984 resultados para Homodyne phase detection
Resumo:
A modification of the Dubinin-Radushkevich pore filling model by incorporation of the repulsive contribution to the pore potential, and of bulk non-ideality, is proposed in this paper for characterization of activated carbon using liquid phase adsorption. For this purpose experiments have been performed using ethyl propionate, ethyl butyrate, and ethyl isovalerate as adsorbates and the microporous-mesoporous activated carbons Filtrasorb 400, Norit ROW 0.8 and Norit ROX 0.8 as adsorbents. The repulsive contribution to the pore potential is incorporated through a Lennard-Jones intermolecular potential model, and the bulk-liquid phase non-ideality through the UNIFAC activity coefficient model. For the characterization of activated carbons, the generalized adsorption isotherm is utilized with a bimodal gamma function as the pore size distribution function. It is found that the model can represent the experimental data very well, and significantly better than when the classical energy-size relationship is used, or when bulk non-ideality is neglected. Excellent agreement between the bimodal gamma pore size distribution and DFT-cum-regularization based pore size distribution is also observed, supporting the validity of the proposed model. (C) 2001 Elsevier Science Ltd. All rights reserved.
Resumo:
An increasingly comprehensive assessment is being developed of the extent and potential significance of lateral gene transfer among microbial genomes. Genomic sequences can be identified as being of putatively lateral origin by their unexpected phyletic distribution, atypical sequence composition, differential presence or absence in closely related genomes, or incongruent phylogenetic trees. These complementary approaches sometimes yield inconsistent results. Not only more data but also quantitative models and simulations are needed urgently.
Resumo:
Human polyomaviruses JC and BK may cause several clinical manifestations in immunocompromised hosts, including progressive multifocal leukoencephalopathy and hemorrhagic cystitis. Molecular detection by PCR is recognized as a sensitive and specific method for detecting human polyomaviruses in clinical samples. In this study, a real-time PCR assay using the LightCycler platform was evaluated and compared to an in-house PCR assay using a conventional detection method. A total of 122 urine specimens were tested, and human polyomavirus was detected in 49 specimens (40%) by both conventional PCR and LightCycler PCR. The remaining 73 specimens (60%) were found negative by both assays. For 46 of the 49 positive specimens, LightCycler PCR and conventional PCR identified the same polyomavirus type. These samples included 30 samples with JC virus (JCV), 14 samples with BK virus (BKV), and 2 samples in which both viruses were detected. In the remaining three samples, both JCV and BKV were detected by the conventional assay, but only JCV was detected by the LightCycler assay. The results of this study show that the LightCycler PCR assay displays sensitivity and specificity similar to those of a conventional PCR assay. These data, combined with its rapid turnaround time for results and decreased hands-on time, make the LightCycler PCR assay highly suitable for the rapid detection and differentiation of JCV and BKV in the clinical laboratory.
Resumo:
The Alcohol Use Disorders Identification Test (AUDIT) has been used widely and is reported to be superior to conventional questionnaires in detection of current hazardous and harmful alcohol use. We assessed the validity of an Australian modification of the AUDIT (the AusAUDIT), which has been employed widely in Australian and New Zealand early intervention programmes. We used a cross-sectional study of 370 subjects from the follow-up phase of a randomized controlled trial of early intervention to reduce hazardous alcohol consumption. Scores on the AusAUDIT were compared against 12-month ICD-10 diagnoses of harmful alcohol use and dependence, as determined by the Composite International Diagnostic Interview, and against self-report of alcohol consumption exceeding Australian National Health and Medical Research Council (NH&MRC) recommended limits. AusAUDIT had good internal consistency and discriminated significantly between persons meeting criteria for ICD-10 alcohol use disorders, and drinkers who did not. At currently recommended cut-off scores, AusAUDIT detected more than 85% of people meeting criteria for ICD-10 alcohol use disorders, or drinking over NH&MRC recommended limits, but its specificity was limited (29% in men, and 58% in women for drinking over NH&MRC limits). No subset of questions performed as well as the full AusAUDIT in detection of drinking problems, but the alcohol consumption items provided a reasonable screen for drinking over NH&MRC limits. We conclude that AusAUDIT is effective in detecting problematic drinking, but positive cases should be confirmed by clinical assessment. The findings illustrate the need for validation of questionnaire modifications, and the difficulty in increasing test sensitivity without reducing specificity.
Resumo:
We derive optimal N-photon two-mode input states for interferometric phase measurements. Under canonical measurements the phase variance scales as N-2 for these states, as compared to N-1 or N-1/2 for states considered bq previous authors. We prove, that it is not possible to realize the canonical measurement by counting photons in the outputs of the interferometer, even if an adjustable auxiliary phase shift is allowed in the interferometer. However. we introduce a feedback algorithm based on Bayesian inference to control this auxiliary phase shift. This makes the measurement close to a canonical one, with a phase variance scaling slightly above N-2. With no feedback, the best result (given that the phase to be measured is completely unknown) is a scaling of N-1. For optimal input states having up to four photons, our feedback scheme is the best possible one, but for higher photon numbers more complicated schemes perform marginally better.
Resumo:
It is not possible to make measurements of the phase of an optical mode using linear optics without introducing an extra phase uncertainty. This extra phase variance is quite large for heterodyne measurements, however it is possible to reduce it to the theoretical limit of log (n) over bar (4 (n) over bar (2)) using adaptive measurements. These measurements are quite sensitive to experimental inaccuracies, especially time delays and inefficient detectors. Here it is shown that the minimum introduced phase variance when there is a time delay of tau is tau/(8 (n) over bar). This result is verified numerically, showing that the phase variance introduced approaches this limit for most of the adaptive schemes using the best final phase estimate. The main exception is the adaptive mark II scheme with simplified feedback, which is extremely sensitive to time delays. The extra phase variance due to time delays is considered for the mark I case with simplified feedback, verifying the tau /2 result obtained by Wiseman and Killip both by a more rigorous analytic technique and numerically.
Resumo:
The continuous parametric pumping of a superconducting lossy QED cavity supporting a field prepared initially as a superposition of coherent states is discussed. In contrast to classical pumping, we verify that the phase sensitivity of the parametric pumping makes the asymptotic behaviour of the cavity field state strongly dependent on the phase theta of the coherent state \ alpha > = \ alpha \e(i theta)>. Here we consider theta = pi /4, -pi /4 and we analyse the evolution of the purity of the superposition states with the help of the linear entropy and fidelity functions. We also analyse the decoherence process quantitatively through the Wigner function, for both states, verifying that the decay is slightly modified when compared to the free decoherence case: for theta = -pi /4 the process is accelerated while for theta = pi /4 it is delayed.
Resumo:
Unit-efficiency homodyne detection of the resonance fluorescence of a two-level atom collapses the quantum state of the atom to a stochastically moving point on the Bloch sphere. Recently, Hofmann, Mahler, and Hess [Phys. Rev. A 57, 4877 (1998)] showed that by making part of the coherent driving proportional to the homodyne photocurrent one can stabilize the state to any point on the bottom-half of the sphere. Here we reanalyze their proposal using the technique of stochastic master equations, allowing their results to be generalized in two ways. First, we show that any point on the upper- or lower-half, but not the equator, of the sphere may be stabilized. Second, we consider nonunit-efficiency detection, and quantify the effectiveness of the feedback by calculating the maximal purity obtainable in any particular direction in Bloch space.
Resumo:
The principle that alloys are designed to accommodate the manufacture of goods made from them as much as the properties required of them in service has not been widely applied to pressed and sintered P/M aluminium alloys. Most commercial alloys made from mixed elemental blends are identical to standard wrought alloys. Alternatively, alloys can be designed systematically using the phase diagram characteristics of ideal liquid phase sintering systems. This requires consideration of the solubilities of the alloying elements in aluminium, the melting points of the elements, the eutectics they form with aluminium and the nature of the liquid phase. The relative diffusivities are also important. Here we show that Al-Sn, which closely follows these ideal characteristics, has a much stronger sintering response than either Al-Cu or Al-Zn, both of which have at least one non-ideal characteristic. (C) 2001 Elsevier Science B.V. All rights reserved.
Resumo:
Aluminium alloys that contain Si, Mg, Fe, Mn and/or Cu usually contain one or more types of intermetallic phases that are not readily distinguishable in the microstructure by conventional microscopy methods. It has thus been a challenge to develop a method that will unambiguously identify them. A practical approach has been developed that is based on an inherent linear relationship revealed for the overall distribution of any two elements in a precipitate/matrix geometry and the first-order approximation of electron probe microanalysis (EPMA) results. Application of this approach to a direct chill cast 6082 alloy is demonstrated, and its major limitations are discussed.
Resumo:
Active surveillance for dengue (DEN) virus infected mosquitoes can be an effective way to predict the risk of dengue infection in a given area. However, doing so may pose logistical problems if mosquitoes must be kept alive or frozen fresh to detect DEN virus. In an attempt to simplify mosquito processing, we evaluated the usefulness of a sticky lure and a seminested reverse-transcriptase polymerase chain reaction assay (RT-PCR) for detecting DEN virus RNA under laboratory conditions using experimentally infected Aedes aegypti (L.) mosquitoes. In the first experiment, 40 male mosquitoes were inoculated with 0.13 mul of a 10(4) pfu/ml DEN-2 stock solution. After a 7-d incubation period, the mosquitoes were applied to the sticky lure and kept at room temperatures of 23-30 degreesC. Following 7,10,14, and 28 d application, 10 mosquitoes each were removed from the lure pooled and assayed for virus. DEN virus nucleic acid was clearly detectable in all pools up to 28 d after death. A second study evaluated sensitivity and specificity using one, two, and five DEN-infected mosquitoes removed after 7, 10, 14, 21 and 30 d application and tested by RT-PCR. All four DEN serotypes were individually inoculated in mosquitoes and evaluated using the same procedures as experiment 1. The four serotypes were detectable in as few as one mosquito 30 d after application to the lure with no evidence of cross-reactivity. The combination of sticky lures and RT-PCR show promise for mosquito and dengue virus surveillance and warrant further evaluation.
Scavenging of siliceous grain-boundary phase of 8-mol%-ytterbia-stabilized zirconia without additive
Resumo:
The grain-boundary conductivity (sigma (gb),) of 8-mol%-ytterbiastabilized zirconia increased markedly with heat treatment between 1000 degrees and 1300 degreesC with a slow heating rate (0.1 degreesC/min) before sintering. The extent of the sigma (gb) improvement was the same or larger than that via Al2O3 addition. The heat treatment did not affect the grain-interior conduction when sintered at 1600 degreesC, while Al2O3-derived scavenging significantly did, given the larger increment of total conductivity in the heat-treated sample. The formation of a silicon-containing phase in a discrete form was suggested as a possible route of scavenging the resistive phase from the correlation between average grain size and sigma (gb).
Resumo:
Purpose: To assess the toxicity and the efficacy of preoperative radiotherapy with continuous infusion 5-fluorouracil (5-FU) for locally advanced adenocarcinoma of the rectum. Methods and Materials: Eligible patients had newly diagnosed localized adenocarcinoma of the rectum within 12 cm of the anal verge, Stage T3-4, and were suitable for curative resection. Eighty-two patients were treated with radiotherapy-50.4 Gy in 28 fractions in 5.6 weeks, given concurrently with continuous infusion 5-FU, using either 96-h/week infusion at 300 mg/m(2)/day or 7-days/week infusion at 225 mg/m(2)/day. Results: The median age was 59 years (range, 27-87), and 67% of patients were male. Pretreatment stages of the rectal cancer were T3, 89% and resectable T4, 11%, with endorectal ultrasound confirmation in 67% of patients. Grade 3 acute toxicity occurred in 5 of 82 patients (6%; 95% confidence interval [CI], 2-14%). Types of surgical resection were anterior resection, 61%; abdominoperineal resection, 35%; and other procedures, 4%. There was no operative mortality. Anastomotic leakage after low anterior resection occurred in 3 of 50 patients (6%; 95% CI, 1-17%). The pathologic complete response rate was 16% (95% CI, 9-26%). Pathologic Stages T2 or less occurred in 51%. Conclusion: Preoperative radiotherapy with continuous infusion 5-FU for locally advanced rectal cancer is a safe regimen, with a significant downstaging effect. It does not seem to lead to a significant increase in serious surgical complications. (C) 2001 Elsevier Science Inc.