998 resultados para EMISSION-LINE


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Os autores relatam pela primeira vez utilização de uma nova partícula para embolização, constituída de um núcleo de acetato de polivinil revestido por polivinil-álcool, de forma esférica (Spherus®-First Line Brasil), como preparo pré-operatório em três pacientes portadores de neoplasia renal, na intenção de diminuir o tamanho do tumor e prevenir complicações hemorrágicas durante o ato operatório. Estas novas partículas foram projetadas e elaboradas nos laboratórios da COPPE/UFRJ. A embolização intra-arterial pré-operatória com estas novas partículas ocasionou acentuada isquemia em todo o tecido tumoral facilitando o procedimento cirúrgico.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Glass is a unique material with a long history. Several glass products are used daily in our everyday life, often unnoticed. Glass can be found not only in obvious applications such as tableware, windows, and light bulbs, but also in tennis rackets, windmill turbine blades, optical devices, and medical implants. The glasses used at present as implants are inorganic silica-based melt-derived compositions mainly for hard-tissue repair as bone graft substitute in dentistry and orthopedics. The degree of glass reactivity desired varies according to implantation situation and it is vital that the ion release from any glasses used in medical applications is controlled. Understanding the in vitro dissolution rate of glasses provides a first approximation of their behavior in vivo. Specific studies concerning dissolution properties of bioactive glasses have been relatively scarce and mostly concentrated to static condition studies. The motivation behind this work was to develop a simple and accurate method for quantifying the in vitro dissolution rate of highly different types of glass compositions with interest for future clinical applications. By combining information from various experimental conditions, a better knowledge of glass dissolution and the suitability of different glasses for different medical applications can be obtained. Thus, two traditional and one novel approach were utilized in this thesis to study glass dissolution. The chemical durability of silicate glasses was tested in water and TRIS-buffered solution at static and dynamic conditions. The traditional in vitro testing with a TRISbuffered solution under static conditions works well with bioactive or with readily dissolving glasses, and it is easy to follow the ion dissolution reactions. However, in the buffered solution no marked differences between the more durable glasses were observed. The hydrolytic resistance of the glasses was studied using the standard procedure ISO 719. The relative scale given by the standard failed to provide any relevant information when bioactive glasses were studied. However, the clear differences in the hydrolytic resistance values imply that the method could be used as a rapid test to get an overall idea of the biodegradability of glasses. The standard method combined with the ion concentration and pH measurements gives a better estimate of the hydrolytic resistance because of the high silicon amount released from a glass. A sensitive on-line analysis method utilizing inductively coupled plasma optical emission spectrometer and a flow-through micro-volume pH electrode was developed to study the initial dissolution of biocompatible glasses. This approach was found suitable for compositions within a large range of chemical durability. With this approach, the initial dissolution of all ions could be measured simultaneously and quantitatively, which gave a good overall idea of the initial dissolution rates for the individual ions and the dissolution mechanism. These types of results with glass dissolution were presented for the first time during the course of writing this thesis. Based on the initial dissolution patterns obtained with the novel approach using TRIS, the experimental glasses could be divided into four distinct categories. The initial dissolution patterns of glasses correlated well with the anticipated bioactivity. Moreover, the normalized surface-specific mass loss rates and the different in vivo models and the actual in vivo data correlated well. The results suggest that this type of approach can be used for prescreening the suitability of novel glass compositions for future clinical applications. Furthermore, the results shed light on the possible bioactivity of glasses. An additional goal in this thesis was to gain insight into the phase changes occurring during various heat treatments of glasses with three selected compositions. Engineering-type T-T-T curves for glasses 1-98 and 13-93 were stablished. The information gained is essential in manufacturing amorphous porous implants or for drawing of continuous fibers of the glasses. Although both glasses can be hot worked to amorphous products at carefully controlled conditions, 1-98 showed one magnitude greater nucleation and crystal growth rate than 13-93. Thus, 13-93 is better suited than 1-98 for working processes which require long residence times at high temperatures. It was also shown that amorphous and partially crystalline porous implants can be sintered from bioactive glass S53P4. Surface crystallization of S53P4, forming Na2O∙CaO∙2SiO2, was observed to start at 650°C. The secondary crystals of Na2Ca4(PO4)2SiO4, reported for the first time in this thesis, were detected at higher temperatures, from 850°C to 1000°C. The crystal phases formed affected the dissolution behavior of the implants in simulated body fluid. This study opens up new possibilities for using S53P4 to manufacture various structures, while tailoring their bioactivity by controlling the proportions of the different phases. The results obtained in this thesis give valuable additional information and tools to the state of the art for designing glasses with respect to future clinical applications. With the knowledge gained we can identify different dissolution patters and use this information to improve the tuning of glass compositions. In addition, the novel online analysis approach provides an excellent opportunity to further enhance our knowledge of glass behavior in simulated body conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVO: Foi testar a validade e a confiabilidade de uma versão on-line do Female Sexual Function Index (FSFI). MÉTODOS: Uma versão on-line do FSFI foi comparada à versão tradicional, em papel. Para tanto, estudantes de Fisioterapia de três cidades foram alocadas randomicamente em dois grupos - G-pp/ol (n=126) e G-ol/pp (n=147). As mulheres do G-pp/ol responderam ao FSFI do modo tradicional, em papel e caneta, enquanto o G-ol/pp respondeu a uma versão on-line do mesmo questionário. Após 15 dias de intervalo, houve nova coleta, quando o G-pp/ol respondeu a versão on-line enquanto o G-ol/pp respondeu no papel. Todos os dados foram transportados para o software estatístico SPSS. Diferenças demográficas entre os dois grupos foram reveladas pelo teste t de Student ou pelo teste exato de Fischer (IC95%; p>0,05). A associação e a correlação entre as respostas entre G-pp/ol e G-ol/pp durante cada coleta foram acessadas pelo teste t e o coeficiente de Pearson. Estratégia idêntica foi utilizada para as comparações intragrupo. RESULTADOS: Um total de 273 mulheres participou do estudo e 28 (10,2%) desistiram da segunda coleta. Não houve diferenças demográficas entre os grupos. Houve associação entre 15 das 19 questões do FSFI entre os dois grupos, tanto no teste quanto no reteste. A análise intragrupo revelou que todas as questões e os escores do FSFI estiveram associados, mas fracamente correlacionados para um mesmo grupo durante as duas coletas. CONCLUSÃO: A versão on-line do FSFI apresentou validade e confiabilidade aceitáveis quando comparada à versão em papel, o que pode justificar a opção por essa modalidade, especialmente em estudos envolvendo sexualidade.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSES: To determine the basic expression of ABC transporters in an epithelial ovarian cancer cell line, and to investigate whether low concentrations of acetaminophen and ibuprofen inhibited the growth of this cell line in vitro. METHODS: TOV-21 G cells were exposed to different concentrations of acetaminophen (1.5 to 15 μg/mL) and ibuprofen (2.0 to 20 μg/mL) for 24 to 48 hours. The cellular growth was assessed using a cell viability assay. Cellular morphology was determined by fluorescence microscopy. The gene expression profile of ABC transporters was determined by assessing a panel including 42 genes of the ABC transporter superfamily. RESULTS: We observed a significant decrease in TOV-21 G cell growth after exposure to 15 μg/mL of acetaminophen for 24 (p=0.02) and 48 hours (p=0.01), or to 20 μg/mL of ibuprofen for 48 hours (p=0.04). Assessing the morphology of TOV-21 G cells did not reveal evidence of extensive apoptosis. TOV-21 G cells had a reduced expression of the genes ABCA1, ABCC3, ABCC4, ABCD3, ABCD4 and ABCE1 within the ABC transporter superfamily. CONCLUSIONS: This study provides in vitro evidence of inhibitory effects of growth in therapeutic concentrations of acetaminophen and ibuprofen on TOV-21 G cells. Additionally, TOV-21 G cells presented a reduced expression of the ABCA1, ABCC3, ABCC4, ABCD3, ABCD4 and ABCE1 transporters.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tumour cells differ from normal tissue cells in several important ways. These differences, like for example changed energy metabolism, result in altered microenvironment of malignant tumours. Non-invasive imaging of tumour microenvironment has been at the centre of intense research recently due to the important role that this changed environement plays in the development of malignant tumours and due to the role it plays in the treatment of these tumours. In this respect, perhaps the most important characteristics of the tumour microenvironment from this point of view are the lack of oxygen or hypoxia and changes in blood flow (BF). The purpose of this thesis was to investigate the processes of energy metabolism, BF and oxygenation in head and neck cancer and pancreatic tumours and to explore the possibilities of improving the methods for their quantification using positron emission tomography (PET). To this end [18F]EF5, a new PET tracer for detection of tumour hypoxia was investigated. Favourable uptake properties of the tracer were observed. In addition, it was established that the uptake of this tracer does not correlate with the uptake of existing tracers for the imaging of energy metabolism and BF, so the information about the presence of tissue hypoxia cannot therefore be obtained using tracers such as [18F]FDG or [15O]H2O. These results were complemented by the results of the follow-up study in which it was shown that the uptake of [18F]EF5 in head and neck tumours prior to treatment is also associated with the overall survival of the patients, indicating that tumour hypoxia is a negative prognostic factor and might be associated with therapeutic resistance. The influences of energy metabolism and BF on the survival of patients with pancreatic cancer were investigated in the second study. The results indicate that the best predictor of survival of patients with pancreatic cancer is the relationship between energy metabolism and BF. These results suggest that the cells with high metabolic activity in a hypoperfused tissue have the most aggressive phenotype.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this thesis, the DFMA is presented and used for the purpose of having a design for a vertical transfer line that can be easily manufactured and assembled. The design of the transfer line, the major components and drawings are presented. The ease of assembly, the costs of manufacturing and differences between the use of steel structure and aluminum are compared. The ALARA principle is followed to minimize the risk of radiation exposure by the means of locating the test ion sources outside the radioactive area.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to investigate the suitability of the Finnish Defence Forces’ NH90 helicopter for parachuting operations with the T-10 static line parachute system. The work was based on the Army Command’s need to compensate for the reduction in the outsourced flight hours for the military static line parachuting training. The aim of the research was to find out the procedures and limitations with which the NH90 IOC+ or FOC version helicopter could be used for static line parachutist training with the T-10B/MC1-1C parachutes. The research area was highly complicated and non-linear. Thus analytical methods could not be applied with sufficient confidence, even with present-day computing power. Therefore an empirical research method was selected, concentrating on flight testing supported with literature study and some calculated estimations. During three flights and 4.5 flight hours in Utti, Finland on 1720 September 2012, a total of 44 parachute drops were made. These consisted of 16 dummy drops and 28 paratrooper jumps. The test results showed that when equipped with the floor mounted PASI-1 anchor line, the deflector bar of the NHIndustries’ Parachuting Kit and Patria’s floor protection panels the Finnish NH90 variant could be safely used for T-10B/MC1-1C static line parachuting operations from the right cabin door at airspeed range of 5080 KIAS (90–150 km/h). The ceiling mounted anchor lines of the NHI’s Parachuting Kit were not usable with the T-10 system. This was due to the static lines’ unsafe behaviour in slipstream when connected to the cabin ceiling level. In conclusion, the NH90 helicopter can be used to meet the Army Command’s requirement for an additional platform for T-10 static line parachutist training. Material dropping, the effect of additional equipment and jumping from the rear ramp should be further studied.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of the present paper is to study the relationship between the fracture modes in hydrogen-assisted cracking (HAC) in microalloied steel and the emission of acoustic signals during the fracturing process. For this reason, a flux-cored arc weld (FCAW) was used in a high-strength low-alloy steel. The consumable used were the commercially available AWS E120T5-K4 and had a diameter of 1.6 mm. Two different shielding gases were used (CO2 and CO2+5% H2) to obtain complete phenomenon characterization. The implant test was applied with three levels of restriction stresses. An acoustic emission measurement system (AEMS) was coupled to the implant test apparatus. The output signal from the acoustic emission sensor was passed through an electronic amplifier and processed by a root mean square (RMS) voltage converter. Fracture surfaces were examined by scanning electron microscopy (SEM) and image analysis. Fracture modes were related with the intensity, the energy and the number of the peaks of the acoustic emission signal. The shielding gas CO2+5% H2 proved to be very useful in the experiments. Basically, three different fracture modes were identified in terms of fracture appearance: microvoid coalescence (MVC), intergranular (IG) and quasi-cleavage (QC). The results show that each mode of fracture presents a characteristic acoustic signal.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Communications play a key role in modern smart grids. New functionalities that make the grids ‘smart’ require the communication network to function properly. Data transmission between intelligent electric devices (IEDs) in the rectifier and the customer-end inverters (CEIs) used for power conversion is also required in the smart grid concept of the low-voltage direct current (LVDC) distribution network. Smart grid applications, such as smart metering, demand side management (DSM), and grid protection applied with communications are all installed in the LVDC system. Thus, besides remote connection to the databases of the grid operators, a local communication network in the LVDC network is needed. One solution applied to implement the communication medium in power distribution grids is power line communication (PLC). There are power cables in the distribution grids, and hence, they may be applied as a communication channel for the distribution-level data. This doctoral thesis proposes an IP-based high-frequency (HF) band PLC data transmission concept for the LVDC network. A general method to implement the Ethernet-based PLC concept between the public distribution rectifier and the customerend inverters in the LVDC grid is introduced. Low-voltage cables are studied as the communication channel in the frequency band of 100 kHz–30 MHz. The communication channel characteristics and the noise in the channel are described. All individual components in the channel are presented in detail, and a channel model, comprising models for each channel component is developed and verified by measurements. The channel noise is also studied by measurements. Theoretical signalto- noise ratio (SNR) and channel capacity analyses and practical data transmission tests are carried out to evaluate the applicability of the PLC concept against the requirements set by the smart grid applications in the LVDC system. The main results concerning the applicability of the PLC concept and its limitations are presented, and suggestion for future research proposed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this research was to provide a deeper insight into the consequences of electronic human resource management (e-HRM) for line managers. The consequences are viewed as used information system (IS) potentials pertaining to the moderate voluntaristic category of consequences. Due to the need to contextualize the research and draw on line managers’ personal experiences, a qualitative approach in a case study setting was selected. The empirical part of the research is loosely based on literature on HRM and e-HRM and it was conducted in an industrial private sector company. In this thesis, method triangulation was utilized, as nine semi-structured interviews, conducted in a European setting, created the main method for data collection and analysis. Other complementary data such as HRM documentation and statistics of e-HRM system usage were utilized as background information to help to put the results into context. E-HRM has partly been taken into use in the case study company. Line managers tend to use e-HRM when a particular task requires it, but they are not familiar with all the features and possibilities which e-HRM has to offer. The advantages of e-HRM are in line with the company’s goals. The advantages are e.g. an transparency of data, process consistency, and having an efficient and easy-to-use tool at one’s disposal. However, several unintended, even contradictory, and mainly negative outcomes can also be identified, such as over-complicated processes, in-security in use of the tool, and the lack of co-operation with HR professionals. The use of e-HRM and managers’ perceptions regarding e-HRM affect the way in which managers perceive the consequences of e-HRM on their work. Overall, the consequences of e-HRM are divergent, even contradictory. The managers who considered e-HRM mostly beneficial to their work found that e-HRM affects their work by providing information and increasing efficiency. Those managers who mostly perceived challenges in e-HRM did not think that e-HRM had affected their role or their work. Even though the perceptions regarding e-HRM and its consequences might reflect the strategies, the distribution of work, and the ways of working in all HRM in general and can’t be generalized as such, this research contributed to the field of e-HRM and it provides new perspectives to e-HRM in the case study organization and in the academic field in general.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Positron Emission Tomography (PET) using 18F-FDG is playing a vital role in the diagnosis and treatment planning of cancer. However, the most widely used radiotracer, 18F-FDG, is not specific for tumours and can also accumulate in inflammatory lesions as well as normal physiologically active tissues making diagnosis and treatment planning complicated for the physicians. Malignant, inflammatory and normal tissues are known to have different pathways for glucose metabolism which could possibly be evident from different characteristics of the time activity curves from a dynamic PET acquisition protocol. Therefore, we aimed to develop new image analysis methods, for PET scans of the head and neck region, which could differentiate between inflammation, tumour and normal tissues using this functional information within these radiotracer uptake areas. We developed different dynamic features from the time activity curves of voxels in these areas and compared them with the widely used static parameter, SUV, using Gaussian Mixture Model algorithm as well as K-means algorithm in order to assess their effectiveness in discriminating metabolically different areas. Moreover, we also correlated dynamic features with other clinical metrics obtained independently of PET imaging. The results show that some of the developed features can prove to be useful in differentiating tumour tissues from inflammatory regions and some dynamic features also provide positive correlations with clinical metrics. If these proposed methods are further explored then they can prove to be useful in reducing false positive tumour detections and developing real world applications for tumour diagnosis and contouring.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to investigate the suitability of the Finnish Defence Forces’ NH90 helicopter for parachuting operations with the T-10 static line parachute system. The work was based on the Army Command’s need to compensate for the reduction in the outsourced flight hours for the military static line parachuting training. The aim of the research was to find out the procedures and limitations with which the NH90 IOC+ or FOC version helicopter could be used for static line parachutist training with the T- 10B/MC1-1C parachutes. The research area was highly complicated and non-linear. Thus analytical methods could not be applied with sufficient confidence, even with present-day computing power. Therefore an empirical research method was selected, concentrating on flight testing supported with literature study and some calculated estimations. During three flights and 4.5 flight hours in Utti, Finland on 17−20 September 2012, a total of 44 parachute drops were made. These consisted of 16 dummy drops and 28 paratrooper jumps. The test results showed that when equipped with the floor mounted PASI-1 anchor line, the deflector bar of the NHIndustries’ Parachuting Kit and Patria’s floor protection panels the Finnish NH90 variant could be safely used for T-10B/MC1-1C static line parachuting operations from the right cabin door at airspeed range of 50−80 KIAS (∼90–150 km/h). The ceiling mounted anchor lines of the NHI’s Parachuting Kit were not usable with the T-10 system. This was due to the static lines’ unsafe behaviour in slipstream when connected to the cabin ceiling level. In conclusion, the NH90 helicopter can be used to meet the Army Command’s requirement for an additional platform for T-10 static line parachutist training. Material dropping, the effect of additional equipment and jumping from the rear ramp should be further studied.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Biopolttoaineet ovat tärkeä energianlähde suomalaisessa energiantuotannossa. Biopoltto- aineille on kuitenkin ominaista laadun vaihtelevuus. Yksi tärkeimmistä laatutekijöistä on kosteus, joka vaikuttaa myös polttoaineen energiasisältöön. Laatutekijät puolestaan vai- kuttavat polttoainekäsittelyyn, polttoprosessiin ja koko laitoksen hyötysuhteeseen. Tämän työn tarkoituksena oli tutkia voisiko biopolttoaineiden online-laadunmittaus tuoda lisäarvoa energiantuotantolaitokselle. Esimerkkinä käytettiin yhtä online-laadunmittaus- sovellusta, InrayFuel-röntgenmittausjärjestelmää. Sillä voidaan seurata biopolttoaineiden kosteutta ja polttoaineen sisältämiä vierasaineita. Työssä on laadittu kustannusanalyysi, jolla pyritään selvittämään, onko nykyisen kertaluontoisen mittausmenetelmän korvaami- nen jatkuvatoimisella kannattavaa. Esimerkkilaitoksena on Etelä-Savon Energian Pur- sialan voimalaitos, jossa röntgenmittausjärjestelmään on testattu. Saatujen tulosten mukaan investoiminen esimerkkimittausjärjestelmään maksaisi itsensä takaisin alle vuodessa. Kun laitoksella pystytään seuraamaan polttoaineen laatua jatkuva- toimisesti, laadunhallinta paranee ja sitä kautta voidaan saavuttaa kustannussäästöjä. Polt- toaineesta johtuvat häiriötilanteet vähenevät, polttoaine on mahdollista optimoida edulli- semmaksi polton kannalta ja poltto-olosuhteita voidaan säätää paremmin, jolloin päästöt vähenevät ja hyötysuhde kasvaa. Työssä käytetty laskenta analysoi kuitenkin hyvin ylei- sellä tasolla, sillä käytössä ei ollut laitoksen omaa taselaskentajärjestelmää. Laskenta siis sisältää paljon oletuksia. Tämän ja rohkaisevien tulosten vuoksi tutkimusta jatkuvatoimi- sen laadunmittauksen hyödyistä kannattaa tehdä enemmän.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Valuable minerals can be recovered by using froth flotation. This is a widely used separation technique in mineral processing. In a flotation cell hydrophobic particles attach on air bubbles dispersed in the slurry and rise on the top of the cell. Valuable particles are made hydrophobic by adding collector chemicals in the slurry. With the help of a frother reagent a stable froth forms on the top of the cell and the froth with valuable minerals, i.e. the concentrate, can be removed for further processing. Normally the collector is dosed on the basis of the feed rate of the flotation circuit and the head grade of the valuable metal. However, also the mineral composition of the ore affects the consumption of the collector, i.e. how much is adsorbed on the mineral surfaces. Therefore it is worth monitoring the residual collector concentration in the flotation tailings. Excess usage of collector causes unnecessary costs and may even disturb the process. In the literature part of the Master’s thesis the basics of flotation process and collector chemicals are introduced. Capillary electrophoresis (CE), an analytical technique suitable for detecting collector chemicals, is also reviewed. In the experimental part of the thesis the development of an on-line CE method for monitoring the concentration of collector chemicals in a flotation process and the results of a measurement campaign are presented. It was possible to determine the quality and quantity of collector chemicals in nickel flotation tailings at a concentrator plant with the developed on-line CE method. Sodium ethyl xanthate and sodium isopropyl xanthate residuals were found in the tailings and slight correlation between the measured concentrations and the dosage amounts could be seen.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Työn tilaajana toimi Visedo Oy. Työn tavoitteina oli tutkia Visedo Oy:n ohjelmistokehityksen nykytila, tunnistaa seuraavat parannuskohteet ja antaa ohjeita havaittujen parannuskohteiden korjaamiseksi. Visedo Oy:n tehonmuokkain ohjelmistokehityksen nykytilaa käsiteltiin neljän valitun osa-alueen näkökulmasta: ohjelmistoarkkitehtuurityyli, komponenttipohjainen ohjelmistokehitys, ohjelmistotuotelinjojen kehitysmenetelmät ja ohjelmistovariaatioiden hallinta. Valituilla osa-alueilla havaittujen parannuskohteiden perusteella annettiin korjausehdotuksia: ohjelmistoarkkitehtuurin rakenteeseen, komponenttien jakautumiselle, komponenttien koostamiselle ja komponenttien versioinnille. Lisäksi ehdotettiin uudenlaista ohjelmistotuotelinja rakennetta, joka yhdistää kerros- ja komponenttipohjaiset arkkitehtuurityylit mahdollistaen ominaisuuksiltaan eroavien tehonmuokkain ohjelmistojen hallinnan.