889 resultados para evaluation of the quality in education
Resumo:
An evaluation of the seismic hazard in La Hispaniola Island has been carried out, as part of the cooperative project SISMO-HAITI, supported by the Technical University of Madrid (UPM) and developed by several Spanish Universities, the National Observatory of Environment and Vulnerability) ONEV of Haiti, and with contributions from the Puerto Rico Seismic Network (PRSN) and University Seismological Institute of Dominican Republic (ISU). The study was aimed at obtaining results suitable for seismic design purposes. It started with the elaboration of a seismic catalogue for the Hispaniola Island, requiring an exhaustive revision of data reported by more than 20 seismic agencies, apart from these from the PRSN and ISU. The final catalogue contains 96 historical earthquakes and 1690 instrumental events, and it was homogenized to moment magnitude, Mw. Seismotectonic models proposed for the region were revised and a new regional zonation was proposed, taking into account geological andtectonic data, seismicity, focal mechanisms, and GPS observations. In parallel, attenuation models for subduction and crustal zones were revised in previous projects and the most suitable for the Caribbean plate were selected. Then, a seismic hazard analysis was developed in terms of peak ground acceleration, PGA, and spectral accelerations, SA (T), for periods of 0.1, 0.2, 0.5, 1 and 2s, using the Probabilistic Seismic Hazard Assessment (PSHA) methodology. As a result, different hazard maps were obtained for the quoted parameters, together with Uniform Hazard Spectra for Port au Prince and the main cities in the country. Hazard deaggregation was also carried out in these towns, for the target motion given by the PGA and SA (1s) obtained for return periods of 475, 975 and 2475 years. Therefore, the controlling earthquakes for short- and long-period target motions were derived. This study was started a few months after the 2010 earthquake, as a response to an aid request from the Haitian government to the UPM, and the results are available for the definition of the first building code in Haiti.
Resumo:
Minimally invasive surgery is a highly demanding surgical approach regarding technical requirements for the surgeon, who must be trained in order to perform a safe surgical intervention. Traditional surgical education in minimally invasive surgery is commonly based on subjective criteria to quantify and evaluate surgical abilities, which could be potentially unsafe for the patient. Authors, surgeons and associations are increasingly demanding the development of more objective assessment tools that can accredit surgeons as technically competent. This paper describes the state of the art in objective assessment methods of surgical skills. It gives an overview on assessment systems based on structured checklists and rating scales, surgical simulators, and instrument motion analysis. As a future work, an objective and automatic assessment method of surgical skills should be standardized as a means towards proficiency-based curricula for training in laparoscopic surgery and its certification.
Resumo:
This work compared the quantification of soluble fibre in feeds using different chemical and in vitro approaches, and studied the potential interference between soluble fibre and mucin determinations. Six ingredients: sugar beet pulp (SBP), SBP pectins, insoluble SBP, wheat straw, sunflower hulls and lignocellulose, and seven rabbit diets, differing in soluble fibre content, were evaluated. In experiment 1, ingredients and diets were analyzed for total dietary fibre (TDF), insoluble dietary fibre (IDF), soluble dietary fibre (SDF), aNDFom (corrected for protein, aNDFom-cp) and 2-step pepsin/pancreatin in vitro DM indigestibility (corrected for ash and protein, ivDMi2). Soluble fibre was estimated by difference using three procedures: TDF?IDF (SDFIDF), TDF?ivDMi2 (SDFivDMi2), and TDF?aNDFom-cp (SDFaNDFom-cp). Soluble fibre determined directly (SDF) or by difference as SDFivDMi2 were not different (109 g/kg DM, on average). However, when it was calculated as SDFaNDFom-cp the value was 40% higher (153 g/kg DM, P menor que 0.05), whereas SDFIDF (124 g/kg DM) did not differ from any of the other methods. The correlation between the four methods was high (r ? 0.96; P ? 0.001; n = 13), but it decreased or even disappeared when SBP pectins and SBP were excluded and a lower and more narrow range of variation of soluble fibre was used. In experiment 2, the ivDMi2 using crucibles (reference method) were compared to those made using individual or collective ankom bags in order to simplify the determination of SDFivDMi2. The ivDMi2 was not different when using crucibles or individual or collective ankom bags. In experiment 3, the potential interference between soluble fibre and intestinal mucin determinations was studied using rabbit intestinal raw mucus, digesta and SBP pectins, lignocelluloses and a rabbit diet. An interference was observed between the determinations of soluble fibre and crude mucin, as contents of TDF and apparent crude mucin were high in SBP pectins (994 and 709 g/kg DM) and rabbit intestinal raw mucus (571 and 739 g/kg DM). After a pectinase treatment, the coefficient of apparent mucin recovery of SBP pectins was close to zero, whereas that of rabbit mucus was not modified. An estimation of the crude mucin carbohydrates retained in digesta TDF is proposed to correct TDF and soluble fibre digestibility. In conclusion, the values of soluble fibre depend on the methodology used. The contamination of crude mucin with soluble fibre is avoided using pectinase.
Resumo:
In this paper, the applicability of the FRA technique is discussed as a method for detecting inter-turn faults in stator windings. Firstly, this method is tested in an individual medium-voltage stator coil with satisfactory results. Secondly, the tests are extended to a medium-voltage induction motor stator winding, in which inter-turn faults are performed in every coil end of one phase. Results of the frequency response in case of inter-turn faults are evaluated in both cases for different fault resistance values. The experimental setup is also described for each experiment. The results of the application of this technique to the detection of inter-turn faults justify further research in optimizing this technique for preventive maintenance.
Resumo:
Governments are working in new policies to slow down total energy consumption and greenhouse gases (GHG) emissions, promoting the deployment of electric vehicles (EVs) in all countries. In order to facilitate this deployment and help to reduce the final costs of their batteries, additional utilization of EVs when those are parked has been proposed. EVs can be used to minimize the total electricity cost of buildings (named vehicle to building applications, V2B). In this paper an economic evaluation of EVs in the Building Energy Management System is shown. The optimal storage capacity and its equivalent number of EVs are determined. This value is then used for determining the optimal charging schedule to be applied to the batteries. From this schedule, the total expected profit is derived for the case of a real hotel in Spain.
Evaluation of the competitiveness of agri-food sector in the región of the Alcarria Conquense(Spain)
Resumo:
The agrifood industry, like other sectors, faces the ongoing challenge of improving their competitiveness in order to strengthen its market presence and cater to the growing global population. This research measures the competitiveness of the agrifood industry in the region of La Alcarria Conquense (Spain), in the framework of the evaluation of programs in the territory that have aimed at improving and enhancing this sector. Through building the competitiveness profiles (Porter, 1990) and cluster analysis we have identified six competitive strategy patterns in food companies in the region. In addition, we have analyzed each of the areas of competitiveness and we can identify the strengths and weaknesses of the sector, and identify recommendations for increasing the responsiveness of the territory. Among the defining characteristics are the lack of association, the limitation on payment systems or virtual absence of training and innovation. However, programs to support the sector are highly valued and reverse in the long-term viability of these companies.
Resumo:
This work presents the first application of total-reflection X-ray fluorescence (TXRF) spectrometry, a new and powerful alternative analytical method, to evaluation of the bioaccumulation kinetics of gold nanorods (GNRs) in various tissues upon intravenous administration in mice. The analytical parameters for developed methodology by TXRF were evaluated by means of the parallel analysis of bovine liver certified reference material samples (BCR-185R) doped with 10 μg/g gold. The average values (n = 5) achieved for gold measurements in lyophilized tissue weight were as follows: recovery 99.7%, expanded uncertainty (k = 2) 7%, repeatability 1.7%, detection limit 112 ng/g, and quantification limit 370 ng/g. The GNR bioaccumulation kinetics was analyzed in several vital mammalian organs such as liver, spleen, brain, and lung at different times. Additionally, urine samples were analyzed to study the kinetics of elimination of the GNRs by this excretion route. The main achievement was clearly differentiating two kinds of behaviors. GNRs were quickly bioaccumulated by highly vascular filtration organs such as liver and spleen, while GNRs do not show a bioaccumulation rates in brain and lung for the period of time investigated. In parallel, urine also shows a lack of GNR accumulation. TXRF has proven to be a powerful, versatile, and precise analytical technique for the evaluation of GNRs content in biological systems and, in a more general way, for any kind of metallic nanoparticles.
Resumo:
The scope of the present paper is the derivation of a merit function which predicts the visual perception of LED spot lights. The color uniformity level Usl is described by a linear regression function of the spatial color distribution in the far field. Hereby, the function is derived from four basic functions. They describe the color uniformity of spot lights through different features. The result is a reliable prediction for the perceived color uniformity in spot lights. A human factor experiment was performed to evaluate the visual preferences for colors and patterns. A perceived rank order was derived from the subjects’ answers and compared with the four basic functions. The correlation between the perceived rank order and the basic functions was calculated resulting in the definition of the merit function Usl. The application of this function is shown by a comparison of visual evaluations and measurements of LED retrofit spot lamps. The results enable a prediction of color uniformity levels of simulations and measurements concerning the visual perception. The function provides a possibility to evaluate the far field of spot lights without individual subjective judgment. © (2014) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Resumo:
The present paper describes the advancement and evaluation of air quality-related impacts with the Atmospheric Evaluation and Research Integrated system for Spain (AERIS). In its current version, AERIS is able to provide estimates on the impacts of air quality over human health (PM2.5 and O3), crops and vegetation (O3). The modules that allow quantifying the before mentioned impacts were modeled by applying different approaches (mostly for the European context) present in scientific literature to the conditions of the Iberian Peninsula. This application was supported by reliable data sources, as well as by the good predictive capacity of AERIS for ambient concentrations. For validation purposes, the estimates of AERIS for impacts on human health (change in the statistical life expectancy-PM2.5) and vegetation (loss of wheat crops-O3) were compared against results from the SERCA project and GAINS estimates for two emission scenarios. In general, good results evidenced by reasonable correlation coefficients were obtained, therefore confirming the adequateness of the followed modeling approaches and the quality of AERIS predictions.
Resumo:
Customer Satisfaction Surveys (CSS) have become an important tool for public transport planners, as improvements in the perceived quality of service lead to greater use of public transport and lower traffic pollution. Until now, Intelligent Transportation System (ITS) enhancements in public transport have traditionally included fleet management systems based on Automatic Vehicle Location (AVL) technologies, which can be used to optimize routing and scheduling, and to feed real-time information into passenger information channels. However, surveys of public transport users could also benefit from the new information technologies. As most customers carry their smartphones when traveling, Quick Response (QR) codes open up the possibility of conducting these surveys at a lower cost.This paper contributes to the limited existing literature by developing the analysis of QR codes applied to CSS in public transport and highlighting their importance in reducing the cost of data collection and processing. The added value of this research is that it provides the first assessment of a real case study in Madrid (Spain) using QR codes for this purpose. This pilot experience was part of a research project analyzing bus service quality in the same case study, so the QR code survey (155 valid questionnaires) was validated using a conventional face-to-face survey (520 valid questionnaires). The results show clearly that, after overcoming a few teething troubles, this QR code application will ultimately provide transport management with a useful tool to reduce survey costs
Resumo:
A procedure for measuring the overheating temperature (ΔT ) of a p-n junction area in the structure of photovoltaic (PV) cells converting laser or solar radiations relative to the ambient temperature has been proposed for the conditions of connecting to an electric load. The basis of the procedure is the measurement of the open-circuit voltage (VO C ) during the initial time period after the fast disconnection of the external resistive load. The simultaneous temperature control on an external heated part of a PV module gives the means for determining the value of VO C at ambient temperature. Comparing it with that measured after switching OFF the load makes the calculation of ΔT possible. Calibration data on the VO C = f(T ) dependences for single-junction AlGaAs/GaAs and triple-junction InGaP/GaAs/Ge PV cells are presented. The temperature dynamics in the PV cells has been determined under flash illumination and during fast commutation of the load. Temperature measurements were taken in two cases: converting continuous laser power by single-junction cells and converting solar power by triple-junction cells operating in the concentrator modules.
Resumo:
Funding The International Primary Care Respiratory Group (IPCRG) provided funding for this research project as an UNLOCK group study for which the funding was obtained through an unrestricted grant by Novartis AG, Basel, Switzerland. The latter funders had no role in study design, data collection and analysis, decision to publish or preparation of the manuscript. Database access for the OPCRD was provided by the Respiratory Effectiveness Group (REG) and Research in Real Life; the OPCRD statistical analysis was funded by REG. The Bocholtz Study was funded by PICASSO for COPD, an initiative of Boehringer Ingelheim, Pfizer and the Caphri Research Institute, Maastricht University, The Netherlands.