861 resultados para REFRACTIVE-INDEXES


Relevância:

10.00% 10.00%

Publicador:

Resumo:

对光折变全息记录特别是双中心全息记录中90°记录结构下较低的衍射效率进行了研究, 采用局域衍射理论对90°记录结构的衍射进行了分析,表明在同样的折射率变化和2 mm的光束宽度的情况下, 只有当折射率光栅振幅大于10-4时, 90°记录结构衍射效率才能够与小角度透射记录结构的衍射效率大致相当。针对环境干扰导致的干涉条纹振动影响光栅记录, 提出了有效调制度概念, 根据分析90°记录结构的干涉条纹间距很小, 容易受外界环境干扰而导致低的折射率变化率, 因此应采用主动条纹锁定系统。此外在双中心全息记录中, 微观光

Relevância:

10.00% 10.00%

Publicador:

Resumo:

主要介绍了椭偏仪的测量原理,比较了不同结构的椭偏仪,并根据具体应用需求介绍了椭偏光谱仪、红外椭偏光谱仪、成像椭偏仪和广义椭偏仪,分析了椭偏仪的数据处理过程,最后展望了椭偏仪的发展趋势。

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A scheme is proposed to transform an optical pulse into a millimeter-wave frequency modulation pulse by using a weak fiber Bragg grating (FBG) in a fiber-optics system. The Fourier transformation method is used to obtain the required spectrum response function of the FBG for the Gaussian pulse, soliton pulse, and Lorenz shape pulse. On the condition of the first-order Born approximation of the weak fiber grating, the relation of the refractive index distribution and the spectrum response function of the FBG satisfies the Fourier transformation, and the corresponding refractive index distribution forms are obtained for single-frequency modulation and linear-frequency modulation millimeter-wave pulse generation. The performances of the designed fiber gratings are also studied by a numerical simulation method for a supershort pulse transmission. (c) 2007 Optical Society of America.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

采用反射式达曼光栅对飞秒激光进行分束,可以避免材料色散的影响。搭建了利用反射式1×2达曼光栅为基础的频率分辨光学开关(FROG)装置,并把测量结果与传统多发频率分辨光学开关装置的测量结果进行了对比。理论和实验结果表明,当输入脉冲宽度大于50 fs时,用达曼光栅作为分光器和使用分光镜分光的效果是一样的;当输入脉冲的宽度小于50 fs时,用达曼光栅作为分光器引入的展宽量明显小于分光镜引入的展宽量,尤其是当输入脉冲的宽度小于20 fs时用达曼光栅作为分光器的效果更为突出。

Relevância:

10.00% 10.00%

Publicador:

Resumo:

As hepatites crônicas por vírus são as mais frequentes, destacando-se os vírus das hepatites B (VHB) e C (VHC). O estudo anatomopatológico da biópsia hepática é considerado o padrão ouro para avaliar com precisão a distorção arquitetural e o grau de fibrose do parênquima do fígado, importantes fatores prognósticos para os pacientes portadores de hepatites crônicas virais. Na avaliação histopatológica atual, em adição aos relatos subjetivos das alterações histológicas, escores semiquantitativos que correlacionam achados morfológicos com graus numéricos são usados, tais como os reconhecidos escores de Ishak e METAVIR. Entretanto, em todos estes sistemas há a desvantagem da subjetividade do examinador e da incorporação de alterações categóricas, sem referências às mudanças quantitativas do colágeno hepático. Técnicas de análise de imagens digitais (AID) que fornecem quantificação objetiva dos graus de fibrose em amostras histológicas têm sido desenvolvidas. Todavia, o alto custo e dificuldade ao acesso das tecnologias descritas restringem seu uso a poucos centros especializados. Este estudo visa o desenvolvimento de uma técnica de custo acessível para a análise de imagens digitais da fibrose hepática em hepatites crônicas virais. Foram estudadas 304 biópsias de pacientes com hepatite crônica por vírus B e C, obtidas através de agulhas Menghini. Todas as amostras tinham pelo menos 15 mm de comprimento ou cinco espaços-porta completos e foram coradas pelo método Tricrômico de Masson. O estadiamento foi feito por um único hepatopatologista experiente, sem o conhecimento dos dados clínicos dos pacientes. Os escores de Ishak e METAVIR foram aplicados. As imagens microscópicas foram digitalizadas. Os índices de fibrose foram determinados de forma automatizada, em técnica desenvolvida no programa Adobe Photoshop. Para o escore de Ishak, observamos os seguintes índices de Fibrose (IF) médios: 0,8% 0,0 (estágio 0), 2.4% 0,6 (estágio 1), 4,7% 1,6 (estágio 2), 7,4% 1,4 (estágio 3), 14,9% 3,7 (estágio 4), 23,4% 2,9 (estágio 5) e 34,5% 1,5 (estágio 6). Para a classificação METAVIR: 0,8% 0,1 (estágio F0), 3,8% 1,8 (estágio F1), 7,4% 1,4 (estágio F2), 20,4% 5,2 (estágio F3) e 34,5% 1,5 (estágio F4). Observamos uma excelente correlação entre os índices de fibrose da AID e os escores de Ishak (r=0,94; p<0,001) e METAVIR (r=0,92; p<0,001). Em relação à indicação de tratamento antiviral, foi observado IF médio de 16,4%. Em relação ao diagnóstico de cirrose, foi observado IF médio de 26,9%, para o escore de Ishak, e 34,5% para a classificação METAVIR. A reprodutibilidade intra-observador foi excelente. Este novo método de análise de imagens digitais para a quantificação de fibrose hepática tem custo acessível e foi desenvolvido com tecnologia que está disponível em todo o mundo, permitindo identificar com precisão todos os estágios de fibrose, com excelente reprodutibilidade intra-observador.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A novel multifunctional inorganic-organic photorefractive (PR) poly(N-vinyl)-3-[p-nitrophenylazolcarbazolyl-CdS nanocomposites with different molar ratios of US to poly(N-vinyl)-3-[p-nitrophenylazo]carbazolyl (PVNPAK) were synthesized via a postazo-coupling reaction and chemically hybridized approach, respectively. The nanocomposites are highly soluble and could be obtained as film-forming materials with appreciably high molecular weights and low glass transition temperature (T,) due to the flexible spacers. The PVNPAK matrix possesses a highest-occupied molecular orbital value of about -5.36 eV determined from cyclic voltammetry. Second harmonic generation (SHG) could be observed in PVNPAK film without any poling procedure and 4.7 pm/V of effective second-order nonlinear optical susceptibility is obtained. The US particles as photosensitizers had a nanoscale size in PVNPAK adopting transmission electron microscopy. The improvement of interface quality between US and polymer matrix is responsible for efficient photoinduced charge generation efficiency in the nanocomposites. An asymmetric optical energy exchange between two beams on the polymer composites PVNPAK-CdS/ECZ has been found even without an external field in two-beam coupling (TBC) experiment, and the TBC gain and diffraction efficiency of 14.26 cm(-1) and 3.4% for PVNPAK-5-CdS/ECZ, 16.43 cm(-1) and 4.4% for PVNPAK-15-CdS/ECZ were measured at a 647.1 nm wavelength, respectively.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In a paper published in 1961, L. Cesari [1] introduces a method which extends certain earlier existence theorems of Cesari and Hale ([2] to [6]) for perturbation problems to strictly nonlinear problems. Various authors ([1], [7] to [15]) have now applied this method to nonlinear ordinary and partial differential equations. The basic idea of the method is to use the contraction principle to reduce an infinite-dimensional fixed point problem to a finite-dimensional problem which may be attacked using the methods of fixed point indexes.

The following is my formulation of the Cesari fixed point method:

Let B be a Banach space and let S be a finite-dimensional linear subspace of B. Let P be a projection of B onto S and suppose Г≤B such that pГ is compact and such that for every x in PГ, P-1x∩Г is closed. Let W be a continuous mapping from Г into B. The Cesari method gives sufficient conditions for the existence of a fixed point of W in Г.

Let I denote the identity mapping in B. Clearly y = Wy for some y in Г if and only if both of the following conditions hold:

(i) Py = PWy.

(ii) y = (P + (I - P)W)y.

Definition. The Cesari fixed paint method applies to (Г, W, P) if and only if the following three conditions are satisfied:

(1) For each x in PГ, P + (I - P)W is a contraction from P-1x∩Г into itself. Let y(x) be that element (uniqueness follows from the contraction principle) of P-1x∩Г which satisfies the equation y(x) = Py(x) + (I-P)Wy(x).

(2) The function y just defined is continuous from PГ into B.

(3) There are no fixed points of PWy on the boundary of PГ, so that the (finite- dimensional) fixed point index i(PWy, int PГ) is defined.

Definition. If the Cesari fixed point method applies to (Г, W, P) then define i(Г, W, P) to be the index i(PWy, int PГ).

The three theorems of this thesis can now be easily stated.

Theorem 1 (Cesari). If i(Г, W, P) is defined and i(Г, W, P) ≠0, then there is a fixed point of W in Г.

Theorem 2. Let the Cesari fixed point method apply to both (Г, W, P1) and (Г, W, P2). Assume that P2P1=P1P2=P1 and assume that either of the following two conditions holds:

(1) For every b in B and every z in the range of P2, we have that ‖b=P2b‖ ≤ ‖b-z‖

(2)P2Г is convex.

Then i(Г, W, P1) = i(Г, W, P2).

Theorem 3. If Ω is a bounded open set and W is a compact operator defined on Ω so that the (infinite-dimensional) Leray-Schauder index iLS(W, Ω) is defined, and if the Cesari fixed point method applies to (Ω, W, P), then i(Ω, W, P) = iLS(W, Ω).

Theorems 2 and 3 are proved using mainly a homotopy theorem and a reduction theorem for the finite-dimensional and the Leray-Schauder indexes. These and other properties of indexes will be listed before the theorem in which they are used.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An experimental investigation of the optical properties of β–gallium oxide has been carried out, covering the wavelength range 220-2500 nm.

The refractive index and birefringence have been determined to about ± 1% accuracy over the range 270-2500 nm, by the use of a technique based on the occurrence of fringes in the transmission of a thin sample due to multiple internal reflections in the sample (ie., the "channelled spectrum" of the sample.)

The optical absorption coefficient has been determined over the range 220 - 300 nm, which range spans the fundamental absorption edge of β – Ga2O3. Two techniques were used in the absorption coefficient determination: measurement of transmission of a thin sample, and measurement of photocurrent from a Schottky barrier formed on the surface of a sample. Absorption coefficient was measured over a range from 10 to greater than 105, to an accuracy of better than ± 20%. The absorption edge was found to be strongly polarization-dependent.

Detailed analyses are presented of all three experimental techniques used. Experimentally determined values of the optical constants are presented in graphical form.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Static optical transmission is restudied by postulation of the optical path as the proper element in a three-dimensional Riemannian manifold (no torsion); this postulation can be applied to describe the light-medium interactive system. On the basis of the postulation, the behaviors of light transmitting through the medium with refractive index n are investigated, the investigation covering the realms of both geometrical optics and wave optics. The wave equation of light in static transmission is studied modally, the postulation being employed to derive the exact form of the optical field equation in a medium (in which the light is viewed as a single-component field). Correspondingly, the relationships concerning the conservation of optical fluid and the dynamic properties are given, and some simple applications of the theories mentioned are presented.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

By generalization of the methods presented in Part I of the study [J. Opt. Soc. Am. A 12, 600 (1994)] to the four-dimensional (4D) Riemannian manifold case, the time-dependent behavior of light transmitting in a medium is investigated theoretically by the geodesic equation and curvature in a 4D manifold. In addition, the field equation is restudied, and the 4D conserved current of the optical fluid and its conservation equation are derived and applied to deduce the time-dependent general refractive index. On this basis the forces acting on the fluid are dynamically analyzed and the self-consistency analysis is given.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

以硅酸四乙酯(TEOS)和甲基三乙氧基硅烷(MTEOS)为前驱材料,用溶胶-凝胶(sol-gel)方法在钛宝石表面制备得到均匀性良好且具有高激光损伤阈值的有机硅复合凝胶增透膜。膜层在钛宝石激光器输出波段(750~850nm)的增透效果显著,其平均透过率超过98.6%;激光破坏阈值为2.2J/cm^2(800nm,300ps);膜层表面均匀性达到激光波面的要求,在皮秒、飞秒超短脉冲高功率激光领域具有应用价值。溶胶的性能测试结果表明,溶胶粘度和成膜折射率均随溶液中CH3SiO1.5溶胶体含量的增加而增大,而膜

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Porous SiO2 antireflective (AR) coatings are prepared from the colloidal silica solution modified with methyltriethoxysilane (MTES) based on the sol-gel route. The viscosity of modified silica suspensions changes but their stability keeps when MTES is introduced. The refractive indices of modified coatings vary little after bake treatment from 100 to 150 Celsius. The modified silica coatings on Ti:sapphire crystal, owning good homogeneity, display prominent antireflective effect within the laser output waveband (750-850 nm) of Ti:sapphire lasers, with average transmission above 98.6%, and own laser induced damage thresholds (LIDTs) of more than 2.2 J/cm2 at 800 nm with the pulse duration of 300 ps.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this paper, a refractive index pro. le design enabling us to obtain a. at modal field around the fibre centre is investigated. The theoretical approach for designing such multilayer large flattened mode (LFM) optical fibres is presented. A comparison is made between the properties of a three-layer LFM structure and a standard step-index pro. le with the same core size. The obtained results indicate that the effective area of the LFM fibre is about twice as large as that of the standard step-index fibre, but the LFM fibre has less effective ability to filter out the higher order modes than the standard step-index fibre with the same bending radius.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Este trabalho tem por objetivo verificar se há diferença quanto ao nível de significância estatística no cálculo do retorno anormal realizado através de quatro modelos estatísticos utilizados em estudos de eventos, tendo como objeto de estudo empresas no mercado de ações no Brasil durante o período de março de 2003 até julho de 2010 na Bovespa. Considerando a importância do cálculo do retorno anormal nos estudos de eventos, bem como possíveis variações de resultados decorrentes da escolha do modelo de cálculo, este estudo utiliza um tema bastante conhecido, qual seja, o anúncio de recompra de ações feito pela própria companhia emissora dos títulos. A metodologia utilizada nesta pesquisa foi quantitativa, utilizando o estudo de corte transversal. Os resultados apontam que há diferença entre os níveis de significância encontrados. Ao analisar o gráfico dos modelos calculados no período da janela do evento, verificou-se que as empresas que recompraram ações a fizeram quando os papéis estavam com retorno anormal acumulado negativo e, após a recompra, os papéis tiveram retornos anormais acumulados positivos. Recalculou-se os dois modelos que utilizam o Ibovespa em sua fórmula de cálculo, através de um Ibovespa sem ponderação e conclui-se que os resultados apontam na direção de se evitar o uso de índices ponderados de mercado, preferindo a utilização de carteiras compostas apenas com uma ação para cada empresa componente da carteira de controle. Após este recálculo, verificou-se que o modelo que era menos próximo dos demais graficamente era o modelo de retorno ajustado ao mercado ponderado. Por fim, as evidências empíricas indicam que o mercado de capitais brasileiro ajusta tempestivamente os papéis das empresas que realizaram recompra de ações, em linha com o que prescreve a hipótese do mercado eficiente na sua forma semiforte.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

综合介绍了掺稀土离子液体激光器的主要发展历程,分析了掺稀土离子液体激光材料研究过程中需要解决的主要问题包括降低无辐射跃迁、增大溶解度和减少热致折射率梯度引起的光偏折损耗等。重点介绍了稀土离子在溶液中的无辐射跃迁机理以及降低无辐射跃迁的措施。