818 resultados para Fiber Optic Sensors in Quality evaluation
Resumo:
In the last few decades, there have been significant changes in the way people with intellectual disabilities (ID) live in many countries around the world. Large isolated institutions have been replaced by community-based housing. This study examined the deinstitutionalization process in Ontario and it's effects on the lives of three individuals with ID. A case analysis approach was used allowing for in depth evaluation of the quality of life of these participants following their discharge with a focus on family involvement, community engagement, and choice making. A discrepancy analysis between the Essential Elements Plan (EEP), constructed when they were entering the community placement, and the current living arrangements was also done. The results of this study suggested that with community living comes improvements in family interactions, community engagement, and decision-making. However, these improvements were found to be minimal. Also, little discrepancy was found between the EEPs and their actual placements.
Resumo:
The thesis describes the development and evaluation of epoxy resin as interfacial bonding agent for short Nylon-6 fiber elastomer composites. Epoxy resin is well known for its adhesive property. The potential use of it as interfacial bonding agent in short fiber composite is not explored yet. Three rubbers viz., acrylonitrile butadiene rubber (NBR), Neoprene rubber (CR) and styrene butadiene rubber (SBR) were selected and different fiber loading were tried. The resin concentration was optimized for each fiber loading with respect to cure characteristics and mechanical properties. Rheological characteristics and thermal degradation of the composites containing different fiber loading and different resin concentrations were studied in detail to find the effect of epoxy resin bonding system. The mechanical properties were studied in detail. The short Nylon -6 fiber improved most of the mechanical properties of all the three rubbers. Tensile strength showed a dip at 10 phr fiber loading in the case of CR while it was continuously increased with fiber loading in the case of NBR and SBR. All the composites showed anisotropy in mechanical properties. The epoxy resin is an effective bonding agent for short Nylon -6 fiber reinforced NBR and CR composites. Epoxy resin improved tensile strength, abrasion resistance and modulus of these composites. SEM studies confirmed the improved bonding of fiber and matrix in the presence of epoxy bonding agent. Epoxy resin was not effective as bonding agent in the case of short Nylon fiber- SBR composite. From the rheological studies of the composites with and without bonding agent it was observed that all the composite exhibited pseudoplasticity, which decreased with temperature. At higher shear rates all the mixes showed plug flow. SEM pictures showed that maximum orientation of fibers occured at a shear rate, just before the onset of plug flow. The presence of fiber reduced the temperature sensitivity of the flow at a given shear rate. Die swell was reduced in the presence of fiber. Shear viscosity of the composite was increased in the presence of resin. Die swell was increased in the presence of epoxy resin for composites at all shear rates. The thermal degradation of NBR and SBR composites with and without bonding agent followed single step degradation pattern. Thermal stability of the composites was improved in the presence of bonding agent. The degradation of virgin elastomer and the composites followed first order kinetics.
Resumo:
Discovery of coherent optical sources four decades ago has revolutionized all fields of scientific development. One of the path breaking applications of lasers is the emergence of various thermo optic techniques to unravel some of the mysteries of light matter interactions.Thermo optic technique is a valuable tool to evaluate optical and thermal properties of materials in solid,liquid and gaseous states .This technique can also be employed effectively in nondestructive quality evaluation. In this doctoral thesis , the use of photothermal techniques based on photoacoustic and photothermal deflection phenomena for the study of certain class of photonics materials such as semiconductors, nano metal dispersed ceramics, composites of conducting polymers and liquid crystals is elaborated.
Resumo:
We propose and demonstrate the possibility of using a permanently microbent bare optical fiber for detecting chemical species. Two detection schemes, viz., a bright-field detection scheme (for the core modes), and a dark-field detection scheme (for the cladding modes) have been employed to produce a fiber-optic sensor. The sensor described here is sensitive enough to detect concentrations as low as nanomoles per liter of a chemical species, with a dynamic range of more than 6 orders of magnitude.
Resumo:
The application of computer vision based quality control has been slowly but steadily gaining importance mainly due to its speed in achieving results and also greatly due to its non- destnictive nature of testing. Besides, in food applications it also does not contribute to contamination. However, computer vision applications in quality control needs the application of an appropriate software for image analysis. Eventhough computer vision based quality control has several advantages, its application has limitations as to the type of work to be done, particularly so in the food industries. Selective applications, however, can be highly advantageous and very accurate.Computer vision based image analysis could be used in morphometric measurements of fish with the same accuracy as the existing conventional method. The method is non-destructive and non-contaminating thus providing anadvantage in seafood processing.The images could be stored in archives and retrieved at anytime to carry out morphometric studies for biologists.Computer vision and subsequent image analysis could be used in measurements of various food products to assess uniformity of size. One product namely cutlet and product ingredients namely coating materials such as bread crumbs and rava were selected for the study. Computer vision based image analysis was used in the measurements of length, width and area of cutlets. Also the width of coating materials like bread crumbs was measured.Computer imaging and subsequent image analysis can be very effectively used in quality evaluations of product ingredients in food processing. Measurement of width of coating materials could establish uniformity of particles or the lack of it. The application of image analysis in bacteriological work was also done
Resumo:
The paper ‘Impact of Quality on Ethics and Social Responsibility in Marketing in Industries in Kerala in the present Indian scenario’ highlights the observations, based on a descriptive research carried out in five leading industries in Kerala, in the private and public sector. Ethics and social responsibilities, practiced in these industries, are reflected in the results of the survey conducted on specific queries like awareness of products/services provided by them, total understanding of the requirements of the customer, open discussion on technical matters, accountability of employees to the society and social needs, consumer ethics vis a vis business ethics etc. Team working goes a long way, in building relations, which in turn, results in a progressive and effective marketing strategy. This assumes paramount importance, considering the severe competition we are facing in the light of liberalization, privatization and globalization, which encompasses the globe. The prediction of India becoming a lead nation, along with USA, China and Japan, in this decade, can get fructified only if we follow a very high standards of ethics and social responsibility, in all domains including marketing. Organizations like TRW.Rane, Sundaram Fasteners, TVS Motors, in Chennai are a few among others in India, who have achieved the highest distinction in quality viz Deming Prize, and these demonstrate their commitment to quality, society and humanity at large. Cost effectiveness, without jeopardizing quality has become the need of the hour and MRTP has become history. This trait is being brought out through the survey and the results speak for themselves. Unethical practices like switch and bait, not only brings shame to the organization, and country but also results in the company getting wiped out from the market. Adherence to standards like ISO 14000 helps to maintain the minimum level of social responsibility and environmental friendliness. Like quality audit, safety audit etc, social audit is being insisted in all progressive countries to ensure that the organization comply with the minimum statutory requirements. The paper also touches upon Corporate Social Responsibility practiced in the industries and this becomes crystal clear through their commitment to improve the community. Green Marketing lays a lot of importance on the three Rs of environmentalism viz Reduce, Reuse and Recycle. The objective of any business is to achieve optimal profit and this is possible only by reducing the cost as well as waste. In this context, management tools like brainstorming, suggestion schemes, benchmarking etc becomes helpful. These characteristics are brought out through the analysis of survey results. The conclusions drawn throw a lot of information on the desirable practices with respect to Ethics and Social Responsibility in Marketing
Resumo:
Die Wechselwirkungen zwischen Biomolekülen spielen eine zentrale Rolle in der biochemischen und pharmazeutischen Forschung. In der biomolekularen Interaktionsanalyse sind dabei Biosensoren auf Basis des Oberflächenplasmonresonanzeffekts (SPR-Effekt) weitverbreitet. Seit Einführung der ersten kommerziellen SPR-Biosensoren Anfang der 1990er Jahre wurden verschiedenste Messanordnungen sowie Materialsysteme mit dem Ziel einer möglichst hohen Empfindlichkeit getestet. Eine Möglichkeit zur Steigerung der Empfindlichkeit klassischer SPR-Systeme bieten sogenannte magneto-optische SPR-Biosensoren (MOSPR-Biosensoren). Grundlage der Empfindlichkeitssteigerung ist die gleichzeitige Messung des SPR-Effekts und des transversalen magneto-optischen KERR-Effekts (tMOKE). Bisherige Untersuchungen haben sich meist auf den Einfluss der Magnetisierung freier ferromagnetischer Schichten beschränkt. Im Rahmen dieser Arbeit wurden erstmals austauschverschobene Dünnschichtsysteme (EB-Systeme), eine Kombination aus Ferromagnet und Antiferromagnet, hinsichtlich ihrer Eignung für SPR- und MOSPR-basierte biosensorische Anwendungen untersucht. Aufgrund der remanenten Magnetisierung der ferromagnetischen Schicht und ihrer magnetischen Strukturierbarkeit sind EB-Systeme eine hochinteressante Plattform zur Realisierung neuer Biosensorkonzepte. Zur Reduzierung der stark dämpfendenden Wirkung magnetischer Materialien wurde das hier betrachtete IrMn/Co EB-System zwischen zwei Goldschichten eingebettet. Eine Gegenüberstellung optimierter Au/ IrMn/Co/Au-Systeme mit einem reinen Au-System, wie es typischerweise in kommerziellen SPR-basierten Biosensoren eingesetzt wird, demonstriert, dass mit den entwickelten EB-Systemen vergleichbare Empfindlichkeiten in SPR-Sensor-Anwendungen erreicht werden können. Die magneto-optische Aktivität der untersuchten Dünnschichtsysteme liegt im Bereich der Literaturwerte für Au/Co/Au-Systeme, mit denen erhöhte Empfindlichkeiten gegenüber Standard-SPR-Biosensoren realisiert wurden. Auf Grundlage magnetisch strukturierter Au/IrMn/Co/Au-Systeme wurden neue Biosensorkonzepte entwickelt und getestet. Erste Experimente belegen, dass mit diesen Schichtsystemen eine gleichzeitige Detektion der magnetisierungsabhängigen Reflektivitäten in ortsauflösenden MOSPR-Messungen möglich ist. Eine solche Messanordnung profitiert von der erhöhten Empfindlichkeit MOSPR-basierter Biosensoren, hohen Messgeschwindigkeiten und einem verbesserten Signal-Rausch-Verhältnis. Weiterhin wurde der domänenwandassistierte Transport (DOWMAT) superparamagnetischer Partikel über der Oberfläche eines exemplarischen EB-Systems, zur Sensorintegration von Misch-, Reinigungs- und Aufkonzentrationsfunktionen erfolgreich getestet. Die Ergebnisse demonstrieren, dass ein Transport von Partikelreihen mit hohen Geschwindigkeiten bei moderaten externen Magnetfeldern über den entwickelten Schichtsystemen möglich ist. Die Agglomeration der Partikel wird dabei intrinsisch vermieden. Diese Beobachtungen verdeutlichen die Vorzüge des DOWMAT-Mechanismus für biosensorische Anwendungen. Die präsentierten Untersuchungen bilden die Grundlage auf dem Weg zur Umsetzung neuer vielversprechender Biosensorkonzepte, die eine Schlüsselfunktion in der medizinischen point-of-care-Diagnostik bei der Detektion kleinster Konzentrationen krankheitsrelevanter Biomarker einnehmen können.
Resumo:
Introducción: El glaucoma representa la tercera causa de ceguera a nivel mundial y un diagnóstico oportuno requiere evaluar la excavación del nervio óptico que está relacionada con el área del mismo. Existen reportes de áreas grandes (macrodiscos) que pueden ser protectoras, mientras otros las asocian a susceptibilidad para glaucoma. Objetivo: Establecer si existe asociación entre macrodisco y glaucoma en individuos estudiados con Tomografía Optica Coherente (OCT ) en la Fundación Oftalmológica Nacional. Métodos: Estudio transversal de asociación que incluyó 25 ojos con glaucoma primario de ángulo abierto y 74 ojos sanos. A cada individuo se realizó examen oftalmológico, campo visual computarizado y OCT de nervio óptico. Se compararon por grupos áreas de disco óptico y número de macrodiscos, definidos según Jonas como un área de la media más dos desviaciones estándar y según Adabache como área ≥3.03 mm2 quien evaluó población Mexicana. Resultados: El área promedio de disco óptico fue 2,78 y 2,80 mm2 glaucoma Vs. sanos. De acuerdo al criterio de Jonas, se observó un macrodisco en el grupo sanos y según criterio de Adabache se encontraron ocho y veinticinco macrodiscos glaucoma Vs. sanos. (OR=0,92 IC95%=0.35 – 2.43). Discusión: No hubo diferencia significativa (P=0.870) en el área de disco entre los dos grupos y el porcentaje de macrodiscos para los dos grupos fue similar, aunque el bajo número de éstos no permitió concluir en términos estadísticos sobre la presencia de macrodisco y glaucoma.