889 resultados para Ácido kaínico


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Bone is constantly being molded and shaped by the action of osteoclasts and osteoblasts. A proper equilibrium between both cell types metabolic activities is required to ensure an adequate skeletal tissue structure, and it involves resorption of old bone and formation of new bone tissue. It is reported that treatment with antiepileptic drugs (AEDs) can elicit alterations in skeletal structure, in particular in bone mineral density. Nevertheless, the knowledge regarding the effects of AEDs on bone cells are still scarce. In this context, the aim of this study was to investigate the effects of five different AEDs on human osteoclastic, osteoblastic and co-cultured cells. Osteoclastic cell cultures were established from precursor cells isolated from human peripheral blood and were characterized for tartrate-resistant acid phosphatase (TRAP) activity, number of TRAP+ multinucleated cells, presence of cells with actin rings and expressing vitronectin and calcitonin receptors and apoptosis rate. Also, the involvement of several signaling pathways on the cellular response was addressed. Osteoblastic cell cultures were obtained from femur heads of patients (25-45 years old) undergoing orthopaedic surgery procedures and were then studied for cellular proliferation/viability, ALP activity, histochemical staining of ALP and apoptosis rate. Also the expression of osteoblast-related genes and the involvement of some osteoblastogenesis-related signalling pathways on cellular response were addressed. For co-cultured cells, osteoblastic cells were firstly seeded and cultured. After that, PBMC were added to the osteoblastic cells and co-cultures were evaluated using the same osteoclast and osteoblast parameters mentioned above for the corresponding isolated cell. Cell-cultures were maintained in the absence (control) or in the presence of different AEDs (carbamazepine, gabapentin, lamotrigine, topiramate and valproic acid). All the tested drugs were able to affect osteoclastic and osteoblastic cells development, although with different profiles on their osteoclastogenic and osteoblastogenic modulation properties. Globally, the tendency was to inhibit the process. Furthermore, the signaling pathways involved in the process also seemed to be differently affected by the AEDs, suggesting that the different drugs may affect osteoclastogenesis and/or osteoblastogenesis through different mechanisms. In conclusion, the present study showed that the different AEDs had the ability to directly and indirectly modulate bone cells differentiation, shedding new light towards a better understanding of how these drugs can affect bone tissue.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introdução – A estimativa da função renal relativa (FRR) através de cintigrafia renal (CR) com ácido dimercaptossuccínico marcado com tecnécio-99 metaestável (99mTc-DMSA) pode ser influenciada pela profundidade renal (PR), atendendo ao efeito de atenuação por parte dos tecidos moles que envolvem os rins. Dado que raramente é conhecida esta mesma PR, diferentes métodos de correção de atenuação (CA) foram desenvolvidos, nomeadamente os que utilizam fórmulas empíricas, como os de Raynaud, de Taylor ou de Tonnesen, ou recorrendo à aplicação direta da média geométrica (MG). Objetivos – Identificar a influência dos diferentes métodos de CA na quantificação da função renal relativa através da CR com 99mTc-DMSA e avaliar a respetiva variabilidade dos resultados de PR. Metodologia – Trinta e um pacientes com indicação para realização de CR com 99mTc-DMSA foram submetidos ao mesmo protocolo de aquisição. O processamento foi efetuado por dois operadores independentes, três vezes por exame, variando para o mesmo processamento o método de determinação da FRR: Raynaud, Taylor, Tonnesen, MG ou sem correção de atenuação (SCA). Aplicou-se o teste de Friedman para o estudo da influência dos diferentes métodos de CA e a correlação de Pearson para a associação e significância dos valores de PR com as variáveis idade, peso e altura. Resultados – Da aplicação do teste de Friedman verificaram-se diferenças estatisticamente significativas entre os vários métodos (p=0,000), excetuando as comparações SCA/Raynaud, Tonnesen/MG e Taylor/MG (p=1,000) para ambos os rins. A correlação de Pearson demonstra que a variável peso apresenta uma correlação forte positiva com todos os métodos de cálculo da PR. Conclusões – O método de Taylor, entre os três métodos de cálculo de PR, é o que apresenta valores de FRR mais próximos da MG. A escolha do método de CA influencia significativamente os parâmetros quantitativos de FRR.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Química e Biológica

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Resumo Uma estratégia de avaliação e prevenção de riscos na exposição a agentes químicos deve ter sempre em conta que a vigilância do ambiente de trabalho e a da saúde dos trabalhadores são aspectos complementares de uma mesma realidade – os riscos resultantes da interacção entre um agente químico e os trabalhadores a ele expostos. Se à Vigilância Ambiental compete apreciar o risco, pela caracterização do agente no ambiente de trabalho, a Vigilância Biológica pronuncia-se sobre a interacção entre o tóxico e o organismo, avaliando a resposta à agressão química e a evolução das reacções de adaptação ou de desajuste face à absorção do tóxico. Os Indicadores Biológicos, deste modo, assumem um estatuto de instrumento privilegiado na vigilância da saúde dos trabalhadores expostos, na medida em que medem a quantidade de tóxico que efectivamente penetrou e foi absorvido, ou o resultado (efeito) determinado por essa mesma dose. O presente estudo procura contribuir para a definição de um quadro metodológico de utilização dos Indicadores Biológicos na avaliação/gestão da exposição profissional ao chumbo, designadamente apreciando a variação da protoporfirina-zinco (PPZ), indicador até ao presente ainda não utilizado em Portugal. O chumbo é um metal de ocorrência natural, cujos níveis nos diversos ecossistemas resultam, principalmente, das actividades antropogénicas de natureza doméstica e industrial. A sua capacidade poluente é assinalável, representando uma fonte de exposição permanente para o homem, demonstrável pela sua constante presença no organismo apesar de não desempenhar qualquer tipo de função fisiológica. São actualmente inúmeras as suas aplicações, tornando a exposição profissional ao chumbo uma realidade vasta: indústrias de acumuladores eléctricos, de vidros, de plásticos e de munições, construção civil, manutenção e reparação automóvel e de navios, fabrico de tintas, indústrias electrónicas, fundições e actividades de soldadura são, entre outras, situações onde é uma realidade a ter em conta. A penetração dos compostos inorgânicos de chumbo no organismo efectua-se principalmente por via respiratória, não sendo, no entanto, desprezável, a sua penetração por via digestiva. As partículas absorvidas são transportadas pelo sangue principalmente ligadas aos eritrocitos (95%), distribuem-se pelos tecidos moles e depositam-se essencialmente no tecido ósseo, onde representam mais de 90% da carga corporal do total absorvido e tendo aí um elevado tempo de semi-vida (mais de 20 anos). Não é metabolizado no organismo e a sua eliminação efectua-se essencialmente por via renal,sendo igualmente excretado, em menor escala, através das fezes, do suor, da saliva, das faneras e do leite materno. O conhecimento científico evidencia que concentrações sanguíneas de chumbo entre 20 e 50 mg/dL são susceptíveis de determinar efeitos adversos no homem, podendo ser afectados o sistema hematopoiético, o sistema nervoso, o sistema cardiovascular, o sistema reprodutor e o sistema imunitário. Contudo, ainda muito há a clarificar no âmbito da toxicidade do chumbo. Os níveis de exposição a que correspondem as alterações nos diversos órgãos e sistemas continuam a ser motivo de alguma controvérsia. As características carcinogénicas e mutagénicas do chumbo são, ainda, um campo de vasta exigência de investigação. A intoxicação por chumbo e seus sais (Saturnismo) de origem ocupacional é reconhecida em Portugal como doença profissional (grupo 1 - Doenças Provocadas por Agentes Químicos, da Lista das Doenças Profissionais). É uma intoxicação do tipo crónico, fruto da absorção contínua de doses relativamente pequenas durante longo período, evidenciando-se no seu início por sinais e sintomas vagos e difusos de grande inespecificidade, que podem incluir, nomeadamente, perda de apetite, sabor metálico na boca, palidez, mal-estar e fadiga, cefaleias, mialgias e artralgias, irritabilidade, tremores finos, obstipação, cólicas abdominais, insónias, déficit da memória de curto prazo e da capacidade de concentração. Um importante conjunto de indicadores biológicos pode ser utilizado na vigilância periódica da saúde de trabalhadores nestas condições de exposição. Tais indicadores (de dose ou de efeito), encerram diferentes significados e comportam distintas exigências, competindo ao Médico do Trabalho, no âmbito dos programas de prevenção dos efeitos adversos relacionados com a exposição profissional a chumbo, seleccionar a sua utilização e interpretar a sua informação, de modo a avaliar a interacção do tóxico com o organismo numa fase de reversibilidade. O presente estudo envolveu 180 trabalhadores dos quais 110 apresentavam plumbémias (Pb-S) iguais ou superiores a 40 mg/dL. Além da Pb-S, a todos foi doseada a protoporfirina-zinco (PPZ) e efectuado o Hemograma e a cerca de 25% foi determinada a concentração do ácido d-aminolevulínico urinário (ALA-U). Os doseamentos da PPZ efectuados em amostra de sangue capilar através de um hematofluorímetro portátil revelaram-se de total fiabilidade, dando significado a uma técnica de fácil execução e baixo custo. A avaliação do tipo de colheita urinária para doseamento do ALA-U concluiu pela necessidade de recurso a urinas de 24 horas.Os resultados do estudo evidenciaram uma elevada associação entre a PPZ e a Pb-S, com uma maior magnitude e de início mais precoce do que o que registado na associação da Pb-S com o ALA-U. Revelaram, ainda, fracos níveis de associação da hemoglobina (e outros parâmetros hematológicos) com a Pb-S. E demonstraram para um cut-off de 100 mg/ dL de PPZ, taxa de falsos negativos e falsos positivos, para plumbémias a partir de 70 mg/dL, inferiores a 20%. Assim, concluiu-se que, nos protocolos de vigilância de saúde de trabalhadores expostos a chumbo, o doseamento da PPZ por hematofluorímetro, em sangue de colheita capilar, é adequado, fiável e de realização preferencial em relação ao do ALA-U. Concluiu-se, também, que a realização do hemograma apenas se justifica em situações individuais que clinicamente o tornem aconselhável. E que estes protocolos devem incluir a realização da Pb-S e da PPZ, podendo, em situações de controlo rigoroso (ambiental, biológico e clínico), basear-se apenas na determinação da PPZ reservando os outros indicadores para aprofundar a investigação médica nos casos de taxas elevadas desta ou de situações limitantes. ■ Résumée Une stratégie d’évaluation et de prévention des risques d’exposition aux agents chimiques doit toujours tenir en considération que la vigilance du lieu de travail et de la santé des travailleurs sont des aspects complémentaires d’une même réalité – les risques résultant d’une interaction entre l’agent chimique et les travailleurs exposés. Si c’est à la Vigilance Ambiantale de juger le risque, par la caractérisation de l’agent dans le lieu de travail, la Vigilance Biologique, elle, se prononce sur l’interaction entre le toxique et l’organisme, évaluant la réponse à l’agression chimique et l’évolution des réactions d’adaptation ou de rupture face à l’absorption du toxique. Les Indicateurs Biologiques assument ainsi un statut d’instrument privilégié de vigilance de la santé des travailleurs exposés, dans la mesure où ils déterminent la quantité de toxique qui a effectivement été pénétré et absorbé, ou le résultat (effet) déterminé par cette dose. Cette étude-ci cherche à contribuer à la définition d’un cadre méthodologique d’utilisation des Indicateurs Biologiques dans l’évaluation/ gestion de l’exposition professionnelle au plomb inorganique, évaluant spécialement le comportement de la protoporphirine-zinc (PPZ), indicateur pas encore utilisé au Portugal.Le plomb est un métal d’occurrence naturelle dont les niveaux dans les différents écosystèmes en résultent, principalement, des activités anthropogéniques de nature domestique et industrielle. Sa capacité polluante peut être signalée, représentant une source d’exposition permanente pour l’homme, celle-ci démontrable par sa présence continue dans l’organisme, même si elle n’y accomplit aucune fonction physiologique. Actuellement ses applications sont innombrables, faisant de l’exposition professionnelle au plomb une réalité de grande ampleur : industries d’accumulateurs électriques, de verre, de plastique et de munitions, bâtiments, manutention et réparation automobile et navale, fabrication d’encres, industries électroniques, fontes et activités de soudure sont, entre autres, des situations réelles a en tenir compte. La pénétration du plomb inorganique dans l’organisme se fait principalement par voie respiratoire, pouvant se faire également par voie digestive. Les particules absorbées sont transportées par le sang, surtout liées aux érythrocytes (95%), se repartent à travers les tissus mous et se déposent essentiellement dans le tissu osseux, où elles représentent plus de 90% de la charge corporelle de ce qui a été absorbé et ont un temps de demi-vie élevé (plus de 20 ans). Le plomb n’est pas métabolisé dans l’organisme et son élimination se fait essentiellement par voie rénale, pouvant tout de même, à une moindre échelle, être excrété dans les fèces, de la sueur, de la salive, des ongles, des cheveux et du lait maternel. La connaissance scientifique met en évidence que des concentrations sanguines de plomb entre 20 et 50 mg/dL sont susceptibles de déterminer des effets adverses dans l’homme, pouvant les systèmes hématopoïétique, nerveux, cardiovasculaire, reproducteur et immunitaire en être affectés. Cependant, il en reste beaucoup à éclaircir dans le domaine de la toxicité du plomb. Les niveaux d’exposition auxquels correspondent les modifications des divers organes et systèmes, demeurent toujours sujet de quelque controverse. Les caractéristiques carcinogèniques et mutagèniques du plomb restent toujours un champ d’investigation d’une grande exigence. L’intoxication par le plomb et ses sels (Saturnisme) d’origine occupationnelle est reconnue, au Portugal, comme une maladie professionnelle (groupe 1- Maladies Provoquées par des Agents Chimiques, de la Liste des Maladies Professionnelles). C’est une intoxication du tipe chronique, due à l’absorption continue de doses relativement petites pendant une longue période, mise en évidence à travers des signes et des symptômes vagues et diffus sans grande spécificité, lesquels peuvent inclure, particulièrement, le manque d’appétit, goût métallique dans la bouche, pâleur, malaise et fatigue, céphalées, myalgies et arthralgies, irritabilité, tremblements fins, constipation, coliques abdominales, insomnies, déficit de la mémoire à court terme et de la capacité de concentration.Un ensemble important d’indicateurs biologiques peut être employé dans la vigilance périodique de la santé des travailleurs dans ces conditions d’exposition. Ces indicateurs (de dose ou d’effet) renferment différentes significations et comportent diverses exigences, devant le Médecin de Travail, dans le domaine des programmes de prévention des effets adverses qui sont en relation avec l’exposition professionnelle au plomb, sélectionner son utilisation et interpréter son information de façon à évaluer l’interaction de l’élément toxique avec l’organisme à un stade de réversibilité. L’étude ci-présent engloba 180 travailleurs desquels 110 présentaient des plombémies (Pb-S) égales ou supérieures à 40 mg/dL. À part la Pb-S, la protoporphyrine-zinc (PPZ) leur a été prise en dosage et un Hémogramme fut effectué et fut déterminé l’acide d- aminolévulinique urinaire (ALA-U) sur environ 25% des travailleurs. Le dosage de la PPZ efectué en échantillon de sang capillaire par un fluorimètre portable, s’est accomplit d’une fiabilité total, donnant du sgnificat à une téchnique de facile execution et bas prix. L’évaluation de la prise urinaire par dosage du ALA-U conclut au besoin d’un recours aux urines de 24 heures Les résultats de l’étude ont mis en évidence une association élevée entre la PPZ et la Pb- S, avec une intensité majeure et de début plus précoce par rapport à celui qui fut registré lors de l’association de la Pb-S avec la ALA-U. Ces résultats ont également montré de faibles niveaux d’association entre l’hémoglobine (et autres paramètres hématologiques) et la Pb-S. Ils ont démontré aussi, une valeur de cut-off de 100 mg/dL de PPZ, des taux de faux négatifs et faux positifs, pour des plombémies de 70 mg/dL, inférieurs à 20%. On peut donc conclure que dans les protocoles de vigilance de la santé des travailleurs exposés au plomb, le dosage de la PPZ par fluorimetrie dans le sang capillaire est adéquat, fiable et de réalisation préférentielle par rapport à celui du ALA-U. On peut également conclure que la réalisation de l’hémogramme ne se justifie que dans les cas individuels où, cliniquement, celui-ci est conseillé. De plus, ces protocoles doivent inclure la réalisation de la Pb-S et de la PPZ, pouvant, en cas de contrôle rigoureux (ambiantal, biologique et clinique), s’appuyer que dans la détermination de la PPZ réservant les autres indicateurs pour approfondir l’investigation médicale dans les cas où les taux de celle-ci sont élevés ou dans les cas de situations limitantes. ■ Summary Any strategy to evaluate and prevent the risks of chemical agents exposure must always regard the work environment and workers health as complementary aspects of one reality - the resulting risks from the interaction between the chemical agent and the exposed workers. It is the responsibility of Environmental Monitoring to evaluate the risks of exposure by the characterization of the chemical agent in the work environment. Biological Monitoring, on the other hand, pronounces itself over the toxin and body interaction, evaluating human response to the chemical aggression and the body adaptations to the toxic absorption. Biological Exposure Indices (BEI) assume, therefore, a privileged status among exposed workers' health monitoring instruments, as they measure the actual penetrated and absorbed toxic quantity and the effect it produces. This research study aims to contribute to the definition of a methodological strategy on the utilization of BEI’s in evaluating inorganic lead's occupational exposure, more specifically appreciating the zinc protoporphyrin (ZPP) variation, an index that has never been taken under consideration in Portugal until now. Lead is a natural metal whose ecosystem’s levels are mainly due to domestic and industrial anthropogenic activities. Its pollutant capacity is notable, representing a permanent exposure risk shown by its constant presence in the human body, although it has no physiologic function. Nowadays, lead's applications are countless, turning its professional exposure a huge reality: storage batteries industries, glass industries, plasterers and munitions industries, building construction, ships and motor car maintenance and repairing, ink manufacture, electronics industries, foundries and other soldering activities are, among so many other, realities to attend to. Respiration is the main cause of human body's inorganic lead absorption, although digestive pathway must not to be ignored. The absorbed particles are transported by blood, essentially bounded to erythrocytes (95%). It is distributed by soft tissues and settled mainly on bone tissues, where it represents approximately 90% of the total body charge and has a high half-life time (more than 20 years). It is not metabolized by the organism, its elimination being effectuated by renal activity and, in smaller scale, through lees, sweat, saliva, nails, hair and maternal milk.Scientific knowledge shows that concentrations of lead in blood between 20 e 50 mg/dL are susceptible to determine adverse effects in man and able to affect the hematopoietic system, the nervous system, the cardiovascular system, the reproductive system and the immunological system. Nevertheless, there's still much to be learned and clarified about lead's toxicity. The correlation between exposure levels and human's systems and organs alteration levels continues to be a centre of controversies. Still, lead's carcinogenic and mutagenic characteristics continue to be a high demanding research field. Intoxication by lead and its compounds (saturnism), from occupational origin, is recognized in Portugal as an occupational disease, included in Group 1 - Chemical Agents Caused Diseases, on the Occupational Diseases List. It is a chronic intoxication caused by a continuous absorption of small doses, throughout a long period of time. Its signs and symptoms are diffuse and imprecise, of great unspecificity, such as loss of appetite, metallic flavor in the mouth, paleness, ailment and fatigue, headaches, myalgia and arthralgia, irritability, thin tremors, constipation, abdominal pain, insomnias, short memory loses and inability to concentrate. A considered number of BEI’s can be used in Periodic Health Monitoring of workers in such exposure conditions. Such BEI (dose indices or effect indices) provide different meanings and imply different procedures, being Occupational Doctors responsibility, in the context of lead related adverse effects preventive programmes, to select and interpret its information, in order to evaluate the interaction between toxic and organism in a reversible phase of the toxic action. The present research study involved 180 workers, 110 of which presented blood lead levels (PbB) above or equal to 40 mg/dL. Besides PbB, all workers has been evaluated for zinc protoporphyrin levels (PPZ) and submitted to a haemogram. About 25% of the workers were selected for d-aminolevulinic urinary acid (ALA-U) determination. The evaluation of PPZ, by a portable hematofluorometer using capillary blood samples, turned out to be an easy procedure with low costs and total warrantability. As in regard for ALA- U procedure, it was concluded the necessity of 24 hours urine samples. This research results underlined a strong connection between ZPP and PbB, which was found to to be stringer and to begin earlier than it was registered for PbB and ALA-U association. The same study also revealed a low association level between PbB and hemoglobin or other hematological indices. It was also verified less than 20% of false negatives and false positives cases when admitted a ZPP 100 mg/dL cut off value for PbB³ 70 mg/dL. As in result it was concluded that in Health Monit

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A citologia de impressão da superfície ocular é uma técnica pouco invasiva que permite a análise de células da conjuntiva e da córnea, sendo uma alternativa aos esfregaços e punções. Desta forma, é indispensável garantir uma fase analítica eficiente. Na revisão bibliográfica encontram-se diversos agentes fixadores para este tipo de material, não sendo explícito o método de fixação mais eficaz. A fixação visa preservar os constituintes celulares quimicamente e estruturalmente, numa situação idêntica ao in vivo, estado este que é fundamental para a realização da técnica e consequente obtenção de um diagnóstico final correto. Objetivo do estudo - O objetivo deste estudo foi identificar o melhor fixador para amostras de citologia de impressão ocular – SureThin, PreservCyt, etanol a 95% e uma mistura constituída por formaldeído a 37%, ácido acético glacial e etanol a 70% (FAA 70%).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Química e Biológica

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Química

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Trabalho Final de Mestrado para obtenção de grau de Mestre em Engenharia Química e Biológica

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Trabalho Final de mestrado para obtenção do grau de Mestre em Engenharia Química e Biológica

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O trabalho descrito compreende o desenvolvimento de um anticorpo plástico (MIP, do inglês Molecularly Imprinted Polymer) para o antigénio carcinoembrionário (CEA, do inglês Carcinoembriogenic Antigen) e a sua aplicação na construção de dispositivos portáteis, de tamanho reduzido e de baixo custo, tendo em vista a monitorização deste biomarcador do cancro do colo-retal em contexto Point-of-Care (POC). O anticorpo plástico foi obtido por tecnologia de impressão molecular orientada, baseada em eletropolimerização sobre uma superfície condutora de vidro recoberto por FTO. De uma forma geral, o processo foi iniciado pela electropolimerização de anilina sobre o vidro, seguindo-se a ligação por adsorção do biomarcador (CEA) ao filme de polianilina, com ou sem monómeros carregados positivamente (Cloreto de vinilbenziltrimetilamónio, VB). A última fase consistiu na electropolimerização de o-fenilenodiamina (oPD) sobre a superfície, seguindo-se a remoção da proteína por clivagem de ligações peptídicas, com o auxílio de tripsina. A eficiência da impressão do biomarcador CEA no material polimérico foi controlada pela preparação de um material análogo, NIP (do inglês, Non-Imprinted Polymer), no qual nem a proteína nem o monómero VB estavam presentes. Os materiais obtidos foram caracterizados quimicamente por técnicas de Infravermelho com Transformada de Fourier (FTIR, do inglês, Fourier Transform Infrared Spectroscopy) e microscopia confocal de Raman. Os materiais sensores preparados foram entretanto incluídos em membranas poliméricas de Poli(cloreto de vinilo) (PVC) plastificado, para construção de sensores (biomiméticos) seletivos a CEA, tendo-se avaliado a resposta analítica em diferentes meios. Obteve-se uma boa resposta potenciométrica em solução tampão de Ácido 4-(2-hidroxietil)piperazina-1-etanosulfónico (HEPES), a pH 4,4, com uma membrana seletiva baseada em MIP preparada com o monómero carregado VB. O limite de deteção foi menor do que 42 pg/mL, observando-se um comportamento linear (versus o logaritmo da concentração) até 625 pg/mL, com um declive aniónico igual a -61,9 mV/década e r2>0,9974. O comportamento analítico dos sensores biomiméticos foi ainda avaliado em urina, tendo em vista a sua aplicação na análise de CEA em urina. Neste caso, o limite de deteção foi menor do que 38 pg/mL, para uma resposta linear até 625 pg/mL, com um declive de -38,4 mV/década e r2> 0,991. De uma forma geral, a aplicação experimental dos sensores biomiméticos evidenciou respostas exatas, sugerindo que os biossensores desenvolvidos prossigam estudos adicionais tendo em vista a sua aplicação em amostras de indivíduos doentes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Este trabalho descreve o desenvolvimento de um material sensor para creatinina por impressão molecular em estrutura polimérica (MIP) e a sua aplicação no desenvolvimento de um dispositivo de natureza potenciométrica para a determinação da molécula alvo em fluidos biológicos. A creatinina é um dos biomarcadores mais utilizados no acompanhamento da doença renal, já que é um bom indicador da taxa de filtração glomerular (TFG). Os materiais biomiméticos desenhados para interação com a creatinina foram obtidos por polimerização radicalar, recorrendo a monómeros de ácido metacríclico ou de vinilpiridina e a um agente de reticulação apropriado. De modo a aferir o efeito da impressão da creatinina na resposta dos materiais MIP à sua presença, foram também preparados e avaliados materiais de controlo, obtidos sem impressão molecular (NIP). O controlo da constituição química destes materiais, incluindo a extração da molécula impressa, foi realizado por Espectroscopia de Raman e de Infravermelho com Transformada de Fourrier. A afinidade de ligação entre estes materiais e a creatinina foi também avaliada com base em estudos cinéticos. Todos os materiais descritos foram integrados em membranas selectivas de elétrodos seletivos de ião, preparadas sem ou com aditivo iónico lipófilo, de carga negativa ou positiva. A avaliação das características gerais de funcionamento destes elétrodos, em meios de composição e pH diferentes, indicaram que as membranas com materiais impressos e aditivo aniónico eram as únicas com utilidade analítica. Os melhores resultados foram obtidos em solução tampão Piperazine-N,N′-bis(2- ethanesulfonic acid), PIPES, de pH 2,8, condição que permitiu obter uma resposta quasi-Nernstiana, a partir de 1,6×10-5 mol L-1. Estes elétrodos demonstraram ainda uma boa selectividade ao apresentaram uma resposta preferencial para a creatinina quando na presença de ureia, carnitina, glucose, ácido ascórbico, albumina, cloreto de cálcio, cloreto de potássio, cloreto de sódio e sulfato de magnésio. Os elétrodos foram ainda aplicados com sucesso na análise de amostras sintéticas de urina, quando os materiais sensores eram baseados em ácido metacrilico, e soro, quando os materiais sensores utilizados eram baseados em vinilpiridina.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: Paediatric patients who undergo posterior spinal fusion surgery to correct scoliosis often require multiple blood transfusions. Tranexamic acid is a synthetic antifibrinolytic drug that reduces transfusion requirements in scoliosis surgery (1),(2),(3). Methods: To evaluate the efficacy of prophylactic tranexamic acid (TA) (initial dose of 10mg/kg and infusion of 1mg.kg(-1).h(-1)) in reducing perioperative blood transfusion requirements, we reviewed patients files and compared the amount of blood lost and blood transfused in the perioperative period of 12 patients (54.5%) that received TA and 10 patients (45.5%) who did not received TA. T-Student test was applied. Results: The average difference of blood losses (2,67 +/- 6,06ml) and blood transfused (212,9 +/- 101,1ml) between the two groups was not statistically significant (p>0.05). No thrombotic complications were detected in either group. Discussion: Results of the current study showed that prophylactic low dose of TA did not have a significant effect in the management of intraoperative blood loss and transfusion requirements in children undergoing scoliosis surgery. It is important to emphasize that our study is retrospective and that the size of the sample is small. Further studies are needed to evaluate the efficacy and safety of TA on paediatric scoliosis surgery.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O Cancro da mama é uma doença cuja incidência tem vindo a aumentar de ano para ano e além disso é responsável por um grande número de mortes em todo mundo. De modo a combater esta doença têm sido propostos e utilizados biomarcadores tumorais que permitem o diagnóstico precoce, o acompanhamento do tratamento e/ou a orientação do tipo tratamento a adotar. Atualmente, os biomarcadores circulantes no sangue periférico recomendados pela Associação Americana de Oncologia Clinica (ASCO) para monitorizar os pacientes durante o tratamento são o cancer antigen 15-3 (CA 15-3), o cancer antigen 27.29 (CA 27.29) e o cancer embryobic antigen (CEA). Neste trabalho foi desenvolvido um sensor eletroquímico (voltamétrico) para monitorizar o cancro da mama através da análise do biomarcador CA 15-3. Inicialmente realizou-se o estudo da adsorção da proteína na superfície do elétrodo para compreender o comportamento do sensor para diferentes concentrações. De seguida, estudaram-se três polímeros (poliaminofenol, polifenol e polifenilenodiamina) e selecionou-se o poliaminofenol como o polímero a utilizar, pois possuía a melhor percentagem de alteração de sinal. Após a seleção do polímero, este foi depositado na superfície do elétrodo por eletropolimerização, formando um filme polimérico molecularmente impresso (MIP) à volta da proteína (molde). Posteriormente, foram analisados cinco solventes (água, mistura de dodecil sulfato de sódio e ácido acético, ácido oxálico, guanidina e proteinase K) e o ácido oxálico revelou ser mais eficaz na extração da proteína. Por último, procedeu-se à caraterização do sensor e analisou-se a resposta analítica para diferentes concentrações de CA 15-3 revelando diferenças claras entre o NIP (polímero não impresso) e o MIP.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O presente trabalho tem como objetivo o cultivo da microalga Chlorella zofingiensis, e a avaliação da sua potencial aplicação na produção de biodiesel e de produtos de valor acrescentado, de entre os quais se destacam os antioxidantes. Com o intuito da produção de biocombustível é necessário efetuar o cultivo da microalga num volume que permita a obtenção de elevada quantidade de biomassa para a concretização do trabalho. Além deste biocombustível, existe ainda a possibilidade de valorização de alguns produtos com valor comercial, como é o caso da astaxantina, a saber na área farmacêutica, alimentar ou até mesmo cosmética. O cultivo da microalga foi feito em meio Bold’s Basal Medium (BBM), inicialmente em matrazes de 5 L e, quando se obteve uma cultura suficientemente densa, inocularam-se fotobiorreatores de 50 L. Conseguiu-se atingir uma concentração máxima de 0,76 g/L, no reator de 5 L, após cerca de 6 semanas de ensaio. Por sua vez, em fotobiorreatores de 50 L, a concentração máxima obtida foi de 0,4 g/L, após 4 semanas de ensaio. Nestas culturas foi possível obter-se uma percentagem lipídica de 7 %, apresentado concentração de pigmentos por litro de cultura na ordem dos 10 mg/L, 4 mg/L e 2 mg/L de clorofila a, clorofila b e carotenoides totais, respetivamente. Com esta percentagem lipídica recuperaram-se 400 mg de óleo, obtendo-se posteriormente 280 mg de biodiesel. Pela análise à amostra de biodiesel obtida foi possível obter o perfil lipídico desta microalga, quando cultivada em meio BBM, sendo 41% de ácido palmítico (C16:0), 9% de ácido esteárico (C18:0), 27% de ácido oleico (C18:1) e 23% de ácido linoleico (C18:2). Os resultados obtidos mostram que a Chlorella zofingiensis é uma microalga com interesse potencial para a produção de clorofila e carotenóides, mas não para o óleo para a produção de biodiesel.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Os ácidos gordos desempenham um papel fisiológico importante como componentes indispensáveis na estrutura celular, bem como fontes de energia. Nas últimas décadas, tem havido um aumento notável do interesse público nos ácidos gordos polinsaturados ómegas 3 e 6 e no seu impacto sobre a saúde humana, especialmente em doenças metabólicas e cardiovasculares. Estes ácidos gordos específicos podem prevenir e/ou tratar várias patologias metabólicas, atuando nomeadamente como compostos anti-inflamatórios. A menopausa é um fator de risco para doença cardiovascular, a diminuição de estrogénio, que ocorre neste estado fisiológico, provoca disfunção endotelial e stresse oxidativo. Consequentemente há uma redução dos níveis de ácidos gordos polinsaturados ómegas 3, o que contribui para o aparecimento de aterosclerose e doença cardiovascular. Neste contexto, o objetivo deste estudo foi avaliar e caracterizar o perfil lipídico de ácidos gordos de uma amostra de mulheres pós-menopausa e com este, estudar as associações entre o perfil lipídico determinado e parâmetros metabólicos de risco (parâmetros clínicos e bioquímicos). Inicialmente, os ácidos gordos foram extraídos da matriz plasmática através da derivatização destes e a sua composição percentual no plasma foi determinada com recurso a cromatografia gasosa com deteção de ionização de chama. De seguida, através do software IBM SPSS Statistics 21, foram estabelecidas associações entre os parâmetros clínicos e bioquímicos e o perfil lipídico determinado. A população em estudo foi divida em dois grupos consoante o período de entrada na menopausa (há menos de 7 anos e há 7 anos ou mais). Não há conhecimento de estudos semelhantes ao apresentado, que relacionem todo o perfil de ácidos gordos com parâmetros metabólicos de risco considerando o estado menopausal. Os resultados obtidos mostram que o perfil lipídico influencia vários marcadores metabólicos / endócrinos com relevância clínica que devem ser explorados em futuros ensaios clínicos. Para as mulheres na menopausa há menos de 7 anos foram estabelecidas as seguintes relações: i) entre os ácidos gordos saturados e insaturados cis e os níveis de ALP; ii) entre os ácidos gordos mono e polinsaturados cis e os níveis de GGT, IL10 e estradiol; iii) entre os ácidos gordos polinsaturados trans e o IMC e os níveis de IL6; iv) entre os ómegas 3 e os níveis de IL10 e ácido úrico; v) entre os ómegas 6 e os níveis de estradiol, ALP e GGT; vi) entre os ómegas 9 e os níveis de estradiol e GGT; vi) entre os ácidos gordos de curta cadeia e os níveis de colesterol total, LDL, triglicerídeos e IL10; vii) entre os ácidos gordos saturados de cadeia longa e o ΣÁcido láurico, mirístico, palmítico e esteárico e os níveis de triglicerídeos, ALP e GGT; viii) os níveis de IL10 podem ser simultaneamente associados com os ácidos gordos de curta cadeia e os ómegas 3. Para as mulheres na menopausa há 7 anos ou mais foram estabelecidas relações: i) entre os ómegas 3 e o IMC e os níveis de triglicerídeos; ii) entre os ácidos gordos monoinsaturados cis e os ómegas 9 com os níveis de ALT. Relações independentes do estado menopausal também foram estabelecidas, nomeadamente: i) entre os ácidos gordos polinsaturados cis e ómegas 6 e os níveis de ALT, triglicerídeos e AST; ii) entre os níveis de ácidos gordos monoinsaturados cis e ómegas 9 e os níveis de AST e triglicerídeos. O perfil lipídico de ácidos gordos pode ser considerado um biomarcador para a condição de saúde da mulher na menopausa.