971 resultados para Portal vein thrombosis
Resumo:
Synergism between low-molecular-weight heparin and low doses of unfractionated heparin (UH) enhancing anti-factor Xa activity and the release of tissue factor pathway inhibitor was observed. The aim of this study was to verify whether this association is effective in preventing experimental venous thrombosis. Seventy rats were allocated into 7 groups: the control group treated with distilled water, the H-350 group treated with UH 350 IU/kg, the E-2 group treated with enoxaparin 2 mg/kg, the H-175 group treated with UH 175 IU/kg, the E-1 group treated with enoxaparin 1 mg/kg, the H-175 + E-1 group treated with UH 175 IU/kg plus enoxaparin 1 mg/kg, and the H-100 + E-0.5 group treated with UH 100 IU/kg plus enoxaparin 0.5 mg/kg. Forty minutes after subcutaneous injection, thrombosis was induced in vena cava. Three hours later, if present, thrombi were withdrawn and weighed. Bleeding time, activated partial thromboplastin time, thrombin time (TT), and anti-factor Xa were measured at the beginning and end of the experiment. Fortyeight other animals were treated, but without inducing thrombus, and tests were performed 40 min after injection. Thrombus developed in 90.9% of control animals, 20% of the H-350 group, 22.2% of the E-2 group, 10% of the H-175 + E-1 group, and 30% of the H-100 + E-0.5 group; there was a difference between group C and the other groups. Only in the H-350 and H-175 + E-1 groups were TT and activated partial thromboplastin time prolonged in relation to control at the end of the experiment. Forty minutes after injection, TT was prolonged in the H-350 and H-175 + E-1 groups. In conclusion, combinations of low doses of low-molecular-weight heparin and low doses of UH were as effective as high doses of each one used alone in preventing thrombus development in rat vena cava. Copyright (c) 2005 S. Karger AG, Basel.
Resumo:
Aim. One of the major causes of chronic venous disease is venous reflux, the identification and quantification of which are important for diagnosis. Duplex scanning allows for the detection and quantification of reflux in individual veins. Evaluation of the great saphenous vein in primary varicosis is necessary for its preservation. Objective of the study is to evaluate a possible correlation between the intensity of reflux at the saphenofemoral junction, diameter alterations of the incompetent great saphenous vein and the practical effect of such correlation. Also to compare the clinical severity of the CEAP classification with such parameters.Methods. Three hundred limbs were submitted to duplex evaluation of their insufficient saphenous veins. Vein diameter was measured on five different points. Velocity and flow at reflux peak and reflux time were determined. The saphenous vein's diameters were correlated with velocity, flow and time. The three latter parameters and diameters were compared with clinical severity according to CEAP.Results. Correlation was found between the saphenous vein's diameters, velocity and flow. No correlation was observed between time and diameter in the thigh's upper and middle thirds. When comparing diameter, velocity and flow with CEAP clinical severity classification, an association was observed. The correlation between reflux time with clinical severity was weak.Conclusion. Reflux time is a good parameter for identifying the presence of reflux, but not for quantifying it. Velocity and peak flow were better parameters for evaluating reflux intensity as they were correlated with great saphenous vein alterations, and were associated with the disease's clinical severity. [Int Angiol 2010;29:323-30]
Resumo:
Superficial nerve injuries are very common during varicose vein surgery. In contrast, deep nerve injuries are rare and reported especially when surgery involves the small saphenous vein (SSV). The deep motor nerves most commonly injured are the tibial nerve and the peroneal nerve, which are directly or indirectly affected by extrinsic compression, stretching, or healing process involvement. In this report, two cases of common fibular nerve injury after SSV stripping are described, including treatment used and patient outcomes. Nerve damage mechanisms, anatomy, and prevention strategies are also discussed. In conclusion, fibular nerve damage may occur during SSV stripping. Preventive measures include careful preoperative ultrasonographic investigation of the anatomy of the vein, determining location of the saphenopopliteal joint, and careful dissection far from fibular nerve and restricted to the popliteal fossa.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
The venom of Lonomia obliqua caterpillar may induce a hemorrhagic syndrome in humans, and blood incoagulability by afibrinogenemia when intravenously injected in laboratory animals. The possible antithrombotic and thrombolytic activities of L. obliqua caterpillar bristle extract (LOCBE) were evaluated in this study. The minimal intravenous dose of the extract necessary to induce afibrinogenemia and anticoagulation was 3.0 and 10.0 µg protein/kg body weight for rabbits and rats, respectively. In rabbits, this dose induced total blood incoagulability for at least 10 h and did not reduce the weight of preformed venous thrombi, in contrast to streptokinase (30,000 IU/kg). In rats, pretreatment with 5.0 and 10.0 µg/kg LOCBE prevented the formation of thrombi induced by venous stasis or by injury to the venous endothelium. The dose of 5.0 µg/kg LOCBE did not modify blood coagulation assay parameters but increased bleeding time and decreased plasma factor XIII concentration. When the extract was administered to rats at the dose of 10.0 µg/kg, the blood was totally incoagulable for 6 h. These data show that LOCBE was effective in preventing experimental venous thrombosis in rats, justifying further studies using purified fractions of the extract to clarify the mechanisms of this effect.
Resumo:
O emprego da trombectomia na angioplastia primária demonstra bons resultados clínicos e angiográficos imediatos, por meio de redução da embolização distal e do fenômeno do no-reflow e otimização da perfusão miocárdica. Essa técnica, principalmente usada em artérias coronárias, em raras oportunidades é descrita quando empregada em pontes de safena aortocoronarianas. Relatamos o caso de um paciente de 67 anos com infarto agudo do miocárdio relacionado a oclusão de ponte de safena e submetido a trombectomia com bons resultados.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Although veins and arteries present similar wall structures, there are differences which may be relevant in peripheral nerve reconstruction. Inside-out vein grafts (IOVG) have been satisfactorily used to repair both motor and sensitive nerves. However, the inside-out artery graft (IOAG) is a new technique and not fully investigated. Our study presents comparative morphological data on nerve regeneration achieved with IOVG and IOAG in the repair of Wistar rat sciatic nerves. Jugular veins and aorta arteries were harvested from donor animals and used inside-out to bridge a 10-mm gap. Animals were sacrificed at 10 weeks to evaluate nerve regeneration. Both techniques presented great variability in nervous tissue, though some animals showed satisfactory results. Different intensities of scarring processes might have interfered with nerve regeneration. Although IOVG and IOAG techniques showed similar morphometric results, in general, IOVG presented a closer-to-normal nerve organization than IOAG.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
In this paper we search for the dynamics of a simple portal structure in the free and in the periodic excitation cases. By using the Center Manifold approach and Averaging Method, we obtain results on both stability and bifurcation of equilibrium points and periodic orbits. (C) 2005 Elsevier Ltd. All rights reserved.
Resumo:
In this paper, we examine the nonlinear control method based on the saturation phenomenon and of systems coupled with quadratic nonlinear ties applied to a shear-building portal plane frame foundation that supports an unbalanced direct cut-rent with limited power supply (non-ideal system). We analyze the equations of motion by using the method of averaging and numerical simulation. The interaction of the non-ideal structure with the saturation controller may lead to the occurrence of interesting phenomena during the forward passage through the several resonance states of the systems. Special attention is focused on passage through resonance when the non-ideal excitation frequency is near the portal frame natural frequency and when the non-ideal system frequency is approximately twice the controller frequency (two-to-one internal resonance).
Resumo:
A practical problem of synchronization of a non-ideal (i.e. when the excitation is influenced by the response of the system) and non-linear vibrating system was posed and investigated by means of numerical simulations. Two rotating unbalanced motors compose the mathematical model considered here with limited power supply mounted on the horizontal beam of a simple portal frame. As a starting point, the problem is reduced to a four-degrees-of-freedom model and its equations of motion, derived elsewhere via a Lagrangian approach, are presented. The numerical results show the expected phenomena associated with the passage through resonance with limited power. Further, for a two-to-one relationship between the frequencies associated with the first symmetric mode and the sway mode, by using the variation of torque constants, the control of the self-synchronization and synchronization (in the system) are observed at certain levels of excitations.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
CONTEXTO: O esvaziamento cervical que acompanha a ressecção da lesão primária no tratamento dos tumores malignos das vias aerodigestivas superiores possibilita o surgimento de complicações inerentes a ela ou ao prolongamento do tempo cirúrgico, aumentando os riscos para o paciente. Entre as complicações que podem ocorrer está a amaurose, de incidência rara. RELATO do CASO: Um paciente submetido a laringectomia total e esvaziamento cervical seletivo à esquerda e radical modificado à direita, que evoluiu com amaurose, provavelmente decorrente de hipotensão intra-operatória, com contribuição dos Diabetes Mellitus descompensado e trombose da veia jugular interna à direita. Discutem as possíveis causas, os fatores de risco e os cuidados que devem ser tomados para evitar essa rara, mas tão debilitante complicação.