868 resultados para least-square
Resumo:
The study aimed at verifying the associated factors of self-perceived body changes in adults living with HIV in highly-active antiretroviral therapy (HAART) in the city of Sao Paulo, Brazil. This cross-sectional study was conducted among people living with HIV on HAART for at least three months. A standardized questionnaire was used for assessing self-perceived body changes. Associated factors relating to self-reported body changes in people living with HIV (PLHIV) were assessed with Student`s t-test and chi-square test. In total, 507 patients were evaluated. The mean time since diagnosis was 6.6 years [standard deviation (SD)+/-4.1], and the mean duration of HAART was 5.1 years (SD+/-3.3). Self-perceived body changes were reported by 79.5% of the participants and were associated with viral load and duration of HAART. Fibre intake was lower among males who gained in abdominal fat (p=0.035). HAART-related body changes were reported by the large majority of the population and were associated with demographic and clinical variables.
Resumo:
Evolutionary change in New World Monkey (NWM) skulls occurred primarily along the line of least resistance defined by size (including allometric) variation (g(max)). Although the direction of evolution was aligned with this axis, it was not clear whether this macroevolutionary pattern results from the conservation of within population genetic covariance patterns (long-term constraint) or long-term selection along a size dimension, or whether both, constraints and selection, were inextricably involved. Furthermore, G-matrix stability can also be a consequence of selection, which implies that both, constraints embodied in g(max) and evolutionary changes observed on the trait averages, would be influenced by selection Here, we describe a combination of approaches that allows one to test whether any particular instance of size evolution is a correlated by-product due to constraints (g(max)) or is due to direct selection on size and apply it to NWM lineages as a case study. The approach is based on comparing the direction and amount of evolutionary change produced by two different simulated sets of net-selection gradients (beta), a size (isometric and allometric size) and a nonsize set. Using this approach it is possible to distinguish between the two hypotheses (indirect size evolution due to constraints or direct selection on size), because although both may produce an evolutionary response aligned with g(max), the amount of change produced by random selection operating through the variance/covariance patterns (constraints hypothesis) will be much smaller than that produced by selection on size (selection hypothesis). Furthermore, the alignment of simulated evolutionary changes with g(max) when selection is not on size is not as tight as when selection is actually on size, allowing a statistical test of whether a particular observed case of evolution along the line of least resistance is the result of selection along it or not. Also, with matrix diagonalization (principal components [PC]) it is possible to calculate directly the net-selection gradient on size alone (first PC [PC1]) by dividing the amount of phenotypic difference between any two populations by the amount of variation in PC1, which allows one to benchmark whether selection was on size or not
Resumo:
In this paper we deal with robust inference in heteroscedastic measurement error models Rather than the normal distribution we postulate a Student t distribution for the observed variables Maximum likelihood estimates are computed numerically Consistent estimation of the asymptotic covariance matrices of the maximum likelihood and generalized least squares estimators is also discussed Three test statistics are proposed for testing hypotheses of interest with the asymptotic chi-square distribution which guarantees correct asymptotic significance levels Results of simulations and an application to a real data set are also reported (C) 2009 The Korean Statistical Society Published by Elsevier B V All rights reserved
Resumo:
The representation of interfaces by means of the algebraic moving-least-squares (AMLS) technique is addressed. This technique, in which the interface is represented by an unconnected set of points, is interesting for evolving fluid interfaces since there is]to surface connectivity. The position of the surface points can thus be updated without concerns about the quality of any surface triangulation. We introduce a novel AMLS technique especially designed for evolving-interfaces applications that we denote RAMLS (for Robust AMLS). The main advantages with respect to previous AMLS techniques are: increased robustness, computational efficiency, and being free of user-tuned parameters. Further, we propose a new front-tracking method based on the Lagrangian advection of the unconnected point set that defines the RAMLS surface. We assume that a background Eulerian grid is defined with some grid spacing h. The advection of the point set makes the surface evolve in time. The point cloud can be regenerated at any time (in particular, we regenerate it each time step) by intersecting the gridlines with the evolved surface, which guarantees that the density of points on the surface is always well balanced. The intersection algorithm is essentially a ray-tracing algorithm, well-studied in computer graphics, in which a line (ray) is traced so as to detect all intersections with a surface. Also, the tracing of each gridline is independent and can thus be performed in parallel. Several tests are reported assessing first the accuracy of the proposed RAMLS technique, and then of the front-tracking method based on it. Comparison with previous Eulerian, Lagrangian and hybrid techniques encourage further development of the proposed method for fluid mechanics applications. (C) 2008 Elsevier Inc. All rights reserved.
Resumo:
We analyze a threshold contact process on a square lattice in which particles are created on empty sites with at least two neighboring particles and are annihilated spontaneously. We show by means of Monte Carlo simulations that the process undergoes a discontinuous phase transition at a definite value of the annihilation parameter, in accordance with the Gibbs phase rule, and that the discontinuous transition exhibits critical behavior. The simulations were performed by using boundary conditions in which the sites of the border of the lattice are permanently occupied by particles.
Resumo:
Under p = c, we prove that it is possible to endow the free abelian group of cardinality c with a group topology that makes its square countably compact. This answers a question posed by Madariaga-Garcia and Tomita and by Tkachenko. We also prove that there exists a Wallace semigroup (i.e., a countably compact both-sided cancellative topological semigroup which is not a topological group) whose square is countably compact. This answers a question posed by Grant.
Resumo:
This work describes the development and optimization of a sequential injection method to automate the determination of paraquat by square-wave voltammetry employing a hanging mercury drop electrode. Automation by sequential injection enhanced the sampling throughput, improving the sensitivity and precision of the measurements as a consequence of the highly reproducible and efficient conditions of mass transport of the analyte toward the electrode surface. For instance, 212 analyses can be made per hour if the sample/standard solution is prepared off-line and the sequential injection system is used just to inject the solution towards the flow cell. In-line sample conditioning reduces the sampling frequency to 44 h(-1). Experiments were performed in 0.10 M NaCl, which was the carrier solution, using a frequency of 200 Hz, a pulse height of 25 mV, a potential step of 2 mV, and a flow rate of 100 mu L s(-1). For a concentration range between 0.010 and 0.25 mg L(-1), the current (i(p), mu A) read at the potential corresponding to the peak maximum fitted the following linear equation with the paraquat concentration (mg L(-1)): ip = (-20.5 +/- 0.3) Cparaquat -(0.02 +/- 0.03). The limits of detection and quantification were 2.0 and 7.0 mu g L(-1), respectively. The accuracy of the method was evaluated by recovery studies using spiked water samples that were also analyzed by molecular absorption spectrophotometry after reduction of paraquat with sodium dithionite in an alkaline medium. No evidence of statistically significant differences between the two methods was observed at the 95% confidence level.
Resumo:
This paper describes the development and evaluation of a sequential injection method to automate the determination of methyl parathion by square wave adsorptive cathodic stripping voltammetry exploiting the concept of monosegmented flow analysis to perform in-line sample conditioning and standard addition. Accumulation and stripping steps are made in the sample medium conditioned with 40 mmol L-1 Britton-Robinson buffer (pH 10) in 0.25 mol L-1 NaNO3. The homogenized mixture is injected at a flow rate of 10 mu Ls(-1) toward the flow cell, which is adapted to the capillary of a hanging drop mercury electrode. After a suitable deposition time, the flow is stopped and the potential is scanned from -0.3 to -1.0 V versus Ag/AgCl at frequency of 250 Hz and pulse height of 25 mV The linear dynamic range is observed for methyl parathion concentrations between 0.010 and 0.50 mgL(-1), with detection and quantification limits of 2 and 7 mu gL(-1), respectively. The sampling throughput is 25 h(-1) if the in line standard addition and sample conditioning protocols are followed, but this frequency can be increased up to 61 h(-1) if the sample is conditioned off-line and quantified using an external calibration curve. The method was applied for determination of methyl parathion in spiked water samples and the accuracy was evaluated either by comparison to high performance liquid chromatography with UV detection, or by the recovery percentages. Although no evidences of statistically significant differences were observed between the expected and obtained concentrations, because of the susceptibility of the method to interference by other pesticides (e.g., parathion, dichlorvos) and natural organic matter (e.g., fulvic and humic acids), isolation of the analyte may be required when more complex sample matrices are encountered. (C) 2007 Elsevier B.V. All rights reserved.
Resumo:
This paper describes a chemotaxonomic analysis of a database of triterpenoid compounds from the Celastraceae family using principal component analysis (PCA). The numbers of occurrences of thirty types of triterpene skeleton in different tribes of the family were used as variables. The study shows that PCA applied to chemical data can contribute to an intrafamilial classification of Celastraceae, once some questionable taxa affinity was observed, from chemotaxonomic inferences about genera and they are in agreement with the phylogeny previously proposed. The inclusion of Hippocrateaceae within Celastraceae is supported by the triterpene chemistry.
Resumo:
The electrochemical oxidation of promethazine hydrochloride was made on highly boron-doped diamond electrodes. Cyclic voltammetry experiments showed that the oxidation mechanisms involved the formation of an adsorbed product that is more readily oxidized, producing a new peak with lower potential values whose intensity can be increased by applying the accumulation potential for given times. The parameters were optimized and the highest current intensities were obtained by applying +0.78 V for 30 seconds. The square-wave adsorptive voltammetry results obtained in BR buffer showed two well-defined peaks, dependent on the pH and on the voltammetric parameters. The best responses were obtained at pH 4.0, frequency of 50 s(-1), step of 2 mV, and amplitude of 50 mV. Under these conditions, linear responses were obtained for concentrations from 5.96 x 10(-7) to 4.76 x 10(-6) mol L-1, and calculated detection limits of 2.66 x 10(-8) mol L-1 (8.51 mu g L-1) for peak 1 and of 4.61 x 10(-8) mol L-1 (14.77 mu g L-1) for peak 2. The precision and accuracy were evaluated by repeatability and reproducibility experiments, which yielded values of less than 5.00% for both voltammetric peaks. ne applicability of this procedure was tested on commercial formulations of promethazine hydrochloride by observing the stability, specificity, recovery and precision of the procedure in complex samples. All results obtained were compared to recommended procedure by British Pharmacopeia. The voltammetric results indicate that the proposed procedure is stable and sensitive, with good reproducibility even when the accumulation steps involve short times. It is therefore very suitable for the development of the electroanalytical procedure, providing adequate sensitivity and a reliable method.
Resumo:
http://digitalcommons.colby.edu/atlasofmaine2006/1003/thumbnail.jpg
Resumo:
A ultra-sonografia obstétrica é um método diagnóstico tradicionalmente utilizado na rotina do atendimento pré-natal, tendo sido estudados de forma ampla suas vantagens e limitações. O advento do diagnóstico intra-uterino de cardiopatias congênitas e de arritmias através da ecocardiografia fetal modificou completamente o prognóstico perinatal dessas afecções, por permitir planejar o adequado manejo cardiológico no período neonatal imediato e, em algumas situações, o tratamento e sua resolução in utero. Sendo muito elevada a prevalência de cardiopatias congênitas durante a vida fetal, sua detecção torna-se fundamental. Considerando a inviabilidade operacional de realizar rotineiramente ecocardiografia fetal em todas as gestações, levando-se em conta as condições locais do sistema de saúde, o encaminhamento para exame por especialista passa a ser otimizado com a possibilidade da suspeita de alterações estruturais ou funcionais do coração e do sistema circulatório durante o exame ultra-sonográfico obstétrico de rotina. Não são conhecidos, em nosso meio, dados que avaliem de forma sistemática a acurácia da ultra-sonografia obstétrica no que se refere à suspeita pré-natal de cardiopatias. A partir deste questionamento, este trabalho foi delineado com o objetivo de avaliar o papel da ultra-sonografia obstétrica de rotina na suspeita pré-natal de cardiopatias congênitas ou arritmias graves e os fatores envolvidos na sua efetividade. A amostra foi constituída de 77 neonatos ou lactentes internados no Instituto de Cardiologia do Rio Grande do Sul / Fundação Universitária de Cardiologia (IC/FUC) no período de maio a outubro de 2000, com diagnóstico pós-natal confirmado de cardiopatia estrutural ou arritmia grave, que tenham sido submetidos, durante a vida fetal, a pelo menos uma ultra-sonografia obstétrica após a 18a semana de gestação. Para a coleta de dados, foi utilizado um questionário padronizado, respondido pelos pais ou responsáveis, após consentimento informado. As variáveis categóricas foram comparadas pelo teste do qui-quadrado ou pelo teste de Fisher, com um alfa crítico de 0,05. Um modelo de regressão logística foi utilizado para determinar variáveis independentes eventualmente envolvidas na suspeita pré-natal de cardiopatia. Em 19 pacientes (24,7%), a ultra-sonografia obstétrica foi capaz de levantar suspeita de anormalidades estruturais ou de arritmias. Ao serem consideradas apenas as cardiopatias congênitas, esta prevalência foi de 19,2% (14/73). Em 73,7% destes, as cardiopatias suspeitadas eram acessíveis ao corte de 4-câmaras isolado. Observou-se que 26,3% das crianças com suspeita pré-natal de cardiopatia apresentaram arritmias durante o estudo ecográfico, enquanto apenas 3,4% dos pacientes sem suspeita pré-natal apresentaram alterações do ritmo (P=0,009). Constituiram-se em fatores comparativos significantes entre o grupo com suspeita pré-natal e o sem suspeita a paridade (P=0,029), o parto cesáreo (P=0,006), a internação em unidade de tratamento intensivo (P=0,046) e a escolaridade paterna (P=0,014). Não se mostraram significativos o número de gestações, a história de abortos prévios, o estado civil, o sexo dos pacientes, o tipo de serviço e a localidade em que foram realizados o pré-natal e a ultra-sonografia obstétrica, a indicação da ecografia, o número de ultra-sonografias realizadas, a renda familiar e a escolaridade materna. À análise multivariada, apenas a presença de alteração do ritmo cardíaco durante a ultra-sonografia obstétrica mostrou-se como variável independente associada à suspeita pré-natal de anormalidade cardíaca. Este trabalho demonstra que a ultra-sonografia obstétrica de rotina ainda tem sido subutilizada no rastreamento pré-natal de cardiopatias congênitas, levantando a suspeita de anormalidades estruturais em apenas um quinto dos casos. Considerando a importância prognóstica do diagnóstico intra-uterino de cardiopatias congênitas e arritmias graves, todos os esforços devem ser mobilizados no sentido de aumentar a eficácia da ecografia obstétrica de rotina para a suspeita de anormalidades cardíacas fetais. O treinamento dirigido dos ultra-sonografistas e a conscientização do meio obstétrico e da própria população são instrumentos para esta ação.
Resumo:
All the demonstrations known to this author of the existence of the Jordan Canonical Form are somewhat complex - usually invoking the use of new spaces, and what not. These demonstrations are usually too difficult for an average Mathematics student to understand how he or she can obtain the Jordan Canonical Form for any square matrix. The method here proposed not only demonstrates the existence of such forms but, additionally, shows how to find them in a step by step manner. I do not claim that the following demonstration is in any way “elegant” (by the standards of elegance in fashion nowadays among mathematicians) but merely simple (undergraduate students taking a fist course in Matrix Algebra would understand how it works).
Resumo:
This paper proposes a method to structurally estimate an auction model using a variation of OLS, under commonly held assumptions in both auction theory and econometrics. In spite of its computational simplicity, the method applies to a wide variety of environments, including interdependent values in general, and certain forms of endogenous participation and bidder asymmetry. Furthermore, it can be used for hypotheses testing about the shape of the valuation distribution, valuation interdependence, or existence of bidder asymmetry.