998 resultados para mode-locked laser
Resumo:
The use of a solar photovoltaic (PV) panel simulator can be a valued tool for the design and evaluation of the several components of a photovoltaic system. This simulator is based on power electronic converter controlled in such a way that will behave as a PV panel. Thus, in this paper a PV panel simulator based on a two quadrant DC/DC power converter is proposed. This topology will allow to achieve fast responses, like suddenly changes in the irradiation and temperature. To control the power converter it will be used a fast and robust sliding mode controller. Therefore, with the proposed system I-V curve simulation of a PV panel is obtained. Experimental results from a laboratory prototype are presented in order to confirm the theoretical operation.
Resumo:
A exploração do meio subaquático utilizando visão computacional é ainda um processo complexo. Geralmente são utilizados sistemas de visão baseados em visão stereo, no entanto, esta abordagem apresenta limitações, é pouco precisa e é exigente em termos computacionais quando o meio de operação é o subaquático. Estas limitações surgem principalmente em dois cenários de aplicação: quando existe escassez de iluminação e em operações junto a infraestruturas subaquáticas. Consequentemente, a solução reside na utilização de fontes de informação sensorial alternativas ou complementares ao sistema de visão computacional. Neste trabalho propõe-se o desenvolvimento de um sistema de percepção subaquático que combina uma câmara e um projetor laser de um feixe em linha, onde o projetor de luz estruturada _e utilizado como fonte de informação. Em qualquer sistema de visão computacional, e ainda mais relevante em sistemas baseados em triangulação, a sua correta calibração toma um papel fulcral para a qualidade das medidas obtidas com o sistema. A calibração do sistema de visão laser foi dividida em duas etapas. A primeira etapa diz respeito à calibração da câmara, onde são definidos os parâmetros intrínsecos e os parâmetros extrínsecos relativos a este sensor. A segunda etapa define a relação entre a câmara e o laser, sendo esta etapa necessária para a obtenção de imagens tridimensionais. Assim, um dos principais desafios desta dissertação passou por resolver o problema da calibração inerente a este sistema. Desse modo, foi desenvolvida uma ferramenta que requer, pelo menos duas fotos do padrão de xadrez, com perspectivas diferentes. O método proposto foi caracterizado e validado em ambientes secos e subaquáticos. Os resultados obtidos mostram que o sistema _e preciso e os valores de profundidade obtidos apresentam um erro significativamente baixo (inferiores a 1 mm), mesmo com uma base-line (distância entre a centro óptico da câmara e o plano de incidência do laser) reduzida.
Optimização da focagem de feixes laser em tecidos biológicos: desenvolvimento de um simulador óptico
Resumo:
Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para obtenção do grau de Mestre em Engenharia Biomédica
Resumo:
Dissertação de Mestrado em Conservação e Restauro - Metais
Resumo:
O presente trabalho visa apresentar a temática da otimização da produção de corte laser numa empresa do ramo da indústria metalomecânica, denominada Sermec Laser e situada no concelho da Maia no Distrito do Porto. Para alcançar este objetivo foi necessário conhecer o funcionamento atual do processo, como por exemplo, os seus intervenientes, as taxas de ocupação do equipamento de corte a laser e os procedimentos. Só depois de ser explorada essa vertente será possível desenvolver um plano com vista a melhorar esse processo. Este projeto espera criar um plano de melhoria que será testado e, quando for validado, será implementado. As melhorias propostas por este plano passam pelo aumento da eficiência do processo de corte a laser e a alteração de parte do layout da empresa de forma a facilitar e agilizar este mesmo processo. O objetivo final será acrescentar mais valor ao processo, reduzindo os seus desperdícios. Com esta melhoria a empresa ficará a ganhar, pois irá produzir de forma mais ajustada às suas necessidades.
Resumo:
Accepted in 13th IEEE Symposium on Embedded Systems for Real-Time Multimedia (ESTIMedia 2015), Amsterdam, Netherlands.
Resumo:
The treatment of vascular lesions of the tongue is a very challenging procedure since the maintenance of the lingual tissue is of critical importance. Numerous treatment options have been described in literature but the Nd:YAG Laser appears to be one of the safest therapeutic options. We described a successful treatment of vascular lesions of the tongue with an excellent clinical result after only one treatment session with the Nd:YAG laser, with conservation of the lingual tissue and its functionality.
Resumo:
The adhesive bonding technique enables both weight and complexity reduction in structures that require some joining technique to be used on account of fabrication/component shape issues. Because of this, adhesive bonding is also one of the main repair methods for metal and composite structures by the strap and scarf configurations. The availability of strength prediction techniques for adhesive joints is essential for their generalized application and it can rely on different approaches, such as mechanics of materials, conventional fracture mechanics or damage mechanics. These two last techniques depend on the measurement of the fracture toughness (GC) of materials. Within the framework of damage mechanics, a valid option is the use of Cohesive Zone Modelling (CZM) coupled with Finite Element (FE) analyses. In this work, CZM laws for adhesive joints considering three adhesives with varying ductility were estimated. The End-Notched Flexure (ENF) test geometry was selected based on overall test simplicity and results accuracy. The adhesives Araldite® AV138, Araldite® 2015 and Sikaforce® 7752 were studied between high-strength aluminium adherends. Estimation of the CZM laws was carried out by an inverse methodology based on a curve fitting procedure, which enabled a precise estimation of the adhesive joints’ behaviour. The work allowed to conclude that a unique set of shear fracture toughness (GIIC) and shear cohesive strength (ts0) exists for each specimen that accurately reproduces the adhesive layer’ behaviour. With this information, the accurate strength prediction of adhesive joints in shear is made possible by CZM.
Resumo:
OBJETIVO: Avaliar a eficácia, a taxa de recorrência e as complicações da vaporização laser com CO2 no tratamento dos cistos da glândula de Bartholin. MÉTODOS: Estudo retrospectivo com 127 pacientes que apresentavam cistos sintomáticos da glândula de Bartholin submetidas à vaporização laser CO2 na nossa instituição de janeiro de 2005 a junho de 2011. Foram excluídas todas as pacientes com abcessos da glândula de Bartholin ou com suspeita de câncer. Todos os procedimentos foram realizados em regime ambulatorial, sob anestesia local. A coleta dos dados foi feita com base na consulta do processo clínico, tendo-se procedido à análise das características demográficas, dos parâmetros anatômicos, das complicações intra e pós-operatórias e dos dados de acompanhamento. Os dados foram armazenados e analisados no software Microsoft Excel® 2007, e os resultados foram apresentados como frequência (porcentagem) ou média±desvio padrão. As taxas de complicações, recorrência e cura foram calculadas. RESULTADOS: A idade média das pacientes foi de 37,3±9,5 anos (variando entre 18 e 61 anos). Setenta por cento(n=85) delas eram multíparas. A queixa mais frequente foi dor e 47,2% (n=60) das pacientes tinham antecedentes de tratamento médico e/ou cirúrgico por abcesso da glândula de Bartholin. A dimensão média dos cistos foi de 2,7±0,9 cm. Foram verificados três (2,4%) casos de hemorragia intraoperatória ligeira e 17 (13,4%) recorrências durante um período médio de 14,6 meses (variando entre 1 e 56 meses): dez abscessos da glândula de Bartholin e sete cistos recorrentes, que precisavam de uma nova intervenção cirúrgica. A taxa de cura após um único tratamento à laser foi de 86,6%. Dentre as cinco pacientes com doença recorrente que foram submetidas a um segundo procedimento com laser, a taxa de cura foi de 100%. CONCLUSÕES: Na presente instituição, a vaporização laser com CO2 parece ser uma opção terapêutica segura e eficaz no tratamento dos cistos da glândula de Bartholin.
Resumo:
Dissertação para obtenção do Grau de Mestre em Engenharia de Materiais
Resumo:
Dissertação para obtenção do grau de Mestre em Engenharia Electrotécnica e de Computadores
Resumo:
Dissertation submitted in partial fulfillment of the requirements for the Degree of Master of Science in Geospatial Technologies.
Resumo:
Dissertation submitted in partial fulfillment of the requirements for the Degree of Master of Science in Geospatial Technologies.
Resumo:
Involuntary rhythmic leg movements in childhood is an uncommon condition, the generators of which remain unknown. We report on a male 3 years of age with distinct features providing important clues concerning the location of one of these generators. At the age of 7 months, the previously healthy young male started with low frequency, rhythmic, and continuous (both during wakefulness and sleep) flexion/extension movements of the lower limbs. Movements interfered significantly with gait acquisition, and, despite normal cognitive development, he was able to walk only at age 2 years, 4 months. The neurologic examination revealed the absence of automatic stepping in the neonatal period, but was otherwise normal. A polygraphic electroencephalogram/electromyogram EEG/EMG) recording, at the age of 2 years, 9 months, revealed rhythmic and synchronous legs with EMG activity at 0.5 Hz. A more complete polygraphic recording at the age of 3 years, 10 months, showed a lower frequency (0.35 Hz) for the movements, which were time-locked with the respiratory cycle. Magnetic resonance imaging (MRI) of the brain revealed an increased T2 signal in the upper medulla-lower pons regions. The generator of the rhythmic legs movements is postulated to be the respiratory center, connecting with the reticulospinal projecting neurons through an aberrant pathway.
Resumo:
Introdução: A fasceíte plantar (FP) constitui a causa mais frequente de dor no retropé. Está recomendada uma prova terapêutica inicial conservadora. Objetivos: Caraterizar fatores demográficos e sintomáticos, terapêutica prévia e resultados de monoterapia com laser. Material e Métodos: Estudo observacional retrospetivo (12 meses). O tratamento aplicado foi laser infravermelho (AsGa 904nm; densidade de energia 20J/cm2; potência de pico 200mW). Fez-se análise estatística descritiva e comparativa (nível de significância de 0,05). Resultados: Seguiram-se 32 doentes com FP, com idade média de 54,28 anos (24–86; DP 13,95), 66% mulheres, Índice de Massa Corporal (IMC) médio de 30,18Kg/m2 (17,91-41,13; DP 5,19), 75% unilaterais, tempo médio de evolução de 6,28 meses (0,2-24; DP 6,82), 21 tinham feito previamente farmacoterapia e 12 outros tratamentos de MFR. O nível de dor inicial (END) médio foi 7,31 (5-10; DP 1,38). Dos 26 doentes tratados (6 perdas), 24 (92,3%) reportaram melhoria. O número médio de sessões foi 28,5 (11– 60; DP 14,01). O nível médio de dor final foi 0,75 (0-5; DP 2,37), com melhoria média de 89,7% (28,6%-100%; DP 0,16) do nível de dor. A intensidade de dor inicial foi maior em doentes com IMC superior (p=0,002). Não se encontraram outras relações estatisticamente significativas. Conclusões: A FP caraterizou-se por um nível de dor significativo (moderado a grave). A obesidade pareceu ser um fator de risco. A taxa de melhoria com o tratamento com laser foi muito satisfatória. A terapia com laser de baixa intensidade IV constitui uma boa opção terapêutica, a justificar avaliação suplementar por ensaios prospetivos controlados e randomizados.