986 resultados para Scanner intraoral
Resumo:
通过分析波矢沿任意方向的单轴晶体的折射率,在光轴位于入射面内时,给出了入射光分别为s光和p光的反射率拟合函数。利用改进的反射率扫描仪,测量了CaCO3晶体的s光和p光反射率随入射角变化情况,由理论拟合获得单轴晶体的两个主折射率,分别为no=1.6559和ne=1.4851。这种方法不需要对样品进行加工,其精度达到0.0001。另外,对于晶体光轴未知的情况,采用改进的布儒斯特技术分别测出三个晶体表面的布儒斯特角,由此可以确定光轴的方向。
Resumo:
O uso de modelos de estudo dentários faz parte tanto da prática quanto da pesquisa odontológica e ortodôntica. Com a introdução dos scanners 3D e dos tomógrafos CBCT (cone beam computer tomography) tornou-se possível a obtenção de modelos dentários tridimensionais virtuais das arcadas dentárias. Foram selecionados 56 modelos dentários superiores e escaneados em três tipos diferentes de scanners: Maestro 3D Dental Scanner (AGE Solutions, Potedera, Italia), 3Shape R700 3D Scanner (3Shape, Copenhagen, Dinamarca) e o scanner 3Shape TRIOS (3Shape, Copenhagen, Dinamarca). Doze medidas foram realizadas nos modelos dentários de gesso e comparadas com as mesmas medidas realizadas nos modelos dentários digitais por meio do teste de Análise de Variância (ANOVA). Estatisticamente não foram encontradas diferenças significativas entre as medições tradicionais nos modelos dentários de gesso e as medidas realizadas nos modelos dentários digitais. Os três tipos de métodos de aquisição de modelos dentários digitais foram considerados confiáveis para as medições horizontais, transversais e verticais. Os modelos dentários virtuais podem ser indicados como substitutos dos modelos dentários de gesso.
Resumo:
A partir das dimensões dos indivíduos pode-se definir dimensionamentos adequados para os produtos e postos de trabalho, proporcionando segurança e conforto aos usuários. Com o avanço da tecnologia de digitalização de imagens (escaneamento) 3D, é possível tirar algumas medidas de maneira mais rápida e com a redução da presença do entrevistado durante o processo. No entanto, faltam estudos que avaliem estas tecnologias no Brasil, sendo necessária a realização de uma comparação das tecnologias e das respectivas precisões para que seu uso em pesquisas. Com o objetivo de oferecer métodos comparativos para escolha dos marcadores e equipamentos a serem utilizados em uma pesquisa antropométrica tridimensional da população brasileira, no presente estudo estão comparadas duas tecnologias de escaneamento: o sistema a laser WBX da empresa norte americana Cyberware e o sistema MHT da empresa russa Artec Group. O método para avaliação da precisão dimensional dos dados advindos desses equipamentos de digitalização de imagens 3D teve cinco etapas: Estudo dos processos de escaneamento; Escaneamento dos marcadores de pontos anatômicos; Escaneamento utilizando um corpo de prova cilíndrico; Escaneamento de um manequim; Escaneamento de um voluntário que teve seus pontos anatômicos marcados para a retirada de medidas. Foi feita uma comparação entre as medidas retiradas manualmente, por meio de antropômetro e virtualmente, com o auxílio do software de modelagem tridimensional Rhinoceros. Em relação aos resultados obtidos na avaliação do manequim e do voluntário, concluiu-se que a magnitude do erro absoluto é semelhante para ambos os scanners, e permanece constante independentemente das dimensões sob análise. As principais diferenças são em relação às funcionalidades dos equipamentos.
Resumo:
O presente trabalho teve como objetivo avaliar volumetricamente a presença de poros em três cimentos obturadores. Para a análise de porosidade, quatro cilindros de cada cimento foram preparados e escaneados usando um microtomógrafo de alta resolução (Skyscam 1174, Kontich, Bélgica). O cálculo da porosidade foi realizado por meio de análise de imagens digitalizadas dos blocos de cimentos. Os quais foram microtomografados para criação de modelos tridimensionais. A presença de poros e vacúolos foi então avaliada por inferência do software CT analiser. Os resultados mostraram que o i-Root SP teve o menor índice de porosidade (0,07%), enquanto o AH plus e o MTA Fillapex não apresentaram diferenças estatisticamente significativas entre si (p≥0,05). Apesar dos resultados para o índice de porosidade total do MTA Fillapex e do AH plus não terem diferenças significativas(p>0,05), os achados do presente trabalho mostraram que o MTA fillapex obteve resultados significativamente maiores nos volumes médios individuais dos poros internos que o Ah plus e o i-Root SP. Os resultados foram tabulados e analisados estatisticamete através do teste Anova ao nível de significância de 5%.
Resumo:
Os elásticos ortodônticos intermaxilares sintéticos vem sendo cada vez mais utilizados, sendo principalmente indicados para pacientes que apresentam hiper-sensibilidade ao látex. Afim de avaliar e comparar o comportamento de elásticos de látex e sintéticos quanto a perda de força ao longo do tempo, este estudo foi realizado tanto in vitro quanto in vivo. Para o estudo in vitro foram avaliados 15 elásticos de cada material, para cada tempo: 0, 1, 3, 12 e 24 horas. No estudo in vivo, pacientes foram avaliados (N=15), utilizando elásticos de ambos os materiais (látex e sintético), nos mesmos tempos do estudo in vitro. Os elásticos foram transferidos para a máquina de ensaios mecânicos (EMIC DL-500 MF). Os valores da força gerada foram registrados após a distensão dos elásticos a uma distância de 25mm. Foi aplicado o teste t pareado para a amostra clínica e independente para a amostra laboratorial. Foi utilizada a análise de variância (ANOVA) para verificar a variação das forças geradas entre os tempos determinados e o teste post-hoc para identificar entre quais tempos houve diferença significativa. Quanto às forças iniciais geradas (zero hora), os valores para os elásticos sintéticos foram bastante semelhantes entre os estudos laboratorial e clínico e ligeiramente superiores aos dos elásticos de látex. Nos tempos subsequentes, as forças geradas pelos elásticos de látex apresentaram valores superiores. Em relação à degradação do material, ao final de 24 horas, maior percentual foi observado para os elásticos sintéticos, tanto in vitro quanto in vivo. A maior queda nos valores das forças liberadas pelos elásticos de ambos os materiais e nos estudos clínico e laboratorial, ocorreu entre os tempos de 0 e 1 hora, seguida de uma queda gradativa e progressiva até o tempo de 24 horas. Os elásticos de látex apresentaram um comportamento mais estável no período estudado em relação aos sintéticos, em ambos os estudos.
Resumo:
A reação álcali-agregado - RAA é uma patologia de ação lenta que tem sido observada em construções de concreto capaz de comprometer suas estruturas. Sabe-se que a reação álcali-agregado é um fenômeno bastante complexo em virtude da grande variedade de rochas na natureza que são empregadas como agregados no preparo do concreto, podendo cada mineral utilizado afetar de forma distinta a reação ocorrida. Em função dos tipos de estrutura, das suas condições de exposição e dos materiais empregados, a RAA não se comporta sempre da mesma forma, em virtude disto a pesquisa constante neste tema é necessária para o meio técnico e a sociedade. Pesquisas laboratoriais, empíricas e experimentais tem sido rotina em muitos dos estudos da RAA dada ainda à carência de certas definições mais precisas a respeito dos métodos de ensaio, mas também em função da necessidade do melhor conhecimento dos materiais de uso em concretos como os agregados, cimentos, adições, aditivos entre outros e do comportamento da estrutura. Embora técnicas de prevenção possam reduzir significativamente a incidência da RAA, muitas estruturas foram construídas antes que tais medidas fossem conhecidas, havendo no Brasil vários casos de estruturas afetadas, sendo custosos os reparos dessas estruturas. Em estudos recentes sobre o tamanho das partículas de álcali-agregado e sua distribuição foi concluído que o tamanho do agregado está relacionado com o potencial danoso da RAA. Existem ainda indícios de que o tamanho e a distribuição dos poros do concreto também sejam capazes de influenciar o potencial reativo do concreto. Neste trabalho desenvolvemos um Sistema de Visão Artificial (SVA) que, com o uso de técnicas de Processamento de Imagens, é capaz de identificar em imagens de concreto, agregado e poros que atendam em sua forma, às especificações do usuário, possibilitando o cálculo da porosidade e produzindo imagens segmentadas à partir das quais será possível extrair dados relativos à geometria desses elementos. Serão feitas duas abordagens para a obtenção das imagens, uma por Escâner Comercial, que possui vantagens relacionadas à facilidade de aquisição do equipamento, e outra por micro tomógrafo. Uma vez obtidas informações sobre as amostras de concreto, estas podem ser utilizadas para pesquisar a RAA, comparar estruturas de risco com estruturas antigas de forma a melhorar a previsão de risco de ocorrência, bem como serem aplicadas a outras no estudo de outras patologias do concreto menos comuns no nosso país, como o efeito gelo/degelo.
Resumo:
Real-time acquisition of EMG during functional MRI (fMRI) provides a novel method of controlling motor experiments in the scanner using feedback of EMG. Because of the redundancy in the human muscle system, this is not possible from recordings of joint torque and kinematics alone, because these provide no information about individual muscle activation. This is particularly critical during brain imaging because brain activations are not only related to joint torques and kinematics but are also related to individual muscle activation. However, EMG collected during imaging is corrupted by large artifacts induced by the varying magnetic fields and radio frequency (RF) pulses in the scanner. Methods proposed in literature for artifact removal are complex, computationally expensive, and difficult to implement for real-time noise removal. We describe an acquisition system and algorithm that enables real-time acquisition for the first time. The algorithm removes particular frequencies from the EMG spectrum in which the noise is concentrated. Although this decreases the power content of the EMG, this method provides excellent estimates of EMG with good resolution. Comparisons show that the cleaned EMG obtained with the algorithm is, like actual EMG, very well correlated with joint torque and can thus be used for real-time visual feedback during functional studies.
Resumo:
The pharaoh Cuttlefish (Sepia Pharaonis) is the most abundant species in the persian gulf and oman sea. The stock patterns of this species was studied conserning biological, morphological and electrophoretical aspects. In addition to measuring the biological patterns; 21 quantitative and qualitative factors were measured or counted. There tissues namely muscle, eye and liver were also used for further polyacrylamide electrophoresis analysis (SDS-Page method). The densitograms of protein bands of each tissue were prepared by Gel-Scanner and also the amount of bands' areas were estimated. The results of LSD test showed that tentacle length (TL), Tentacle club length (TCL) and TCL were indicative factors which they showed significant difference between male TL and female specimen of Bushehr and Balouchestan regions. Regarding to length and weight frequencies data the results indicated that males are always bigger than females and also, the cuttlefishes of the gulf of oman are bigger than persian gulf's samples. There were found a significant sample correlation (95%) between different quantitative parameters and the most correlation (0.963) was found to be between TL and TCL; whereas the less correlation (0.384) was observed between GL and LA3. However the gill length factor illustrated the less correlation with the other factors. The results of Cluster analysis for both sexes showed that the cuttlefishes of both studied regions belongs to seperate stocks. The electrophoretic experiments of proteins showed that the protein bands of the sample tissue of muscle and eye from both sampling areas revealed significant differences; whereas the tissue of liver wasn't recognized as an indicative tissue for population studies. Taking into consideration the findings of the present study including: (1) difference in spawning season, (2) results of dendrograms, (3) observed Significant differences in one-way analysis of variance (ANOVA) for morphometric measurements, (4) differences in body length and weight, (5) ecological variations of the persian gulf and oman sea, (6) as well as the results of electrophoresis of proteins have indicatend that: "The Pharaoh cuttlefishes of Bushehr and Balouchestan waters belong to two seperate stocks. Also, it is believed that each region has propably two different populations and more studies are needed to approve this result.
Resumo:
There is growing evidence that focal thinning of cortical bone in the proximal femur may predispose a hip to fracture. Detecting such defects in clinical CT is challenging, since cortices may be significantly thinner than the imaging system's point spread function. We recently proposed a model-fitting technique to measure sub-millimetre cortices, an ill-posed problem which was regularized by assuming a specific, fixed value for the cortical density. In this paper, we develop the work further by proposing and evaluating a more rigorous method for estimating the constant cortical density, and extend the paradigm to encompass the mapping of cortical mass (mineral mg/cm(2)) in addition to thickness. Density, thickness and mass estimates are evaluated on sixteen cadaveric femurs, with high resolution measurements from a micro-CT scanner providing the gold standard. The results demonstrate robust, accurate measurement of peak cortical density and cortical mass. Cortical thickness errors are confined to regions of thin cortex and are bounded by the extent to which the local density deviates from the peak, averaging 20% for 0.5mm cortex.
Resumo:
There is growing evidence that focal thinning of cortical bone in the proximal femur may predispose a hip to fracture. Detecting such defects in clinical CT is challenging, since cortices may be significantly thinner than the imaging system's point spread function. We recently proposed a model-fitting technique to measure sub-millimetre cortices, an ill-posed problem which was regularized by assuming a specific, fixed value for the cortical density. In this paper, we develop the work further by proposing and evaluating a more rigorous method for estimating the constant cortical density, and extend the paradigm to encompass the mapping of cortical mass (mineral mg/cm 2) in addition to thickness. Density, thickness and mass estimates are evaluated on sixteen cadaveric femurs, with high resolution measurements from a micro-CT scanner providing the gold standard. The results demonstrate robust, accurate measurement of peak cortical density and cortical mass. Cortical thickness errors are confined to regions of thin cortex and are bounded by the extent to which the local density deviates from the peak, averaging 20% for 0.5mm cortex. © 2012 Elsevier B.V.
Resumo:
采用连续模拟降雨试验,对坡沟系统概化模型进行坡面沟蚀发育过程模拟,再现坡面片蚀—细沟侵蚀—切沟侵蚀演变过程。结合3种测量技术从测量精度、测量人员要求、数据处理、数据通用性、配套软件使用、前期投入、测量条件等几个方面入手,对比分析高精度GPS(Trimble 5700)、三维激光扫描仪(Leica HDS 3000)和测针板的3种测量方法的优缺点,同时对3种测量方法在沟蚀过程监测和侵蚀量估算方面进行对比研究。结果表明,激光扫描仪能很好地监测沟蚀演变过程,且对侵蚀量估算精度较高,误差仅为4.5%。高精度GPS也能很好地监测沟蚀演变过程,对侵蚀量估算精度误差为7.38%。测针板法不能很好的反映沟蚀演变过程,但是对于侵蚀量的估算可以满足日常要求,误差为-12.78%。
Resumo:
Within the framework of the pilot heavy-ion therapy facility at GSI equipped with an active beam delivery system of advanced raster scanning technique, a feasibility study on actively conformal heavy-ion irradiation to moving tumors has been experimentally conducted. Laterally, real-time corrections to the beam scanning parameters by the raster scanner, leading to an active beam tracing, compensate for the lateral motion of a target volume. Longitudinally, a mechanically driven wedge energy degrader (called depth scanner) is applied to adjust the beam energy so as to locate the high-dose Bragg peak of heavy ion beam to the slice under treatment for the moving target volume. It has been experimentally shown that compensations for lateral target motion by the raster scanner and longitudinal target shift by the depth scanner are feasible.
Resumo:
A prototype of time-of-flight positron emission computed tomography (TOF-PET) has been developed for acquiring the coincident detection of 511 keV gamma-rays produced from positron annihilation. It consists of two 80.5 mmx80.5 mm LYSO scintillator arrays (composed of 35 x35 pixel finger crystals) with the position sensitive photomultiplier tubes R2487 as the readout. Each array is composed of 2 mm x2 mm x 15 mm finger crystals and the average pixel pitch is 2.30 mm. The measured results indicate that the TOF information has the potential to significantly enhance the image quality by improving the noise variance in the image reconstruction. The best spatial resolution (FWHM) of the prototype for the pairs of 511 keV gamma-rays is 1.98 mm and 2.16 mm in the x and y directions, respectively, which are smaller than the average pixel pitch of 2.30 mm.
Resumo:
成功研制一套适合于ECR离子源引出束流发射度测量的探测器ESS(Electric-SweeP Scanner)。该探测器主要由测量探头、机械驱动装置、计算机控制及数据获取系统组成。ESS探测器所采用的测量方法是双狭缝加电扫描法,具有速度快、精度高,能够比较直观的反映束流的发射度相图、相空间密度分布等特点,是目前ECR离子源引出束流发射度测量的有效手段。本论文对发射度探测器ESS的原理、结构及物理和技术设计作了较详细的描述,并给出了相应的设计图纸及数值模拟结果。最后,利用Ess探测器对LECR3(Lanzhou No.3)离子源引出的04+离子束的发射度作了初步测量。当04+引出束流为343μA日寸,初步测量所得水平方向的发射度为227mm·mrad(约90%束流),并给出了相应的束流发射度相图和束流相空间密度分布。
Resumo:
利用光线的反射与聚焦成象原理 ,将地表高程转换成不同物象点位置的电信号 ,再经计算机处理成数字高程模型 ,即形成用于获取地表糙度数字高程模型的激光微地貌扫描仪。实验测量得到 :在相同初始条件下 ,不同坡度土槽放水和降雨实验后地表形态的数字地形模型。通过对侵蚀地表形态的分析 ,得出坡度对坡面侵蚀及沟蚀影响的某些初步规律。