorithm was finally tested on a validation set. The ICG was recorded in 132 cardiac arrest patients (53 training, 79 validation) and 97 controls (47 training, 50 validation): the diagnostic algorithm indicated cardiac arrest with a sensitivity of 81.1% (77.6-84.3) and specificity of 97.1% (96.7-97.4) for the validation set (95% confidence intervals). Automated defibrillators with integrated ICG analysis have the potential to improve emergency care by lay persons enabling more rapid and appropriate initiation of CPR and when combined with ECG analysis they could improve on the detection of cardiac arrest.
Resumo:
Power dissipation and robustness to process variation have conflicting design requirements. Scaling of voltage is associated with larger variations, while Vdd upscaling or transistor upsizing for parametric-delay variation tolerance can be detrimental for power dissipation. However, for a class of signal-processing systems, effective tradeoff can be achieved between Vdd scaling, variation tolerance, and output quality. In this paper, we develop a novel low-power variation-tolerant algorithm/architecture for color interpolation that allows a graceful degradation in the peak-signal-to-noise ratio (PSNR) under aggressive voltage scaling as well as extreme process variations. This feature is achieved by exploiting the fact that all computations used in interpolating the pixel values do not equally contribute to PSNR improvement. In the presence of Vdd scaling and process variations, the architecture ensures that only the less important computations are affected by delay failures. We also propose a different sliding-window size than the conventional one to improve interpolation performance by a factor of two with negligible overhead. Simulation results show that, even at a scaled voltage of 77% of nominal value, our design provides reasonable image PSNR with 40% power savings. © 2006 IEEE.
Resumo:
Power dissipation and tolerance to process variations pose conflicting design requirements. Scaling of voltage is associated with larger variations, while Vdd upscaling or transistor up-sizing for process tolerance can be detrimental for power dissipation. However, for certain signal processing systems such as those used in color image processing, we noted that effective trade-offs can be achieved between Vdd scaling, process tolerance and "output quality". In this paper we demonstrate how these tradeoffs can be effectively utilized in the development of novel low-power variation tolerant architectures for color interpolation. The proposed architecture supports a graceful degradation in the PSNR (Peak Signal to Noise Ratio) under aggressive voltage scaling as well as extreme process variations in. sub-70nm technologies. This is achieved by exploiting the fact that some computations are more important and contribute more to the PSNR improvement compared to the others. The computations are mapped to the hardware in such a way that only the less important computations are affected by Vdd-scaling and process variations. Simulation results show that even at a scaled voltage of 60% of nominal Vdd value, our design provides reasonable image PSNR with 69% power savings.
Resumo:
Introduction: Streptococcus bovis can lead to bacteraemia, septicaemia, and ultimately endocarditis. The objective of this study was to evaluate the long-term implications of S. bovis endocarditis on cardiac morbidity and mortality.
Methods: A retrospective cohort study was performed between January 2000 and March 2009 to assess all patients diagnosed with S. bovis bacteraemia from the Belfast Health and Social Care Trust. The primary end-point for cardiac investigations was the presence of endocarditis. Secondary end-points included referral for cardiac surgery and overall mortality.
Results: Sixty-one positive S. bovis blood cultures from 43 patients were included. Following echocardiography, seven patients were diagnosed with infective endocarditis (16.3 % of total patients); four patients (9.3 %) had native valve involvement while three (7.0 %) had prosthetic valve infection. Five of these seven patients had more than one positive S. bovis culture (71.4 %). Three had significant valve dysfunction that warranted surgical repair/replacement, one of whom was unfit for surgery. There was a 100 % recurrence rate amongst the valve replacement patients (n = 2) and six patients with endocarditis had colorectal pathology. Patients with endocarditis had similar long-term survival as those with non-endocarditic bacteraemia (57.1 % alive vs. 50 % of non-endocarditis patients, p = 0.73).
Conclusion: Streptococcus bovis endocarditis patients tended to have pre-existing valvular heart disease and those with prosthetic heart valves had higher surgical intervention and relapse rates. These patients experienced a higher rate of co-existing colorectal pathology but currently have reasonable long-term outcomes. This may suggest that they represent a patient population that merits consideration for an early surgical strategy to maximise long-term results, however, further evaluation is warranted. © 2013 The Japanese Association for Thoracic Surgery.
Resumo:
The light output from nominally smooth Al-Ox-Au tunnel junctions is observed to be substantially independent of the deposition rate of the Au film electrode. Films deposited quickly (2 nm s-1) and those deposited slowly (0.16 nm s-1) have similar spectral dependences and intensities. (This is in contrast to roughened films where those deposited quickly give out less light, especially towards the blue end of the spectrum.) The behaviour can be interpreted in terms of the ratio l(ph)/l(em) where l(ph) and l(em) are the mean free paths of surface plasmons between external photon emissions and internal electromagnetic absorptions respectively. Once l(ph)/l(em) exceeds 100, as it does on smooth films, grain size has little further effect on the spectral shape of the light output. In fast-deposited films there are two compensating effects on the output intensity: grain boundary scattering decreases it and greater surface roughness increases it.
Resumo:
BACKGROUND: Family-based cardiac screening programmes for persons at risk for genetic cardiac diseases are now recommended. However, the psychological wellbeing and health related quality of life (QoL) of such screened patients is poorly understood, especially in younger patients. We sought to examine wellbeing and QoL in a representative group of adults aged 16 and over in a dedicated family cardiac screening clinic.
METHODS: Prospective survey of consecutive consenting patients attending a cardiac screening clinic, over a 12 month period. Data were collected using two health measurement tools: the Short Form 12 (version 2) and the Hospital Anxiety and Depression Scale (HADS), along with baseline demographic and screening visit-related data. The HADS and SF-12v.2 outcomes were compared by age group. Associations with a higher HADS score were examined using logistic regression, with multi-level modelling used to account for the family-based structure of the data.
RESULTS: There was a study response rate of 86.6%, with n=334 patients providing valid HADS data (valid response rate 79.5%), and data on n=316 retained for analysis. One-fifth of patients were aged under 25 (n=61). Younger patients were less likely than older to describe significant depression on their HADS scale (p<0.0001), although there were overall no difference between the prevalence of a significant HADS score between the younger and older age groups (18.0% vs 20.0%, p=0.73). Significant positive associates of a higher HADS score were having lower educational attainment, being single or separated, and being closely related to the family proband. Between-family variance in anxiety and depression scores was greater than within-family variance.
CONCLUSIONS: High levels of anxiety were seen amongst patients attending a family-based cardiac screening clinic.Younger patients also had high rates of clinically significant anxiety. Higher levels of anxiety and depression tends to run in families, and this has implications for family screening and intervention programmes.