932 resultados para Flow rate variation coefficient
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
An analytical procedure for direct introduction of biodiesel samples into an inductively coupled plasma mass spectrometer (ICP-MS) by using microemulsion for sample preparation was developed here. Cadmium, Co, Cu, Mn, Ni, Pb, Ti, and Zn were determined in biodiesel microemulsified samples prepared from different oleaginous sources (African palm, castor beans, palm, soybeans and an unknown oleaginous). Microemulsions were prepared using 0.25 mL Triton X-100, 0.25 mL 20% v v(-1) HNO(3), 0.50 mL biodiesel sample and 4.0 mL n-propanol. Argon-oxygen mixture was added to the plasma as auxiliary gas for correcting matrix effects caused by the high carbon load due to biodiesel microemulsions. The oxygen gas flow rate was set in 37.5 mL min(-1). The accuracy of the developed procedure was evaluated by applying addition-recovery experiments for biodiesel samples from different sources. Recoveries varied from 76.5 to 116.2% for all analytes but Zn in castor beans biodiesel sample (65.0 to 76.2%). Recoveries lower than 86.6% were obtained for palm biodiesel sample, probably due to matrix effects. Detection limits calculated by using oxygen in the composition of the auxiliary gas added to the plasma were higher than those calculated without using it, probably due to the highest formation of oxides. Despite oxides formation, best analytical performance was reached by using oxygen as auxiliary gas and by proper correction of transport interferences. The developed procedure based on microemulsion formation was suitable for direct introduction of biodiesel samples in ICP-MS. (C) 2010 Elsevier B.V. All rights reserved.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
In this work, a fibrous cellulose obtained from the sugar cane bagasse was analysed about its binder/disintegrating action and about its interference degree in the dissolution rate ('in vitro') of active principles, when incorporated in a compact system that has a water-soluble drug. It was used as reference drug the Lithium Carbonate, considering its solubility in water and it difficulties in the compressibility and flow rate. That cellulose was evaluated in a comparative study, involving another fibrous cellulose generally used in the tablet obtainment (Microcel 3E-200). After the experiment in methodologies of dry granulation and wet granulation, it was concluded that the analysed celluloses presents adequate binder/disintegrating efficience and they are equivalents in these aspect.
Resumo:
The measurement of nitrogen dioxide at the parts-perbillion level is described. The experimental arrangement consists of two optical fibers placed on opposite sides of and in contact with a liquid film (14-57 μL in volume) supported on a U-shaped wire guide and two tubular conduits (one of which constitutes the means for the delivery of the liquid), light from a green (555 nm) light-emitting diode enters the liquid film, composed of Griess-Saltzman reagent. The transmitted light is measured by a referenced photodetection arrangement. Sample gas flows past the droplet at a low flow rate (typically 0.10-0.25 L/min). The response is proportional to the sampling period and the analyte concentration. The limit of detection for this nonoptimized arrangement is estimated to be <10 ppb by volume for a 5 min sample. Some unusual characteristics are observed. The initial absorbance, when most of the analyte/reaction product is still near the surface, is higher than that when the content of the droplet is fully mixed. The signal depends on the sample flow rate in a nonmonotonic fashion, first increasing and then decreasing with increasing sampling rate; the specific chemistry involved in the collection and determination of NO2 may be responsible.
Resumo:
Carboxymethylcellulose packed in to a glass column was used to pre-concentrate metallic cations from aqueous solutions. The pre-concentrated metal cations are directly eluted from the column using 5.0 mL of 1.0 mol L -1 hydrochloric acid. The optimum pre-concentration conditions are given (glass column, 16 cm length, 0.80 cm i.d., stationary phase height of 12 cm, flow-rate, 1.5 mL min -1). The recuperation efficiency achieved is greater than 95%, while the enrichment factor is 10 for 50 mL of solution (0.50 mg L -1 each).
Resumo:
The applicability of a residue of manioc (Manihot esculenta Granz) from industrial processing as a direct compression excipient was investigated in comparison with microcrystalline cellulose (Avicel® PH 101). Physical characteristics of the powders like bulk and tap densities, particle size, flow properties (flow rate, index of compressibility and angle of repose) and agglutination were evaluated. The residue had poor performance as excipient for direct compression. However, it showed better disintegration properties than Avicel. The possibility of its use as disintegrant agent will be confirmed on future studies.
Resumo:
The performance of a spray boom can be evaluated from its individual nozzle distribution patterns determined in a patternator (test table), as discussed by Perecin et al. (1994). The distribution pattern of three nozzle types obtained in a patternator at six heights were compared in order to propose a formula for determining the variation coefficient. The simulation of a spray boom was conducted from individual nozzle distribution patterns, and obtained the random variation coefficients (RVC) and the systematic variation coefficients (SVC). The results showed good performance of the TF-SV4 nozzles, with CV smaller than 10%, for nozzle spacing as large as 50 cm. The TQ15006 nozzles showed high variability in the central region of the distribution pattern, resulting in high CV from nozzle spacings as narrow as 25 cm. The TJ60-11006 behaved as intermediate between TF-VS4 and TQ15006. The formula proposed for determining the variation coefficient is [(RVC) 2+(SVC) 2] 1/2.
Resumo:
The aim of this study was to assess positive end-expiratory pressure (PEEP)-induced lung overdistension and alveolar recruitment in six patients with acute lung injury (ALI) using a computed tomographic (CT) scan method. Lung overdistension was first determined in six healthy volunteers in whom CT sections were obtained at FRC and at TLC with a positive airway pressure of 30 cm H2O. In patients, lung volumes were quantified by the analysis of the frequency distribution of CT numbers on the entire lung at zero end-expiratory pressure (ZEEP) and PEEP. In healthy volunteers at FRC, the distribution of the density histograms was monophasic with a peak at -791 ± 12 Hounsfield units (HU). The lowest CT number observed was -912 HU. At TLC, lung volume increased by 79 ± 35% and the peak CT number decreased to -886 ± 26 HU. More than 70% of the increase in lung volume was located below -900 HU, suggesting that this value can be considered as the threshold separating normal aeration from overdistension. In patients with ALI, at ZEEP the distribution of density histograms was either monophasic (n = 3) or biphasic (n = 3). The mean CT number was -319 ± 34 HU. At PEEP 13 ± 3 cm H2O, lung volume increased by 47 ± 19% whereas mean CT number decreased to -538 ± 171 HU. PEEP induced a mean alveolar recruitment of 320 ± 160 ml and a mean lung overdistension of 238 ± 320 ml. In conclusion, overdistended lung parenchyma of healthy volunteers is characterized by a CT number below -900 HU. This threshold can be used in patients with ALI for differentiating PEEP-induced alveolar recruitment from lung overdistension.
Resumo:
Objective: The present study was performed to investigate the influence of different routes of perfusion on the distribution of the preservation solutions in the lung parenchyma and upper airways. Methods: Pigs were divided into four groups: control (n = 6), pulmonary artery (PA) (n = 6), simultaneous PA + bronchial artery (BA) (n = 8), and retrograde delivery (n = 6). After preparation and cannulation, cardioplegia solution and Euro- Collins solution (ECS) for lung preservation were given simultaneously. After removal of the heart, the double lung bloc was harvested. Following parameters were assessed: total and regional perfusion (dye-labeled microspheres), tissue water content, PA, aorta, left atrial and left ventricular pressures, cardiac output and lung temperature. Results: Our data show that flow of the ECS in lung parenchyma did not reach control values (9.4 ± 1.0 ml/min per g lung wet weight) regardless of the route of delivery (PA 6.3 ± 1.5, PA + BA 4.8 ± 0.9, retrograde 2.7 ± 0.9 ml/min per g lung wet weight). However, flow in the proximal and distal trachea were significantly increased by PA + BA delivery (0.970 ± 0.4, respectively, 0.380 ± 0.2 ml/min per g) in comparison with PA (0.023 ± 0.007, respectively, 0.024 ± 0.070 ml/min per g), retrograde (0.009 ± 0.003, respectively, 0.021 ± 0.006 ml/min per g) and control experiments (0.125 ± 0.0018, respectively, 0.105 ± 0.012 ml/g per min). Similarly the highest flow rates in the right main bronchus were achieved by PA + BA delivery (1.04 ± 0.4 ml/min per g) in comparison with 0.11 ± 0.03 in control, 0.033 ± 0.008 in PA, and 0.019 ± 0.005 ml/min per g in retrograde group. Flows in the left main bronchus were 0.09 ± 0.02 ml/min per g in control, 0.045 ± 0.012 ml/min per g in PA, and 0.027 ± 0.006 ml/min per g in retrograde group. The flow rates were significantly (P = 0.001) increased by PA + BA delivery of the storage solution (0.97 ± 0.3 ml/min per g). Conclusions: Our data show that the distribution of ECS for lung preservation is significantly improved in airway tissues (trachea and bronchi) if a simultaneous PA + BA delivery is used.
Resumo:
Toxocariasis is caused by infection of man by Toxocara canis and Toxocara, cati larvae, the common roundworm of dogs and cats. Because larvae are difficult to detect in tissues, diagnosis is mostly based on serology. Non specific reactions are observed mainly due to cross-reactivity with Ascaris sp antigens. This investigation aimed at developing and evaluating an indirect antibody competition ELISA (IACE) employing a specific rabbit IgG anti-Toxocara canis excretory-secretory antigens as the competition antibody. in order to improve indirect ELISA specificity performed for toxocariasis diagnosis. For that, the rabbit IgG was previously absorbed by Ascaris suum adult antigens. Sensitivity and specificity of IACE were first evaluated in 28 serum samples of mice experimentally infected with T. canis embryonated eggs. Adopting cut-off value established in this population before infection, sensitivity and specificity were 100% after 20 days post-inoculation. For human population IACE was evaluated using sera from 440 patients with clinical signs of toxocariasis and the cut-off value was established with 60 serum samples from apparently healthy individuals. Using as reference test the indirect ELISA performed by Adolfo Lutz Institute, sensitivity was 60.2%, specificity was 98% and concordance was 77.3%. Repeatability of IACE was evaluated by the inter-reactions variation coefficient (2.4%).
Resumo:
This study evaluated the characteristics of spray produced by Yamaho nozzle tip'D'series. The droplet size of nozzle tips D3, D4, D5, D6 and D8 were evaluated at 703, 1.050, 1.406, 1.758, 2.110, 2.461 e 2.813 kPa pressures (100, 200, 250; 350, e 400 psi) by means of laser equipment, as well as the flow rate of nozzle tip at the pressures of 702, 1.125, 1.406, 1.828, 2.110, 2.532 e 2.813 kPa (100, 160, 200, 260,300; 360 e 400 psi) which were compared with values indicated by manufacturer. The droplet produced at all pressures presented a very fine spray, which in agriculture may promote losses by evaporation and drift. For all nozzle tips, except D8 in pressures 1.828, 2.532 e 2.813 kPa, the difference between the observed flow rate indicated by the manufacturer was higher than 5%. The paper demonstrates that the nozzle tip tested, in spite of not having uniform flow rate, may promote the contamination of spray operator and environment due to the droplet spectrum produced.