Using a unique set of data and exploiting a large-scale natural experiment, we estimate the effect of real-time usage information on residential electricity consumption in Northern Ireland. Starting in April 2002, the utility replaced prepayment meters with advanced meters that allow the consumer to track usage in real-time. We rely on this event, account for the endogeneity of price and payment plan with consumption through a plan selection correction term, and find that the provision of information is associated with a decline in electricity consumption of 11-17%. We find that the reduction is robust to different specifications, selection-bias correction methods and subsamples of the original data. The advanced metering program delivers reasonably cost-effective reductions in carbon dioxide emissions, even under the most conservative usage reduction scenarios.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper describes how worst-case error analysis can be applied to solve some of the practical issues in the development and implementation of a low power, high performance radix-4 FFT chip for digital video applications. The chip has been fabricated using a 0.6 µm CMOS technology and can perform a 64 point complex forward or inverse FFT on real-time video at up to 18 Megasamples per second. It comprises 0.5 million transistors in a die area of 7.8×8 mm and dissipates 1 W, leading to a cost-effective silicon solution for high quality video processing applications. The analysis focuses on the effect that different radix-4 architectural configurations and finite wordlengths has on the FFT output dynamic range. These issues are addressed using both mathematical error models and through extensive simulation.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Details of a new low power FFT processor for use in digital television applications are presented. This has been fabricated using a 0.6 µm CMOS technology and can perform a 64 point complex forward or inverse FFT on real-rime video at up to 18 Megasamples per second. It comprises 0.5 million transistors in a die area of 7.8×8 mm and dissipates 1 W. Its performance, in terms of computational rate per area per watt, is significantly higher than previously reported devices, leading to a cost-effective silicon solution for high quality video processing applications. This is the result of using a novel VLSI architecture which has been derived from a first principles factorisation of the DFT matrix and tailored to a direct silicon implementation.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background. There is increasing global interest in regional palliative care networks (PCN) to integrate care, creating systems that are more cost-effective and responsive in multi-agency settings. Networks are particularly relevant where different professional skill sets are required to serve the broad spectrum of end-of-life needs. We propose a comprehensive framework for evaluating PCNs, focusing on the nature and extent of inter-professional collaboration, community readiness, and client-centred care. Methods. In the absence of an overarching structure for examining PCNs, a framework was developed based on previous models of health system evaluation, explicit theory, and the research literature relevant to PCN functioning. This research evidence was used to substantiate the choice of model factors. Results. The proposed framework takes a systems approach with system structure, process of care, and patient outcomes levels of consideration. Each factor represented makes an independent contribution to the description and assessment of the network. Conclusions. Realizing palliative patients' needs for complex packages of treatment and social support, in a seamless, cost-effective manner, are major drivers of the impetus for network-integrated care. The framework proposed is a first step to guide evaluation to inform the development of appropriate strategies to further promote collaboration within the PCN and, ultimately, optimal palliative care that meets patients' needs and expectations. © 2010 Bainbridge et al; licensee BioMed Central Ltd.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper presents a detailed description of health care resource utilisation and costs of a pilot interdisciplinary health care model of palliative home care in Ontario, Canada. The descriptive evaluation entailed examining the use of services and costs of the pilot program: patient demographics, length of stay broken down by disposition (discharged, alive, death), access to services/resources, use of family physician and specialist services, and drug use. There were 434 patients included in the pilot program. Total costs were approximately CAN$2.4 million, and the cost per person amounted to approximately CAN$5586.33 with average length of stay equal to over 2 months (64.22 days). One may assume that length of stay would be influenced by the amount of service and support available. Future research might investigate whether in-home palliative home care is the most cost effective and suitable care setting for those patients requiring home care services for expected periods of time. © 2009 SAGE Publications.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A novel Networks-on-Chip (NoC) router architecture specified for FPGA based implementation with configurable Virtual-Channel (VC) is presented. Each pipeline stage of the proposed architecture has been optimized so that low packet propagation latency and reduced hardware overhead can be achieved. The proposed architecture enables high performance and cost effective VC NoC based on-chip system interconnects to be deployed on FPGA.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

PURPOSE. To determine whether internal limiting membrane (ILM) peeling is effective and cost effective compared with no peeling in patients with idiopathic stage 2 or 3 full-thickness maculay hole (FTMH). METHODS. This was a pragmatic multicenter randomized controlled trial. Eligible participants from nine centers were randomized to ILM peeling or no peeling (1:1 ratio) in addition to phacovitrectomy, including detachment and removal of the posterior hyaloid and gas tamponade. The primary outcome was distance visual acuity (VA) at 6 months after surgery. Secondary outcomes included hole closure, distance VA at other time points, near VA, contrast sensitivity, reading speed, reoperations, complications, resource use, and participant-reported health status, visual function, and costs. RESULTS. Of 141 participants randomized in nine centers, 127 (90%) completed the 6-month follow-up. Nonstatistically significant differences in distance visual acuity at 6 months were found between groups (mean difference, 4.8; 95% confidence interval [CI], -0.3 to 9.8; P = 0.063). There was a significantly higher rate of hole closure in the ILM-peel group (56 [84%] vs. 31 [48%]) at 1 month (odds ratio [OR], 6.23; 95% CI, 2.64-14.73; P <0.001) with fewer reoperations (8 [12%] vs. 31 [48%]) performed by 6 months (OR, 0.14; 95% CI, 0.05- 0.34; P <0.001). Peeling the ILM is likely to be cost effective. CONCLUSIONS. There was no evidence of a difference in distance VA after the ILM peeling and no-ILM peeling techniques. An important benefit in favor of no ILM peeling was ruled out. Given the higher anatomic closure and lower reoperation rates in the ILM-peel group, ILM peeling seems to be the treatment of choice for idiopathic stage 2 to 3 FTMH. © 2011 The Association for Research in Vision and Ophthalmology, Inc.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Providing adequate supportive services for the families of palliative care patients is a core principle of palliative care. Caring for a patient with terminal illness at home involves a considerable commitment on the part of family caregivers, and attention must be given to the caregiver's needs as well as those of the patient. Although a home death may be preferred by patients and promoted by healthcare agencies as a cost-effective option, it may be an ideal that is not often realised. Enhanced supportive care strategies can ameliorate the challenges facing families of palliative care patients cared for at home. All health professionals need to improve the standard of family-centred palliative care, and more evidence-based approaches are required.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A novel cost-effective and low-latency wormhole router for packet-switched NoC designs, tailored for FPGA, is presented. This has been designed to be scalable at system level to fully exploit the characteristics and constraints of FPGA based systems, rather than custom ASIC technology. A key feature is that it achieves a low packet propagation latency of only two cycles per hop including both router pipeline delay and link traversal delay - a significant enhancement over existing FPGA designs - whilst being very competitive in terms of performance and hardware complexity. It can also be configured in various network topologies including 1-D, 2-D, and 3-D. Detailed design-space exploration has been carried for a range of scaling parameters, with the results of various design trade-offs being presented and discussed. By taking advantage of abundant buildin reconfigurable logic and routing resources, we have been able to create a new scalable on-chip FPGA based router that exhibits high dimensionality and connectivity. The architecture proposed can be easily migrated across many FPGA families to provide flexible, robust and cost-effective NoC solutions suitable for the implementation of high-performance FPGA computing systems. © 2011 IEEE.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Early-onset child conduct problems are common and costly. A large number of studies and some previous reviews have focused on behavioural and cognitive-behavioural group-based parenting interventions, but methodological limitations are commonplace and evidence for the effectiveness and cost-effectiveness of these programmes has been unclear. To assess the effectiveness and cost-effectiveness of behavioural and cognitive-behavioural group-based parenting programmes for improving child conduct problems, parental mental health and parenting skills. We searched the following databases between 23 and 31 January 2011: CENTRAL (2011, Issue 1), MEDLINE (1950 to current), EMBASE (1980 to current), CINAHL (1982 to current), PsycINFO (1872 to current), Social Science Citation Index (1956 to current), ASSIA (1987 to current), ERIC (1966 to current), Sociological Abstracts (1963 to current), Academic Search Premier (1970 to current), Econlit (1969 to current), PEDE (1980 to current), Dissertations and Theses Abstracts (1980 to present), NHS EED (searched 31 January 2011), HEED (searched 31 January 2011), DARE (searched 31 January 2011), HTA (searched 31 January 2011), mRCT (searched 29 January 2011). We searched the following parent training websites on 31 January 2011: Triple P Library, Incredible Years Library and Parent Management Training. We also searched the reference lists of studies and reviews. We included studies if: (1) they involved randomised controlled trials (RCTs) or quasi-randomised controlled trials of behavioural and cognitive-behavioural group-based parenting interventions for parents of children aged 3 to 12 years with conduct problems, and (2) incorporated an intervention group versus a waiting list, no treatment or standard treatment control group. We only included studies that used at least one standardised instrument to measure child conduct problems. Two authors independently assessed the risk of bias in the trials and the methodological quality of health economic studies. Two authors also independently extracted data. We contacted study authors for additional information. This review includes 13 trials (10 RCTs and three quasi-randomised trials), as well as two economic evaluations based on two of the trials. Overall, there were 1078 participants (646 in the intervention group; 432 in the control group). The results indicate that parent training produced a statistically significant reduction in child conduct problems, whether assessed by parents (standardised mean difference (SMD) -0.53; 95% confidence interval (CI) -0.72 to -0.34) or independently assessed (SMD -0.44; 95% CI -0.77 to -0.11). The intervention led to statistically significant improvements in parental mental health (SMD -0.36; 95% CI -0.52 to -0.20) and positive parenting skills, based on both parent reports (SMD -0.53; 95% CI -0.90 to -0.16) and independent reports (SMD -0.47; 95% CI -0.65 to -0.29). Parent training also produced a statistically significant reduction in negative or harsh parenting practices according to both parent reports (SMD -0.77; 95% CI -0.96 to -0.59) and independent assessments (SMD -0.42; 95% CI -0.67 to -0.16). Moreover, the intervention demonstrated evidence of cost-effectiveness. When compared to a waiting list control group, there was a cost of approximately $2500 (GBP 1712; EUR 2217) per family to bring the average child with clinical levels of conduct problems into the non-clinical range. These costs of programme delivery are modest when compared with the long-term health, social, educational and legal costs associated with childhood conduct problems. Behavioural and cognitive-behavioural group-based parenting interventions are effective and cost-effective for improving child conduct problems, parental mental health and parenting skills in the short term. The cost of programme delivery was modest when compared with the long-term health, social, educational and legal costs associated with childhood conduct problems. Further research is needed on the long-term assessment of outcomes.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Small off-road engines (SORE) have been recognised as a major source of air pollution. It is estimated that non handheld SORE annually produce over 1 million tonnes of HC+NOx and over 50 million tonnes of CO2. The fuel system design and its operating AFR are of key importance with regard to engine operation and engine out emissions. The conventional low-cost float carburettors used in these engines are relatively ineffective at atomising and preparing the fuel for combustion requiring a rich setting for acceptable functional performance. EPA and CARB have confirmed that Phase 3 limits are achievable for a “durable” engine fitted with a conventional well calibrated and manufactured “stock rich setting” float carburettor together with catalytic oxidation after-treatment and passive secondary air injection. The EPA and CARB strategy for meeting Phase 3 only considers the use of conventional float carburettors that operate at rich AFR’s over their entire engine operating range as no other cost effective alternative fuel system is yet available on the market. A cost effective alternative to the conventional carburettor that enabled leaner or optimised AFR operation with load and improved combustion performance would open the door to alternative strategies to meeting the phase 3 limits. This paper presents a completely new form of mechanical carburettor that gives AFR control with load, improved mixture preparation for improved combustion performance and has a lower production cost than conventional carburettors. The conventional and new fuel system designs and operation are discussed in detail and their technical merits demonstrated in the form of engine test data. The performance of different after-treatment systems is also simulated for different AFR profiles with load for a conventional or unmodified SORE engine. With optimised leaner operation and improved combustion characteristics, this new carburettor technology can provide significant engine out CO and HC+NOx reductions on the J1088 test cycle without loss of functional performance. Depending on the chosen emissions control strategy, minimum engine out emissions or optimum engine AFR for oxidation or three-way after-treatment or another, this new carburettor technology can be easily calibrated to provide the desired engine operating AFR profile on the J1088 cycle.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A mechanism of dual enlargement of gold nanoparticles (AuNPs) comprising two steps is described. In the first step, the AuNPs are enlarged by depositing Au atoms on their crystalline faces. In this process, the particles are not only enlarged but they are also observed to multiply: new Au nuclei are formed by the budding and division of the enlarged particles. In the second step, a silver enhancement is subsequently performed by the deposition of silver atoms on the enlarged and newly formed AuNPs to generate bimetallic Au@Ag core-shell structures. The dual nanocatalysis greatly enhances the electron density of the nanostructures, leading to a stronger intensity for colorimetric discrimination as well as better sensitivity for quantitative measurement. Based on this, a simple scanometric assay for the on-slide detection of the food-born pathogen Campylobacter jejuni is developed. After capturing the target bacteria, gold-tagged immunoprobes are added to create a signal on a solid substrate. The signal is then amplified by the dual enlargement process, resulting in a strong color intensity that can easily be recognized by the unaided eye, or measured by an inexpensive flatbed scanner. In this paper, dual nanocatalysis is reported for the first time. It provides a valuable mechanistic insight into the development of a simple and cost-effective detection format.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Reagent pre-storage in a microfluidic chip can enhance operator convenience, simplify the system design, reduce the cost of storage and shipment, and avoid the risk of cross-contamination. Although dry reagents have long been used in lateral flow immunoassays, they have rarely been used for nucleic acid-based point-of-care (POC) assays due to the lack of reliable techniques to dehydrate and store fragile molecules involved in the reaction. In this study, we describe a simple and efficient method for prolonged on-chip storage of PCR reagents. The method is based on gelification of all reagents required for PCR as a ready-to-use product. The approach was successfully implemented in a lab-on-a-foil system, and the gelification process was automated for mass production. Integration of reagents on-chip by gelification greatly facilitated the development of easy-to-use lab-on-a-chip (LOC) devices for fast and cost-effective POC analysis.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In this study, we describe a simple and efficient method for on-chip storage of reagents for point-of-care (POC) diagnostics. The method is based on gelification of all reagents required for on-chip PCR-based diagnostics as a ready-to-use product. The result reported here is a key step towards the development of a ready and easy to use fully integrated Lab-on-a-chip (LOC) system for fast, cost-effective and efficient POC diagnostics analysis.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The hybrid test method is a relatively recently developed dynamic testing technique that uses numerical modelling combined with simultaneous physical testing. The concept of substructuring allows the critical or highly nonlinear part of the structure that is difficult to numerically model with accuracy to be physically tested whilst the remainder of the structure, that has a more predictable response, is numerically modelled. In this paper, a substructured soft-real time hybrid test is evaluated as an accurate means of performing seismic tests of complex structures. The structure analysed is a three-storey, two-by-one bay concentrically braced frame (CBF) steel structure subjected to seismic excitation. A ground storey braced frame substructure whose response is critical to the overall response of the structure is tested, whilst the remainder of the structure is numerically modelled. OpenSees is used for numerical modelling and OpenFresco is used for the communication between the test equipment and numerical model. A novel approach using OpenFresco to define the complex numerical substructure of an X-braced frame within a hybrid test is also presented. The results of the hybrid tests are compared to purely numerical models using OpenSees and a simulated test using a combination of OpenSees and OpenFresco. The comparative results indicate that the test method provides an accurate and cost effective procedure for performing
full scale seismic tests of complex structural systems.