975 resultados para Global Solar-radiation
Resumo:
It is known that a green wall brings some advantages to a building. It constitutes a barrier against solar radiation, thus decreasing and delaying the incoming heat flux. The aim of this study is to quantify such advantages through analytical comparison between two facades, a vegetal facade and a conventional facade. Both were highly insulated (U-value = 0.3 W/m2K) and installed facing south on the same building in the central territory of Spain. In order to compare their thermal trend, a series of sensors were used to register superficial and indoor air temperature. The work was carried out between 17th August 2012 and 1st October 2012, with a temperature range of 12°C-36°C and a maximum horizontal radiation of 1020 W/m2. Results show that the indoor temperature of the green wall module was lower than the other. Besides, comparing superficial outdoor and indoor temperatures of the two walls to outdoor air temperatures, it was noticed that, due to the shading plants, the green wall superficial temperature was 5 °C lower on the facade, while the bare wall temperature was 15 °C higher. The living wall module temperature was 1.6 °C lower than the outdoor, while the values of the conventional one were similar to the outdoor air temperature.
Resumo:
This paper assesses rural vernacular heritage established in a warm temperate climate, with dry, hot summer, in São Vicente e Ventosa (SVV), Alentejo, Portugal, and takes part in a larger investigation intending to create rehabilitation guidelines, with sustainable criteria and integration of recent technologies, to improving indoor comfort, and revert the state of deterioration. To further reach this aim, this paper proposes a four phases methodology: data collection, evaluation, simulation and development; a first survey data analysis, including climate data and the adapted comfort climograph and isopleth diagram, allows an understanding of thermal comfort and main constraints in site, as well as suitable bioclimatic strategies for SVV: high thermal inertia for tempering extreme summer conditions and the considerable temperature amplitudes throughout the year, complementarily night ventilation for passive cooling, small-sized window openings and movable shading systems for solar radiation protection. An efficient behaviour in stabilizing indoor temperature swings is revealed.
Resumo:
The bankability of CPV projects is an important issue to pave the way toward a swift and sustained growth in this technology. The bankability of a PV plant is generally addressed through the modeling of its energy yield under a b aseline loss scenario, followed by an on-site measurement campaign aimed at verifying its energetic behavior. The main difference between PV and CPV resides in the proper CPV modules, in particular in the inclusion of optical lements and III-V multijunction cells that are much more sensitive to spectral variations than xSi cells, while the rest of the system behaves in a way that possesses many common points with xSi technology. The modeling of the DC power output of a CPV system thus requires several impo rtant second order parameters to be considered, mainly related to optics, spectral direct solar radiation, wind speed, tracker accuracy and heat dissipation of cells.
Resumo:
El objetivo del presente proyecto es realizar el pre-diseño de una instalación solar mixta fotovoltaica-térmica para satisfacer la demanda eléctrica para iluminación y para parte de las necesidades de energía térmica para agua caliente de una vivienda. El proyecto define las condiciones técnicas de la instalación a partir de la radiación solar registrada en la localización elegida. Además de incluir el estudio económico y los planos correspondientes que indican la viabilidad del mismo. Como puntos a destacar en el proyecto, se puede tomar los datos obtenidos de generación eléctrica y térmica, la viabilidad técnica y económica y el análisis de la incipiente tecnología de paneles híbridos fotovoltaicos-térmicos. La incorporación de las energías renovables es ya una realidad para las viviendas de nueva construcción, en cambio son pocas las nuevas instalaciones en edificios o viviendas ya construidas. Es importante promover este tipo de tecnologías con objetivo de reducir la dependencia actual de los combustibles fósiles y evitar así sus efectos nocivos al medio ambiente. ABSTRACT The purpose of this project is to carry out the draft design of a solar mixed photovoltaic-thermal installation to satisfy the electrical and thermal demand in a building, for lighting as well as for some of the energy required for water heating. The project defines the technical conditions of the system, given the solar radiation registered in the chosen location. It also includes the economic analysis and the respective plans that indicates the viability of the project. The highlights of the project are the following: electricity and thermal energy generation data, the technical and financial viability and the analysis of the new technology of the Photovoltaic-Thermal hybrid solar collectors. The inclusion of renewable energies is already a living reality for newly constructed buildings. By contrast, they are rarely implemented in old buildings. In order to be able to reduce the fossil fuels dependency, and in doing so, avoid its damaging effects on the environment, it is very important to promote the use of these cleaner technologies.
Resumo:
Reducing the gap between water-limited potential yield and actual yield in oil palm production systems through intensification is seen as an important option for sustainably increasing palm oil production. Simulation models can play an important role in quantifying water-limited potential yield, and therefore the scope for intensification, but no oil palm model exists that is both simple enough and at the same time incorporates sufficient plant physiological knowledge to be generally applicable across sites with different growing conditions. The objectives of this study therefore were to develop a model (PALMSIM) that simulates, on a monthly time step, the potential growth of oil palm as determined by solar radiation and to evaluate model performance against measured oil palm yields under optimal water and nutrient management for a range of sites across Indonesia and Malaysia. The maximum observed yield in the field matches the corresponding simulated yield for dry bunch weight with a RMSE of 1.7 Mg ha?1 year?1 against an observed yield of 18.8 Mg ha?1. Sensitivity analysis showed that PALMSIM is robust: simulated changes in yield caused by modifying the parameters by 10% are comparable to other tree crop model evaluations. While we acknowledge that, depending on the soils and climatic environment, yields may be often water limited, we suggest a relatively simple physiological approach to simulate potential yield, which can be usefully applied to high rainfall environments and is considered as a first step in developing an oil palm model that also simulates water-limited potential yield. To illustrate the application possibil- ities of the model, PALMSIM was used to create a potential yield map for Indonesia and Malaysia by sim- ulating the growth and yield at a resolution of 0.1?. This map of potential yield is considered as a first step towards a decision support tool that can identify potentially productive, but at the moment degraded sites in Indonesia and Malaysia. ?
Resumo:
In the work, the results of an investigation of GaInP/GaInAs/Ge MJ SCs intended for converting concentrated solar radiation, when operating at low temperatures (down to -190 degrees C) are presented. A kink of the cell I-V characteristic has been observed in the region close to V-oc starting from -20 degrees C at operation under concentrated sunlight. The causes for its occurrence have been analyzed and the reasons for formation of a built-in potential barrier for majority charge carriers at the n-GaInP/n-Ge isotype hetero-interface are discussed. The effect of charge carrier transport in n-GaInP/n-p Ge heterostructures on MJ SC output characteristics at low temperatures has been studied including EL technique.
Resumo:
This paper demonstrates the importance of a holistic comprehension of the Earth like a planet that is alive, not only in its Biosphere, looking at the atmosphere-ocean-crust-mantle interactions as its different sectorial expressions (climate, fluid-dynamics, morpho-dynamics, tectonics…) following the solar radiation and nuclear geothermal sources of energy. It considers the environmental incidence of different engineering activities to realize their underfeeding as the raison, and leads to that holistic formation as the being of the engineering geology
Resumo:
In the present paper, 1-year PM10 and PM 2.5 data from roadside and urban background monitoring stations in Athens (Greece), Madrid (Spain) and London (UK) are analysed in relation to other air pollutants (NO,NO2,NOx,CO,O3 and SO2)and several meteorological parameters (wind velocity, temperature, relative humidity, precipitation, solar radiation and atmospheric pressure), in order to investigate the sources and factors affecting particulate pollution in large European cities. Principal component and regression analyses are therefore used to quantify the contribution of both combustion and non-combustion sources to the PM10 and PM 2.5 levels observed. The analysis reveals that the EU legislated PM 10 and PM2.5 limit values are frequently breached, forming a potential public health hazard in the areas studied. The seasonal variability patterns of particulates varies among cities and sites, with Athens and Madrid presenting higher PM10 concentrations during the warm period and suggesting the larger relative contribution of secondary and natural particles during hot and dry days. It is estimated that the contribution of non-combustion sources varies substantially among cities, sites and seasons and ranges between 38-67% and 40-62% in London, 26-50% and 20-62% in Athens, and 31-58% and 33-68% in Madrid, for both PM10 and PM 2.5. Higher contributions from non-combustion sources are found at urban background sites in all three cities, whereas in the traffic sites the seasonal differences are smaller. In addition, the non-combustion fraction of both particle metrics is higher during the warm season at all sites. On the whole, the analysis provides evidence of the substantial impact of non-combustion sources on local air quality in all three cities. While vehicular exhaust emissions carry a large part of the risk posed on human health by particle exposure, it is most likely that mitigation measures designed for their reduction will have a major effect only at traffic sites and additional measures will be necessary for the control of background levels. However, efforts in mitigation strategies should always focus on optimal health effects.
Resumo:
El principal objetivo de la tesis es estudiar el acoplamiento entre los subsistemas de control de actitud y de control térmico de un pequeño satélite, con el fin de buscar la solución a los problemas relacionados con la determinación de los parámetros de diseño. Se considera la evolución de la actitud y de las temperaturas del satélite bajo la influencia de dos estrategias de orientación diferentes: 1) estabilización magnética pasiva de la orientación (PMAS, passive magnetic attitude stabilization), y 2) control de actitud magnético activo (AMAC, active magnetic attitude control). En primer lugar se presenta el modelo matemático del problema, que incluye la dinámica rotacional y el modelo térmico. En el problema térmico se considera un satélite cúbico modelizado por medio de siete nodos (seis externos y uno interno) aplicando la ecuación del balance térmico. Una vez establecido el modelo matemático del problema, se estudia la evolución que corresponde a las dos estrategias mencionadas. La estrategia PMAS se ha seleccionado por su simplicidad, fiabilidad, bajo coste, ahorrando consumo de potencia, masa coste y complejidad, comparado con otras estrategias. Se ha considerado otra estrategia de control que consigue que el satélite gire a una velocidad requerida alrededor de un eje deseado de giro, pudiendo controlar su dirección en un sistema inercial de referencia, ya que frecuentemente el subsistema térmico establece requisitos de giro alrededor de un eje del satélite orientado en una dirección perpendicular a la radiación solar incidente. En relación con el problema térmico, para estudiar la influencia de la velocidad de giro en la evolución de las temperaturas en diversos puntos del satélite, se ha empleado un modelo térmico linealizado, obtenido a partir de la formulación no lineal aplicando un método de perturbaciones. El resultado del estudio muestra que el tiempo de estabilización de la temperatura y la influencia de las cargas periódicas externas disminuye cuando aumenta la velocidad de giro. Los cambios de temperatura se reducen hasta ser muy pequeños para velocidades de rotación altas. En relación con la estrategia PMAC se ha observado que a pesar de su uso extendido entre los micro y nano satélites todavía presenta problemas que resolver. Estos problemas están relacionados con el dimensionamiento de los parámetros del sistema y la predicción del funcionamiento en órbita. Los problemas aparecen debido a la dificultad en la determinación de las características magnéticas de los cuerpos ferromagnéticos (varillas de histéresis) que se utilizan como amortiguadores de oscilaciones en los satélites. Para estudiar este problema se presenta un modelo analítico que permite estimar la eficiencia del amortiguamiento, y que se ha aplicado al estudio del comportamiento en vuelo de varios satélites, y que se ha empleado para comparar los resultados del modelo con los obtenidos en vuelo, observándose que el modelo permite explicar satisfactoriamente el comportamiento registrado. ABSTRACT The main objective of this thesis is to study the coupling between the attitude control and thermal control subsystems of a small satellite, and address the solution to some existing issues concerning the determination of their parameters. Through the thesis the attitude and temperature evolution of the satellite is studied under the influence of two independent attitude stabilization and control strategies: (1) passive magnetic attitude stabilization (PMAS), and (2) active magnetic attitude control (AMAC). In this regard the mathematical model of the problem is explained and presented. The mathematical model includes both the rotational dynamics and the thermal model. The thermal model is derived for a cubic satellite by solving the heat balance equation for 6 external and 1 internal nodes. Once established the mathematical model of the problem, the above mentioned attitude strategies were applied to the system and the temperature evolution of the 7 nodes of the satellite was studied. The PMAS technique has been selected to be studied due to its prevalent use, simplicity, reliability, and cost, as this strategy significantly saves the overall power, weight, cost, and reduces the complexity of the system compared to other attitude control strategies. In addition to that, another control law that provides the satellite with a desired spin rate along a desired axis of the satellite, whose direction can be controlled with respect to the inertial reference frame is considered, as the thermal subsystem of a satellite usually demands a spin requirement around an axis of the satellite which is positioned perpendicular to the direction of the coming solar radiation. Concerning the thermal problem, to study the influence of spin rate on temperature evolution of the satellite a linear approach of the thermal model is used, which is based on perturbation theory applied to the nonlinear differential equations of the thermal model of a spacecraft moving in a closed orbit. The results of this study showed that the temperature stabilization time and the periodic influence of the external thermal loads decreases by increasing the spin rate. However, the changes become insignificant for higher values of spin rate. Concerning the PMAS strategy, it was observed that in spite of its extended application to micro and nano satellites, still there are some issues to be solved regarding this strategy. These issues are related to the sizing of its system parameters and predicting the in-orbit performance. The problems were found to be rooted in the difficulties that exist in determining the magnetic characteristics of the ferromagnetic bodies (hysteresis rods) that are applied as damping devices on-board satellites. To address these issues an analytic model for estimating their damping efficiency is proposed and applied to several existing satellites in order to compare the results with their respective in-flight data. This model can explain the behavior showed by these satellites.
Resumo:
In this work the thermal analysis of a small satellite orbiting around the Earth has been approached by direct integration of the heat balance equations of a two-node reduced model, obtaining a linearized second order ODE problem, similar in form to the classical case of the forced vibration of a damped system. As the thermal loads (solar radiation, albedo, etc.) are harmonic, the problem is solved by means of Fourier analysis methods. Research on that field can be directly applied to the analysis of thermal problems and the results obtained are satisfactory. Working on the frequency domain streamlines the analysis, simplifies the study and facilitates the experimental testing. The transfer functions are obtained for the two-node case but the study can be extended to an n-node model.
Resumo:
La presente Tesis Doctoral evalúa la contribución de una fachada activa, constituida por acristalamientos con circulación de agua, en el rendimiento energético del edificio. Con especial énfasis en la baja afección sobre su imagen, su integración ha de favorecer la calificación del edificio con el futuro estándar de Edificio de consumo de Energía Casi Nulo (EECN). El propósito consiste en cuantificar su aportación a limitar la demanda de climatización, como solución de fachada transparente acorde a las normas de la energía del 2020. En el primer capítulo se introduce el planteamiento del problema. En el segundo capítulo se desarrollan la hipótesis y el objetivo fundamental de la investigación. Para tal fin, en el tercer capítulo, se revisa el estado del arte de la tecnología y de la investigación científica, mediante el análisis de la literatura de referencia. Se comparan patentes, prototipos, sistemas comerciales asimilables, investigaciones en curso en Universidades, y proyectos de investigación y desarrollo, sobre envolventes que incorporan acristalamientos con circulación de agua. El método experimental, expuesto en el cuarto capítulo, acomete el diseño, la fabricación y la monitorización de un prototipo expuesto, durante ciclos de ensayos, a las condiciones climáticas de Madrid. Esta fase ha permitido adquirir información precisa sobre el rendimiento del acristalamiento en cada orientación de incidencia solar, en las distintas estaciones del año. En paralelo, se aborda el desarrollo de modelos teóricos que, mediante su asimilación a soluciones multicapa caracterizadas en las herramientas de simulación EnergyPlus y IDA-ICE (IDA Indoor Climate and Energy), reproducen el efecto experimental. En el quinto capítulo se discuten los resultados experimentales y teóricos, y se analiza la respuesta del acristalamiento asociado a un determinado volumen y temperatura del agua. Se calcula la eficiencia en la captación de la radiación y, mediante la comparativa con un acristalamiento convencional, se determina la reducción de las ganancias solares y las pérdidas de energía. Se comparan el rendimiento del acristalamiento, obtenido experimentalmente, con el ofrecido por paneles solares fototérmicos disponibles en el mercado. Mediante la traslación de los resultados experimentales a casos de células de tamaño habitable, se cuantifica la afección del acristalamiento sobre el consumo en refrigeración y calefacción. Diferenciando cada caso por su composición constructiva y orientación, se extraen conclusiones sobre la reducción del gasto en climatización, en condiciones de bienestar. Posteriormente, se evalúa el ahorro de su incorporación en un recinto existente, de construcción ligera, localizado en la Escuela de Arquitectura de la Universidad Politécnica de Madrid (UPM). Mediante el planteamiento de escenarios de rehabilitación energética, se estima su compatibilidad con un sistema de climatización mediante bomba de calor y extracción geotérmica. Se describe el funcionamiento del sistema, desde la perspectiva de la operación conjunta de los acristalamientos activos e intercambio geotérmico, en nuestro clima. Mediante la parametrización de sus funciones, se estima el beneficio adicional de su integración, a partir de la mejora del rendimiento de la bomba de calor COP (Coefficient of Performance) en calefacción, y de la eficiencia EER (Energy Efficiency Ratio) en refrigeración. En el recinto de la ETSAM, se ha analizado la contribución de la fachada activa en su calificación como Edificio de Energía Casi Nula, y estudiado la rentabilidad económica del sistema. En el sexto capítulo se exponen las conclusiones de la investigación. A la fecha, el sistema supone alta inversión inicial, no obstante, genera elevada eficiencia con bajo impacto arquitectónico, reduciéndose los costes operativos, y el dimensionado de los sistemas de producción, de mayor afección sobre el edificio. Mediante la envolvente activa con suministro geotérmico no se condena la superficie de cubierta, no se ocupa volumen útil por la presencia de equipos emisores, y no se reduce la superficie o altura útil a base de reforzar los aislamientos. Tras su discusión, se considera una alternativa de valor en procesos de diseño y construcción de Edificios de Energía Casi Nulo. Se proponen líneas de futuras investigación cuyo propósito sea el conocimiento de la tecnología de los acristalamientos activos. En el último capítulo se presentan las actividades de difusión de la investigación. Adicionalmente se ha proporcionado una mejora tecnológica a las fachadas activas existentes, que ha derivado en la solicitud de una patente, actualmente en tramitación. ABSTRACT This Thesis evaluates the contribution of an active water flow glazing façade on the energy performance of buildings. Special emphasis is made on the low visual impact on its image, and the active glazing implementation has to encourage the qualification of the building with the future standard of Nearly Zero Energy Building (nZEB). The purpose is to quantify the façade system contribution to limit air conditioning demand, resulting in a transparent façade solution according to the 2020 energy legislation. An initial approach to the problem is presented in first chapter. The second chapter develops the hypothesis and the main objective of the research. To achieve this purpose, the third chapter reviews the state of the art of the technology and scientific research, through the analysis of reference literature. Patents, prototypes, assimilable commercial systems, ongoing research in other universities, and finally research and development projects incorporating active fluid flow glazing are compared. The experimental method, presented in fourth chapter, undertakes the design, manufacture and monitoring of a water flow glazing prototype exposed during test cycles to weather conditions in Madrid. This phase allowed the acquisition of accurate information on the performance of water flow glazing on each orientation of solar incidence, during different seasons. In parallel, the development of theoretical models is addressed which, through the assimilation to multilayer solutions characterized in the simulation tools EnergyPlus and IDA-Indoor Climate and Energy, reproduce the experimental effect. Fifth chapter discusses experimental and theoretical results focused to the analysis of the active glazing behavior, associated with a specific volume and water flow temperature. The efficiency on harvesting incident solar radiation is calculated, and, by comparison with a conventional glazing, the reduction of solar gains and energy losses are determined. The experimental performance of fluid flow glazing against the one offered by photothermal solar panels available on the market are compared. By translating the experimental and theoretical results to cases of full-size cells, the reduction in cooling and heating consumption achieved by active fluid glazing is quantified. The reduction of energy costs to achieve comfort conditions is calculated, differentiating each case by its whole construction composition and orientation. Subsequently, the saving of the implementation of the system on an existing lightweight construction enclosure, located in the School of Architecture at the Polytechnic University of Madrid (UPM), is then calculated. The compatibility between the active fluid flow glazing and a heat pump with geothermal heat supply system is estimated through the approach of different energy renovation scenarios. The overall system operation is described, from the perspective of active glazing and geothermal heat exchange combined operation, in our climate. By parameterization of its functions, the added benefit of its integration it is discussed, particularly from the improvement of the heat pump performance COP (Coefficient of Performance) in heating and efficiency EER (Energy Efficiency Ratio) in cooling. In the case study of the enclosure in the School of Architecture, the contribution of the active glazing façade in qualifying the enclosure as nearly Zero Energy Building has been analyzed, and the feasibility and profitability of the system are studied. The sixth chapter sets the conclusions of the investigation. To date, the system may require high initial investment; however, high efficiency with low architectural impact is generated. Operational costs are highly reduced as well as the size and complexity of the energy production systems, which normally have huge visual impact on buildings. By the active façade with geothermal supply, the deck area it is not condemned. Useful volume is not consumed by the presence of air-conditioning equipment. Useful surface and room height are not reduced by insulation reinforcement. After discussion, water flow glazing is considered a potential value alternative in nZEB design and construction processes. Finally, this chapter proposes future research lines aiming to increase the knowledge of active water flow glazing technology. The last chapter presents research dissemination activities. Additionally, a technological improvement to existing active facades has been developed, which has resulted in a patent application, currently in handling process.
Resumo:
The effect of atmospheric aerosols and regional haze from air pollution on the yields of rice and winter wheat grown in China is assessed. The assessment is based on estimates of aerosol optical depths over China, the effect of these optical depths on the solar irradiance reaching the earth’s surface, and the response of rice and winter wheat grown in Nanjing to the change in solar irradiance. Two sets of aerosol optical depths are presented: one based on a coupled, regional climate/air quality model simulation and the other inferred from solar radiation measurements made over a 12-year period at meteorological stations in China. The model-estimated optical depths are significantly smaller than those derived from observations, perhaps because of errors in one or both sets of optical depths or because the data from the meteorological stations has been affected by local pollution. Radiative transfer calculations using the smaller, model-estimated aerosol optical depths indicate that the so-called “direct effect” of regional haze results in an ≈5–30% reduction in the solar irradiance reaching some of China’s most productive agricultural regions. Crop-response model simulations suggest an ≈1:1 relationship between a percentage increase (decrease) in total surface solar irradiance and a percentage increase (decrease) in the yields of rice and wheat. Collectively, these calculations suggest that regional haze in China is currently depressing optimal yields of ≈70% of the crops grown in China by at least 5–30%. Reducing the severity of regional haze in China through air pollution control could potentially result in a significant increase in crop yields and help the nation meet its growing food demands in the coming decades.
Resumo:
Surveys of butterfly and moth diversity in tropical forest fragments suggest that nocturnality confers a dispersal, and possibly a survival, advantage. The butterfly faunas of smaller fragments were depauperate; in contrast, the species richness of nocturnal moths was similar in all fragments and even in pasture. The lack of correlation between butterfly and moth species richness among fragments (r2 = 0.005) is best explained by movements of moths at night when ambient conditions in forest and pasture are most similar; butterflies face substantial daytime temperature, humidity, and solar radiation barriers. This interpretation is supported by information on birds, beetles, and bats.
Resumo:
Os organismos marinhos constituem uma fonte potencial de metabólitos secundários biologicamente ativos. Neste contexto, os micro-organismos isolados de algas marinhas, dentre eles fungos endofíticos, representam alvos para a pesquisa de novas substâncias com potencial farmacológico pronunciado. Substâncias naturais provenientes de espécies de fungos associados às algas marinhas vêm sendo bastante utilizadas em formulações fotoprotetoras devido à ação antioxidante e ao potencial contra a radiação solar. Deste modo, o presente trabalho teve como objetivo a investigação biológica e química dos fungos endofíticos marinhos pertencentes à família Xylariaceae, o Annulohypoxylon stygium, o Cladosporium sp. e o Acremonium implicatum (Hypocreaceae). A princípio, foi realizado um screening para avaliar a absorção de luz ultravioleta na faixa do UVA e UVB pelos extratos obtidos em escala piloto destes fungos endofíticos associados às algas marinhas. O extrato do fungo A. stygium apresentou intensa absorção na região do UV, mostrando-se promissor para a produção de metabólitos secundários com ação fotoprotetora. Além do ensaio proposto, foi realizada a avaliação do potencial antibacteriano e antifúngico da espécie A. stygium. O estudo químico em escala ampliada deste fungo proporcionou o isolamento e identificação de uma substância inédita da classe derivada da 2,5- dicetopiperazina, 3-benzilideno-2-metil-hexahidro-pirrolo [1,2-?] pirazina-1,4-diona (Sf3), e além desta, foram isolados mais quatro metabólitos como, os diasteroisômeros 1-fenil-1,2- propanediol (Sd2) e 1-fenil-1,2-propanediol (Sd3), 1,3-benzodioxole-5-metanol (Sc1), 1,2- propanodiol-1-(1,3-benzodioxol-5-il) (Se1). Ainda foi possível a desreplicação de substâncias via cromatografia gasosa acoplada à espectrometria de massas (CG-EM), entre elas o ácido palmítico, palmitato de metila, ácido metil linoléico, ácido oléico, álcool benzílico e o piperonal. Quanto ao estudo da atividade biológica, não foi observado potencial antibacteriano e antifúngico para os extratos e frações do fungo. Entretanto, notouse um potencial como fotoprotetor in vitro para as frações n-Hexano/AcOEt (2:3) e n- Hexano/AcOEt (1:4) obtidas a partir do extrato do cultivo de 28 dias do fungo A. stygium, extraído com solventes diclorometano/metanol (CH2Cl2/MeOH 2:1) e para a substância (Sf3) isolada do mesmo. Desta forma, o estudo químico e biológico do fungo Annulohypoxylon stygium demonstrou potencial para a produção de metabólitos secundários com atividade fotoprotetora, visto que uma estrutura inédita com esta atividade foi isolada e identificada como produto natural.
Resumo:
Considerando aspectos relacionados ao conforto térmico nas edificações e redução da demanda de energia para resfriamento, a utilização de revestimentos frios (que refletem boa parcela da radiação solar recebida e emitem calor) no envelope construtivo pode ser uma alternativa viável para alcançar estas condições. No entanto, a sua durabilidade é o caminho crítico. O presente estudo tem o objetivo de determinar a durabilidade de revestimento multifuncional que reúne as propriedades: fria e autolimpante. Para alcançar esta meta foi formulado um revestimento cimentício monocamada, com e sem a adição de pigmento, ambos com elevada refletância solar e emissividade iniciais. Para manter a refletância ao longo do tempo foi realizada a aplicação de TiO2 anatásio aos revestimentos de duas formas, na primeira as partículas foram adicionadas à matriz cimentícia, enquanto na segunda foram aplicadas superficialmente como pós-tratamento. A exposição à radiação UV proporciona a fotoativação do anatásio que possui capacidade de oxidação da matéria orgânica e alteração do ângulo de contato entre a água e a superfície, facilitando o arraste das sujidades quando esta é molhada tornando-a autolimpante. A manutenção das propriedades frias e a permanência das partículas de TiO2 sobre a superfície foram avaliadas após 6 e 12 meses de exposição natural em estações localizadas nas cidades de Ubatuba, Pirassununga e São Paulo. Após o envelhecimento observou-se a influência determinante das características dos sítios de exposição no comportamento dos materiais. Dentre as formas de aplicação do anatásio verificou-se uma melhora sutil no desempenho dos revestimentos com adição de TiO2 à matriz cimentícia em relação à aplicação superficial do pós-tratamento. O processo de lixiviação observado em ambos os revestimentos expôs as partículas encapsuladas na argamassa com adição de TiO2, enquanto no pós-tratamento houve a remoção da camada superficial de anatásio. Por esse motivo o revestimento com adição apresentou interação com a radiação UV e material a ser degradado por mais tempo. Entretanto os resultados sugeriram que o tempo de exposição foi insuficiente para afirmar este comportamento, pois os resultados são próximos entre si.