992 resultados para Cost-Informed


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents an integrated design and costing method for large stiffened panels for the purpose of investigating the influence and interaction of lay-up technology and production rate on manufacturing cost. A series of wing cover panels (≈586kg, 19·9m2) have been sized with realistic requirements considering manual and automated lay-up routes. The integrated method has enabled the quantification of component unit cost sensitivity to changes in annual production rate and employed equipment maximum deposition rate. Moreover the results demonstrate the interconnected relationship between lay-up process and panel design, and unit cost. The optimum unit cost solution when using automated lay-up is a combination of the minimum deposition rate and minimum number of lay-up machines to meet the required production rate. However, the location of the optimum unit cost, at the boundaries between the number of lay-up machines required, can make unit cost very sensitive to small changes in component design, production rate, and equipment maximum deposition rate. - See more at: http://aerosociety.com/News/Publications/Aero-Journal/Online/1941/Modelling-layup-automation-and-production-rate-interaction-on-the-cost-of-large-stiffened-panel-components#sthash.0fLuu9iG.dpuf

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The exponential growth in user and application data entails new means for providing fault tolerance and protection against data loss. High Performance Com- puting (HPC) storage systems, which are at the forefront of handling the data del- uge, typically employ hardware RAID at the backend. However, such solutions are costly, do not ensure end-to-end data integrity, and can become a bottleneck during data reconstruction. In this paper, we design an innovative solution to achieve a flex- ible, fault-tolerant, and high-performance RAID-6 solution for a parallel file system (PFS). Our system utilizes low-cost, strategically placed GPUs — both on the client and server sides — to accelerate parity computation. In contrast to hardware-based approaches, we provide full control over the size, length and location of a RAID array on a per file basis, end-to-end data integrity checking, and parallelization of RAID array reconstruction. We have deployed our system in conjunction with the widely-used Lustre PFS, and show that our approach is feasible and imposes ac- ceptable overhead.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Polymer extrusion is regarded as an energy-intensive production process, and the real-time monitoring of both energy consumption and melt quality has become necessary to meet new carbon regulations and survive in the highly competitive plastics market. The use of a power meter is a simple and easy way to monitor energy, but the cost can sometimes be high. On the other hand, viscosity is regarded as one of the key indicators of melt quality in the polymer extrusion process. Unfortunately, viscosity cannot be measured directly using current sensory technology. The employment of on-line, in-line or off-line rheometers is sometimes useful, but these instruments either involve signal delay or cause flow restrictions to the extrusion process, which is obviously not suitable for real-time monitoring and control in practice. In this paper, simple and accurate real-time energy monitoring methods are developed. This is achieved by looking inside the controller, and using control variables to calculate the power consumption. For viscosity monitoring, a ‘soft-sensor’ approach based on an RBF neural network model is developed. The model is obtained through a two-stage selection and differential evolution, enabling compact and accurate solutions for viscosity monitoring. The proposed monitoring methods were tested and validated on a Killion KTS-100 extruder, and the experimental results show high accuracy compared with traditional monitoring approaches.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Successful periodontal treatment requires a commitment to regular lifelong maintenance and may be perceived by patients to be costly. This study calculates the total lifetime cost of periodontal treatment in the setting of a specialist periodontal practice and investigates the cost implications of choosing not to proceed with such treatment. Methods: Data from patients treated in a specialist practice in Norway were used to calculate the total lifetime cost of periodontal treatment that included baseline periodontal treatment, regular maintenance, retreatment, and replacing teeth lost during maintenance. Incremental costs for alternative strategies based on opting to forego periodontal treatment or maintenance and to replace any teeth lost with either bridgework or implants were calculated. Results: Patients who completed baseline periodontal treatment but did not have any additional maintenance or retreatment could replace only three teeth with bridgework or two teeth with implants before the cost of replacing additional teeth would exceed the cost of lifetime periodontal treatment. Patients who did not have any periodontal treatment could replace ≤4 teeth with bridgework or implants before a replacement strategy became more expensive. Conclusions: Within the limits of the assumptions made, periodontal treatment in a Norwegian specialist periodontal practice is cost-effective when compared to an approach that relies on opting to replace teeth lost as a result of progressive periodontitis with fixed restorations. In particular, patients who have initial comprehensive periodontal treatment but do not subsequently comply with maintenance could, on average, replace ≤3 teeth with bridgework or two teeth with implants before this approach would exceed the direct cost of lifetime periodontal treatment in the setting of the specialist practice studied. © 2012 American Academy of Periodontology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: A previously described economic model was based on average values for patients diagnosed with chronic periodontitis (CP). However, tooth loss varies among treated patients and factors for tooth loss include CP severity and risk. The model was refined to incorporate CP severity and risk to determine the cost of treating a specific level of CP severity and risk that is associated with the benefit of tooth preservation.

Methods: A population that received and another that did not receive periodontal treatment were used to determine treatment costs and tooth loss. The number of teeth preserved was the difference of the number of teeth lost between the two populations. The cost of periodontal treatment was divided by the number of teeth preserved for combinations of CP severity and risk.

Results: The cost of periodontal treatment divided by the number of teeth preserved ranged from (US) $ 1,405 to $ 4,895 for high or moderate risk combined with any severity of CP and was more than $ 8,639 for low risk combined with mild CP. The cost of a three-unit bridge was $ 3,416, and the cost of a single-tooth replacement was $ 4,787.

Conclusion: Periodontal treatment could be justified on the sole basis of tooth preservation when CP risk is moderate or high regardless of disease severity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study presents a new method for determining the transmission network usage by loads and generators, which can then be used for transmission cost/loss allocation in an explainable and justifiable manner. The proposed method is based on solid physical grounds and circuit theory. It relies on dividing the currents through the network into two components; the first one is attributed to power flows from generators to loads, whereas the second one is because of the generators only. Unlike almost all the available methods, the proposed method is assumption free and hence it is more accurate than similar methods even those having some physical basis. The proposed method is validated through a transformer analogy, and theoretical derivations. The method is verified through application to the IEEE 30 bus system and the IEEE 118 test system. The results obtained verified many desirable features of the proposed method. Being more accurate in determining the network usage, in an explainable transparent manner, and in giving accurate cost signals, indicating the best locations to add loads and generation, are among the many desirable features.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper evaluates the potential of gabions as roadside safety barriers. Gabions have the capacity to blend into natural landscape, suggesting that they could be used as a safety barrier for low-volume road in scenic environments. In fact, gabions have already been used for this purpose in Nepal, but the impact response was not evaluated. This paper reports on numerical and experimental investigations performed on a new gabion barrier prototype. To assess the potential use as a roadside barrier, the optimal gabion unit size and mass were investigated using multibody analysis and four sets of 1:4 scaled crash tests were carried out to study the local vehicle-barrier interaction. The barrier prototype was then finalised and subjected to a TB31 crash test according to the European EN1317 standard for N1 safety barriers. The test resulted in a failure due to the rollover of the vehicle and tearing of the gabion mesh yielding a large working width. It was found that although the system potentially has the necessary mass to contain a vehicle, the barrier front face does not have the necessary stiffness and strength to contain the gabion stone filling and hence redirect the vehicle. In the EN1317 test, the gabion barrier acted as a ramp for the impacting vehicle, causing rollover. 

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction Asthma is now one of the most common long-term conditions in the UK. It is therefore important to develop a comprehensive appreciation of the healthcare and societal costs in order to inform decisions on care provision and planning. We plan to build on our earlier estimates of national prevalence and costs from asthma by filling the data gaps previously identified in relation to healthcare and broadening the field of enquiry to include societal costs. This work will provide the first UK-wide estimates of the costs of asthma. In the context of asthma for the UK and its member countries (ie, England, Northern Ireland, Scotland and Wales), we seek to: (1) produce a detailed overview of estimates of incidence, prevalence and healthcare utilisation; (2) estimate health and societal costs; (3) identify any remaining information gaps and explore the feasibility of filling these and (4) provide insights into future research that has the potential to inform changes in policy leading to the provision of more cost-effective care.

Methods and analysis Secondary analyses of data from national health surveys, primary care, prescribing, emergency care, hospital, mortality and administrative data sources will be undertaken to estimate prevalence, healthcare utilisation and outcomes from asthma. Data linkages and economic modelling will be undertaken in an attempt to populate data gaps and estimate costs. Separate prevalence and cost estimates will be calculated for each of the UK-member countries and these will then be aggregated to generate UK-wide estimates.

Ethics and dissemination Approvals have been obtained from the NHS Scotland Information Services Division's Privacy Advisory Committee, the Secure Anonymised Information Linkage Collaboration Review System, the NHS South-East Scotland Research Ethics Service and The University of Edinburgh's Centre for Population Health Sciences Research Ethics Committee. We will produce a report for Asthma-UK, submit papers to peer-reviewed journals and construct an interactive map.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Robust, bilayer heterojunction photodiodes of TiO2-WO3 were prepared successfully by a simple, low-cost powder pressing technique followed by heat-treatment. Exclusive photoirradiation of the TiO2 side of the photodiode resulted in a rapid colour change (dark blue) on the WO3 surface as a result of reduction of W6+ to W5+ (confirmed by X-ray photoelectron spectroscopy). This colour was long lived and shown to be stable in a dry environment in air for several hours. A similar photoirradiation experiment in the presence of a mask showed that charge transfer across the heterojunction occurred approximately normal to the TiO2 surface, with little smearing out of the mask image. As a result of the highly efficient vectorial charge separation, the photodiodes showed a tremendous increase in photocatalytic activity for the degradation of stearic acid, compared to wafers of the respective individual materials when tested separately.