997 resultados para Valve spring steel


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A stainless-steel net is used to support a zeolite NaA membrane synthesized using a 'seeded-growth' method. The zeolite and stainless-steel net are tightly integrated (see Figure), showing large-scale order and high mechanical stability. High oxygen permeance and high permselectivity for O-2 over N-2 (about 7) is demonstrated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aims Surgery for infective endocarditis (IE) is associated with high mortality. Our objectives were to describe the experience with surgical treatment for IE in Spain, and to identify predictors of in-hospital mortality. Methods Prospective cohort of 1000 consecutive patients with IE. Data were collected in 26 Spanish hospitals. Results Surgery was performed in 437 patients (43.7%). Patients treated with surgery were younger and predominantly male. They presented fewer comorbid conditions and more often had negative blood cultures and heart failure. In-hospital mortality after surgery was lower than in the medical therapy group (24.3 vs 30.7%, p = 0.02). In patients treated with surgery, endocarditis involved a native valve in 267 patients (61.1%), a prosthetic valve in 122 (27.9%), and a pacemaker lead with no clear further valve involvement in 48 (11.0%). The most common aetiologies were Staphylococcus (186, 42.6%), Streptococcus (97, 22.2%), and Enterococcus (49, 11.2%). The main indications for surgery were heart failure and severe valve regurgitation. A risk score for in-hospital mortality was developed using 7 prognostic variables with a similar predictive value (OR between 1.7 and 2.3): PALSUSE: prosthetic valve, age ≥ 70, large intracardiac destruction, Staphylococcus spp, urgent surgery, sex [female], EuroSCORE ≥ 10. In-hospital mortality ranged from 0% in patients with a PALSUSE score of 0 to 45.4% in patients with PALSUSE score > 3. Conclusions The prognosis of IE surgery is highly variable. The PALSUSE score could help to identify patients with higher in-hospital mortality.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aims to present the conditions related to the European Union’s involvement in the Arab Spring, as well as examine the extent of this capability-based involvement in the first months of 2011 against the background of competence disputes between institutions and inter-governmental contentions. These considerations will be the basis for conclusions on the theoretical and practical viability of the European Union’s action in the region of North Africa, in terms of both interests defined in Brussels and representation of a jointly agreed position and undertaking practical actions in the international arena. These assumptions can facilitate a new perspective for the EU’s strategic approach framework in the region of North Africa.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: Long-term intraocular pressure reduction by glaucoma drainage devices (GDDs) is often limited by the fibrotic capsule that forms around them. Prior work demonstrates that modifying a GDD with a porous membrane promotes a vascularized and more permeable capsule. This work examines the in vitro fluid dynamics of the Ahmed valve after enclosing the outflow tract with a porous membrane of expanded polytetrafluoroethylene (ePTFE). MATERIALS AND METHODS: The control and modified Ahmed implants (termed porous retrofitted implant with modified enclosure or PRIME-Ahmed) were submerged in saline and gelatin and perfused in a system that monitored flow (Q) and pressure (P). Flow rates of 1-50 μl/min were applied and steady state pressure recorded. Resistance was calculated by dividing pressure by flow. RESULTS: Modifying the Ahmed valve implant outflow with expanded ePTFE increased pressure and resistance. Pressure at a flow of 2 μl/min was increased in the PRIME-Ahmed (11.6 ± 1.5 mm Hg) relative to the control implant (6.5 ± 1.2 mm Hg). Resistance at a flow of 2 μl/min was increased in the PRIME-Ahmed (5.8 ± 0.8 mm Hg/μl/min) when compared to the control implant (3.2 ± 0.6 mm Hg/μl/min). CONCLUSIONS: Modifying the outflow tract of the Ahmed valve with a porous membrane adds resistance that decreases with increasing flow. The Ahmed valve implant behaves as a variable resistor. It is partially open at low pressures and provides reduced resistance at physiologic flow rates.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Two cases of Shone syndrome with severe mitral and aortic valve problems and pulmonary hypertension were referred for heart-lung transplantation. Severely elevated pulmonary vascular resistance (PVR) was confirmed as was severe periprosthetic mitral and aortic regurgitation. Based on the severity of the valve lesions in both patients, surgery was decided upon and undertaken. Both experienced early pulmonary hypertensive crises, one more than the other, that gradually subsided, followed by excellent recovery and reversal of pulmonary hypertension and PVR. These cases illustrate Braunwald's concept that pulmonary hypertension secondary to left-sided valve disease is reversible.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Particle concentration is known as a main factor that affects erosion rate of pipe bends in pneumatic conveyors. With consideration of different bend radii, the effect of particle concentration on weight loss of mild steel bends has been investigated in an industrial scale test rig. Experimental results show that there was a significant reduction of the specific erosion rate for high particle concentrations. This reduction was considered to be as a result of the shielding effect during the particle impacts. An empirical model is given. Also a theoretical study of scaling on the shielding effect, and comparisons with some existing models, are presented. It is found that the reduction in specific erosion rate (relative to particle concentration) has a stronger relationship in conveying pipelines than has been found in the erosion tester.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes hybrid mathematical model which couples the mechanics of the mass/spring model to the acoustic wave propagation model for use in generating the acoustic signal emitted by complex structures of paper fibres under strain. A discussion of the coupling method is presented including remarks on the errors encountered intrinsic to the discretisation scheme. The numerical results of a vibrating rubber band and a vibrating paper fibre are compared to their experimental counterparts. The fundamental frequencies of the acoustic signals are compared showing a close agreement between the experimental and numerical results

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Twentieth Century Society’s Spring lecture series (six in total) looks at the restoration and refurbishment of key C20 buildings in Britain and the US. Buildings covered: BBC Broadcasting House in London (G Val Meyer 1930-32, MacCormac Jamieson Prichard 2000-09). Speaker: Mark Hines (Mark Hines Architects), was the project architect and is the author of The Story of Broadcasting House: Home of the BBC. 5 February 2009. Crown Hall, Chicago (Mies van der Rohe 1952), the Art and Architecture Building, Yale University, New Haven (Paul Rudolf 1961-63) and the former Wills head office in Bristol (SOM with YRM 1970-75). Speaker: Patrick Bellew (Atelier 10 Engineers), 12 February 2009. Center for British Art, Yale University, New Haven (Louis Kahn 1969-77). Speaker: Peter Inskip (Inskip and Jenkins Architects), 17 February 2009. Brunswick Centre London (Patrick Hodgkinson 1967-72; Levitt Bernstein with Patrick Hodgkinson 2006). Speaker: Stuart Tappin (Stand Consulting Engineers Ltd), 26 February 2009. De La Warr Pavilion, Bexhill-on-Sea (Mendelsohn and Chermayeff 1934-5, John McAslan and Partners 2000-05). Speaker: Mark Cannata (HOK Architects), 5 March 2009. Finsbury Health Centre London (Lubetkin & Tecton 1938, first phase of conservation work Avanti Architects 1995.). Speaker: John Allan of Avanti Architects, 12 March 2009.

Relevância:

20.00% 20.00%

Publicador: