998 resultados para Liver volume
Resumo:
Background: The « reversed treatment» approach inverts the treatment sequence of¦advanced synchronous colorectal liver metastases - i.e. the liver metastasis is¦treated first, followed by resection of the primary tumor. Chemotherapy is performed¦before and after liver surgery. We recently started to use a reversed treatment¦approach in selected patients. The aim of this study is to critically assess this new¦treatment modality.¦Methods: Nine patients (7 male, 2 female, mean age 62 years) benefited from this¦new treatment between November 2008 and May 2010. The data were collected¦retrospectively.¦Results: All patients responded to the neoadjuvant chemotherapy. The median¦number of liver metastases was 6 (range 1 - 22). The median size of the largest liver¦metastases was 4.3 cm (range 2.6 - 13 cm). Three patients had portal vein¦embolization prior to liver surgery. Two patients could not complete the treatment.¦One had to undergo emergency surgery for occluding colonic tumor. The second one¦showed liver recurrence before starting the adjuvant chemotherapy. The seven¦patients who completed the treatment are still alive after a median time of 27 months¦(range 17 - 37 months). Seven of them had recurrence (1 rectal, 6 liver). The median¦disease-free survival was 9 months (range 0 - 17 months).¦Conclusion: Based on our preliminary experiences, the reversed strategy shows¦encouraging results for the treatment of advanced synchronous colorectal liver¦metastases in well selected patients. The treatment was generally well tolerated and¦long term survival seems to be prolonged.
Resumo:
A produtividade das culturas agrícolas, associada às condições climáticas e edáficas, depende da disponibilidade de água e nutrientes no solo em época e quantidades apropriadas. A falta ou excesso de água no solo são fatores limitantes ao crescimento vegetal e podem diminuir a produtividade. Portanto, estudos que levem a um melhor entendimento de como a água se comporta na zona radicular de uma cultura agrícola no campo são de importância indiscutível ao adequado manejo agrícola. O objetivo do presente trabalho foi avaliar o método do balanço de água no solo aplicado ao volume de solo explorado pelo sistema radicular de uma planta de citros, considerando cinco profundidades de solo e cinco distâncias horizontais do tronco em duas direções a partir do tronco (uma ao longo e outra perpendicular à linha de plantas) e, então, verificar a contribuição de cada uma das camadas de solo avaliadas à evapotranspiração real da planta. O experimento foi realizado num Latossolo Vermelho-Amarelo distrófico argissólico em um pomar de citros, no município de Piracicaba (SP), durante dois períodos, um seco (40 dias) e um chuvoso (37 dias). Para atender ao objetivo proposto, um conjunto de 25 tensiômetros (cinco profundidades x cinco distâncias do tronco) foi instalado ao longo da linha e um outro, idêntico, perpendicular à linha, em direção à entrelinha. A armazenagem foi calculada a partir das leituras dos dois conjuntos de 25 tensiômetros cujos potenciais mátricos determinados foram convertidos em umidades volumétricas pelas curvas de retenção da água no solo. A drenagem interna e a ascensão capilar foram estimadas a partir das leituras diárias dos tensiômetros e da função K(fim) (condutividade hidráulica em função do potencial mátrico), por meio da equação de Darcy-Buckingham. Esta função K(fim) para cada profundidade foi determinada pelo método do perfil instantâneo realizado em área adjacente. A precipitação pluvial foi medida por pluviômetro com aquisição automática de dados instalado na área. Os resultados obtidos mostraram que o método do balanço de água proposto foi adequado para avaliar quanto cada camada de solo da zona radicular da planta contribuiu para o consumo total de água (evapotranspiração real) da planta, nos dois períodos estudados. Nesse sentido, a camada de 0,00 a 0,60 m de profundidade mostrou ser a que a planta deva apresentar maior volume de raízes ativas, de acordo com sua maior contribuição ao consumo de água pela planta.
Resumo:
Liver kidney microsomal type 1 (LKM-1) antibodies have been shown to decrease the CYP2D6 activity in vitro and are present in a minority of patients with chronic hepatitis C infection. We investigated whether LKM-1 antibodies might reduce the CYP2D6 activity in vivo. All patients enrolled in the Swiss Hepatitis C Cohort Study and tested for LKM-1 antibodies were assessed (n = 1723): 10 eligible patients were matched with patients without LKM-1 antibodies. Patients were genotyped for CYP2D6 variants to exclude individuals with a poor metabolizer genotype. CYP2D6 activity was measured by a specific substrate using the dextromethorphan/dextrorphan metabolic ratio to classify patients into four activity phenotypes. All patients had a CYP2D6 extensive metabolizer genotype. The observed phenotype was concordant with the CYP2D6 genotype in most LKM-negative patients, whereas only three LKM-1 positive patients had a concordant phenotype (six presented an intermediate and one a poor metabolizer phenotype). The median DEM/DOR ratio was sixfold higher in LKM-1 positive than in LKM-1 negative patients (0.096 vs. 0.016, P = 0.004), indicating that CYP2D6 metabolic function was significantly reduced in the presence of LKM-1 antibodies. In chronic hepatitis C patients with LKM-1 antibodies, the CYP2D6 metabolic activity was on average reduced by 80%. The impact of LKM-1 antibodies on CYP2D6-mediated drug metabolism pathways warrants further translational studies.
Resumo:
We report the 32nd case of congenital absence of portal vein in an 18-year-old female adult associated with multiple focal nodular hyperplasia of the liver. The association of various hepatic tumors has been observed in half of the publications about congenital absence of portal vein. Hepatic tumors seem to result from systemic diversion of portal vein flow with a resultant increase of arterial flow causing important vascular and nutritif changes the liver and consequent parenchymal transformation.
Resumo:
BACKGROUND: Transient balanced steady-state free-precession (bSSFP) has shown substantial promise for noninvasive assessment of coronary arteries but its utilization at 3.0 T and above has been hampered by susceptibility to field inhomogeneities that degrade image quality. The purpose of this work was to refine, implement, and test a robust, practical single-breathhold bSSFP coronary MRA sequence at 3.0 T and to test the reproducibility of the technique. METHODS: A 3D, volume-targeted, high-resolution bSSFP sequence was implemented. Localized image-based shimming was performed to minimize inhomogeneities of both the static magnetic field and the radio frequency excitation field. Fifteen healthy volunteers and three patients with coronary artery disease underwent examination with the bSSFP sequence (scan time = 20.5 ± 2.0 seconds), and acquisitions were repeated in nine subjects. The images were quantitatively analyzed using a semi-automated software tool, and the repeatability and reproducibility of measurements were determined using regression analysis and intra-class correlation coefficient (ICC), in a blinded manner. RESULTS: The 3D bSSFP sequence provided uniform, high-quality depiction of coronary arteries (n = 20). The average visible vessel length of 100.5 ± 6.3 mm and sharpness of 55 ± 2% compared favorably with earlier reported navigator-gated bSSFP and gradient echo sequences at 3.0 T. Length measurements demonstrated a highly statistically significant degree of inter-observer (r = 0.994, ICC = 0.993), intra-observer (r = 0.894, ICC = 0.896), and inter-scan concordance (r = 0.980, ICC = 0.974). Furthermore, ICC values demonstrated excellent intra-observer, inter-observer, and inter-scan agreement for vessel diameter measurements (ICC = 0.987, 0.976, and 0.961, respectively), and vessel sharpness values (ICC = 0.989, 0.938, and 0.904, respectively). CONCLUSIONS: The 3D bSSFP acquisition, using a state-of-the-art MR scanner equipped with recently available technologies such as multi-transmit, 32-channel cardiac coil, and localized B0 and B1+ shimming, allows accelerated and reproducible multi-segment assessment of the major coronary arteries at 3.0 T in a single breathhold. This rapid sequence may be especially useful for functional imaging of the coronaries where the acquisition time is limited by the stress duration and in cases where low navigator-gating efficiency prohibits acquisition of a free breathing scan in a reasonable time period.
Resumo:
A rugosidade superficial do solo é afetada, dentre outros fatores, pelo tipo de preparo, volume de chuva e estabilidade dos agregados estruturais diante da ação destrutiva da água. Em um Inceptisol, num experimento de erosão sob chuva natural realizado há 15 anos, no Sul da região do Planalto Catarinense, Brasil, avaliou-se a rugosidade superficial, a qual foi expressa por meio dos índices: rugosidade (RR), tortuosidade (T) e diferença de elevação limite (LD), no cultivo do milho, em 2003, e no cultivo da aveia, em 2004, em cujos períodos experimentais precipitaram 229 e 350 mm de chuva, respectivamente. Além disso, em 2004, entre os dois cultivos, avaliou-se a estabilidade dos agregados em água, expressa pelo diâmetro médio ponderado (DMP) e diâmetro médio geométrico (DMG) dos agregados. Os tratamentos de sistemas de manejo do solo foram: preparo convencional (PC) com uma aração + duas gradagens; cultivo mínimo (CM) com uma escarificação + uma gradagem, e semeadura direta (SD), ambos cultivados com milho e aveia, além de um tratamento adicional sem cultivo do solo (SC) em preparo convencional com uma aração + duas gradagens. A rugosidade foi avaliada em cinco oportunidades no cultivo do milho e em quatro da aveia, sendo a primeira avaliação imediatamente após o preparo do solo, e as demais, em intervalos sucessivos de 15 dias. A rugosidade inicial do solo foi alta e diminuiu com o aumento do volume das chuvas nos tratamentos SC, PC e CM, enquanto, na SD, a rugosidade foi alta apenas no cultivo da aveia e apresentou variação muito pequena com o aumento da chuva. O SC apresentou a maior redução da rugosidade ao acaso, enquanto a menor redução ocorreu na SD. A rugosidade superficial foi reduzida da condição original, na qual não se retiraram os efeitos da pendente e das marcas do preparo do solo, para a condição ao acaso, na qual esses efeitos foram retirados. A rugosidade superficial ao acaso relacionou-se inversamente com o volume das chuvas naturais. O decaimento máximo da rugosidade ao acaso relacionou-se inversamente com o DMP e com o DMG dos agregados estruturais.
Resumo:
The effect of a synthetic atrial natriuretic peptide (h-ANP, 25 amino acids, Wy-47.663) on blood pressure, renal electrolyte excretion, plasma catecholamines, and plasma renin activity was studied in nine patients with cirrhosis of the liver and ascites. The peptide was infused intravenously at 24-h intervals for 2 h in groups of four patients each in two different doses (0.015 and 0.075 micrograms/kg/min or 0.06 and 0.3 micrograms/kg/min). A control experiment with the vehicle was performed in all patients. In three patients h-ANP (1 and 2 micrograms/kg i.v.) was administered as an intravenous bolus injection. Consistent falls in blood pressure were observed during h-ANP infusion only with the two higher doses. The two lower infused doses induced a consistent natriuresis; this renal response was abolished when the two larger doses were used. When given as a bolus, h-ANP had a natriuretic effect comparable to that of the two lower doses of infused h-ANP. Plasma catecholamines and plasma renin activity increased during infusion of the two higher doses of h-ANP. It thus appears that in patients with cirrhosis and ascites, the natriuretic effect of infused h-ANP decreases rather than increases when the doses are raised. Bolus administration of h-ANP may be less prone to trigger counterbalancing responses and side-effects.
Resumo:
Introduction: Mean platelet volume (MPV) was shown to be significantly increased in patients with acute ischaemic stroke, especially in non-lacunar strokes. Moreover, some studies concluded that increased MPV is related to poor functional outcome after ischaemic stroke, although this association is still controversial. However, the determinants of MPV in patients with acute ischaemic stroke have never been investigated. Subjects and methods: We recorded the main demographic, clinical and laboratory data of consecutive patients with acute (admitted within 24 h after stroke onset) ischaemic stroke admitted in our Neurology Service between January 2003 and December 2008. MPV was generated at admission by the Sysmex XE-2100 automated cell counter (Sysmex Corporation, Kobe, Japan) from ethylenediaminetetraacetic acid blood samples stored at room temperature until measurement. The association of these parameters with MPV was investigated in univariate and multivariate analysis. Results: A total of 636 patients was included in our study. The median MPV was 10.4 ± 0.82 fL. In univariate analysis, glucose (β= 0.03, P= 0.05), serum creatinine (β= 0.002, P= 0.02), haemoglobin (β= 0.009, P < 0.001), platelet count (β=-0.002, P < 0.001) and history of arterial hypertension (β= 0.21, P= 0.005) were found to be significantly associated with MPV. In multivariate robust regression analysis, only hypertension and platelet count remained as independent determinants of MPV. Conclusions: In patients with acute ischaemic stroke, platelet count and history of hypertension are the only determinants of MPV.