975 resultados para Orthopedic implants
Resumo:
The use of cervical manipulation presents concerns because of a risk of devastating side effects of trauma to the vertebral artery. Little is known about the frequency of use of cervical manipulation versus passive mobilisation by physiotherapists. A recent national, multi-centre randomised clinical trial of the physiotherapy management of cervicogenic headache provided an opportunity to gain an insight into practices of a sample of manipulative physiotherapists across Australia. The treatment records for the 100 subjects who received only manipulative therapy, or manipulative therapy with exercise as per the trial protocol, were audited. The results revealed that cervical manipulation was used in 20.2% of the 1090 treatments provided to these subjects but cervical joint mobilisation only was used in the vast majority of treatments (77.6%). Nevertheless, 42% of subjects were treated with cervical manipulation at some time. In most instances, manipulation was accompanied by passive mobilisation in the same treatment session. Patients were manipulated on one to six occasions and this occurred predominantly in the latter half of the 12-treatment program. Cervical manipulation was used less frequently in the group who also received exercise. The data suggest that the physiotherapists participating in this study used cervical manipulation selectively and relatively conservatively considering the high use of cervical mobilisation techniques. This may reflect their due regard to safety in the treatment of the cervical region.
Resumo:
Objective: First, to assess the clinical effectiveness of hylan G-F 20 in an appropriate care treatment regimen (as defined by the American College of Rheumatology (ACR) 1995 guidelines) as measured by validated disease-specific outcomes and health-related quality of life endpoints for patients with osteoarthritis (OA) of the knee. Second, to utilize the measures of effectiveness and costs in an economic evaluation (see accompanying manuscript). Design: A total of 255 patients with OA of the knee were enrolled by rheumatologists or orthopedic surgeons into a prospective, randomized, open-label, 1-year, multi-centred trial, conducted in Canada. Patients were randomized to 'Appropriate care with hylan G-F 20' (AC+H) or 'Appropriate care without hylan G-F 20' (AC). Data were collected at clinic visits (baseline, 12 months) and by telephone (1, 2, 4, 6, 8, 10, and 12 months). Results: The AC+H group was superior to the AC group for all primary (% reduction in mean Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) pain scale: 38% vs 13%, P=0.0001) and secondary effectiveness outcome measures. These differences were all statistically significant and exceeded the 20% difference between groups seta priori by the investigators as the minimum clinically important difference. Health-related quality of life improvements in the AC+H group were statistically superior for the WOMAC pain, stiffness and physical function (all P
Resumo:
Spheres of different types of material are used for the replacement of lost volume after removal of the eye bulb or its content to prevent contraction of the orbital cavity. The aim of this study was to evaluate the scope of polymethylmethacrylate (PMMA) used as intraocular implant in eviscerated rabbit eye. Twelve New Zealand rabbits underwent unilateral evisceration of the left eye, with subsequent implantation of PMMA sphere 12 mm in diameter. Clinical evaluation was performed daily during the first 15 days after surgery and every 15 days until the end of the study period (180 days). For the histopathological analysis, three animals per trial underwent enucleation at 15, 45, 90 and 180 days after evisceration. There was no wound dehiscence, signs of infection or implant extrusion in any animal throughout the study period. Histological examination revealed the formation of fibrovascular tissue around the implants. The PMMA behaved as inert and non-integrable.
Resumo:
Thermal degradation of as electrospun chitosan membranes and samples subsequently treated with ethanol and cross-linked with glutaraldehyde (GA) have been studied by thermogravimetry (TG) coupled with an infrared spectrometer (FTIR). The influence of the electrospinning process and cross-linking in the electrospun chitosan thermal stability was evaluated. Up to three degradation steps were observed in the TG data, corresponding to water dehydration reaction at temperatures below 100 ºC, loss of side groups formed between the amine groups of chitosan and trifluoroacetic acid between 150 – 270 ºC and chitosan thermal degradation that starts around 250 ºC and goes up to 400 ºC. The Kissinger model was employed to evaluate the activation energies of the electrospun membranes during isothermal experiments and revealed that thermal degradation activation energy increases for the samples processed by electrospinning and subsequent neutralization and cross-linking treatments with respect to the neat chitosan powder.
Resumo:
Nowadays, different techniques are available for manufacturing full-arch implant-supported prosthesis, many of them based on an impression procedure. Nevertheless, the long-term success of the prosthesis is highly influenced by the accuracy during such process, being affected by factors such as the impression material, implant position, angulation and depth. This paper investigates the feasibility of a 3D electromagnetic motion tracking system as an acquisition method for modeling such prosthesis. To this extent, we propose an implant acquisition method at the patient mouth, using a specific prototyped tool coupled with a tracker sensor, and a set of calibration procedures (for distortion correction and tool calibration), that ultimately obtains combined measurements of the implant’s position and angulation, and eliminating the use of any impression material. However, in the particular case of the evaluated tracking system, the order of magnitude of the obtained errors invalidates its use for this specific application.
Electromagnetic tracker feasibility in the design of a dental superstructure for edentulous patients
Resumo:
The success of the osseointegration concept and the Brånemark protocol is highly associated to the accuracy in the production of an implant-supported prosthesis. One of most critical steps for long-term success of these prosthesis is the accuracy obtained during the impression procedure, which is affected by factors such as the impression material, implant position, angulation and depth. This paper investigates the feasibility of 3D electromagnetic motion tracking systems as an acquisition method for modeling full-arch implant-supported prosthesis. To this extent, we propose an implant acquisition method at the patient mouth and a calibration procedure, based on a 3D electromagnetic tracker that obtains combined measurements of implant’s position and angulation, eliminating the use of any impression material. Three calibration algorithms (namely linear interpolation, higher-order polynomial and Hardy multiquadric) were tested to compensate for the electromagnetic tracker distortions introduced by the presence of nearby metals. Moreover, implants from different suppliers were also tested to study its impact on tracking accuracy. The calibration methodology and the algorithms employed proved to implement a suitable strategy for the evaluation of novel dental impression techniques. However, in the particular case of the evaluated electromagnetic tracking system, the order of magnitude of the obtained errors invalidates its use for the full-arch modeling of implant-supported prosthesis.
Resumo:
The success of dental implant-supported prosthesis is directly linked to the accuracy obtained during implant’s pose estimation (position and orientation). Although traditional impression techniques and recent digital acquisition methods are acceptably accurate, a simultaneously fast, accurate and operator-independent methodology is still lacking. Hereto, an image-based framework is proposed to estimate the patient-specific implant’s pose using cone-beam computed tomography (CBCT) and prior knowledge of implanted model. The pose estimation is accomplished in a threestep approach: (1) a region-of-interest is extracted from the CBCT data using 2 operator-defined points at the implant’s main axis; (2) a simulated CBCT volume of the known implanted model is generated through Feldkamp-Davis-Kress reconstruction and coarsely aligned to the defined axis; and (3) a voxel-based rigid registration is performed to optimally align both patient and simulated CBCT data, extracting the implant’s pose from the optimal transformation. Three experiments were performed to evaluate the framework: (1) an in silico study using 48 implants distributed through 12 tridimensional synthetic mandibular models; (2) an in vitro study using an artificial mandible with 2 dental implants acquired with an i-CAT system; and (3) two clinical case studies. The results shown positional errors of 67±34μm and 108μm, and angular misfits of 0.15±0.08º and 1.4º, for experiment 1 and 2, respectively. Moreover, in experiment 3, visual assessment of clinical data results shown a coherent alignment of the reference implant. Overall, a novel image-based framework for implants’ pose estimation from CBCT data was proposed, showing accurate results in agreement with dental prosthesis modelling requirements.
Resumo:
Cerebral vascular disease is the primary cause of permanent disability in Portugal. Impaired stability is considered an important feature after stroke as it is related with higher risk of falls and functional dependence. Physiotherapy intervention usually starts early after stroke in order to direct motor recovery and help patients to improve their ability to perform activities of daily living (ADL). Purpose: to investigate the relationship of balance to functionality in acute stroke patients. Methods: 16 subjects (8 women and 8 men), mean age 63,62 ± 2,16y, with unilateral ischemic stroke in the middle cerebral artery territory, who were admitted to physiotherapy department of Fernando Fonseca Hospital in Portugal, within the first month after stroke were recruited to participate in this study. All subjects have no cognitive impairment according to Mini Mental State, no history of lower extremity orthopedic problems and no other disease that could interfere with treatments. All patients gave their inform consent to participate in this study. Subjects were assessed with the Modified Barthel Index (MBI) and the Berg Balance Scale (BBS).
Resumo:
Purpose/Objective: The purpose of this work was to determine biologically equivalent alternative regimens for the treatment of prostate cancer using External Beam Radiotherapy (EBRT) and Low Dose-Rate Brachytherapy (LDRBT) with 125I implants and to evaluate the sensitivity of these regimens to different sets of radiobiological parameters of the Linear-Quadratic (LQ) model.
Resumo:
The aim of the present work was to investigate the wetting behaviour of biomedical grade Ti-6Al-4V alloy surfaces textured by a femtosecond laser treatment. The material was treated in ambient atmosphere using an Yb: KYW chirped-pulse-regenerative amplification laser with a wavelength of 1030 nm and a pulse duration of 500 fs. Four main types of surface textures were obtained depending on the processing parameters and laser treatment method. These textures consist of: (1) nanoscale laser-induced periodic surface structures (LIPSS); (2) nanopillars; (3) a bimodal roughness distribution texture formed of LIPSS overlapping microcolumns; (4) a complex texture formed of LIPSS overlapping microcolumns with a periodic variation of the columns size in the laser scanning direction. The wettability of the surfaces was evaluated by the sessile drop method using distilled-deionized (DD) water and Hank's balanced salt solution (HBSS) as testing liquids. The laser treated surfaces present a hydrophilic behaviour as well as a high affinity for the saline solution, with equilibrium contact angles in the ranges 24.1-76.2. for DD water and 8.4-61.8. for HBSS. The wetting behaviour is anisotropic, reflecting the anisotropy of the surface textures. (c) 2012 Elsevier B.V. All rights reserved.
Resumo:
Introdução: Não existe um consenso quanto ao melhor tratamento para a radiculopatia cervical pois existe uma grande variedade de manifestações clínicas e opções terapêuticas, mas a sua selecção vai depender do caso particular do utente, sugerindo assim uma correcta avaliação do Fisioterapeuta. Objectivo: Este estudo pretende descrever e avaliar a efectividade de um programa de Fisioterapia num caso de radiculopatia cervical, na dor, funcionalidade e percepção da qualidade de vida. Participantes e Métodos: Estudo observacional descritivo tipo estudo de caso de um utente de 56 anos de idade, com radiculopatia cervical. Para a avaliação foram utilizados testes ortopédicos, a escala visual analógica e os questionários de incapacidade funcional da cervical e do membro superior bem como da percepção da qualidade de vida. Estes questionários foram aplicados em 3 momentos, antes da intervenção, no final e após 6 semanas e os restantes instrumentos foram utilizados em diversos momentos ao longo da intervenção. Esta foi efectuada duas vezes por semana, ao longo de 10 semanas recorrendo a técnicas de terapia manual, exercícios de controlo motor e educação do utente. Resultados: Verificou-se que a dor na cervical passou de 6,5 para 2/10 EVA e no cotovelo direito de 7,3 para 2/10. A resposta ao questionário de incapacidade funcional na cervical variou de 40% no primeiro momento para 11,1% no segundo, o da incapacidade funcional do membro superior variou de 63,6% para 33,5% e o questionário da percepção da qualidade de vida variou de 55,01 para 68,69. Seis semanas após a intervenção, todos estes resultados se mantinham praticamente inalterados. Conclusão: Este caso permitiu demonstrar o processo de raciocínio clínico efectuado ao longo de dez semanas de intervenção em que se utilizou uma abordagem centrada no utente, baseada na evidência científica e na experiência clínica anterior. Os resultados alcançados foram de encontro às expectativas iniciais e parecem evidenciar que, neste caso, o programa de fisioterapia teve efeitos positivos na dor, funcionalidade e percepção da qualidade de vida.
Resumo:
Introdução: Existem diversas causas e/ou estruturas responsáveis pela dor lombar, com ou sem irradiação para o membro inferior, pelo que o sucesso no tratamento deste problema depende do diagnóstico diferencial e, consequentemente, da escolha do tratamento mais adequado a cada situação. Objectivo: avaliar os efeitos da terapia manual ortopédica num caso de lombociatalgia, cujo mecanismo dominante é a sensibilização nervosa periférica, no final do tratamento e 8 semanas após a conclusão do mesmo, e descrever a avaliação e intervenção realizadas. Métodos: foi realizado um estudo de caso acerca dum utente do sexo masculino, com 35 anos de idade, e com um quadro clínico compatível com uma situação de sensibilização nervosa periférica. A intervenção consistiu em 5 sessões distribuídas ao longo de 3 semanas. Como instrumentos de avaliação foram utilizados o 'Índice de incapacidade de Oswestry para a lombalgia’ e a Escala Numérica da Dor (END), que foram aplicados na primeira e na última sessões de tratamento e 8 semanas após esta. Resultados: Após o tratamento, verificou-se uma diminuição da incapacidade (de 74 para 2/100) e da intensidade da dor (dor matinal: de 4 para 1/10; dor associada a actividades/posturas em flexão: de 7-8 para 2/10; dor ao fim do dia: de 3-4 para 1-2/10). Oito semanas após a conclusão do tratamento estes valores mantinham-se praticamente inalterados. Conclusão: O processo de raciocínio clínico utilizado na avaliação e intervenção deste caso foi demonstrado. Os resultados obtidos sugerem que a terapia manual ortopédica poderá ser eficaz na diminuição da dor e da incapacidade em casos de lombociatalgia por sensibilização nervosa periférica, e que os ganhos se poderão manter 8 semanas após a conclusão do tratamento. Este estudo pode constituir uma evidência preliminar a favor da terapia manual ortopédica no tratamento deste subgrupo de utentes.
Resumo:
Introdução: neste estudo foi avaliado um caso de lombociatalgia com hérnia discal lombar através de exame clínico confirmado por ressonância magnética. Foi efectuado um tratamento com terapia manual durante 4 semanas até à abolição dos sintomas e recuperação total da função. Objectivos: realizar um tratamento de terapia manual num paciente com lombociatalgia com hérnia discal lombar num período de 1 mês. Métodos: foi realizado um estudo num paciente de 40 anos do sexo masculino que apresentava um quadro de lombociatalgia com hérnia discal lombar. Para a avaliação foram utilizados testes palpatórios com movimento (teste de Mitchell lombar, teste de Gillet sacroilíaco); observação de assimetrias posturais; teste de mobilidade activa em pé; EVA para avaliação da dor; testes de compressão lombar na posição de sentado; testes de condução neurológica; testes neurodinâmicos. Os testes foram aplicados no início e final das 4 primeiras sessões de tratamento com terapia manual, com intervalo de uma semana e um follow-up realizado uma semana após a 4ª sessão. Resultados: após o tratamento de 4 sessões, verificou-se a ausência de postura antálgica. A dor diminuiu de 5/10 para 0/10 (EVA) nos movimentos de flexão, extensão, rotação esquerda e inclinação esquerda do segmento lombar, em pé, com amplitudes normais de mobilidade. A dor diminuiu 3/10 para 0/10 (EVA) no teste de compressão lombar sentado e de 6/10 para 0/10 (EVA) para o teste de compressão lombar sentado com inclinação esquerda. O teste de Mitchell lombar inicial (FRS L5; NSR lombar) ficou negativo assim como o teste de Gillet sacroilíaco; teste de SLR ; SLR + neck flection ; testes de condução de L5 que se encontrava positivo com hipostesia no dermátomo de L5 e grau 3+ de força nos dorsiflexores à esquerda ficou negativo para a hipostesia e grau 5 de força nos dorsiflexores. Conclusão: neste caso o conjunto de técnicas de terapia manual aplicadas juntamente com exercícios terapêuticos, concelhos posturais e de estilos de vida ajudaram o paciente a recuperar totalmente a função e ver abolida a dor.
Resumo:
Mestrado em Fisioterapia
Resumo:
Introdução: O Sustained Natural Apophyseal Glide tem sido sugerido como uma técnica com potenciais benefícios na redução da dor e no aumento da amplitude de flexão lombar em indivíduos com dor lombar. Contudo, não existe evidência sobre esta técnica na atividade muscular dos eretores espinhais. Objetivo: Avaliar os efeitos imediatos de um Sustained Natural Apophyseal Glide na atividade muscular dos eretores espinhais, na intensidade da dor e na amplitude real de flexão lombar, em indivíduos com dor lombar crónica não específica. Métodos: Estudo experimental com uma amostra de 20 estudantes universitários, com dor lombar crónica não específica e com dor à flexão da coluna lombar, que foram aleatoriamente distribuídos em dois grupos: experimental - Sustained Natural Apophyseal Glide e placebo – intervenção placebo. Foram avaliadas a atividade muscular dos eretores espinhais recorrendo à eletromiografia de superfície (bioPLUX research®), a intensidade da dor através da Escala Visual Analógica e a amplitude real de flexão lombar pelo método de duplo inclinómetro (Universal Inclinometer®), antes e após a intervenção, pela análise do movimento de flexão-extensão do tronco. O nível de significância foi de 0,05. Resultados: Foram encontradas diferenças significativas, em ambos os grupos, para a fase de relaxamento (Grupo experimental: p=0,013 e Grupo placebo: p=0,047), assim como para a fase de extensão, no grupo experimental (p=0,037), verificando-se uma diminuição da atividade muscular da baseline para a avaliação final. A Análise da Covariância revelou que, relativamente à intensidade da dor, verificaram-se diferenças significativas entre os dois grupos (p=0,002), sendo que o grupo experimental diminuiu mais 2cm na Escala Visual Analógica do que o grupo placebo. Pela análise da amplitude real de flexão lombar, embora o aumento não fosse significativamente diferente entre os grupos (p=0,086), o grupo experimental teve mais 1,7º de aumento do que o grupo placebo. Conclusão: Os resultados sugerem que, a curto prazo, o Sustained Natural Apophyseal Glide parece produzir um efeito significativo na diminuição da atividade muscular dos eretores espinhais, durante o movimento dinâmico de extensão do tronco, assim como no alívio da dor. Embora não se tenham observado alterações significativas no aumento da amplitude articular, os resultados no grupo experimental foram superiores à diferença mínima detetável, sugerindo um efeito positivo da técnica aplicada.