943 resultados para Laboratories diagnostic
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
This paper describes two simple thermal methods for measuring the energy fluence in J/cm 2 from a diagnostic x-ray exposure. Both detectors absorb essentially 100% of the radiation and give a signal that is directly proportional to the energy fluence of the x-ray beam. One detector measures the thermal effect when a pulse of x rays is totally absorbed in the pyroelectric detector of lead-zirconium-titanate (PZT). The other detector measures the expansion of a gas surrounding a lead disk detector in a photoacoustic chamber. The increased pressure of the gas is transmitted through a 1-mm duct to a sensitive microphone. Both detectors have previously been used to measure the energy fluence rate of continuous x-ray beams in the same energy region using a chopped beam and a lock-in amplifier. Measurement of the energy fluence of a pulse of radiation eliminates the need for the beam chopper and lock-in amplifier and results in a simple, rugged, and inexpensive dosimeter. Either method can be combined with the area of the beam to give an estimate of the imparted energy to the patient from a diagnostic x-ray exposure.
Resumo:
Objective: To evaluate the effectiveness of the Gram stain in the initial diagnosis of the etiologic agent of peritonitis in continuous ambulatory peritoneal dialysis (CAPD). Design: Retrospective study analyzing the sensitivity (S), specificity (SS), positive predictive value (+PV), and negative predictive value (-PV) of the Gram stain relating to the results of cultures in 149 episodes of peritonitis in CAPD. The data were analyzed in two studies. In the first, only the cases with detection of a single agent by Gram stain were taken (Study 1). In the second, only the cases with two agents in Gram stain were evaluated (Study 2). Setting: Dialysis Unit and Laboratory of Microbiology of a tertiary medical center. Patients: Sixty-three patients on regular CAPD who presented one or more episodes of peritonitis from May 1992 to May 1995. Results: The positivity of Gram stain was 93.2% and the sensitivity was 95.7%. The values of S, SS, +PV, and -PV were respectively: 94.9%, 53.5%, 68.3%, and 90.9% for gram-positive cocci and 83.3%, 98.8%, 95.2%, and 95.6% for gram-negative bacilli. The association of gram-positive cocci plus gram-negative bacilli were predictive of growth of both in 6.8%, growth of gram-positive cocci in 13.7%, and growth of gram-negative bacilli in 72.5%. Conclusions: The Gram stain is a method of great value in the initial diagnosis of the etiologic agent of peritonitis in CAPD, especially for gram-negative bacilli.
Resumo:
We present here the results of a study of 21 work-related accidents that occurred in a Brazilian manufacturing company. The aim was to assess the safety level of the company to improve its work accident prevention policy. In the last 6 months of 1992 and 1993, all accidents resulting in 15 days' absence from work, reported for social security purposes, were analyzed using the INRS causal tree method (ADC) and a questionnaire completed on site. Potential risk factors for accidents were identified based on the specific factors highlighted by the ADC. More universal trees were also compiled for the safety assessment. Three hundred and thirty specific accident factors were recorded (man of 15.71 per accident). This is consistent with there being multiple causes of accidents rather than the assertion of Brazilian business safety departments that accidents are due to 'dangerous' or 'unsafe' behavior. Introducing the idea of culpability into accidents prevents the implementation of an appropriate information feedback process, essential for effective prevention. However, the large number of accidents related to 'material' (78%) and 'environment' (70%) indicates that working conditions are poor. This shows that the technical risks, mostly due to unsafe machinery and equipment are not being dealt with. Seventy-five potential accident factors were identified. Of these, 35% were 'organizational', a high proportion for the company studied. Improvisation occurs at all levels, particularly at the organizational level. This is, thus a major determinant for entire series of, if not most, accident situations. The poor condition of equipment also plays a major role in accidents. The effects of poor equipment on safety exacerbate the organizational shortcomings. The company's safety intervention policy should improve the management of human resources (rules designating particular workers for particular workstations; instructions for the safe operation of machines and equipment; training of operators, etc.) and introduce programs to detect risks and to improve the safety of machines and equipment. We also recommend the establishment of a program to follow the results of any preventive measures adopted.
Resumo:
We present here the results of a study of 21 work-related accidents that occurred in a Brazilian manufacturing company. The aim was to assess the safety level of the company to improve its work accident prevention policy. In the last 6 months of 1992 and 1993, all accidents resulting in 15 days' absence from work, reported for social security purposes, were analyzed using the INRS causal tree method (ADC) and a questionnaire completed on site. Potential risk factors for accidents were identified based on the specific factors highlighted by the ADC. More universal trees were also compiled for the safety assessment. Three hundred and thirty specific accident factors were recorded (mean of 15.71 per accident). This is consistent with there being multiple causes of accidents rather than the assertion of Brazilian business safety departments that accidents are due to dangerous or unsafe behavior. Introducing the idea of culpability into accidents prevents the implementation of an appropriate information feedback process, essential for effective prevention. However, the large number of accidents related to material (78%) and environment (70%) indicates that working conditions are poor. This shows that the technical risks, mostly due to unsafe machinery and equipment are not being dealt with. Seventy-five potential accident factors were identified. Of these, 35% were organizational, a high proportion for the company studied. Improvisation occurs at all levels, particularly at the organizational level. This is thus a major determinant for entire series of, if not most, accident situations. The poor condition of equipment also plays a major role in accidents. The effects of poor equipment on safety exacerbate the organizational shortcomings. The company's safety intervention policy should improve the management of human resources (rules designating particular workers for particular workstations; instructions for the safe operation of machines and equipment; training of operators, etc.) and introduce programs to detect risks and to improve the safety of machines and equipment. We also recommend the establishment of a program to follow the results of any preventive measures adopted.
Resumo:
The aim of this study was to evaluate the diagnostic agreement of conventional panoramic radiographs and their inverted scanned images in the detection of the mandibular canal and mental foramen. A total of 77 panoramic radiographs obtained from the files of totally edentulous patients were used. Digitization was done by means of a scanner with brightness and contrast adjustment, as well as image inversion. The extension of mandibular canal was divided into anterior, middle, and posterior regions, and the presence of a radiopaque line that characterized the mandibular canal was classified according to a 5-point confidence scale. The mental foramen was classified in 4 types: continuous, separated, diffuse, and unidentified. Both conventional and inverted scanned panoramic radiographs were evaluated by 3 calibrated implantologists at 2 distinct moments with a minimum interval of 10 days between them. Intraexaminer agreement was evaluated by Kappa statistics by point and by 95% confidence interval. Because the intraexaminer level of agreement was low, interexaminer agreements could not be carried out. The results showed a substantial (in 2 situations), moderate (in 16 situations), and fair (in 18 situations) intraexaminer agreement for mandibular canal and a substantial (in 1 situation), fair (in 1 situation), and moderate (in 10 situations) intraeaminer agreement for mental foramen. There were no statistically significant differences in most instances. In conclusion, the diagnostic agreement of conventional and inverted scanned panoramic radiographs for detection of mandibular canal and mental foramen was low.
Resumo:
Delay in diagnosis of pulmonary and other forms of tuberculosis (TB) can be fatal, particularly in HIV-infected patients. Hence, techniques based on nucleic acid amplification, which are both rapid and of high specificity and sensitivity, are now widely used and recommended for laboratories that diagnose TB. In the present study, diagnostic methods based on mycobacterial DNA amplification were evaluated in comparative trials alongside tradicional bacterial methods, using negative smear samples from patients with clinically-suspected TB (sputum samples from 25 patients with suspected pulmonary TB, urine samples from two patients with suspected renal TB and cerebrospinal fluid samples from one patient with suspected meningeal TB). A specificity of 100% was achieved with DNA amplification methods and tradicional culture/identification methods, in relation to clinical findings and treatment results. For the smear-negative sputa, conventional PCR for M. tuberculosis was positive in 62% of suspected lung TB case, showing the same sensitivity as bacterial identification. Both techniques failed in the detection of extra-pulmonary samples. Nested PCR showed, after species-specific amplification, a sensitivity of 100% for M. avium and 85% for M. tuberculosis. For extra-pulmonary smear-negative samples, only Nested PCR detected M. tuberculosis and all cases were confirmed clinically. Nested PCR, in which two-step amplification reactions are performed, can identify the two most important mycobacteria in human pathology quickly and directly from clinical spicimens.
Resumo:
Incluye Bibliografía
Resumo:
Background: The antibody Ki-67 is a reliable and easy tool to accurately assess the growth fraction of neoplasms in humans and animals, and it has been used to predict the clinical outcome. Therefore, the aim of the present study was to investigate the immunohistochemical expression pattern of Ki-67 in normal and neoplastic perianal glands of dogs to evaluate the possible use of this proliferation marker as an ancillary method of perianal tumor diagnosis. We studied 42 cases of perianal gland neoplasms including adenomas (n = 15), epitheliomas (n = 15), and carcinomas (n = 12). As controls, 13 tissue samples from normal perianal glands were used. A Ki-67 index was established by a computer-assisted image analysis and compared with manual counting. Results: Out of the 42 cases of perianal gland neoplasms, 34 were from males and eight from females. Recurrence was reported in 14 cases, being higher (8/12) in carcinomas. Immunostaining for Ki-67 revealed that the carcinomas showed a higher proliferation rate (9.87%) compared to groups of epitheliomas (2.66%) and adenomas (0.36%). For adenomas and epitheliomas of the perianal glands the computer-assisted counting and the manual counting gave similar results; however, only the computer-assisted image analysis was efficient to predict the perianal gland carcinoma recurrence.Conclusion: Since there were significant differences in the number of Ki-67-positive nuclei, this marker proved to be effective in helping the classification of perianal gland neoplasms and to refine the diagnosis criteria, especially in those samples with high variation in morphology/area. Also, higher Ki-67 index is related to recurrence in cases of perianal gland carcinomas. Further, the computer-assisted image analysis proved to be a fast and reliable method to assess the Ki-67 index in perianal gland neoplasms. © 2013 Pereira et al.; licensee BioMed Central Ltd.
Resumo:
Basic research is fundamental for discovering potential diagnostic and therapeutic tools, including drugs, vaccines and new diagnostic techniques. On this basis, diagnosis and treatment methods for many diseases have been developed. Presently, discovering new candidate molecules and testing them in animals are relatively easy tasks that require modest resources and responsibility. However, crossing the animal-to-human barrier is still a great challenge that most researchers tend to avoid. Thus, bridging this current gap between clinical and basic research must be encouraged and elucidated in training programmes for health professionals. This project clearly shows the challenges faced by a group of Brazilian researchers who, after discovering a new fibrin sealant through 20 years of painstaking basic work, insisted on having the product applied clinically. The Brazilian government has recently become aware of this challenge and has accordingly defined the product as strategic to the public health of the country. Thus, in addition to financing research and development laboratories, resources were invested in clinical trials and in the development of a virtual platform termed the Virtual System to Support Clinical Research (SAVPC); this platform imparts speed, reliability and visibility to advances in product development, fostering interactions among sponsors, physicians, students and, ultimately, the research subjects themselves. This pioneering project may become a future model for other public institutions in Brazil, principally in overcoming neglected diseases, which unfortunately continue to afflict this tropical country. © 2013 Elsevier Ltd.
Resumo:
Incluye Bibliografía
Resumo:
Control of cross-contamination between dental offices and prosthetic laboratories is of utmost importance to maintain the health of patients and dental office staff. The purpose of this study was to evaluate disinfection protocols, considering antimicrobial effectiveness and damage to the structures of prostheses. Solutions of 1% sodium hypochlorite, 2% chlorhexidine digluconate, 50% vinegar and sodium perborate were evaluated. Specimens were contaminated in vitro with standardized suspensions of Candida albicans, Streptococcus mutans, Escherichia coli, Staphylococcus aureus and Bacillus subtilis spores. Disinfection by immersion for 10. min was performed. Final counts of microorganisms were obtained using the plating method. Results were statistically compared by Kruskal-Wallis ANOVA and Dunn's test. The surface roughness of 40 specimens was analyzed before and after 10 disinfection cycles, and results were compared statistically using Student's t test. The solution of 50% vinegar was as effective as 1% sodium hypochlorite and 2% chlorhexidine against C. albicans, E. coli and S. mutans. The sodium perborate solution showed the lowest antimicrobial effectiveness. Superficial roughness increased after cycles in 1% sodium hypochlorite (p=0.02). Solutions of 1% sodium hypochlorite, 2% chlorhexidine and 50% vinegar were effective for the disinfection of heat-polymerized acrylic specimens. Sodium hypochlorite increased the superficial roughness. © 2013 King Saud Bin Abdulaziz University for Health Sciences.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)