890 resultados para scoliotic spine


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Both sexes of a new genus and species of Ectinosomatidae (Copepoda, Harpacticoida) from sublittoral sediments collected on the inner continental shelf in Ubatuba, Sao Paulo State (Brazil) are described in detail. Chaulionyx gen. n. (type species: C. paivacarvalhoi sp. n.) differs from all known genera in the presence of a conspicuous bifid spine on the prehensile P1 endopod. It can be differentiated from other genera with a prehensile endopod (Halophytophilus Brian, 1919; Bradyellopsis Brian, 1925; Klieosoma Hicks & Schriever, 1985) by the presence of distinctive subrectangular middorsal pores on the urosomites and the unarmed male sixth legs. The genus Lineosoma Wells, 1965 is recognized as a paraphyletic taxon and relegated to a junior subjective synonym of Noodtiella Wells, 1965. Arenosetella pectinata Chappuis, 1954a is removed from its floating position in Ectinosomoides Nicholls, 1945, transferred to the genus Noodtiella as N. pectinata comb. n. and considered the senior subjective synonym of N. toukae Mitwally & Montagna, 2001. Dichotomous keys are provided for the identification of the 18 valid species of Noodtiella and the 21 valid genera of the family Ectinosomatidae. Halophytophilus aberrans Wells & Rao, 1987 is placed species incertae sedis in the family.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A new genus and species of Normanellidae (Copepoda, Harpacticoida), Paranaiara inajae gen. et sp. nov., is described from the continental shelf off the northern coast of Sao Paulo State, Brazil. The new genus differs from the type genus Normanella Brady, 1880 and Sagamiella Lee & Huys, 1999 in its presence of lamelliform caudal rami, a maxillulary endopod represented by 2 setae, an unarmed maxillipedal syncoxa, and reduced setation on P2 enp-2 (without outer spine) and P3 enp-2 (with only 2 inner setae). All these apomorphic character states are shared with the genus Pseudocletodes Scott & Scott, 1893, formerly placed in the family Nannopodidae (ex Huntemanniidae) and here assigned to the Normanellidae. Pseudocletodes can be differentiated from Paranaiara by the loss of the P1 endopod and of the inner seta on P2-P4 enp-1, the presence of only 2 inner setae on P2 enp-2 (instead of 3) and only 1 inner seta on P4 exp-3 (instead of 2), the presence of a second inner seta on P4 enp-2 (instead of 1), the morphology of the fifth pair of legs which are not medially fused and have only 3 endopodal elements (instead of 4) in the male, and the well developed caudal ramus seta V (instead of rudimentary). It is postulated that prehensility of the P1 endopod was secondarily lost in the common ancestor of Paranaiara and Pseudocletodes. An updated family diagnosis of the Normanellidae and a dichotomous identification key to the 22 currently valid species are presented.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives. A large-scale survey of doses to patients undergoing the most frequent radiological examinations was carried out in health services in Sao Paulo (347 radiological examinations per 1 000 inhabitants), the most populous Brazilian state. Methods. A postal dosimetric kit with thermoluminescence dosimeters was used to evaluate the entrance surface dose (ESD) to patients. A stratified sampling technique applied to the national health database furnished important data on the distribution of equipment and the annual number of examinations. Chest, head (skull and sinus), and spine (cervical, thoracic, and lumbar) examinations were included in the trial. A total of 83 rooms and 868 patients were included, and 1 415 values of ESD were measured. Results. The data show large coefficients of variation in tube charge, giving rise to large variations in ESD values. Also, a series of high ESD values associated with unnecessary localizing fluoroscopy were detected. Diagnostic reference levels were determined, based on the 75th percentile (third quartile) of the ESD distributions. For adult patients, the diagnostic reference levels achieved are very similar to those obtained in international surveys. However, the situation is different for pediatric patients: the ESD values found in this survey are twice as large as the international recommendations for chest radiographs of children. Conclusions. Despite the reduced number of ESD values and rooms for the pediatric patient group, it is recommended that practices in chest examinations be revised and that specific national reference doses and image quality be established after a broader survey is carried out.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Systemic amyloid light-chain (LC) amyloidosis is a disease process characterized by the pathological deposition of monoclonal LCs in tissue. All LC subtypes are capable of fibril formation although lambda chains, particularly those belonging to the lambda 6 type, are overrepresented. Here, we report the thermodynamic and in vitro fibrillogenic properties of several mutants of the lambda 6 protein 6aJL2 in which Pro7 and/or His8 was substituted by Ser or Pro. The H8P and H8S mutants were almost as stable as the wildtype protein and were poorly fibrillogenic. In contrast, the P7S mutation decreased the thermodynamic stability of 6aJL2 and greatly enhanced its capacity to form amyloid-like fibrils in vitro. The crystal structure of the P7S mutant showed that the substitution induced both local and long-distance effects, such as the rearrangement of the V(L) (variable region of the light chain)-V(L) interface. This mutant crystallized in two orthorhombic polymorphs, P2(1)2(1)2(1) and C222(1). In the latter, a monomer that was not arranged in the typical Bence-Jones dimer was observed for the first time. Crystal-packing analysis of the C222(1) lattice showed the establishment of intermolecular beta-beta interactions that involved the N-terminus and beta-strand B and that these could be relevant in the mechanism of LC fibril formation. Our results strongly suggest that Pro7 is a key residue in the conformation of the N-terminal sheet switch motif and, through long-distance interactions, is also critically involved in the contacts that stabilized the V(L) interface in lambda 6 LCs. (C) 2009 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Physical Activity (PA) and functional fitness (FF) are predictors of a healthy and independent lifestyle in older adults. The purpose of this study was: (1) to construct reference values for FF; (2) to describe sex- and age-related changes in FF, balance, gait, PA, body composition, and bone health/strength; and (3) to determine their variation and co-variation with respect to PA. This cross-sectional study included 401 males and 401 females aged 60-79 years old. FF was assessed using the Senior Fitness test and balance by the Fullerton Advance Balance scale (FAB). Gait parameters: gait velocity (GV), stride length (SL), cadence and gait stability ratio (GSR) were measured. Femoral strength index (FSI) and bone mineral density (BMD) of the total body, lumbar spine, hip region and total lean tissue mass (TLTM) and total fat mass (TFM) were determined by dual-energy x-ray absorptiometry-DXA. PA was assessed during face-to-face interviews using the Baecke questionnaire. Demographic and health history information were obtained by structured telephone interview. In both sexes, a significant main effect for age-group was found for FF parameters, balance scores, gait performances, TLTM and hip, LS and total BMD and FSI. Likewise there were significant main effects for age-group for total PA in women and sports related PA in men. Men scored significantly better than women in FF (except in upper- and lower-body flexibility), balance, GV, SL, GSR and had higher BMD and TLTM compared with women. Active subjects scored better in FF, balance, and gait than their average and non-active peers. PA and FF exerted only a minor influence in the differentiation of BMD and FSI among the elderly while constitutive factors like age, height, body mass, TLTM and TFM entered as the most significant contributors. This study gives scientific support to public policies at the community level, targeted to increase PA, FF and TLTM, thereby contributing to improved quality of life in older adults.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The Ankylosing Spondylitis (AS) is a chronic inflammatory disease that primarily affects the axial skeleton, leading to limitation of spine mobility and functional disability. Physical therapy, especially exercise, is an important part in your treatment. The Global Postural Reeducation(GPR),a method that uses stretching based on evaluation of muscular chains, with significant interference in postural changes may be a complementary alternative for the treatment of this disease. The aim was to evaluate the effects of Global Postural Reeducation (GPR) in patients with Ankylosing Spondylitis (AS) and compare GPR with group conventional segmental self-stretching and breathing exercises. This is a controlled interventional study of 38 patients divided into 2 groups: a GPR group (n = 22) and a control group (n = 16). Both groups were treated over four months. With the GPR group patients, positions that stretched the shortened muscle chains were used. With the control group patients, conventional segmental self-stretching and breathing exercises were performed. The variables analyzed were: pain intensity, morning stiffness, spine mobility, chest expansion, functional capacity (Health Assessment Questionnaire - Spondyloarthropathies - HAQ-S), quality of life (Medical Outcome Study Short Form 36 Healthy Survey-SF-36), and disease activity (Bath Ankylosing Spondylitis Disease Activity Index - BASDAI). Statistical analysis was used with a significance level of p < 0.05. There was a statistically significant difference for all the parameters analyzed between pre and post-treatment in both groups. In the inter-group comparison the GPR group showed a statistically significant improvement in morning stiffness (p = 0.01), spine mobility parameters, except finger-floor distance (p = 0.11), in chest expansion (p = 0.02), and in the physical aspect component of the SF-36 (p = 0.00).Finally, we observed that this sample of patients with AS ,treatment with RPG 60 seems to have a better response in some clinical measures, than the conventional self stretching performed in groups. Further studies are needed to further evaluate this therapeutic alternative in the EA

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A new species of the mailed catfish genus Harttia is described from the Sao Francisco River drainage, States of Minas Gerais and Bahia, Brazil. The new species is distinguished from congeners by the combination of an abdominal region covered by small bony plates; plates 3-4 times in eye diameter; interorbital width 3.1-4.0 in head length and greater than eye diameter; body width at anal fin origin 6.3-8.3 in standard length; margins of the head and pectoral fin spine of mature males with elongate and conspicuous odontodes; anal fin of males longer than of females. A key to Harttia species and a comparison with other species are provided.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study aimed to assess the student-furniture interface from anthropometric parameters of the sitting posture. The sample was composed of 887 students from two public schools in the State of Parana - Brazil, which attended children from 7 to 17 years of age. The data collection used anthropometric measures of the sitting position, a questionnaire containing a human body diagram for indication of discomfort areas and photographic records to verify postural and ergonomic inadequacies in classroom. The following anthropometric variables were measured: popliteal height, sacro-popliteal length, hip width, lumbar support height, and elbow and thigh height. Percentiles 5 and 95 of anthropometric variables showed differences statistically significant, with variation coefficient greater than 30%. In relation to body discomfort, the highest occurrences were recorded for ankle, knees and shoulder joints as well as for spine and buttocks. It was concluded that children use school furniture that does not meet their anthropometric standards, which favored the adoption of incorrect postures and contributed to the emergence of musculoskeletal problems that can interfere with their educational process.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Identificaram-se, por ultrassonografia, os ovários fetais e o sexo dos fetos em uma loba-guará. Ao exame ultrassonográfico, foi possível identificar estruturas fetais e realizar medidas (relação entre diâmetro cranial e abdominal dos fetos) que indicavam idade fetal de 59 dias. Observaram-se: estruturas torácicas e abdominais formadas, diafragma, membros, estruturas do crânio definidas, coluna vertebral, medula, costelas, batimentos cardíacos normais, movimentação fetal, câmaras e valvas cardíacas, grandes vasos, rins, peristaltismo intestinal e ovários fetais. O exame ultrassonográfico foi eficaz nessa espécie, pois foi possível observar estruturas fetais para a avaliação da viabilidade fetal e, também, identificou-se a imagem ovariana em um dos fetos, mostrando-se importante para estudos de sexagem fetal.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A posição sentada é a mais adotada nos ambientes de trabalho, na escola e nas atividades de lazer. Porém, a manutenção prolongada dessa posição ocasiona a adoção de posturas inadequadas e sobrecarrega as estruturas do sistema musculoesquelético, o que pode acarretar dor e lesão na coluna lombar. A presente revisão teve como objetivo identificar os fatores biomecânicos, ergonômicos e clínicos envolvidos na sustentação da postura sentada. Para isso, foram consultadas as bases de dados ISI Web of Knowledge, Medline, Pubmed e EBSCO Host, sendo selecionados 72 artigos publicados entre 1965 e 2010. Foi possível identificar que na posição sentada não existe uma postura ideal a ser sustentada, mas algumas posturas são mais recomendadas do que outras, tal como a postura sentada ereta e a postura lordótica. As cadeiras influenciam o padrão da posição sentada: conforme seu design, pode permitir maior variedade de posturas. Modificações na cadeira e a utilização de exercícios para o aumento da resistência muscular e da propriocepção, bem como a reeducação postural, são intervenções úteis para reduzir o impacto causado pela posição sentada prolongada no sistema musculoesquelético.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Os objetivos do estudo foram avaliar o alinhamento, no plano sagital, da coluna de indivíduos com alterações na medida da gibosidade, comparando com um grupo sem alterações; testar a confiabilidade do instrumento utilizado e verificar se existem correlações entre as medidas da gibosidade e os valores das curvaturas vertebrais. Foram avaliados 40 jovens, divididos em grupo controle - ausência ou presença de gibosidades inferiores a 0,5 cm na curvatura torácica e 0,7 cm na lombar (n=20) e, grupo experimental - gibosidades superiores às descritas (n=20). A gibosidade e as curvaturas no plano sagital foram mensuradas com um instrumento adaptado a um nível d'água e o teste de Adams. As coletas foram realizadas em duas datas distintas, nos dois grupos. Após aplicação do teste Mann-Whitney não foi encontrada diferença entre as ocasiões de coletas e, emparelhando-se os grupos, foi encontrada diferença apenas na medida cervical. Na verificação de existência de relação entre as medidas coletadas, foi encontrada correlação linear (Spearmann) no grupo controle - curvatura torácica e gibosidade torácica; em ambos os grupos - curvaturas torácica e lombar; e no grupo experimental - gibosidade torácica e as curvaturas lombar e sacral e, curvatura sacral e curvaturas torácica e lombar. Pôde-se concluir que a medida da gibosidade tem relações com as curvaturas no plano sagital. Por ser um método confiável, simples e acessível, pode ser reproduzido sem altos custos financeiros e sem causar prejuízo à saúde do paciente.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The construction of wells is one of the most important activities of the oil industry. The drilling process is the set of activities and operations to design, program and perform the opening thereof. During this process, the cuttings are removed by the drilling fluid, or mud, and carted to the surface. This fluid is injected into the drill string and returns to the surface through the annular space between the well walls and the drill string. After the descent of the column casing, the annular space between the casing string and the walls of the borehole is filled with cement so as to secure the spine and prevent any migration of fluids between the various permeable zones traversed by the well behind of the coating. To ensure the good quality of the cementation scrubbers are used mattresses which are pumped ahead of the cement slurry so as to avoid contamination of the drilling fluid paste, or vice versa, and assist in the removal of plaster, formed by drilling fluid of the borehole walls, thus enabling a better cement bond to the well. Within this context, this work aims to evaluate the efficiency of mattresses scrubbers, the basis of ionic and nonionic surfactants, on the removal of nonaqueous drilling fluid, based on n-paraffin in oil wells, and the compatibility between the Mattress relations washer / drilling fluid bed scrubber / cement paste mattress washer / cement slurry / drilling fluid and the drilling fluid / cement slurry using laboratory tests rheology, thickening time and compressive strength. Also technique was performed X-ray diffraction (XRD) for a more detailed analysis of these mixtures with hydrated cement paste. In compatibility tests the conditions of temperature and pressure used in the same laboratory procedure simulating the conditions of oil wells, the well is considered the depth of 800 m. The results showed that the compositions of the mattress washer nonionic, KMS obtained a 100% efficient in removing the non-aqueous drilling fluid, and the best formulation showed good results with respect to compliance testing

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A diminuição da densidade mineral óssea das vértebras, própria do processo de envelhecimento e que pode ser agravada pela osteoporose, determina uma diminuição da região anterior dos corpos vertebrais, resultando em compressão e colapso dessas vértebras, com maior estreitamento dos discos e espaços intervertebrais. Essas novas condições interferem no funcionamento normal de órgãos e sistemas do organismo. O objetivo foi avaliar o grau de cifose torácica e a capacidade funcional de mulheres idosas com e sem osteoporose. Foram avaliadas 30 idosas ativas fisicamente, sendo 20 sem osteoporose ( GSO: 65,1± 4,67 anos) e 10 idosas com osteoporose (GCO: 68,6± 6,46anos). Foram avaliados a medida da cifose torácica, teste de caminhada de seis minutos (TC6'), Timed Up and go (TUG) e força dos músculos respiratórios (PImáx e PEmáx). Os dados obtidos foram analisados utilizando o teste t de Student. O nível de significância utilizado foi de 5% (α£ 0,05). Houve diferença significativa entre os grupos sem (GSO) e com osteoporose (GCO) somente no TC6'(GSO: 426,63±46,36 m; GCO: 392,64±36,68 m , α =0,02). As outras variáveis analisadas não apresentaram diferença significativa (Cifose torácica: α = 0,17; TUG: α =0,49; PImax: α =0,45; PEmax: α =0,19). A osteoporose não influenciou o grau de cifose torácica, a força dos músculos respiratórios e mobilidade das idosas. Entretanto, o desempenho no TC6' foi influenciado negativamente pela osteoporose.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJETIVO: Avaliação de condições dos equipamentos e dosimetria em setores de tomografia computadorizada utilizando protocolos de cabeça, abdome e coluna lombar em pacientes adultos (em três equipamentos distintos) e pediátricos com até um ano e meio de vida (em um dos equipamentos avaliados). MATERIAIS E MÉTODOS: Foram estimados o índice de dose em tomografia computadorizada e a dose média em cortes múltiplos, em exames com pacientes adultos, em três distintos equipamentos. Ainda foram estimadas as doses na superfície de entrada e as doses absorvidas em exame de cabeça para pacientes adultos e pediátricos em um dos equipamentos avaliados. RESULTADOS: Foram realizados testes de controle de qualidade, mecânicos, demonstrando que os equipamentos satisfazem as especificações de uso estabelecidas pelas normas vigentes. Os resultados da dosimetria mostraram que valores de dose média em cortes múltiplos excederam em até 109,0% os valores de níveis de referência, apresentando consideráveis variações entre os equipamentos avaliados neste estudo. As doses absorvidas obtidas com protocolos pediátricos são inferiores aos de pacientes adultos, apresentando redução de até 51,0% na tireoide. CONCLUSÃO: Neste estudo foram avaliadas as condições de operação de três equipamentos tomográficos, estabelecendo quais parâmetros devem ser trabalhados para a implantação de um programa de controle de qualidade nas instituições onde esta pesquisa foi desenvolvida.