906 resultados para SURFACE BRIGHTNESS TECHNIQUE
Resumo:
Browse > Journals> Automation Science and Enginee ...> Volume: 5 Issue: 3 Microassembly Fabrication of Tissue Engineering Scaffolds With Customized Design 4468741 abstract Han Zhang; Burdet, E.; Poo, A.N.; Hutmacher, D.W.; GE Global Res. Center Ltd., Shanghai This paper appears in: Automation Science and Engineering, IEEE Transactions on Issue Date: July 2008 Volume: 5 Issue:3 On page(s): 446 - 456 ISSN: 1545-5955 Digital Object Identifier: 10.1109/TASE.2008.917011 Date of Current Version: 02 July 2008 Sponsored by: IEEE Robotics and Automation Society Abstract This paper presents a novel technique to fabricate scaffold/cell constructs for tissue engineering by robotic assembly of microscopic building blocks (of volume 0.5$,times,$0.5$,times,$0.2 ${hbox{mm}}^{3}$ and 60 $mu {hbox{m}}$ thickness). In this way, it becomes possible to build scaffolds with freedom in the design of architecture, surface morphology, and chemistry. Biocompatible microparts with complex 3-D shapes were first designed and mass produced using MEMS techniques. Semi-automatic assembly was then realized using a robotic workstation with four degrees of freedom integrating a dedicated microgripper and two optical microscopes. Coarse movement of the gripper is determined by pattern matching in the microscopes images, while the operator controls fine positioning and accurate insertion of the microparts. Successful microassembly was demonstrated using SU-8 and acrylic resin microparts. Taking advantage of parts distortion and adhesion forces, which dominate at micro-level, the parts cleave together after assembly. In contrast to many current scaffold fabrication techniques, no heat, pressure, electrical effect, or toxic chemical reaction is involved, a critical condition for creating scaffolds with biological agents.
Resumo:
Purpose To investigate static upper eyelid pressure and contact with the ocular surface in a group of young adult subjects. Methods Static upper eyelid pressure was measured for 11 subjects using a piezoresistive pressure sensor attached to a rigid contact lens. Measures of eyelid pressure were derived from an active pressure cell (1.14 mm square) beneath the central upper eyelid margin. To investigate the contact region between the upper eyelid and ocular surface, we used pressure sensitive paper and the lissamine-green staining of Marx’s line. These measures combined with the pressure sensor readings were used to derive estimates of eyelid pressure. Results The mean contact width between the eyelids and ocular surface estimated using pressure sensitive paper was 0.60 ± 0.16 mm, while the mean width of Marx’s line was 0.09 ± 0.02 mm. The mean central upper eyelid pressure was calculated to be 3.8 ± 0.7 mmHg (assuming that the whole pressure cell was loaded), 8.0 ± 3.4 mmHg (derived using the pressure sensitive paper imprint widths) and 55 ± 26 mmHg (based on contact widths equivalent to Marx’s line). Conclusions The pressure sensitive paper measurements suggest that a band of the eyelid margin, significantly larger than the anatomical zone of the eyelid margin known as Marx’s line, has primary contact with the ocular surface. Using these measurements as the contact between the eyelid margin and ocular surface, we believe that the mean pressure of 8.0 ± 3.4 mmHg is the most reliable estimate of static upper eyelid pressure.
Resumo:
Although comparison phakometry has been used by a number of studies to measure posterior corneal shape, these studies have not calculated the size of the posterior corneal zones of reflection they assessed. This paper develops paraxial equations for calculating posterior corneal zones of reflection, based on standard keratometry equations and equivalent mirror theory. For targets used in previous studies, posterior corneal reflection zone sizes were calculated using paraxial equations and using exact ray tracing, assuming spherical and aspheric corneal surfaces. Paraxial methods and exact ray tracing methods give similar estimates for reflection zone sizes less than 2 mm, but for larger zone sizes ray tracing methods should be used.
Resumo:
Multilevel inverters provide an attractive solution for power electronics when both reduced harmonic contents and high voltages are required. In this paper, a novel predictive current control technique is proposed for a three-phase multilevel inverter, which controls the capacitors voltages and load currents with low switching losses. The advantage of this contribution is that the technique can be applied to more voltage levels without significantly changing the control circuit. The three-phase three-level inverter with a pure inductive load has been implemented to track reference currents using analogue circuits and programmable logic device.
Resumo:
The aggregate structure which occurs in aqueous smectitic suspensions is responsible for poor water clarification, difficulties in sludge dewatering and the unusual rheological behaviour of smectite rich soils. These macroscopic properties are dictated by the 3-D structural arrangement of smectite finest fraction within flocculated aggregates. Here, we report results from a relatively new technique, Transmission X-ray Microscopy (TXM), which makes it possible to investigate the internal structure and 3-D tomographic reconstruction of the smectite clay aggregates modified by Al13 keggin macro-molecule [Al13(O)4(OH)24(H2O)12 ]7+. Three different treatment methods were shown resulted in three different micro-structural environments of the resulting flocculation.
Resumo:
Background: Mechanical forces either due to accommodation or myopia may stretch the retina and/or cause shear between the retina and choroid. This can be investigated by making use of the Stiles-Crawford effect (SCE), which is the phenomenon of light changing in apparent brightness as it enters through different positions in the pupil. The SCE can be measured by psychophysical and objective techniques, with the SCE parameters being directionality (rate of change across the pupil), and orientation (the location of peak sensitivity in the pupil). Aims: 1. To study the changes in foveal SCE with accommodation in emmetropes and myopes using a subjective (psychophysical) technique. 2. To develop and evaluate a quick objective technique of measuring the SCE using the multifocal electroretinogram. Methods: The SCE was measured in 6 young emmetropes and 6 young myopes for up to 8 D accommodation stimulus with a psychophysical technique and its variants. An objective technique using the multifocal electroretinogram was developed and evaluated with 5 emmetropes. Results: Using the psychophysical technique, the SCE directionality increased by similar amounts in both emmetropes and myopes as accommodation increased, with an increase of 15-20% with 6 D of accommodation. However, there were no significant orientation changes. Additional measurements showed that most of the change in the directionality was probably an artefact of optical factors such as higher-order aberrations and accommodative lag rather a true effect of accommodation. The multifocal technique demonstrated the presence of the SCE, but results were noisy and too variable to detect any changes in SCE directionality or orientation with accommodation. Conclusion: There is little true change in the SCE with accommodation responses up to 6 D in either emmetropes or myopes, although it is possible that substantial changes might occur at very high accommodation levels. The objective technique using the multifocal electroretinogram was quicker and less demanding for the subjects than the psychophysical technique, but as implemented in this thesis, it is not a reliable method of measuring the SCE.
Resumo:
‘Practice makes perfect’ expresses the common misconception that repetitive practice without appropriate feed-back will deliver improvement in tasks being practised. This paper explores the implementation of a student-driven feed-back mechanism and shows how functional and aesthetic understanding can be progressively enhanced through reflective practice. More efficient practice of clearly understood tasks will enhance dance training outcomes. We were looking for ways to improve teaching efficiency, effectiveness of the students’ practice in the studio and application of safe dance practices. We devised a web-based on-line format, ‘Performing Reflective Practice’, designed to augment and refine studio practice. Only perfect practice makes perfect!
Resumo:
Sub-surface minerals are in most cases considered to be the proprietary right of a country should those minerals be found within its borders. PRO169 (Indigenous Peoples’ Rights, International Labour Organization) has recorded instances where the private land of indigenous peoples has been pilfered by a government – often through the sale of a contract to a private company, and without the consent of the people living on that land. Other times, indigenous peoples, the government they find themselves living in, and the company that bought mining rights engage in consultation. But these practices are far from transparent, equitable, or fair as indigenous peoples are often unskilled in contractual law and do not have the same legal resources as the company or government does. This paper argues that the sub-surface minerals found within the territory of indigenous tribes should be legally allocated as theirs.